{"title":"Bently Nevada 3300 Series","description":"\u003cp\u003e\u003cspan\u003eThis collection includes Bently Nevada 3300 series machinery monitoring components widely used for vibration measurement and rotating equipment protection.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"bently-nevada-3300-series-3300-10-02-02-00-ac-power-supply-module","title":"Bently Nevada 3300 Series 3300\/10-02-02-00 AC Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efoundational power conversion module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 Machinery Protection System\u003c\/strong\u003e. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability power supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to occupy the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efar-left position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 rack\u003c\/strong\u003e, converting primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efacility AC power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto the regulated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC voltages\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired by the backplane to power monitoring cards and proximity transducers.\u003c\/p\u003e\n\u003cp\u003eBuilt for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical industrial environments\u003c\/strong\u003e, the 3300\/10-02-02-00 incorporates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadvanced line filtering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esurge suppression\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect sensitive monitoring electronics from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egrid fluctuations\u003c\/strong\u003e. This configuration is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-voltage AC inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(220 VAC) and includes an integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePower Input Module (PIM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat provides a secure, fused connection point for field wiring, ensuring that power transients do not compromise system integrity or signal reliability.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/10-02-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC Power Supply with Power Input Module (PIM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e175 to 250 VAC (Nominal 220 VAC), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegulated ±24 VDC and +5 VDC (System Backplane Voltages)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSufficient to drive a fully populated 3300 rack (up to 12 monitoring modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Connector Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard AC Power Input Module with Fuse Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Non-Hazardous \/ CSA\/NRTL\/C (General Purpose)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver-voltage protection, short-circuit current limiting, and EMI filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between primary AC input and DC secondary outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the primary power source for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 racks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower plants\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil refineries\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas processing facilities\u003c\/strong\u003e. It is essential for any facility using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e220V\/240V mains power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto energize their\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evibration\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethrust\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperature monitoring systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan this module be replaced while the rack is powered?\u003c\/h4\u003e\n\u003cp\u003eAlthough the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis robust, it is highly recommended to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ede-energize\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethe primary AC source before removing or installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/10-02-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epower supply to prevent arcing and ensure technician safety.\u003c\/p\u003e\n\u003ch4\u003eDoes this part include the rear Power Input Module (PIM)?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"-02\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoption in the configuration code specifies the inclusion of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePower Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e175–250 VAC range\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eWhat should I check if the 'Supply OK' LED is off?\u003c\/h4\u003e\n\u003cp\u003eFirst, verify the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary AC input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePIM terminals\u003c\/strong\u003e. If power is present, check the user-replaceable fuse located on the PIM. If the fuse is intact and the LED remains off, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal power conversion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas likely failed.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746762633468,"sku":"3300\/10-02-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330010-02-02-001.jpg?v=1772175918"},{"product_id":"bently-nevada-3300-series-3300-20-13-03-01-00-00-dual-thrust-position-monitor","title":"Bently Nevada 3300 Series 3300\/20-13-03-01-00-00 Dual Thrust Position Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300\/20-13-03-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability dual-channel monitoring module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 Machinery Protection System\u003c\/strong\u003e. It is primarily used to track the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaxial (thrust) position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof a rotating shaft relative to the thrust bearing clearance. By providing real-time data on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft displacement\u003c\/strong\u003e, this module acts as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical safety barrier\u003c\/strong\u003e, preventing catastrophic damage from rotor-to-stator contact or thrust bearing degradation.\u003c\/p\u003e\n\u003cp\u003eOptimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-axis monitoring\u003c\/strong\u003e, it processes signals from two independent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProximitor sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimultaneously. The 3300\/20-13-03-01-00-00 integrates seamlessly into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 rack backplane\u003c\/strong\u003e, providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elocal visual feedback\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia its front-panel meter and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote signal transmission\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor integration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDCS\/PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eepoxy-sealed relay design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures long-term contact integrity in harsh environments prone to corrosion and vibration.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/20-13-03-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMonitoring Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-Channel Axial Thrust Position\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25-0-25 mils (Standard range for thrust displacement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with 7200 14mm or 3300 HTPS Proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mV\/mil (Standard proximity probe sensitivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Relay Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relays for maximum environmental protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard non-hazardous \/ general-purpose configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThis module is essential for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed rotating equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbines\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentrifugal compressors\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge boiler feed pumps\u003c\/strong\u003e. It is the industry standard for protecting assets where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaxial movement beyond tolerances\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates imminent bearing failure or mechanical instability.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan I use this with standard 8mm Proximitor probes?\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/20-13-03-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically configured for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e14mm\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHTPS systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Option -03). For 8mm probes, a different transducer input option is required to ensure the correct linearization of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 mV\/mil\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003escale factor.\u003c\/p\u003e\n\u003ch4\u003eWhat is the benefit of the epoxy-sealed relay?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eepoxy-seal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprevents contaminants and moisture from oxidizing the relay contacts, increasing the reliability of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"Alert\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"Danger\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etrip circuits over extended service periods.\u003c\/p\u003e\n\u003ch4\u003eHow do I verify the sensor gap through this module?\u003c\/h4\u003e\n\u003cp\u003eYou can use the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebuffered output BNC connectors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the front of the module to measure the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC gap voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout disconnecting any field wiring. This provides an efficient way to verify the sensor gap during system setup or maintenance.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746763157756,"sku":"3300\/20-13-03-01-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330020-13-03-01-00-00_2.jpg?v=1772175918"},{"product_id":"bently-nevada-3300-55-03-14-14-14-00-00-07-00-dual-velocity-vibration-monitor","title":"Bently Nevada 3300\/55-03-14-14-14-00-00-07-00 Dual Velocity Vibration Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/55-03-14-14-14-00-00-07-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel seismic velocity monitoring module for the Bently Nevada 3300 System. It is designed to monitor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecasing vibration and structural vibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon rolling-element bearing machinery by measuring vibration velocity (rate of displacement change), which improves detection of mid-frequency mechanical faults.\u003c\/p\u003e\n\u003cp\u003eEach channel operates independently with built-in signal conditioning and alarm logic. The module also supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA analog outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor integration with DCS or PLC systems for continuous monitoring and data logging.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/55-03-14-14-14-00-00-07-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2 Independent Velocity Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e-10 VDC to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003eDual 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.7 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e10 Hz – 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint Adjustment\u003c\/td\u003e\n\u003ctd\u003eFront panel or internal jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C – 65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e9.50 × 4.50 × 1.00 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMotors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGeneral-purpose rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module is commonly used to detect\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elooseness, imbalance, and misalignment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the -14-14-14 configuration mean?\u003c\/strong\u003e\u003cbr\u003eIt defines measurement range and filtering parameters. This configuration is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–1.0 in\/s velocity scale\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emonitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it support accelerometers?\u003c\/strong\u003e\u003cbr\u003eNo. The 3300\/55 is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evelocity transducers\u003c\/strong\u003e. Accelerometer monitoring requires a different module such as a 3300\/50 series device.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746768302332,"sku":"3300\/55-03-14-14-14-00-00-07-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330055-03-04-14-14-00-00-07-001.jpg?v=1770789654"},{"product_id":"bently-nevada-3300-65-14-01-00-00-01-00-temperature-monitoring-module","title":"Bently Nevada 3300\/65-14-01-00-00-01-00 Temperature Monitoring Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/65-14-01-00-00-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel temperature monitoring module for the Bently Nevada 3300 System. It monitors\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebearing or process temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing RTD sensors to prevent overheating, lubricant breakdown, and mechanical deformation in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe module is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eslow-changing thermal parameters\u003c\/strong\u003e, featuring programmable alarm delays and voting logic to reduce false trips. Front panel LEDs indicate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK, Alert, and Danger\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estatus.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/65-14-01-00-00-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2 Independent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003e100Ω Platinum RTD (0.00385 \/ 0.00392)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 – 200°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"selectTdClass\"\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd class=\"selectTdClass\"\u003e1°C \/ 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003ctd\u003eDual SPDT epoxy-sealed relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VDC galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003eBackplane powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it support thermocouples?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-14 configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis hardware-coded for RTD inputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the -01 relay option?\u003c\/strong\u003e\u003cbr\u003eIt provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eepoxy-sealed relays\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor improved corrosion resistance and reliability in harsh environments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746768630012,"sku":"3300\/65-14-01-00-00-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-13-01-01-00-00-00_7a5230e6-6dd2-46b1-9aa2-e26610007386.jpg?v=1772090729"},{"product_id":"bently-nevada-3300-16-12-01-01-00-00-00-145323-01-dual-xy-gap-vibration-monitor","title":"Bently Nevada 3300\/16-12-01-01-00-00-00 145323-01 Dual XY\/Gap Vibration Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-12-01-01-00-00-00 (P\/N 145323-01)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel monitoring module designed for the Bently Nevada 3300 System rack-based machinery protection architecture.\u003c\/p\u003e\n\u003cp\u003eUnlike the earlier 3300\/15 series, this module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated XY radial vibration measurement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecombined with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft-to-probe gap voltage monitoring\u003c\/strong\u003e, allowing engineers to evaluate both dynamic rotor movement and static shaft positioning inside fluid-film bearings.\u003c\/p\u003e\n\u003cp\u003eEach channel operates independently and processes Proximitor sensor signals in real time. When vibration amplitudes or gap voltages exceed configured safety thresholds, the module triggers onboard relay-based hardware protection alarms to prevent mechanical damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Configuration \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-12-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e145323-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0–10 mils Peak-to-Peak displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 8mm, 3300 XL 8mm, 7200 5mm \/ 8mm Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Sensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (7.87 mV\/µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Hardware\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed SPDT relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Certifications\u003c\/td\u003e\n\u003ctd\u003eStandard version (non-approval variant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier Design\u003c\/td\u003e\n\u003ctd\u003eInternal isolation barriers not included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply Function\u003c\/td\u003e\n\u003ctd\u003eNot enabled (fixed setpoint logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Requirement\u003c\/td\u003e\n\u003ctd\u003eOccupies one full-height 3300 rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Outputs\u003c\/td\u003e\n\u003ctd\u003eFront-panel buffered coaxial diagnostic outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade (3300 platform standard environment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003ePrimary Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThis module is widely deployed in high-value rotating machinery protection systems, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge industrial cooling fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is particularly effective for detecting:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRotor imbalance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft misalignment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBearing wear and lubrication degradation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module provides orbit-style diagnostic capability by tracking shaft radial motion relative to the bearing clearance space.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 3300\/16-12-01-01-00-00-00 replace an old 3300\/15 monitor?\u003c\/strong\u003e\u003cbr\u003eYes. The 3300\/16 series is designed as a functional successor, maintaining the same rack footprint while improving gap alarm processing accuracy and signal stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of epoxy-sealed relays?\u003c\/strong\u003e\u003cbr\u003eEpoxy sealing protects relay contacts from corrosive gases, moisture, and chemical contaminants, making the module suitable for refinery and petrochemical environments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746768728316,"sku":"3300\/16-12-01-01-00-00-00 145323-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-12-01-01-00-00-00_145323-011.jpg?v=1772090728"},{"product_id":"3300-12-02-22-00-bently-nevada-machinery-protection-monitor","title":"3300\/12-02-22-00 Bently Nevada Machinery Protection Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/12-02-22-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision vibration and operational monitoring module designed for the Bently Nevada 3300 System rack platform. This module provides continuous machinery protection by monitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evibration levels and thrust position\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon critical rotating equipment.\u003c\/p\u003e\n\u003cp\u003eIt processes signals from Proximitor transducers and converts mechanical displacement and vibration dynamics into actionable control and diagnostic data for industrial automation and protection systems.