{"product_id":"yokogawa-ycb147-4-br-plc-cable","title":"YOKOGAWA YCB147-4\/BR PLC Cable","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA YCB147-4\/BR\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eYCB147\u003c\/strong\u003e Signal Cable, operates as a dedicated hardware component for high-density analog and digital signal interconnection between industrial field terminal blocks and Yokogawa controller modules.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYCB147\u003c\/strong\u003e: Base model designation for the multi-core interface cable series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: Indicates the specific cable length configuration (4 m).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\/BR\u003c\/strong\u003e: Denotes the connector shielding and protective conduit jacket specification.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB147-4\/BR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003ejapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eHigh-density I\/O connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe YCB147 series cables are engineered to maintain signal integrity within Yokogawa process control environments, facilitating seamless communication between field I\/O and control station backplanes. The cable incorporates channel-to-channel shielding to prevent cross-talk and electromagnetic interference (EMI) ingress, ensuring that sensitive 4-20 mA HART loop protocol signals remain within specified accuracy tolerances. By utilizing high-conductivity copper cores and robust insulation, the YCB147 provides the electrical pathway necessary for deterministic data exchange across industrial automation platforms.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the YCB147-4\/BR be routed through cable trays alongside high-voltage power lines?\u003c\/p\u003e\n\u003cp\u003eA: No, signal cables must be segregated from high-voltage conduits to prevent induced noise and potential packet corruption. Maintain the manufacturer's recommended separation distance for instrumentation cabling.\u003c\/p\u003e\n\u003cp\u003eQ: Are the connectors on the YCB147-4\/BR field-repairable?\u003c\/p\u003e\n\u003cp\u003eA: The connector assemblies are factory-molded for environmental protection; field repair or re-termination of the pins is not recommended as it compromises the factory-tested seal and electrical impedance specifications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Alignment\u003c\/strong\u003e: Ensure the connector pins are perfectly aligned with the mating interface on the I\/O module before engaging the locking mechanism to prevent pin deformation or housing damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius\u003c\/strong\u003e: Adhere to a minimum bend radius of 10 times the cable diameter to prevent mechanical stress on internal twisted pairs and signal degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: The \"\/BR\" shielding must be properly bonded to the control cabinet's instrument earth bus at the designated terminal point to effectively mitigate common-mode electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment\u003c\/strong\u003e: Ensure the cable jacket is protected from direct chemical exposure or excessive heat sources that could cause insulation embrittlement or failure over time.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49218329903356,"sku":"YCB147-4\/BR","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ESB_YCB301-C1001.jpg?v=1781229270","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-ycb147-4-br-plc-cable","provider":"Electronic PLC","version":"1.0","type":"link"}