{"product_id":"yokogawa-nfdv151-p10-ccc01-digital-input-module","title":"Yokogawa NFDV151-P10\/CCC01 Digital Input Module","description":"\u003cp\u003eConfigured for high-density digital signal acquisition in STARDOM control networks, the \u003cstrong\u003eYokogawa NFDV151-P10\/CCC01\u003c\/strong\u003e (\u003cstrong\u003eNFDV151-P10\u003c\/strong\u003e Digital Input Module) provides direct electrical execution of 32-channel isolated logic status monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFDV151-P10\/CCC01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FCN\/STARDOM module housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 isolated (sink\/source compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC (input to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 8 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes galvanic isolation to provide 2 kV AC protection between input field signals and the internal system backplane. This architecture prevents common-mode noise and ground-loop currents from propagating into the FCN autonomous controller. Integrated surge protection is implemented on each of the 32 channels, providing voltage transient suppression for field instrumentation. The circuitry supports deterministic input detection with a max cycle of 25 Hz for pushbutton inputs, ensuring data consistency for time-sensitive logic execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module capable of handling both sink and source input configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the NFDV151-P10\/CCC01 is engineered to support both sink and source input types, offering flexibility for different field device wiring standards without requiring hardware modifications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the insulation rating between the channel common groups?\u003c\/p\u003e\n\u003cp\u003eA: The module provides an isolation voltage of 500 V AC between common segments, which are grouped every 16 channels to maintain segmentation integrity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control system is powered down before inserting the module into the FCN base unit slot.\u003c\/li\u003e\n\u003cli\u003eWhen utilizing pressure clamp terminal blocks, strip wires to exactly 11 mm to ensure proper contact and pull-out resistance.\u003c\/li\u003e\n\u003cli\u003eFor cabling, adhere to the 0.5–2 mm² (AWG 20–14) range; exceeding this diameter may compromise the terminal block structural integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring provides an OFF voltage level of \u0026lt;= 5.0 VDC to prevent false-high logic status reading.\u003c\/li\u003e\n\u003cli\u003eEnsure the cabinet environment remains within the 5% to 95% RH non-condensing humidity range to prevent internal moisture accumulation on the PCB surface.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49208301256956,"sku":"NFDV151-P10\/CCC01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NFDV151-P10.jpg?v=1781055595","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-nfdv151-p10-ccc01-digital-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}