\u003c\/p\u003e\n\u003cp\u003eThe module uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-channel architecture\u003c\/strong\u003e, allowing independent or redundant monitoring configurations. It also includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebuilt-in alert and danger setpoints\u003c\/strong\u003e, enabling immediate relay activation during abnormal vibration conditions to help prevent mechanical damage or catastrophic equipment failure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAC Operational \/ Vibration Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003e3300\/12-02-22-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kΩ (Proximitor signal standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003ePeak-to-Peak and RMS detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Configuration\u003c\/td\u003e\n\u003ctd\u003eDual alarm relays with programmable delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.5 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Display\u003c\/td\u003e\n\u003ctd\u003eLED bar graph channel status indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm × 12.4 cm × 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Applications\u003c\/h3\u003e\n\u003cp\u003eThis module is widely deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical and refinery plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy rotating machinery monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical equipment monitored includes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge industrial cooling fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module is used to capture\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradial and axial vibration behavior\u003c\/strong\u003e, helping maintain predictive maintenance workflows and safety compliance in high-energy mechanical environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eHardware FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 3300\/12-02-22-00 hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes. The module can be installed or removed from a powered 3300 rack without disrupting system operation, provided the rack supports modular maintenance procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the suffix options (-02-22-00) define hardware configuration?\u003c\/strong\u003e\u003cbr\u003eThese suffix codes define:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTransducer input configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement scale range\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAgency certifications (such as CSA or ATEX approvals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApplication-specific protection settings for different machinery environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746768761084,"sku":"3300\/12-02-22-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330012-02-22-001.jpg?v=1772090728"},{"product_id":"3300-16-11-01-01-00-01-02-bently-nevada-dual-monitor","title":"3300\/16-11-01-01-00-01-02 Bently Nevada Dual Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-11-01-01-00-01-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel radial vibration and gap voltage monitor designed for the Bently Nevada 3300 rack system. It measures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epeak-to-peak shaft vibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC gap voltage\u003c\/strong\u003e, enabling early detection of imbalance, misalignment, and bearing wear in rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThis configuration includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal safety barriers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSA\/NRTL\/C hazardous area approval\u003c\/strong\u003e, making it suitable for Class I, Div 2 environments. The front panel provides direct vibration and gap indication without external software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Number\u003c\/td\u003e\n\u003ctd\u003e3300\/16-11-01-01-00-01-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eDual proximity probe inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n\u003ctd\u003e5 mm \u0026amp; 8 mm Proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eRadial Vibration (Pk–Pk) \u0026amp; DC Gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Approval (01)\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C Class I, Div 2, Groups A–D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Barrier (01)\u003c\/td\u003e\n\u003ctd\u003eInternal intrinsic safety barriers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Option (01)\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed Alarm \u0026amp; Danger relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output (02)\u003c\/td\u003e\n\u003ctd\u003e0 to -10 Vdc proportional output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e4 Hz – 4,000 Hz (240–240,000 CPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal and axial compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBoiler feed and cooling water pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge gearboxes with sleeve bearings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the internal safety barrier (01)?\u003c\/strong\u003e\u003cbr\u003eIt limits field energy to prevent ignition in hazardous areas and removes the need for external barrier modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support XY orbit analysis?\u003c\/strong\u003e\u003cbr\u003eYes. With two probes mounted 90° apart, buffered outputs allow external orbit analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is “OK” status monitored?\u003c\/strong\u003e\u003cbr\u003eThe module continuously checks for open\/short circuits in probes and cables to prevent false trips due to sensor faults.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746769055996,"sku":"3300\/16-11-01-02-00-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-13-01-01-00-00-002_7f31015e-645a-4ff1-88f2-1a4b2bbb442a.jpg?v=1772090728"},{"product_id":"bently-nevada-3300-16-12-01-02-01-00-00-dual-channel-radial-vibration-monitor","title":"Bently Nevada 3300\/16-12-01-02-01-00-00 Dual Channel Radial Vibration Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-12-01-02-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel vibration monitoring module for the Bently Nevada 3300 machinery protection rack system. It processes proximity probe signals to continuously measure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradial vibration (peak-to-peak)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC gap voltage\u003c\/strong\u003e, providing early detection of imbalance, misalignment, and bearing wear.\u003c\/p\u003e\n\u003cp\u003eThe module features a front-panel display for simultaneous vibration and gap indication. Integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK self-check circuitry\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously monitors probe and extension cable integrity to prevent false trips due to sensor faults.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Order Code\u003c\/td\u003e\n\u003ctd\u003e3300\/16-12-01-02-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Type\u003c\/td\u003e\n\u003ctd\u003eRadial Vibration (Pk–Pk) \u0026amp; Gap Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eDual channel (independent or XY pair)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval (01)\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C Class I, Div 2, Groups A, B, C, D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntrinsic Safety (02)\u003c\/td\u003e\n\u003ctd\u003eExternal barriers included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Option (01)\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003e4–20 mA proportional output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of full scale at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e4 Hz – 4,000 Hz (240–240,000 CPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal pumps and compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial fans and blowers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge electric motors with fluid-film bearings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the “01” agency approval indicate?\u003c\/strong\u003e\u003cbr\u003eIt confirms CSA\/NRTL\/C certification for Class I, Div 2 hazardous locations in North America.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is gap voltage important?\u003c\/strong\u003e\u003cbr\u003eGap voltage reflects shaft position relative to the probe. Variations indicate bearing wear or shaft displacement, enabling predictive maintenance before vibration alarms occur.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746769350908,"sku":"3300\/16-12-01-02-00-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-12-01-02-01-02-001.jpg?v=1772090728"},{"product_id":"bently-nevada-3300-16-13-01-02-00-00-00-xy-gap-dual-vibration-monitor-module","title":"Bently Nevada 3300\/16-13-01-02-00-00-00 XY\/Gap Dual Vibration Monitor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-13-01-02-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel vibration monitor designed for the Bently Nevada 3300 Monitoring System by Baker Hughes - Bently Nevada.\u003c\/p\u003e\n\u003cp\u003eThis module processes signals from two proximity probes in an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eXY configuration\u003c\/strong\u003e, enabling accurate monitoring of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRadial vibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft orbit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC gap voltage (shaft position)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy reconstructing shaft motion, it helps detect rotor instability, misalignment, and bearing degradation in high-speed rotating equipment.\u003c\/p\u003e\n\u003cp\u003eThe unit includes an LCD display, LED status indicators, continuous transducer self-checking, and programmable protection relays to ensure reliable machinery protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Configuration\u003c\/td\u003e\n\u003ctd\u003e3300\/16-13-01-02-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003eDual-channel (XY or independent radial)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 5 mm, 8 mm, and 7200 Proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGap Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to -24 Vdc (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoints\u003c\/td\u003e\n\u003ctd\u003eAlert \u0026amp; Danger, 0.1–60 s delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e4–20 mA recorder + buffered outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eProgrammable protection relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed centrifugal compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and hydro turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge induction motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFluid-film bearing gearboxes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does XY monitoring differ from single radial measurement?\u003c\/strong\u003e\u003cbr\u003eTwo probes mounted 90° apart allow reconstruction of the shaft orbit, providing deeper insight into rotor dynamics than a single vibration channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy monitor gap voltage?\u003c\/strong\u003e\u003cbr\u003eGap voltage reflects shaft position relative to the bearing. Sudden or gradual shifts can indicate bearing wear or alignment problems before vibration alarms are triggered.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746769416444,"sku":"3300\/16-13-01-02-00-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-13-01-02-00-00-002.jpg?v=1772090729"},{"product_id":"tachometer-module-bently-nevada-3300-50-02-02-00-00","title":"Tachometer Module Bently Nevada 3300\/50-02-02-00-00","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/50-02-02-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a single-channel Rotor Acceleration Tachometer designed for the Bently Nevada 3300 Monitoring System platform by Baker Hughes - Bently Nevada.\u003c\/p\u003e\n\u003cp\u003eUnlike standard speed monitors, this configuration measures both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft speed (RPM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eangular acceleration\u003c\/strong\u003e, making it ideal for detecting:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZero-speed condition\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReverse rotation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcessive acceleration or deceleration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStartup and coast-down abnormalities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is widely used for turbine and compressor protection during critical operating phases.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Configuration\u003c\/td\u003e\n\u003ctd\u003e3300\/50-02-02-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Mode\u003c\/td\u003e\n\u003ctd\u003eRotor Acceleration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eHermetically sealed relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eProximitor or Magnetic Pickup (MPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA or 1–5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScaling\u003c\/td\u003e\n\u003ctd\u003eJumper configurable RPM \u0026amp; acceleration ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eFrequency-to-voltage conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm × 20.3 cm × 33.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and steam turbine startup monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor acceleration control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZero-speed verification before turning gear engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOverspeed and rapid load-change detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy monitor acceleration instead of only RPM?\u003c\/strong\u003e\u003cbr\u003eAcceleration monitoring detects abnormal rate-of-change conditions, such as startup hang-ups or sudden load drops, which may not be visible from steady-state RPM alone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eTrips should be bypassed before removal to avoid unintended machine shutdown due to loss of speed signal.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746769481980,"sku":"3300\/50-02-02-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330050-02-01-00-002.jpg?v=1770882488"},{"product_id":"3300-16-12-01-01-00-00-00-bently-nevada-dual-channel-proximity-probe-monitor","title":"3300\/16-12-01-01-00-00-00 Bently Nevada Dual Channel Proximity Probe Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-12-01-01-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel proximity probe monitor designed for the legacy Bently Nevada 3300 Monitoring System by Baker Hughes - Bently Nevada.\u003c\/p\u003e\n\u003cp\u003eThis module monitors\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradial vibration and DC gap voltage\u003c\/strong\u003e, providing essential protection data for rotating machinery. By tracking probe-to-shaft gap voltage, it helps detect:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBearing wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft position shift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStructural misalignment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical instability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAlert and Danger alarms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensure automatic protection, while front-panel bar graphs provide immediate visual status of vibration and gap levels.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Configuration\u003c\/td\u003e\n\u003ctd\u003e3300\/16-12-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Type\u003c\/td\u003e\n\u003ctd\u003eDual-channel radial vibration or average gap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003e5 mm and 8 mm Proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoints\u003c\/td\u003e\n\u003ctd\u003eAlert \u0026amp; Danger with 0.1–60 s delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Output\u003c\/td\u003e\n\u003ctd\u003e4–20 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eDual front-panel bar graphs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Source\u003c\/td\u003e\n\u003ctd\u003e3300 rack power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal and axial compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge motors and generators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed pumps and gearboxes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a “NOT OK” LED indicate?\u003c\/strong\u003e\u003cbr\u003eIt signals a transducer circuit fault such as a disconnected probe, damaged extension cable, or improper gap voltage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy monitor gap voltage?\u003c\/strong\u003e\u003cbr\u003eGap voltage represents probe-to-shaft distance. Changes can indicate bearing wear or alignment issues before vibration levels exceed alarm limits.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746769547516,"sku":"3300\/16-12-01-01-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-12-01-02-01-02-001.jpg?v=1772090728"},{"product_id":"bently-nevada-3300-16-13-01-01-00-00-00-dual-vibration-monitor","title":"Bently Nevada 3300\/16-13-01-01-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-13-01-01-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dual-channel radial vibration monitor designed for the legacy Bently Nevada 3300 Monitoring System platform by Baker Hughes - Bently Nevada.\u003c\/p\u003e\n\u003cp\u003eThis module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous real-time vibration monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing two independent proximity probe inputs. It converts transducer signals into direct vibration measurements, enabling early detection of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShaft misalignment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotor imbalance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBearing wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical looseness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIntegrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAlert and Danger alarm setpoints\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallow autonomous machinery protection. Front-panel displays provide immediate channel status and vibration level indication.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Order Code\u003c\/td\u003e\n\u003ctd\u003e3300\/16-13-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Type\u003c\/td\u003e\n\u003ctd\u003eDual-channel radial vibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Input\u003c\/td\u003e\n\u003ctd\u003e3300 \/ 3300 XL 8 mm proximity probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0–5 mils or 0–10 mils (jumper selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuffered Outputs\u003c\/td\u003e\n\u003ctd\u003eFront-panel coaxial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Configuration\u003c\/td\u003e\n\u003ctd\u003eProgrammable (NE\/ND)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eVia 3300 rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFluid-film bearing machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypically installed with:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 3300\/01 Rack Interface Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBently Nevada 3300\/10 Power Supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eto form a complete machinery protection system compliant with earlier API 670 standards.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a transducer fails?\u003c\/strong\u003e\u003cbr\u003eThe module includes a NOT OK detection circuit. If probe failure occurs, it activates a fault indication and inhibits alarm relays for that channel to prevent false trips.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan alarm setpoints be adjusted during operation?\u003c\/strong\u003e\u003cbr\u003eYes. Alert and Danger setpoints can be adjusted from the front panel using a calibration tool without interrupting protection.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746769580284,"sku":"3300\/16-13-01-01-00-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-13-01-01-00-00-001.jpg?v=1772090729"},{"product_id":"3300-16-14-01-01-00-00-00-bently-nevada-3300-16-vibration-monitoring-module","title":"3300\/16-14-01-01-00-00-00 Bently Nevada 3300\/16 Vibration Monitoring Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-14-01-01-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-channel vibration and position monitoring module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by Bently Nevada LLC for use in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emachinery protection system.\u003c\/p\u003e\n\u003cp\u003eThis module provides continuous real-time monitoring of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradial vibration amplitude\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft gap (axial position)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing proximity probe transducers. It is widely used as an early-warning protection layer for rotating equipment such as turbines, compressors, and large industrial pumps.\u003c\/p\u003e\n\u003cp\u003eEach channel operates independently and features advanced signal conditioning circuitry to ensure high measurement accuracy and long-term stability. The module also includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTrip Multiply logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent false alarms during startup or transient machine conditions. The epoxy-sealed relay outputs provide reliable switching performance in harsh industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/16-14-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel vibration \u0026amp; gap monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 rack system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1–2 proximity probe inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensitivity Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mV\/mil (4 V\/mm) 200 mV\/mil (8 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Accuracy (@25°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.33% typical ±1.0% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine rotor monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressor protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump shaft alignment and bearing wear detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial rotating machinery condition monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is there a 6-second gap alarm delay?\u003c\/strong\u003e\u003cbr\u003eThe delay prevents false alarms caused by transient vibration or signal noise during machine start-up or temporary disturbances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan non-Bently probes be used?\u003c\/strong\u003e\u003cbr\u003eYes, provided the probe output meets the module’s voltage and sensitivity requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs sensitivity hardware-fixed?\u003c\/strong\u003e\u003cbr\u003eNo. Sensitivity is software or configuration programmable to support different machine setups.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746769613052,"sku":"3300\/16-14-01-01-00-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-14-01-01-00-00-00_2.jpg?v=1772006490"},{"product_id":"monitoring-system-rack-bently-nevada-3300-05-22-00-00","title":"Monitoring System Rack Bently Nevada 3300\/05-22-00-00","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/05-22-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a central rack chassis for the Bently Nevada machinery protection system. It provides the structural and electrical backbone for 3300 monitor modules, enabling power distribution, signal routing, and high-speed inter-module communication. Designed for demanding industrial environments, this rack supports vibration, position, speed, and temperature monitoring modules, making it a versatile solution for rotating machinery protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003e3300\/05-22-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Configuration\u003c\/td\u003e\n\u003ctd\u003e19-inch standard rack mount (14 slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Architecture\u003c\/td\u003e\n\u003ctd\u003eIntegrated high-speed data bus for module communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Support\u003c\/td\u003e\n\u003ctd\u003eCompatible with integrated 3300 power supply modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty aluminum and steel alloy for EMI\/RFI shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Options (-22)\u003c\/td\u003e\n\u003ctd\u003e19-inch rack with front access\/rear terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style (-00)\u003c\/td\u003e\n\u003ctd\u003eStandard panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals (-00)\u003c\/td\u003e\n\u003ctd\u003eStandard certifications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Profile\u003c\/td\u003e\n\u003ctd\u003e3300\/05 System Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e27.9 × 45.7 × 58.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.7 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Versatility \u0026amp; Scalability\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModular design allows expansion by adding additional monitor modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports multi-channel monitoring, including vibration, axial position, eccentricity, and casing expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCommonly used in power plants, refineries, and industrial facilities to protect turbines, compressors, and large pumps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this rack include monitor modules?\u003c\/strong\u003e\u003cbr\u003eNo, the 3300\/05-22-00-00 is an empty chassis. Modules, power supplies, and System Display Panels (SDPs) must be ordered separately.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the '-22' option signify?\u003c\/strong\u003e\u003cbr\u003eThe '-22' code denotes a 19-inch rack with standard rear-terminal access for field wiring connections.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746806214908,"sku":"3300\/05-22-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330005_22_00_00.jpg?v=1770882488"},{"product_id":"bently-nevada-3300-05-24-00-00-machinery-protection-system-rack-chassis","title":"Bently Nevada 3300\/05-24-00-00 Machinery Protection System Rack Chassis","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/05-24-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10-slot modular chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bently Nevada 3300 Monitoring System, providing the structural and electrical backbone for machinery protection. It integrates power distribution and signal routing across all installed modules, ensuring reliable system operation with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eno-internal-wiring design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor rapid installation and maintenance.\u003c\/p\u003e\n\u003cp\u003eConstructed from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econductive, anti-static injection-molded plastic\u003c\/strong\u003e, the chassis protects sensitive electronics from ESD while maintaining optimal mechanical rigidity. The layout prioritizes power and system monitoring in the first two slots, leaving eight positions available for additional vibration, thrust, or temperature monitoring modules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/05-24-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductive anti-static injection-molded plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated backplane (no internal rack wiring required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLabeling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBezel tag and clear identification strip support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (-4°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe 3300\/05-24-00-00 is commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine halls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater treatment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt serves as the central platform for monitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle large turbine trains\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor clusters of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eauxiliary pumps and compressors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eRack System FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I place a vibration monitor in Slot 1 or 2?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNo. Slot 1 is reserved for the Power Supply (3300\/12) and Slot 2 for the System Monitor (3300\/01). All monitoring modules must start from Slot 3.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIs this rack compatible with 3500 Series modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNo. The 3300\/05-24-00-00 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexclusively compatible with the 3300 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand is physically\/electrically incompatible with 3500 series modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746806509820,"sku":"3300\/05-24-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330005_24_00_00.jpg?v=1770882488"},{"product_id":"bently-nevada-3300-12-power-supply-module-3300-series","title":"Bently Nevada 3300\/12 Power Supply Module 3300 Series","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary power supply module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bently Nevada 3300 Machinery Protection System (MPS). It converts facility AC line power into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eregulated DC voltages\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the rack backplane, providing stable, low-noise power to all connected vibration, thrust, and temperature monitors.\u003c\/p\u003e\n\u003cp\u003eEquipped with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esurge protection, EMI filtering, and diagnostic LEDs\u003c\/strong\u003e, the 3300\/12 ensures uninterrupted machinery protection logic, even under line fluctuations. It is essential for any 3300 series installation and occupies the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated power slot\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the system rack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115 VAC (85–132 VAC) or 230 VAC (170–264 VAC), 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRegulated DC for rack backplane (+5 VDC, -24 VDC, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSurge Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMetal-oxide varistors (MOVs) and line filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFront Panel Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePower \"ON\" LED; System \"OK\" status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Tolerance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous industrial operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 cm x 20 cm x 33 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated power supply slot in 3300 rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebackplane power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor all Bently Nevada 3300 modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUsed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine, compressor, and pump protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross petrochemical, power generation, and industrial facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActs as the foundation for machinery protection logic in critical equipment monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eReliability FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan redundant power supplies be used in a 3300 rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe 3300\/12 is designed for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle module per rack\u003c\/strong\u003e. For critical applications, external UPS systems are recommended to maintain stable AC input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if an internal fuse blows?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUser-replaceable fuses are located behind the front panel. If a fuse fails:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePower LED turns off\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSystem OK relay changes state\u003c\/strong\u003e, alerting the control room that protection for the rack is compromised.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746806575356,"sku":"3300\/12","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/3300122_01a96cc3-57e8-4fc4-aaee-dc3e954723aa.jpg?v=1770882488"},{"product_id":"dual-vibration-monitor-bently-nevada-3300-15-03-01-01-00-00-00","title":"Dual Vibration Monitor Bently Nevada 3300\/15-03-01-01-00-00-00","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/15-03-01-01-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-channel radial vibration monitoring module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the Bently Nevada 3300 series. It converts raw eddy current probe signals into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-accuracy digital and analog outputs\u003c\/strong\u003e, enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time detection of shaft imbalance, misalignment, or bearing wear\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elocal front-panel display\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor immediate operator feedback and is compatible with legacy high-sensitivity proximity systems. Its hardware-centric architecture ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous machinery protection\u003c\/strong\u003e, even if external networks fail.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/15-03-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel radial shaft vibration monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated front-panel digital readout (RPM \u0026amp; vibration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–10 mils peak-to-peak (PP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA DC proportional signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCalibrated for 7200 mV\/mm (high-sensitivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 Monitoring Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent Alert and Danger setpoints per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternally regulated for Proximity Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (via rack backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower generation turbines\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCentrifugal compressors\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLarge motor-driven fans\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; gas machinery\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMining industry equipment\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIdeal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-sensitivity displacement monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fluid-film bearing systems, where early detection of vibration changes prevents catastrophic failure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the 7200 mV\/mm scale factor important?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIt allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eextremely fine-resolution detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof shaft movement, essential for precision machinery using high-sensitivity sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 4–20 mA output work with the front-panel display?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edisplay provides local, real-time readings\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor on-site troubleshooting, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA output transmits the same signal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto DCS or PLC systems for long-term trend logging and remote monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746809262332,"sku":"3300\/15-03-01-01-00-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-14-01-03-00-00-00_1.jpg?v=1770882488"},{"product_id":"bently-nevada-3300-16-14-01-03-00-00-00-dual-vibration-monitor","title":"Bently Nevada 3300\/16-14-01-03-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-14-01-03-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-channel radial vibration and shaft gap monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bently Nevada 3300 rack system. It continuously monitors\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eradial shaft vibration and average gap voltage\u003c\/strong\u003e, providing early detection of mechanical issues such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eunbalance, misalignment, or bearing clearance changes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis configuration is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elegacy 7200 series Proximitor sensors\u003c\/strong\u003e, with a sensitivity of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e200 mV\/mil\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a measurement range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–10 mils peak-to-peak\u003c\/strong\u003e. Epoxy-sealed alarm relays ensure robust operation in harsh industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/16-14-01-03-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel radial vibration \u0026amp; shaft gap monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–10 mils peak-to-peak (pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 7200 Series Proximitor (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Hz – 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC per channel for PLC\/DCS integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed Alert and Danger relays (Option -03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (via system backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTurbine Supervisory Instrumentation (TSI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein power plants, pumping stations, and refineries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentrifugal compressors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand large fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBridging\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eolder 7200 series sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith modern 4–20 mA control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for harsh environments or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-climate-controlled rack installations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eHardware Compatibility FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is 200 mV\/mil sensitivity important?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures accurate 0–10 mils monitoring when using legacy 7200 series Proximitor sensors. Using sensors with different scale factors requires verification of gap voltage and linearity to maintain measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the epoxy-sealed relay option provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtects the relays from moisture and atmospheric contaminants, increasing reliability in harsh or industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746809524476,"sku":"3300\/16-14-01-03-00-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-14-01-03-00-00-00_1.jpg?v=1770882488"},{"product_id":"bently-nevada-3300-16-15-01-01-00-00-01-dual-vibration-monitor","title":"Bently Nevada 3300\/16-15-01-01-00-00-01 Dual Vibration Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-15-01-01-00-00-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-channel radial vibration and shaft position monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the Bently Nevada 3300 rack system. It converts signals from proximity probes into precise displacement measurements, enabling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time detection of imbalance, misalignment, or bearing wear\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis module is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0–10 mils peak-to-peak full-scale range\u003c\/strong\u003e, making it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge fluid-film bearing machines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as steam turbines, centrifugal compressors, and industrial fans. With a response latency under\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 millisecond\u003c\/strong\u003e, it ensures rapid trip signals to prevent catastrophic equipment damage.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/16-15-01-01-00-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadial shaft vibration and axial position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–10 mils peak-to-peak (pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTwo independent channels for Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBently Nevada 3300 (5mm) \u0026amp; 3300 XL (8mm) Proximity Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProximitor Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-17.5 VDC to -26 VDC with non-incendive protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC for PLC\/DCS integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Latency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 ms for alarm\/trip activation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 12 mA per transducer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.8 × 20.3 × 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine Supervisory Instrumentation (TSI) in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower plants\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil refineries and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing facilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efluid-film bearing machines\u003c\/strong\u003e, including large\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentrifugal compressors\u003c\/strong\u003e, steam turbines, and industrial fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eearly detection of radial shaft movement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent equipment failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module work with older 7200 series Proximitor sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYes. It is backward compatible, provided the scale factor (mV\/mil) is correctly calibrated to match the monitor’s input range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow does supply voltage affect measurement accuracy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for a -24 V supply. Operating above -23 V may reduce the linear range of the proximity probe and affect high-vibration measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746809786620,"sku":"3300\/16-15-01-01-00-00-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330016-15-01-01-00-00-01.jpg?v=1770882488"},{"product_id":"3300-16-15-01-03-00-00-02-bently-nevada-dual-vibration-monitor","title":"3300\/16-15-01-03-00-00-02 Bently Nevada Dual Vibration Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/16-15-01-03-00-00-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-channel radial vibration monitoring module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bently Nevada 3300 rack system. It is engineered to provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-accuracy displacement measurements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom proximity (eddy current) transducers. This module is critical for machinery protection on high-speed, fluid-film bearing assets, enabling real-time monitoring of shaft movement and preventing rotor-to-stator contact.\u003c\/p\u003e\n\u003cp\u003eThe “15” option denotes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDanger Bypass\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eInternal Termination\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecapabilities, allowing safe testing and calibration without initiating trips. Its dual-channel design supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eXY radial pairs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo independent radial measurement points\u003c\/strong\u003e, making it ideal for orbit analysis and early detection of unbalance, misalignment, or oil whirl conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/16-15-01-03-00-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRadial Vibration (Displacement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 \/ 3300 XL Proximitor Systems (5mm, 8mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independent channels (XY or dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–200 µm or 0–5 mil peak-to-peak (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel relays, epoxy\/hermetic sealed (Option -03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 4-20 mA for DCS\/PLC integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Hz – 4000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge motor-driven pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas, power generation, and chemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis module allows operators to observe shaft orbits and monitor vibration trends in real time, providing critical protection against catastrophic rotor-to-stator contact.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eReliability \u0026amp; Operational FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the Danger Bypass feature do?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAllows testing or calibration of sensors without initiating a machine trip. This ensures safe maintenance while the machine remains online.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module include self-diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYes. The built-in “NOT OK” circuitry continuously monitors transducer bias. If a sensor fails or a cable disconnects, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOK LED turns off\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the alarm\/trip relays are inhibited to prevent false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy use dual-channel monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnables XY shaft orbit analysis or redundant measurements at separate points, improving fault detection and machinery protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746810081532,"sku":"3300\/16-15-01-03-00-00-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330050-02-01-00-002.jpg?v=1770882488"},{"product_id":"bently-nevada-3300-20-12-01-dual-thrust-position-monitor","title":"Bently Nevada 3300\/20-12-01 Dual Thrust Position Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/20-12-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-channel axial thrust position monitoring module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the Bently Nevada 3300 series. It is specifically designed to track the rotor’s axial position relative to thrust bearings in critical machinery such as steam turbines, centrifugal compressors, and multi-stage pumps. By providing continuous monitoring and integrated alarm\/trip logic, this module acts as a primary protection layer to prevent mechanical damage caused by axial misalignment or bearing failure.\u003c\/p\u003e\n\u003cp\u003eThe 3300\/20-12-01 processes signals from Proximitor transducers, offering high-precision measurements and configurable full-scale ranges. Its fast response and diagnostic features ensure reliable detection of abnormal axial movement and safeguard high-value rotating assets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/20-12-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel axial thrust position monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 \/ 3300 XL Proximitor Systems (5mm, 8mm, 11mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically -1.0 to +1.0 mm (-40 to +40 mils), configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03 mm (±1.1 mils) at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Options\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 4-20 mA DC analog outputs; Alert and Danger relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 ms for alarm\/trip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +65°C (-4°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-stage pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTurbo-expanders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis module is essential for detecting abnormal axial loads caused by process changes, lubricant contamination, or surge conditions, enabling preventative shutdown before mechanical failure.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eThrust Monitoring FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of dual-channel monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual-channel modules can operate in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoting mode\u003c\/strong\u003e, requiring agreement from both channels before issuing a trip. This reduces false trips caused by a single sensor or wiring fault.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module respond to transducer failure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated self-diagnostics illuminate a “Not OK” LED if the Proximitor signal goes out of range (short\/open\/failure) and inhibit alarms to prevent false trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is fast response time important?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWith \u0026lt;100 ms trip capability, the 3300\/20-12-01 ensures immediate protective action against rapid axial excursions, preserving rotor and bearing integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746810114300,"sku":"3300\/20-12-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330020-12-012.jpg?v=1770882488"},{"product_id":"dual-differential-expansion-bently-nevada-3300-45-02-01-03-00","title":"Dual Differential Expansion Bently Nevada 3300\/45-02-01-03-00","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/45-02-01-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision dual-channel differential expansion monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the Bently Nevada 3300 series. It measures the relative axial displacement between a turbine rotor and its stationary casing, ensuring that thermal expansion does not compromise internal clearances. This module is critical for turbine supervisory instrumentation (TSI), preventing mechanical contact and structural damage during startup and operation.\u003c\/p\u003e\n\u003cp\u003eIt converts analog signals from proximity transducers into precise digital data and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA outputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor integration with PLCs or DCS systems. Designed for continuous industrial operation, the module includes robust diagnostics and configurable alarm setpoints.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Order Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45-02-01-03-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-Channel Differential Expansion Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypical: 0.33% FS \/ Max: ±1.0% FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC proportional output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigitally adjustable setpoints (0–100% FS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (via 3300 system rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring axial clearances in HP and IP turbine sections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time supervision during turbine startup and thermal ramp-up\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration into Turbine Supervisory Instrumentation (TSI) for critical assets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreventing rotor-to-stator contact and reducing unplanned downtime\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDifferential Expansion FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does it assist during turbine startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe rotor expands faster than the casing during heat-up. The module monitors the gap in real-time and triggers alarms or trip outputs if limits are exceeded.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"-03\" designation indicate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSpecifies the relay configuration, often including hermetically or epoxy-sealed high-reliability relays for alarm and trip outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746810441980,"sku":"3300\/45-02-01-03-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330045-02-01-03-002.jpg?v=1770882488"},{"product_id":"bently-nevada-3300-45-02-02-03-00-differential-expansion-monitoring-module","title":"Bently Nevada 3300\/45-02-02-03-00 Differential Expansion Monitoring Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/45-02-02-03-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-integrity dual-channel differential expansion monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bently Nevada 3300 series rack system. It is specifically engineered to measure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eaxial displacement between a turbine rotor and its casing\u003c\/strong\u003e, providing critical protection during thermal expansion and load transients. By continuously tracking relative movement, the module prevents internal contact between rotating blades and stationary components, ensuring operational safety and machinery longevity.\u003c\/p\u003e\n\u003cp\u003eThis configuration supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant or multi-point measurements\u003c\/strong\u003e, with field-programmable voting logic and high-reliability relay outputs for interfacing with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eemergency shutdown systems (ESD)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/45-02-02-03-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDifferential expansion monitoring (rotor vs. stator)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 mm, 11 mm, and 25 mm Proximitor systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independent channels (dual-channel monitoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull-Scale Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable: ±2.0 mm to ±10 mm (custom configurations possible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of full-scale range at room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-reliability hermetically or epoxy-sealed relays (Configuration -03)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +65°C (-4°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAxial displacement monitoring in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(HP \u0026amp; LP sections)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsuring rotor blades do not contact stationary diaphragms during startup or thermal ramps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial compressors or other rotating machinery with significant thermal growth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant monitoring setups where safety and early warning are critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFunctional FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy use dual-channel monitoring instead of single-channel?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual channels provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant or complementary data\u003c\/strong\u003e, enabling 2-out-of-2 voting logic to prevent nuisance trips caused by a single sensor failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffers a complete picture of rotor axial movement for enhanced turbine protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCan the full-scale range be adjusted after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYes, the module supports adjustable full-scale ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjusting the range requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erecalibration of Proximitor sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand verification of the voltage-to-displacement slope to maintain measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746810573052,"sku":"3300\/45-02-02-03-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330045-02-01-03-001.jpg?v=1770882488"},{"product_id":"bently-nevada-3300-48-01-01-01-00-xl-nsv-case-expansion-monitor","title":"Bently Nevada 3300\/48-01-01-01-00 XL NSv Case Expansion Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/48-01-01-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision thermal growth monitoring module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to interface with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL NSv proximity transducers\u003c\/strong\u003e. Unlike standard LVDT-based expansion monitors, this module translates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNSv sensor feedback\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto actionable data for machinery protection and supervisory control. It is ideal for turbine supervisory instrumentation (TSI) applications where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espace constraints\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor specialized sensor requirements exist.\u003c\/p\u003e\n\u003cp\u003eBy continuously tracking casing displacement relative to the foundation, the 3300\/48-01-01-01-00 helps prevent mechanical misalignment, vibration, and structural stress in rotating machinery.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/48-01-01-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Technology\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300 XL NSv Proximity Transducer Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-channel per module slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±50 µm (±0.002 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC proportional to expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Latency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (via 3300 backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\/Sealing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRuggedized for high humidity (95% RH non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-precision thermal monitoring of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand specialized rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300 XL NSv sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealready used for vibration or thrust monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econfined spaces\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere LVDTs are impractical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports turbine supervisory instrumentation (TSI) in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation plants and industrial facilities\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eComparison \u0026amp; Functional FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this NSv version differ from standard 3300\/48?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eStandard 3300\/48 modules typically interface with LVDTs for long-stroke measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe 3300\/48-01-01-01-00 is tuned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshort-range, high-precision NSv proximity sensors\u003c\/strong\u003e, ideal for confined installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the sensor signal is lost?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe module performs\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal self-diagnostics\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoss of signal or cable failure triggers the \"OK\" LED to extinguish, and the 4–20 mA output drops below 3.6 mA to alert the control system of a loop integrity issue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746810900732,"sku":"3300\/48-01-01-01-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330050-02-01-00-002.jpg?v=1770882488"},{"product_id":"3300-48-02-01-00-00-bently-nevada-case-expansion-monitor","title":"3300\/48-02-01-00-00 Bently Nevada Case Expansion Monitor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/48-02-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision thermal growth monitoring module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Bently Nevada 3300 rack system. It is specifically designed to track\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emachine case expansion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein large steam turbines, ensuring that thermal growth occurs within safe mechanical tolerances during startup and operation.\u003c\/p\u003e\n\u003cp\u003eBy monitoring the differential or absolute movement of turbine housings, this module helps prevent structural stress, misalignment, or binding of rotating components. It converts measurements from LVDT transducers into reliable electrical signals compatible with the 3300 rack system, enabling timely alerts and integration with supervisory control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/48-02-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eThermal case expansion monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 independent LVDT transducer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 25 mm (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA proportional signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–36 VDC (via 3300 rack backplane, nominal 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +65°C (-4°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent Alert and Danger setpoints per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Conditioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in transducer health monitoring (OK\/Fault)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHP and IP steam turbine sections\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsuring turbine casing can\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexpand freely\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring startup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreventing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical rubbing or misalignment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edue to stuck or uneven expansion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrating with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emachine protection logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor turbine supervisory systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFunctional FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is case expansion monitoring critical during turbine startup?\u003c\/strong\u003e\u003cbr\u003eDifferent turbine components heat at different rates. If the casing does not expand correctly (e.g., a lubricated slide is stuck), it can cause internal rubbing, misalignment, or structural stress. The 3300\/48-02-01-00-00 alerts operators before damage occurs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module support dual-sensor voting?\u003c\/strong\u003e\u003cbr\u003eThe module provides two independent channels, typically for monitoring two separate points (e.g., left and right sides). The 3300 rack can implement logic schemes using these signals for comprehensive turbine protection.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746810966268,"sku":"3300\/48-02-01-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330048-02-01-00-00.jpg?v=1770882488"},{"product_id":"tachometer-monitoring-and-protection-module-bently-nevada-3300-50-01-01-00-00","title":"Tachometer Monitoring and Protection Module Bently Nevada 3300\/50-01-01-00-00","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/50-01-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance speed monitoring module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein the Bently Nevada 3300 series rack system. It provides continuous, real-time measurement of shaft\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erotational speed\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eacceleration\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero-speed state\u003c\/strong\u003e, serving as a critical safety and monitoring device for high-speed rotating machinery.\u003c\/p\u003e\n\u003cp\u003eEquipped with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual setpoints (Alert and Danger)\u003c\/strong\u003e, this module can trigger alarms and trips automatically based on configurable velocity thresholds. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-20 mA proportional output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures seamless integration with PLCs, DCSs, or other supervisory systems, while high-speed processing enables detection of transient speed changes in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eless than 1 millisecond\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/50-01-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRPM, acceleration, zero-speed detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual independent transducer channels (Proximitor or magnetic pickups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4-20 mA proportional to speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarming\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual adjustable setpoints with front-panel LED indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Latency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC via 3300 System Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +65°C (-4°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.1 cm × 20.3 cm × 33.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge industrial pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIdeal for applications requiring:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRapid acceleration monitoring during startup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eZero-speed permissive signals for maintenance safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed, hardware-level monitoring independent of PLC scan latency\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFunctional FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module differ from PLC-based speed counting?\u003c\/strong\u003e\u003cbr\u003eUnlike PLC modules, which can suffer from scan-time latency, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/50-01-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates at a dedicated hardware level with sub-millisecond response, ensuring fast and reliable trip activation during overspeed or rapid acceleration events.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module output data to both local and remote systems?\u003c\/strong\u003e\u003cbr\u003eYes. It provides a local digital display on the rack front panel and simultaneously sends a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous 4-20 mA signal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto remote DCS or PLC systems for monitoring, logging, and redundancy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746811064572,"sku":"3300\/50-01-01-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330050-02-01-00-002.jpg?v=1770882488"},{"product_id":"3300-50-02-01-00-00-bently-nevada-tachometer-speed-module","title":"3300\/50-02-01-00-00 Bently Nevada Tachometer Speed Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/50-02-01-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed monitoring interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3300 rack system\u003c\/strong\u003e. This module provides real-time rotational velocity and acceleration data, forming a critical safety layer for high-speed industrial machinery.\u003c\/p\u003e\n\u003cp\u003eIn addition to standard RPM measurement, the 3300\/50 is engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero-speed detection\u003c\/strong\u003e, enabling maintenance personnel to safely engage equipment only when it is confirmed fully stopped.\u003c\/p\u003e\n\u003cp\u003eEquipped with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo independent transducer inputs\u003c\/strong\u003e, it processes signals from proximity probes or magnetic pickups with sub-millisecond latency. The rugged circuitry is designed to resist electromagnetic interference, ensuring reliable pulse-to-digital conversion for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDCS and PLC integration\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/50-02-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Functions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRotational speed, acceleration, and zero-speed monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-channel independent transducer inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProximity probes (eddy current) or magnetic pickups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Response Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1 millisecond\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC via rack backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-fidelity pulse counting for precise RPM readout\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +65°C (-4°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.2 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and steam turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge centrifugal compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReciprocating engines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is critical for applications requiring:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eZero-speed verification for turning gear engagement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRapid acceleration monitoring to prevent mechanical overstress\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRedundant sensor operation for high-availability systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does zero-speed detection work?\u003c\/strong\u003e\u003cbr\u003eThe module monitors the interval between pulses. If no pulse is detected within a predefined threshold, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero-speed status\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis activated, which can serve as a permissive input for safety interlocks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module support redundant transducer configurations?\u003c\/strong\u003e\u003cbr\u003eYes. With\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo independent channels\u003c\/strong\u003e, the 3300\/50 allows redundant sensor setups, ensuring that a single probe failure does not compromise speed monitoring.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746811162876,"sku":"3300\/50-02-01-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330050-02-01-00-002.jpg?v=1770882488"},{"product_id":"bently-nevada-3300-53-03-02-00-60-05-00-00-00-overspeed-detection-module","title":"Bently Nevada 3300\/53-03-02-00-60-05-00-00-00 Overspeed Detection Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/53-03-02-00-60-05-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOverspeed Detection Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the Bently Nevada 3300 Machinery Protection System.\u003c\/p\u003e\n\u003cp\u003eThis module continuously monitors rotational speed inputs from proximity probes or magnetic pickups installed on critical rotating equipment such as steam turbines, gas turbines, and large centrifugal compressors. It functions as an independent safety layer, providing autonomous overspeed protection even if communication with the primary DCS is lost.\u003c\/p\u003e\n\u003cp\u003eDesigned for rapid response, the 3300\/53 can initiate emergency trip signals within milliseconds once a configured speed threshold is exceeded. Its hardware-centric architecture ensures reliable operation in high-vibration, high-energy industrial environments.\u003c\/p\u003e\n\u003cp\u003eMulti-channel input and voting logic capabilities (e.g., 2-out-of-3 configuration) significantly enhance system safety by minimizing nuisance trips while maintaining overspeed protection integrity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3300\/53-03-02-00-60-05-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOverspeed Detection \u0026amp; Protection Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 or 3 channels (Proximity Probes or Magnetic Pickups)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 – 99,999 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 rpm (≤10,000 rpm); ±0.01% (\u0026gt;10,000 rpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.017 Hz – 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 50 ms (typical trip activation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIndependent Alert and Danger (Trip) relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransducer Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc (standard Bently Nevada sensors)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoting Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMulti-channel support (e.g., 2-out-of-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Suitability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesigned for high-vibration rotating machinery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/53-03-02-00-60-05-00-00-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine overspeed protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine generator sets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge centrifugal compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHydroelectric turbine-generator units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-inertia industrial fans and pumps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is considered an industry-standard safety module for protecting high-value rotating assets from catastrophic mechanical failure caused by overspeed events.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eMachinery Safety FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the voting logic improve safety?\u003c\/strong\u003e\u003cbr\u003eThe module supports configurable voting schemes such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-out-of-3 (2oo3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elogic. In this configuration, at least two independent speed channels must detect an overspeed condition before the trip relay is activated. This reduces false trips caused by a single sensor fault while maintaining protection integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan speed setpoints be adjusted during operation?\u003c\/strong\u003e\u003cbr\u003eAlthough monitoring remains active continuously, setpoint adjustments and self-tests are typically performed via the 3300 rack interface or configuration tool during scheduled maintenance to prevent unintended trip activation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746811490556,"sku":"3300\/53-03-02-00-60-05-00-00-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330053-03-02-00-60-05-00-00-00.jpg?v=1770882488"},{"product_id":"3300-55-03-04-14-14-00-00-07-00-bently-nevada-dual-velocity-monitor","title":"3300\/55-03-04-14-14-00-00-07-00 Bently Nevada Dual Velocity Monitor","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/55-03-04-14-14-00-00-07-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erack-mounted dual-channel velocity monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for continuous monitoring of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eabsolute machinery casing vibration\u003c\/strong\u003e. It processes signals from velocity transducers to provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time vibration data\u003c\/strong\u003e, enabling early detection of mechanical faults in rotating equipment such as pumps, motors, and fans. Its outputs are compatible with PLCs, DCS systems, or analog recorders, making it ideal for preventive maintenance and machinery protection in industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries \/ Model\u003c\/td\u003e\n\u003ctd\u003e3300\/55-03-04-14-14-00-00-07-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Type\u003c\/td\u003e\n\u003ctd\u003eDual-channel Absolute Velocity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Input Range\u003c\/td\u003e\n\u003ctd\u003e-10 VDC to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Range\u003c\/td\u003e\n\u003ctd\u003e0 – 1.0 in\/s (25.4 mm\/s) Peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Transducers\u003c\/td\u003e\n\u003ctd\u003e330500 Velomitor or standard 2-wire\/3-wire velocity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Setpoints\u003c\/td\u003e\n\u003ctd\u003eIndividually adjustable Alert \u0026amp; Danger for each channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecorder Outputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC (internally powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approvals\u003c\/td\u003e\n\u003ctd\u003eCSA\/NRTL\/C (Class 1, Div 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +65°C (+32°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e241 × 114 × 25 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eFunctional Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Independent Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel has dedicated OK LEDs to indicate transducer health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConfigurable \"Danger\" relays for latching or non-latching operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRecorder Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4–20 mA analog outputs allow seamless integration with PLCs, DCS, or chart recorders.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Friendly:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIncludes bypass switches for individual channel servicing without shutting down the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCSA\/NRTL\/C certified for Class 1, Div 2 environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support metric units?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe standard configuration is scaled in inches per second (in\/s). Metric scaling (mm\/s) is available through optional configurations or by adjusting internal scale factors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this with accelerometers instead of velocity sensors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNo. This module is specifically filtered and calibrated for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evelocity signals\u003c\/strong\u003e. For acceleration monitoring, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3300\/50 Dual Accelerometer Monitor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould be used.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the recorder output powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe 4–20 mA recorder output is internally powered by the module, eliminating the need for external loop power for standard analog monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48746811785468,"sku":"3300\/55-03-04-14-14-00-00-07-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/330055-03-04-14-14-00-00-07-001.jpg?v=1770789654"},{"product_id":"bently-nevada-3300-16-13-01-00-00-00-00-dual-vibration-xy-gap-monitor","title":"Bently Nevada 3300\/16-15-01-01-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 3300\/16 Dual Vibration Monitor is a rack-mounted module designed to measure radial shaft vibration in critical rotating machinery, such as turbines and compressors. The 15 suffix option specifies a dual-channel XY vibration configuration, enabling simultaneous monitoring of two orthogonal vibration signals. This monitor continuously compares vibration parameters against user-defined alarm setpoints, providing early warning of mechanical issues and supporting predictive maintenance strategies.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual-channel XY vibration monitoring for comprehensive shaft analysis.\u003c\/li\u003e\n\u003cli\u003eContinuous signal conditioning and comparison against Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eStandard relay outputs for alarm annunciation.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Bently Nevada proximity probe and Proximitor sensor systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis module is primarily used in industrial protection systems for monitoring radial vibration on rotating shafts in power generation, oil and gas, and petrochemical facilities. It is designed for integration into the Bently Nevada 3300 Monitoring System rack.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-15-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical, +\/- 1% max at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot and that the front panel screws are tightened to ensure proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper ventilation within the cabinet to maintain the operating temperature between 0 and 60 degC.\u003c\/li\u003e\n\u003cli\u003eHandle with ESD-safe precautions to protect sensitive internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 15 suffix represent in this model code?\u003c\/strong\u003e\u003cbr\u003eThe 15 suffix indicates the measurement configuration is set for XY dual vibration, allowing the monitor to process two orthogonal vibration signals simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with standard proximity probes?\u003c\/strong\u003e\u003cbr\u003eYes, this model is configured for use with standard Bently Nevada proximity probes and their associated Proximitor sensors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50840210833660,"sku":"3300\/16-15-01-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_066ee6cc-0b9d-46d8-9130-d3be5a9fa764.jpg?v=1785553752"},{"product_id":"bently-nevada-3300-15-02-02-00-00-00-00-dual-vibration-monitor-1","title":"Bently Nevada 3300\/15-02-02-01-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/15 Dual Vibration Monitor is a rack-mounted module within the legacy 3300 Series monitoring system. It is engineered to provide continuous, high-reliability monitoring of radial shaft vibration across two independent channels. By processing signals from proximity probes, the module detects mechanical anomalies such as shaft imbalance, misalignment, and bearing degradation in rotating machinery like turbines, compressors, and pumps.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel vibration monitoring for comprehensive radial shaft analysis.\u003c\/li\u003e\n\u003cli\u003eIntegrated signal processing for Proximitor sensors.\u003c\/li\u003e\n\u003cli\u003eContinuous comparison of vibration levels against user-defined Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED status indicators for OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA outputs for integration with external DCS or PLC systems.\u003c\/li\u003e\n\u003cli\u003eStandard relay outputs for automated machinery protection and shutdown logic.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is designed for critical asset protection in industrial environments, including power generation, oil and gas, and petrochemical processing. It is typically deployed in 3300 Series racks to monitor large rotating equipment where early fault detection is essential for preventing catastrophic failure.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/15-02-02-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Proximity Probe Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA proportional, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) precautions to protect sensitive internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring for proximity probes is shielded and properly grounded to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in the rack slot and the front-panel locking mechanisms are secured.\u003c\/li\u003e\n\u003cli\u003eConfigure alarm setpoints and scaling via the module interface to match the specific mechanical requirements of the monitored machine.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/15 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/15 is designed to monitor radial shaft vibration on rotating machinery, providing continuous signal processing and alarm relay actuation to protect equipment from mechanical damage.\u003c\/p\u003e\u003ch3\u003eCan this module be used with any sensor type?\u003c\/h3\u003e\u003cp\u003eThis specific model (suffix 01) is configured for use with Bently Nevada proximity probes (Proximitor sensors).\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators represent?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide visual confirmation of the module's health (OK), current alarm status (Alert\/Danger), and maintenance state (Bypass).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50846517068028,"sku":"3300\/15-02-02-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_0f30af3c-c42e-43b5-9fd7-8ecb60113037.jpg?v=1785557732"},{"product_id":"bently-nevada-991-01-xx-01-00-vibration-transmitter","title":"Bently Nevada 3300\/20-01-01-02-01-00 Dual Thrust Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/20 Dual Thrust Monitor is a specialized monitoring module designed for the 3300 series system. It provides continuous monitoring of axial shaft position (thrust) in rotating machinery, ensuring critical protection by comparing the measured position against user-programmed alarm setpoints. This monitor is engineered to process signals from proximity transducers to detect excessive axial movement, which is essential for preventing catastrophic equipment failure.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel monitoring capability for redundancy or multi-point axial measurement.\u003c\/li\u003e\n\u003cli\u003eCompatible with 7200 series proximity transducer systems.\u003c\/li\u003e\n\u003cli\u003eIntegrated 4-20 mA recorder output for external data logging and trending.\u003c\/li\u003e\n\u003cli\u003eConfigurable alarm setpoints for Danger and Alert conditions.\u003c\/li\u003e\n\u003cli\u003eDesigned for integration into the standard Bently Nevada 3300 rack system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e3300\/20-01-01-02-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScale Factor\u003c\/td\u003e\n\u003ctd\u003e7200 200 mV\/mil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull Scale Range\u003c\/td\u003e\n\u003ctd\u003e25-0-25 mils\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e0 to -10 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.7 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer Power Supply\u003c\/td\u003e\n\u003ctd\u003e-24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is properly grounded according to site electrical standards to prevent noise interference.\u003c\/li\u003e\n\u003cli\u003eAlways power down the rack before inserting or removing the monitor module to prevent electrical arcing or damage to the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for transducer inputs to minimize EMI\/RFI susceptibility.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the 3300 rack to ensure ambient temperatures remain within the 0 to +65 deg C operating range.\u003c\/li\u003e\n\u003cli\u003eVerify that the transducer power supply settings match the requirements of the installed proximity probes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/20 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/20 is designed to monitor the axial position of a machine shaft, providing critical protection by triggering alarms or trips if the shaft position exceeds safe operating limits.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other Bently Nevada systems?\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for the Bently Nevada 3300 series monitoring system. It is not directly interchangeable with 3500 series modules.\u003c\/p\u003e\u003ch3\u003eWhat does the 4-20 mA output provide?\u003c\/h3\u003e\u003cp\u003eThe 4-20 mA output provides a proportional signal representing the measured thrust position, which can be sent to a PLC, DCS, or external data acquisition system for remote monitoring.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50909853155580,"sku":"3300\/20-01-01-02-01-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_d8854450-da52-4c98-8fc1-41e438fa7226.jpg?v=1785632682"},{"product_id":"3300-16-11-01-01-00-00-00-bently-nevada-dual-vibration-monitor-1","title":"Bently Nevada 3300\/20-12-01-01-00-00 Dual Thrust Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/20 Dual Thrust Monitor is a rack-mounted module engineered for precise axial thrust position measurement in critical rotating machinery, including turbines and compressors. This specific model, 3300\/20-12-01-01-00-00, is configured for dual-channel thrust monitoring, providing continuous analysis of axial displacement against defined alarm setpoints. By detecting bearing wear or potential mechanical failure early, the module facilitates effective predictive maintenance strategies and minimizes unplanned downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel axial thrust monitoring for comprehensive machine protection.\u003c\/li\u003e\n\u003cli\u003eContinuous parameter comparison against user-defined Alert and Danger alarm setpoints.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for automated alarm actuation.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for quick status verification of OK, Bypass, Alert, and Danger states.\u003c\/li\u003e\n\u003cli\u003eConfigured for use with standard proximity probes and Proximitor sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAxial position monitoring for steam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eThrust bearing wear detection in centrifugal compressors.\u003c\/li\u003e\n\u003cli\u003eCritical asset protection in power generation and petrochemical facilities.\u003c\/li\u003e\n\u003cli\u003eIntegration into existing Bently Nevada 3300 monitoring racks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/20-12-01-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe signals via Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical, +\/- 1% max at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be seated firmly in the designated rack slot to ensure proper backplane connectivity.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that proximity probe gaps are calibrated according to the machine manufacturer's specifications.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure the ambient temperature remains within the 0 to 60 degC operating range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to protect internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 12 suffix denote in this model?\u003c\/h3\u003e\u003cp\u003eThe 12 suffix indicates the dual-channel thrust configuration, allowing the monitor to process two independent axial displacement inputs simultaneously.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing 3300 racks?\u003c\/h3\u003e\u003cp\u003eYes, this module is designed for the standard 3300 series rack architecture. Ensure your rack backplane configuration supports the 3300\/20 module type.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50909879337212,"sku":"3300\/20-12-01-01-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_51835a7a-1776-4dbb-af0a-46147581aa24.jpg?v=1785633930"},{"product_id":"3300-16-11-01-01-00-00-00-bently-nevada-dual-vibration-monitor-2","title":"Bently Nevada 3300\/25-04-04-04-01-02-01-01 Dual Accelerometer Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/25-04-04-04-01-02-01-01 is a Dual Accelerometer Monitor designed for machinery protection and diagnostics within the 3300 Series monitoring system. This module provides continuous, reliable monitoring of casing vibration using accelerometer inputs, delivering both dynamic and proportional outputs for critical alarm and trip functions. It is engineered for integration into turbines, compressors, and pumps where precise casing vibration detection is essential for operational reliability and safety.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Channel Monitoring:\u003c\/strong\u003e Supports two independent accelerometer inputs for redundant or multi-point measurement configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Processing:\u003c\/strong\u003e Converts raw accelerometer signals into proportional values for precise alarm and danger setpoint management.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Fully compatible with the 3300 system architecture for seamless rack-mounted installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Role:\u003c\/strong\u003e Facilitates early detection of mechanical faults through continuous casing vibration monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e Provides dynamic vibration signals and proportional 4–20 mA outputs for direct integration with DCS or PLC control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily utilized in industrial environments requiring high-reliability machinery protection, including power generation turbines, large centrifugal compressors, and critical pumping systems. It is designed to interface with existing 3300 rack configurations to provide real-time vibration analysis.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/25-04-04-04-01-02-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2 Accelerometer Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003e3300 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Seating:\u003c\/strong\u003e Ensure the module is fully seated in the 3300 rack slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Always use a grounded wrist strap when handling the module to prevent electrostatic discharge damage to internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Status:\u003c\/strong\u003e Ensure the system rack is powered down before inserting or removing the monitor module to prevent electrical arcing or configuration corruption.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cabling for accelerometer inputs to minimize EMI interference. Route signal cables away from high-voltage AC power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the rack is properly grounded according to site safety standards to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/25 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/25 is designed to monitor casing vibration on rotating machinery. It processes signals from accelerometers to provide alarm and trip functions, protecting equipment from potential mechanical failure.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other 3300 series components?\u003c\/h3\u003e\u003cp\u003eYes, this monitor is designed specifically for the Bently Nevada 3300 series rack architecture and is compatible with standard 3300 system components.\u003c\/p\u003e\u003ch3\u003eWhat type of output does this module provide?\u003c\/h3\u003e\u003cp\u003eIt provides both dynamic vibration signals for diagnostic analysis and proportional 4–20 mA outputs for integration into external DCS or PLC systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50909898670332,"sku":"3300\/25-04-04-04-01-02-01-01","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_f2cf294a-bf6c-41ea-a683-fd2622732ef3.jpg?v=1785634667"},{"product_id":"bently-nevada-3300-16-13-01-01-00-00-00-xy-gap-dual-vibration-monitor-3","title":"Bently Nevada 3300\/16-02-01-01-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/16 Dual Vibration Monitor is a rack-mounted module engineered for the continuous monitoring of radial shaft vibration in critical rotating machinery, such as turbines, compressors, and pumps. This specific model, 3300\/16-02-01-01-00-00-00, provides dual-channel vibration monitoring, allowing for the simultaneous tracking of two independent vibration signals. By continuously comparing input parameters against user-defined alarm setpoints, the monitor provides essential early warning of mechanical degradation, supporting effective predictive maintenance programs.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel vibration monitoring for comprehensive machine protection.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard proximity probe and Proximitor sensor inputs.\u003c\/li\u003e\n\u003cli\u003eIntegrated Alert and Danger alarm setpoints with relay output actuation.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for quick status verification of OK, Bypass, Alert, and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eStandardized 3300 series rack-mount form factor for seamless integration into existing monitoring systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eCentrifugal and axial compressor protection.\u003c\/li\u003e\n\u003cli\u003eLarge motor and generator bearing vibration analysis.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose rotating equipment requiring radial vibration monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-02-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.5 W per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eProximity probe signals via Proximitor sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical, +\/- 1% max at 25 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack backplane to ensure reliable connection of power and signal buses.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all transducer inputs to minimize electromagnetic interference (EMI) and signal noise.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the equipment cabinet to ensure the module operates within the 0 to 60 degC temperature range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD (Electrostatic Discharge) precautions to protect sensitive internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 02 measurement option signify?\u003c\/h3\u003e\u003cp\u003eThe 02 option indicates that the module is configured for dual-channel vibration monitoring, allowing it to process two independent input signals simultaneously.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing 3300 racks?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/16 is designed to be fully compatible with the standard Bently Nevada 3300 series rack architecture.\u003c\/p\u003e\u003ch3\u003eWhat is the primary function of the relay outputs?\u003c\/h3\u003e\u003cp\u003eThe relay outputs are used to trigger external alarms or trip logic systems when the monitored vibration levels exceed the pre-configured Alert or Danger setpoints.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50910542332156,"sku":"3300\/16-02-01-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a2432c65-aa19-492e-8b4d-694e91b33323.jpg?v=1785669882"},{"product_id":"bently-nevada-3300-55-01-01-02-02-00-00-03-00-dual-velocity-monitor","title":"Bently Nevada 3300\/55-01-04-18-18-00-00-05-00 Dual Velocity Monitor I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a rack-mounted module engineered for the 3300 Monitoring System. It is designed to measure casing vibration velocity by interfacing with Velomitor piezo-velocity sensors. The module provides two independent channels of continuous vibration monitoring, comparing input signals against user-defined Alert and Danger setpoints to ensure the protection of critical rotating machinery such as turbines, compressors, motors, and pumps.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel velocity monitoring for high-density rack configurations.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Velomitor piezo-velocity sensor inputs.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic with Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eDual relay outputs for automated machinery protection and shutdown sequences.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA output for integration with external PLC or DCS systems.\u003c\/li\u003e\n\u003cli\u003eStandardized 3300 series rack-mount form factor for seamless system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in industrial environments for the continuous monitoring of casing vibration on rotating equipment. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbines\u003c\/li\u003e\n\u003cli\u003eCentrifugal compressors and pumps\u003c\/li\u003e\n\u003cli\u003eLarge electric motors and generators\u003c\/li\u003e\n\u003cli\u003eFans and blowers in critical process loops\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/55-01-04-18-18-00-00-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eVelomitor piezo-velocity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration signals, 4-20 mA proportional, relay contacts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack system is powered down before inserting or removing the module to prevent electrical damage or system faults.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack backplane to ensure proper communication and power distribution.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all sensor inputs to minimize electromagnetic interference (EMI) and signal noise.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the 3300 rack chassis according to site-specific instrumentation grounding standards.\u003c\/li\u003e\n\u003cli\u003eVerify that the configuration jumpers and software setpoints match the specific sensor type and machine requirements before placing the system into service.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/55 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/55 is a dual-channel velocity monitor that processes signals from piezo-velocity sensors to provide continuous vibration monitoring and alarm relay actuation for rotating machinery protection.\u003c\/p\u003e\u003ch3\u003eDoes this module include intrinsic safety barriers?\u003c\/h3\u003e\u003cp\u003eNo, this specific order code (ending in -00 for the barrier option) does not include internal intrinsic safety barriers. Ensure your installation environment meets the requirements for non-intrinsically safe equipment or utilize external barriers if required.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50910550032636,"sku":"3300\/55-01-04-18-18-00-00-05-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a59277a7-7084-49ad-86e8-20c88b79f223.jpg?v=1785671015"},{"product_id":"330930-060-00-00-bently-nevada-3300-xl-standard-extension-cable","title":"Bently Nevada 3300\/35-05-02-01-00-00 6-Channel Temperature Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/35 Temperature Monitor is a rack-mounted module designed to measure multiple temperature points in turbines, compressors, and other critical rotating machinery. The 05 suffix option specifies a 6-channel configuration, supporting both RTD and thermocouple inputs. It continuously compares temperature readings against alarm setpoints, providing early warning of abnormal thermal conditions and enabling predictive maintenance.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSix independent input channels for comprehensive thermal monitoring.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of sensor types including RTDs (Pt100, Pt1000) and thermocouples (J, K, T types).\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic with Alert and Danger setpoints.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for system status: OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eStandard relay outputs for direct integration with plant safety and control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily used in industrial environments for monitoring bearing temperatures, stator windings, and equipment casings in large rotating machinery such as gas and steam turbines, centrifugal compressors, and large electric motors.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/35-05-02-01-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eRTD (Pt100, Pt1000), Thermocouple (J, K, T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the rack system to mitigate EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all sensor inputs to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that sensor wiring matches the configured input type (RTD vs. Thermocouple) before applying power.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure operating temperatures remain within the specified -35 degC to +65 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat sensor types are compatible with this module?\u003c\/h3\u003e\u003cp\u003eThis specific model supports RTDs (Pt100 and Pt1000) and standard J, K, and T type thermocouples.\u003c\/p\u003e\u003ch3\u003eDoes this module require external barriers?\u003c\/h3\u003e\u003cp\u003eThe 00 suffix in the barrier option position indicates that this unit is configured with standard input barriers; ensure your installation environment complies with hazardous area requirements if applicable.\u003c\/p\u003e\u003ch3\u003eHow are the alarm setpoints configured?\u003c\/h3\u003e\u003cp\u003eAlarm setpoints for Alert and Danger conditions are configured through the Bently Nevada 3300 system interface, allowing for independent thresholds per channel.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50912523092220,"sku":"3300\/35-05-02-01-00-00","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_492eb5c1-2e9e-4f2d-bc66-9a958b92db5b.jpg?v=1785748590"},{"product_id":"bently-nevada-3300-35-05-02-01-00-00-6-channel-temperature-monitor","title":"Bently Nevada 3300\/35-03-02-02-01-00 6-Channel Temperature Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/35-03-02-02-01-00 is a 6-channel Temperature Monitor designed for the 3300 Series rack system. This module provides continuous, high-reliability monitoring of multiple temperature points in critical rotating machinery, such as turbines, compressors, and large motors. By comparing sensor inputs against user-defined alarm setpoints, the module facilitates predictive maintenance and provides essential machinery protection by triggering relay outputs during abnormal temperature conditions.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSix independent monitoring channels for high-density temperature data acquisition.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard industrial RTDs (Pt100, Pt1000) and thermocouples (J, K, T types).\u003c\/li\u003e\n\u003cli\u003eProvides proportional 4 to 20 mA and 1 to 5 VDC outputs for integration with external control systems.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm conditions.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for quick status verification of OK, Bypass, Alert, and Danger states.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBearing temperature monitoring in rotating equipment.\u003c\/li\u003e\n\u003cli\u003eStator winding temperature sensing for large motors and generators.\u003c\/li\u003e\n\u003cli\u003eCasing temperature monitoring for industrial compressors and turbines.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose multi-point temperature data acquisition in process plants.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/35-03-02-02-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e6-Channel Temperature Monitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-35 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e6 Channels (RTD\/Thermocouple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 1-5 VDC, Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be seated firmly in the rack slot to ensure proper backplane communication and power distribution.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all sensor inputs to minimize EMI\/RFI interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the 3300 rack chassis to a common plant ground.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions; avoid touching the module's backplane connector pins.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat types of sensors are compatible with this module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/35-03-02-02-01-00 supports RTDs including Pt100 and Pt1000, as well as J, K, and T type thermocouples.\u003c\/p\u003e\u003ch3\u003eDoes this module provide alarm outputs?\u003c\/h3\u003e\u003cp\u003eYes, the module includes integrated relay outputs configured for Alert and Danger alarm conditions, allowing for direct interface with shutdown or alarm systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50912578044156,"sku":"3300\/35-03-02-02-01-00","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_9e9db11f-8276-49d4-9958-0769b7456b7f.jpg?v=1785749565"},{"product_id":"bently-nevada-3300-55-dual-velocity-monitor","title":"Bently Nevada 3300\/55 Dual Velocity Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a key component of the 3300 Monitoring System, designed to provide continuous, reliable vibration monitoring for industrial rotating machinery. This module accepts input from velocity seismoprobes to monitor casing vibration, ensuring equipment health and protection through precise signal processing and alarm capabilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel monitoring for independent or redundant vibration measurement.\u003c\/li\u003e\n\u003cli\u003eConfigurable scale factors including 500 mV\/in\/s, 145 mV\/in\/s, and 100 mV\/in\/s.\u003c\/li\u003e\n\u003cli\u003eIntegrated 4-20 mA recorder outputs for external data logging and trend analysis.\u003c\/li\u003e\n\u003cli\u003eWide frequency response range from 3 Hz to 10,000 Hz.\u003c\/li\u003e\n\u003cli\u003eRobust design for harsh industrial environments with high humidity tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis monitor is widely used in power generation, oil and gas, and petrochemical facilities to protect critical assets such as turbines, compressors, pumps, and fans. It is specifically engineered for casing vibration monitoring where velocity-based measurements are required to detect mechanical faults.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e3300\/55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e500 mV\/in\/s, 145 mV\/in\/s, or 100 mV\/in\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e3 Hz to 10,000 Hz (180-600,000 cpm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eWithin +\/- 0.33% of full-scale typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eWithin +\/- 1.6% of monitor full-scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +65 degC (+32 degF to +150 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (-40 degF to +185 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is properly grounded to a clean earth point to minimize electrical noise.\u003c\/li\u003e\n\u003cli\u003eAlways power down the rack before inserting or removing the 3300\/55 module to prevent damage to the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all signal inputs to maintain signal integrity and reduce EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the probe sensitivity settings on the module match the installed seismoprobe specifications.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate airflow around the 3300 rack to ensure the module operates within the specified temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the 3300\/55?\u003c\/strong\u003e\u003cbr\u003eThe 3300\/55 is a dual-channel velocity monitor used to measure and track casing vibration on rotating machinery, providing necessary alarm outputs for machinery protection.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module be used with different seismoprobes?\u003c\/strong\u003e\u003cbr\u003eYes, the module supports multiple sensitivity settings (500, 145, and 100 mV\/in\/s), allowing it to be configured for various compatible velocity sensors.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50915216982268,"sku":"3300\/55","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_025fd0b1-814b-4208-9726-03e5b345a9d6.jpg?v=1785818947"},{"product_id":"bently-nevada-3300-20-01-01-02-01-00-dual-thrust-monitor-2","title":"Bently Nevada 3300\/14-01-22-00 Relay Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/14-01-22-00 is a rack-mounted Relay Module designed for the Bently Nevada 3300 Monitoring System. This module serves as a critical interface between the system's internal monitoring functions—such as vibration, thrust, eccentricity, and expansion—and external machinery protection or control systems. It provides reliable relay outputs triggered by Alert and Danger conditions, facilitating automated shutdown or alarm annunciation logic.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvides dedicated relay outputs for Alert and Danger alarm states.\u003c\/li\u003e\n\u003cli\u003eForm-C (SPDT) contact configuration for versatile integration.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for real-time relay status monitoring.\u003c\/li\u003e\n\u003cli\u003eStandard 3300 rack-mount form factor for seamless system integration.\u003c\/li\u003e\n\u003cli\u003eSupports robust machinery protection and emergency shutdown sequences.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically deployed in industrial environments requiring automated protection for rotating machinery. It is commonly used in power generation, oil and gas, and petrochemical facilities to interface 3300 monitoring racks with PLC or DCS shutdown logic.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/14-01-22-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRelay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eDual Form-C (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A at 24 VDC or 120 VAC (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage or unintended relay activation.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot to ensure proper backplane communication.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for relay output connections to minimize EMI\/RFI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure that the contact load ratings (5 A at 24 VDC\/120 VAC) are strictly observed to prevent relay contact welding or failure.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the 3300 rack to ensure operation within the specified 0 to 60 degC temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 3300\/14-01-22-00 model code indicate?\u003c\/h3\u003e\u003cp\u003eThe code represents the base 3300\/14 relay module with standard agency approval (01), a specific relay configuration (22), and standard barrier options (00).\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other Bently Nevada systems?\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for the Bently Nevada 3300 series rack system and is not directly compatible with 3500 or other series racks.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50915411755260,"sku":"3300\/14-01-22-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ce988ffe-87c2-477f-8909-74dba53ab7ca.jpg?v=1785826701"},{"product_id":"3300-20-11-01-01-00-02-bently-nevada-dual-thrust-monito","title":"Bently Nevada 3300\/15-02-02-00-00-00-00 Dual Vibration Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/15 Dual Vibration Monitor is a rack-mounted module within the 3300 Series system, specifically engineered to measure and protect rotating machinery by continuously monitoring shaft vibration. This module provides two independent vibration channels, delivering both dynamic and proportional outputs for critical alarm and trip functions. It is widely deployed in industrial environments such as turbines, compressors, and pumps where precise, real-time vibration detection is essential for operational reliability and safety.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel vibration monitoring for independent signal processing.\u003c\/li\u003e\n\u003cli\u003eDynamic and proportional outputs for comprehensive machinery analysis.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm setpoints.\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration into the 3300 Series rack architecture.\u003c\/li\u003e\n\u003cli\u003eStandard configuration for proximity probe transducer inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating compressor protection.\u003c\/li\u003e\n\u003cli\u003eLarge pump and motor vibration analysis.\u003c\/li\u003e\n\u003cli\u003eCritical rotating equipment safety and trip systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/15-02-02-00-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Proximity probe channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic signals, 4-20 mA proportional, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 Series rack is properly grounded before installing the module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD (Electrostatic Discharge) protection practices.\u003c\/li\u003e\n\u003cli\u003eVerify that the rack power is disconnected before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure all signal wiring is routed away from high-voltage or high-EMI sources to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eConfirm that the transducer input configuration matches the installed proximity probes before system commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/15 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/15 is a dual-channel vibration monitor designed to process signals from proximity probes to provide continuous monitoring and alarm\/trip protection for rotating machinery.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing 3300 Series racks?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/15 is designed specifically for the 3300 Series rack system and is intended to be installed in standard rack slots.\u003c\/p\u003e\u003ch3\u003eDoes this module require external barriers?\u003c\/h3\u003e\u003cp\u003eThe specific order code 3300\/15-02-02-00-00-00-00 indicates a standard input barrier configuration without intrinsic safety barriers. Consult your site safety requirements if intrinsic safety is required for your installation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50915443933436,"sku":"3300\/15-02-02-00-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_7ce5e711-6db6-4d65-820f-855bd56a1411.jpg?v=1785827875"},{"product_id":"bently-nevada-3300-55-01-04-12-12-00-00-05-01-dual-velocity-monitor","title":"Bently Nevada 3300\/55-01-05-12-12-00-00-05-00 Dual Velocity Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a rack-mounted module within the 3300 Series monitoring system. It is specifically engineered to measure casing vibration velocity by interfacing with Velomitor piezo-velocity sensors. The 3300\/55-01-05-12-12-00-00-05-00 configuration provides two independent channels of vibration monitoring, featuring enhanced input scaling and relay logic designed for the protection of critical turbomachinery.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel independent velocity measurement.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Velomitor piezo-velocity sensors.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA outputs for integration with external control systems (DCS\/PLC).\u003c\/li\u003e\n\u003cli\u003eConfigurable relay outputs for Alert and Danger alarm conditions.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED status indicators for OK, Bypass, Alert, and Danger states.\u003c\/li\u003e\n\u003cli\u003eEnhanced input scaling and alarm logic for precise machinery protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely used in industrial environments for continuous monitoring of critical rotating equipment, including steam turbines, gas turbines, centrifugal compressors, and large pumps. It provides the necessary signal processing to detect casing vibration anomalies and trigger protective shutdowns or operator alerts.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/55-01-05-12-12-00-00-05-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Velomitor piezo-velocity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA proportional, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is properly seated in the rack slot and that the front-panel screws are tightened to ensure a secure ground connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for sensor inputs to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the cabinet to ensure the ambient temperature remains within the 0 degC to +60 degC range.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) handling procedures when touching internal components or connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/55 module?\u003c\/h3\u003e\u003cp\u003eThe 3300\/55 is designed to monitor casing vibration velocity. It processes signals from two Velomitor sensors and compares them against user-defined Alert and Danger setpoints to protect rotating machinery.\u003c\/p\u003e\u003ch3\u003eCan this module be used in hazardous areas?\u003c\/h3\u003e\u003cp\u003eThis specific order code (3300\/55-01-05-12-12-00-00-05-00) includes standard input barrier configuration (no intrinsic safety). Please verify your site's hazardous area requirements before installation.\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators on the front panel represent?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide immediate visual feedback for the module's health and the status of the monitored machinery, specifically indicating OK (sensor\/module health), Bypass (maintenance mode), Alert, and Danger alarm conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50915528245500,"sku":"3300\/55-01-05-12-12-00-00-05-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_f435e8a1-ce3f-4fd2-9136-4e28b26af5a2.jpg?v=1785831098"},{"product_id":"bently-nevada-3300-55-01-04-18-18-00-00-05-00-dual-velocity-monitor-i-o-module","title":"Bently Nevada 3300\/55-01-04-02-02-00-00-04-00 Dual Velocity Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a critical component of the 3300 Series machinery protection system. This module is engineered to monitor casing vibration velocity by interfacing with Velomitor piezo-velocity sensors. It provides two independent channels of continuous vibration monitoring, comparing real-time input values against user-defined Alert and Danger setpoints to ensure the integrity of rotating equipment such as turbines, compressors, motors, and pumps.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel velocity monitoring for redundant or multi-point machinery protection.\u003c\/li\u003e\n\u003cli\u003eDirect interface compatibility with Velomitor piezo-velocity sensors.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic with dedicated Alert and Danger relay outputs.\u003c\/li\u003e\n\u003cli\u003eProportional 4–20 mA output for integration with external PLC or DCS control systems.\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration into existing 3300 Series rack environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis monitor is widely utilized in heavy industrial environments for critical asset protection, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eSteam and gas turbine vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eCentrifugal and reciprocating compressor casing vibration analysis.\u003c\/li\u003e\n\u003cli\u003eLarge motor and pump bearing housing velocity measurement.\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant rotating equipment requiring continuous vibration surveillance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/55-01-04-02-02-00-00-04-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eVelomitor piezo-velocity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration signals, 4–20 mA proportional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot and that the front panel screws are tightened to ensure proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for sensor inputs to minimize electromagnetic interference (EMI) in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eEnsure that input wiring is routed away from high-voltage AC power lines to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD handling procedures when touching the module circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/55 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/55 is designed to measure vibration velocity on machine casings using piezo-velocity sensors and provide alarm relay outputs for machinery protection.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other 3300 series components?\u003c\/h3\u003e\u003cp\u003eYes, this monitor is designed specifically for the Bently Nevada 3300 Series rack system and is compatible with standard 3300 series power supplies and I\/O modules.\u003c\/p\u003e\u003ch3\u003eDoes this unit require external barriers?\u003c\/h3\u003e\u003cp\u003eThis specific model (suffix 00 for barriers) is configured for standard input and does not include intrinsic safety barriers.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50918819004668,"sku":"3300\/55-01-04-02-02-00-00-04-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3cd4f9d9-b480-4188-9949-2e0ce4aae80a.jpg?v=1785894031"},{"product_id":"bently-nevada-3300-16-13-01-01-00-00-00-xy-gap-dual-vibration-monitor","title":"Bently Nevada 3300\/16-11-01-01-00-00-00 Dual Vibration Monitor","description":"\u003cp\u003eThe Bently Nevada 3300\/16 Dual Vibration Monitor is a rack-mounted module engineered for continuous radial shaft vibration measurement in critical rotating machinery, including turbines, compressors, and pumps. This dual-channel monitor provides essential protection by comparing real-time vibration data against pre-configured Alert and Danger setpoints, facilitating both equipment safety and predictive maintenance.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel radial vibration monitoring for comprehensive shaft analysis.\u003c\/li\u003e\n\u003cli\u003eConfigured for proximity probe inputs via Proximitor sensors.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic with relay actuation for Alert and Danger conditions.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for system status: OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eStandardized 3300 rack system compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is designed for use in industrial environments where monitoring shaft displacement is critical to prevent mechanical failure. Common applications include large steam and gas turbines, centrifugal compressors, and high-speed pumps where vibration trends are key indicators of machine health.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/16-11-01-01-00-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e~1.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e200 mV\/mil (8 V\/mm) or 100 mV\/mil (4 V\/mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.33% typical, ±1% max at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA, +1 to +5 VDC, 0 to -10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the rack system to mitigate EMI and ensure signal integrity.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for proximity probe inputs to minimize noise interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot and that the front-panel connectors are securely fastened.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation within the cabinet to ensure the module operates within the specified 0 to 60 deg C temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 11-01-01-00-00-00 suffix indicate?\u003c\/h3\u003e\u003cp\u003eThese codes define the specific configuration of your module, including the XY radial vibration setup, standard agency approval, proximity probe input compatibility, and default relay\/barrier settings.\u003c\/p\u003e\u003ch3\u003eCan this module be used for non-radial vibration measurements?\u003c\/h3\u003e\u003cp\u003eThe 3300\/16 is specifically optimized for radial shaft vibration. For other measurement types, please consult the Bently Nevada 3300 series documentation for the appropriate module model.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50926971683068,"sku":"3300\/16-11-01-01-00-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_9269f1ea-7335-4430-b9f6-3a628aa51bb7.jpg?v=1786081153"},{"product_id":"bently-nevada-3300-40-13-01-01-00-00-eccentricity-monitor-module","title":"Bently Nevada 3300\/50-02-02-00-00 Tachometer Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/50 Tachometer Module is a rack-mounted monitoring unit engineered to measure shaft rotational speed and provide critical overspeed protection for rotating machinery such as turbines and compressors. This module processes signals from proximity probes or magnetic pickups, delivering conditioned outputs for integration into plant-wide monitoring and control systems.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel configuration supporting redundant speed inputs.\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring of shaft rotational speed and phase reference.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm logic for Alert and Danger setpoints with relay actuation.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for system status, including OK, Bypass, Alert, and Danger.\u003c\/li\u003e\n\u003cli\u003eConfigurable signal conditioning for various probe sensitivities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/50-02-02-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Compatibility\u003c\/td\u003e\n\u003ctd\u003eProximity probes, magnetic pickups\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.33% typical (+\/- 1% max at 25 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output\u003c\/td\u003e\n\u003ctd\u003e+4 to +20 mA (+\/- 0.7% accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003ctd\u003e+1 to +5 VDC \/ 0 to -10 VDC (+\/- 1.1% accuracy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be seated firmly in the designated rack slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all input signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the rack and associated transducers to ensure signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the module configuration matches the specific transducer type and speed range required for the application.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/50 module?\u003c\/h3\u003e\u003cp\u003eIt is designed to measure shaft rotational speed and provide reliable overspeed protection for critical rotating equipment by monitoring proximity probe or magnetic pickup inputs.\u003c\/p\u003e\u003ch3\u003eCan this module be used for phase reference?\u003c\/h3\u003e\u003cp\u003eYes, the module is capable of measuring both shaft rotational speed and phase reference signals.\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators on the front panel represent?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide visual status for the OK (system health), Bypass (maintenance mode), Alert (warning threshold), and Danger (shutdown threshold) conditions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50927057928444,"sku":"3300\/50-02-02-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_5d36afb9-4e09-4bac-8890-1c8d779d4048.jpg?v=1786081852"},{"product_id":"bently-nevada-3300-55-01-01-02-02-00-00-03-00-dual-velocity-monitor-1","title":"Bently Nevada 3300\/55-03-01-15-15-00-00-01-00 Dual Velocity Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/55 Dual Velocity Monitor is a critical component of the 3300 Series machinery protection system. It is engineered to provide continuous monitoring of casing vibration velocity by interfacing with Velomitor piezo-velocity sensors. This module features two independent channels that compare real-time vibration data against user-defined alarm setpoints, ensuring reliable protection for rotating equipment such as turbines, compressors, motors, and pumps.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-channel velocity monitoring for independent vibration analysis.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard Velomitor piezo-velocity sensors.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm and danger relay outputs for automated machinery trip functions.\u003c\/li\u003e\n\u003cli\u003eProvides proportional 4-20 mA outputs for integration with external control and data acquisition systems.\u003c\/li\u003e\n\u003cli\u003eDesigned for seamless integration into the 3300 rack-based monitoring architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis monitor is primarily used in industrial environments for the protection of critical rotating machinery. It is suitable for monitoring casing vibration in high-speed turbines, centrifugal compressors, large industrial motors, and pumps where velocity-based vibration monitoring is required to detect mechanical degradation or imbalance.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/55-03-01-15-15-00-00-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eVelomitor piezo-velocity sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signals\u003c\/td\u003e\n\u003ctd\u003eDynamic vibration, 4-20 mA proportional, voltage scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the rack slot and that the front panel connectors are securely fastened.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all sensor inputs to minimize electromagnetic interference (EMI) and signal noise.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the 3300 rack system according to the site-specific installation manual to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to sensitive internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/55 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/55 is designed to monitor casing vibration velocity using piezo-velocity sensors and provide alarm\/trip relay logic to protect rotating machinery from damage.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other sensor types?\u003c\/h3\u003e\u003cp\u003eThis specific configuration (15-15) is optimized for Velomitor piezo-velocity sensors. Refer to the Bently Nevada 3300 system documentation for compatibility with other sensor technologies.\u003c\/p\u003e\u003ch3\u003eDoes this module require external barriers?\u003c\/h3\u003e\u003cp\u003eThe suffix code 00 in the barrier option indicates that this unit is configured for standard input without intrinsic safety barriers.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50940070723836,"sku":"Dual Velocity Monitor","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a1ffd71c-9a92-4547-b1b8-d45fc5ce680c.jpg?v=1786147271"},{"product_id":"bently-nevada-3300-12-01-20-01-power-supply-module","title":"Bently Nevada 3300\/12-02-20-00 Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/12 Power Supply Module is a rack-mounted unit designed to provide regulated DC power to all monitoring modules within the 3300 Series system. This module ensures the stable operation of critical machinery protection equipment, including vibration, thrust, eccentricity, expansion, tachometer, and temperature monitors, by delivering clean and reliable power distribution across the rack.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvides regulated DC power to all installed 3300 Series monitoring modules.\u003c\/li\u003e\n\u003cli\u003eIncludes rack-wide OK status monitoring to ensure system health.\u003c\/li\u003e\n\u003cli\u003eSupports high-voltage AC input (220\/240 VAC) for industrial power environments.\u003c\/li\u003e\n\u003cli\u003eStandardized rack-mount profile for seamless integration into existing 3300 Series racks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/12-02-20-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e220\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Capacity\u003c\/td\u003e\n\u003ctd\u003eApprox. 150 W total rack capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003eRegulated DC power and OK relay status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the power supply module.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated rack slot, ensuring proper alignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the integrated front-panel locking mechanism to ensure a reliable electrical connection.\u003c\/li\u003e\n\u003cli\u003eVerify that the input voltage matches the 220\/240 VAC configuration specified by the model suffix.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure operating temperatures remain within the 0 to 60 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat does the 3300\/12-02-20-00 model code indicate?\u003c\/h3\u003e\u003cp\u003eThe 3300\/12 is the base power supply module for the 3300 rack. The '02' suffix indicates agency approval, '20' specifies the 220\/240 VAC input voltage configuration, and '00' denotes the standard input\/output barrier configuration.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with all 3300 series monitors?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/12 is designed to provide regulated DC power to all standard 3300 Series monitoring modules, including those for vibration, thrust, and temperature monitoring.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50940072427772,"sku":"3300\/12-02-20-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_88279579-8ca2-48ce-9ca5-8313f6c22319.jpg?v=1786147765"},{"product_id":"bently-nevada-3300-25-04-04-04-01-02-01-01-dual-accelerometer-monitor","title":"Bently Nevada 3300\/25-03-06-06-01-00-02-00 Dual Accelerometer Monitor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/25 Dual Accelerometer Monitor is a rack-mounted module within the 3300 Series monitoring system. It is engineered to provide continuous, high-reliability measurement of casing vibration acceleration using two independent accelerometer inputs. This specific configuration (3300\/25-03-06-06-01-00-02-00) is optimized for critical turbomachinery applications, including compressors and pumps, where high-frequency vibration detection is essential for predictive maintenance and machinery protection.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual independent accelerometer input channels for comprehensive casing vibration monitoring.\u003c\/li\u003e\n\u003cli\u003eProportional 4-20 mA outputs for integration with external control systems or data acquisition units.\u003c\/li\u003e\n\u003cli\u003eIntegrated relay outputs for Alert and Danger alarm conditions, facilitating automated machine shutdown or operator notification.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators providing real-time status for OK, Bypass, Alert, and Danger states.\u003c\/li\u003e\n\u003cli\u003eExtended full-scale range configuration for high-frequency vibration sensitivity.\u003c\/li\u003e\n\u003cli\u003eStandard input barrier configuration for signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 3300\/25 monitor is specifically designed for use in industrial environments requiring precise casing vibration analysis. Typical applications include:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCentrifugal and reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eIndustrial pumps and fans.\u003c\/li\u003e\n\u003cli\u003eSteam and gas turbines.\u003c\/li\u003e\n\u003cli\u003eGearboxes and high-speed rotating equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/25-03-06-06-01-00-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e2 x Accelerometer channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eDynamic signals, 4-20 mA, Relay (Alert\/Danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 series rack is properly grounded to a clean instrument earth to prevent ground loops and EMI interference.\u003c\/li\u003e\n\u003cli\u003eThe module should be inserted into the rack only after ensuring the power supply is stable and within specified limits.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all transducer inputs to maintain signal integrity in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to ensure operating temperatures remain within the specified -30 degC to +65 degC range.\u003c\/li\u003e\n\u003cli\u003eAlways perform system configuration and setpoint adjustments according to the specific machinery requirements and Bently Nevada technical documentation.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent ESD damage to internal components; use appropriate grounding straps during installation or maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/25 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/25 is a dual-channel monitor designed to process signals from accelerometers to measure casing vibration, providing alarm and shutdown capabilities for rotating machinery.\u003c\/p\u003e\u003ch3\u003eCan this module be used for high-frequency monitoring?\u003c\/h3\u003e\u003cp\u003eYes, this specific order code includes an extended full-scale range option, making it suitable for applications where high-frequency vibration detection is necessary.\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators on the front panel signify?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide immediate visual feedback on the health of the transducer (OK), the alarm status (Alert\/Danger), and whether the channel is currently in a maintenance or test mode (Bypass).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50940080029948,"sku":"3300\/25-03-06-06-01-00-02-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c57d6661-9383-4a1d-b749-422da57849aa.jpg?v=1786149687"},{"product_id":"bently-nevada-3300-16-13-01-01-00-00-00-xy-gap-dual-vibration-monitor-1","title":"Bently Nevada 3300\/05-22-00-00 Rack System","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/05 Rack System serves as the foundational mechanical housing and backplane for the 3300 series monitoring system. Engineered for industrial reliability, this rack provides the necessary structural support, electrical backplane connectivity, and slot capacity required to integrate various vibration, thrust, and I\/O monitoring modules. It is essential for protecting critical rotating machinery, including turbines, compressors, and pumps, by ensuring consistent module alignment and stable electrical communication across the monitoring architecture.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRobust mechanical housing designed for industrial protection environments.\u003c\/li\u003e\n\u003cli\u003eIntegrated backplane for reliable power distribution and signal communication between installed modules.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of 3300 series monitoring and I\/O cards.\u003c\/li\u003e\n\u003cli\u003eDesigned for standard panel mounting configurations.\u003c\/li\u003e\n\u003cli\u003eEnsures mechanical stability and electrical continuity for high-availability monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOrdering Information\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Code\u003c\/td\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3300\/05\u003c\/td\u003e\n\u003ctd\u003eBase Rack System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003eRack Size Configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard Mounting Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e00\u003c\/td\u003e\n\u003ctd\u003eStandard Agency Approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/05-22-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eRack System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Compatibility\u003c\/td\u003e\n\u003ctd\u003eStandard 3300 series power supplies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the rack is mounted in a clean, dry, and vibration-dampened environment.\u003c\/li\u003e\n\u003cli\u003eVerify that the mounting surface is rigid and capable of supporting the weight of the fully populated rack.\u003c\/li\u003e\n\u003cli\u003eUse proper grounding techniques to connect the rack to the system common to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003ePower down the system before inserting or removing any monitoring modules to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate airflow around the rack to maintain operating temperatures within the specified 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) handling procedures when installing or servicing modules within the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/05 rack?\u003c\/h3\u003e\u003cp\u003eThe 3300\/05 rack acts as the central chassis for the Bently Nevada 3300 monitoring system, providing the physical slots, power distribution, and data backplane required for the operation of vibration and thrust monitoring modules.\u003c\/p\u003e\u003ch3\u003eIs this rack compatible with all 3300 series modules?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/05 is designed to house standard 3300 series monitoring and I\/O modules, provided the specific rack size and power configuration requirements are met.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50965547385084,"sku":"3300\/05-22-00-00","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_36921342-3150-44d0-8d9a-68cc11c714df.jpg?v=1786411037"},{"product_id":"bently-nevada-3300-40-13-01-01-00-00-eccentricity-monitor-module-1","title":"Bently Nevada 3300\/03-02-01 System Monitor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 3300\/03 System Monitor is a rack-mounted supervisory module engineered to oversee the operational health and status of all monitoring modules within a 3300 series rack system. It serves as the central hub for diagnostics, alarm coordination, and communication, ensuring the integrity of machinery protection systems for critical assets such as turbines and compressors.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCentralized supervision of all monitoring modules installed within the 3300 rack.\u003c\/li\u003e\n\u003cli\u003eCoordinates OK, Bypass, Alert, and Danger relay logic for system-wide integrity.\u003c\/li\u003e\n\u003cli\u003eContinuous monitoring of rack power supply voltages and internal communication bus status.\u003c\/li\u003e\n\u003cli\u003eProvides interface capabilities for external control systems to receive alarm and status signaling.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for real-time rack and module health diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is essential for critical rotating machinery protection, including steam and gas turbines, centrifugal compressors, and large-scale industrial pumps where centralized rack management is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3300\/03-02-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3300 rack is powered down before inserting or removing the System Monitor module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated rack slot, ensuring the backplane connector is properly aligned and seated.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is securely fastened using the front panel captive screws to maintain proper grounding and vibration resistance.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to protect internal circuitry from electrostatic discharge.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the rack to maintain the operating temperature within the 0 to 60 degC range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 3300\/03 monitor?\u003c\/h3\u003e\u003cp\u003eThe 3300\/03 acts as the master supervisory module for the 3300 rack, managing communication, alarm relay coordination, and power supply monitoring for all other modules in the rack.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other 3300 series components?\u003c\/h3\u003e\u003cp\u003eYes, the 3300\/03 is specifically designed for integration within the Bently Nevada 3300 series rack architecture.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50965549875452,"sku":"3300\/03-02-01","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c31ed9d3-f770-42a3-bffb-3347c8899c55.jpg?v=1786411821"}],"url":"https:\/\/www.electronicplc.com\/collections\/bently-nevada-3300-series.oembed?page=3","provider":"Electronic PLC","version":"1.0","type":"link"}