{"title":"GE Fanuc","description":"\u003cp\u003e\u003cspan\u003eGE’s automation legacy spans decades of evolution in power generation and heavy manufacturing. This category serves as a technical resource for maintaining both modern and legacy GE infrastructures. We provide a wide range of hardware, from classic GE Fanuc PLCs to the high-speed processing power of the PACSystems RX3i\/RX7i platforms. Our inventory is structured to support engineers and plant managers in the energy, water treatment, and infrastructure sectors who require reliable, mission-critical spares. Whether you are maintaining a turbine control system or a distributed I\/O network, our GE components ensure your facility remains operational and compliant with original engineering standards.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"ge-fanuc-ic698cpe010-central-processing-unit","title":"GE Fanuc IC698CPE010 Central Processing Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC698CPE010 (Part Number IC698CPE010) is a high-performance VME-based Central Processing Unit designed for the PACSystems RX7i platform. Integrated with a 300MHz Celeron microprocessor, this CPU provides the robust computational power required for complex, high-speed industrial applications. The IC698CPE010 excels in data-intensive environments, offering significant memory capacity and built-in Ethernet connectivity to support modern industrial internet (IIoT) requirements, including web-based monitoring and FTP services.\u003c\/p\u003e\n\u003ch3\u003eHardware and Performance Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300MHz Intel Celeron Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Program Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 Mbytes battery-backed RAM; 10 Mbytes non-volatile Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Execution Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.195ms per 1,000 Boolean contacts\/coils (Typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.2 Amps nominal from the 5V bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReal-Time Clock Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaximum drift of 9 seconds per day\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual 10\/100 Mbps Ethernet (RJ45 10 BaseT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Services\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports up to 16 concurrent Web Server and FTP connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdvanced Networking and Storage\u003c\/h3\u003e\n\u003cp\u003eThe IC698CPE010 is engineered for the VME64 standard, ensuring high-speed backplane communication and compatibility with a wide range of specialized VME modules. Its dual-storage architecture—utilizing both battery-backed RAM for active execution and non-volatile Flash for permanent program retention—ensures system integrity during power cycles. Furthermore, the integrated Ethernet port facilitates seamless integration into plant-wide networks, allowing engineers to perform remote diagnostics and data monitoring through standard web browsers without additional middleware.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eHow does the fan tray affect the operation of the IC698CPE010?\u003c\/h4\u003e\n\u003cp\u003eThe addition of a fan tray increases the maximum allowable operating temperature from 50°C to 60°C, providing a necessary thermal safety margin in densely packed or poorly ventilated control cabinets.\u003c\/p\u003e\n\u003ch4\u003eWhat happens to my program if the battery fails?\u003c\/h4\u003e\n\u003cp\u003eWhile the RAM requires the battery for retention during power-off states, the IC698CPE010 features 10MB of non-volatile Flash memory. Users should configure the system to back up critical logic to Flash to prevent data loss in the event of a total battery discharge.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746716463356,"sku":"IC698CPE010","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC698CPE0102.jpg?v=1773816257"},{"product_id":"ic697mdl653-ge-fanuc-discrete-input-module","title":"IC697MDL653 GE Fanuc Discrete Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC697MDL653 (Part Number IC697MDL653) is a high-density discrete logic input module engineered for the GE Fanuc Series 90-70 PLC platform. This module features 32 input points organized into four isolated groups of eight, providing enhanced electrical protection and wiring flexibility for complex industrial circuits. Operating on a nominal 24 VDC supply, the IC697MDL653 supports both sinking (positive) and sourcing (negative) logic configurations, making it highly adaptable to various field device standards.\u003c\/p\u003e\n\u003ch3\u003eHardware and Performance Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 (4 isolated groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePositive and Negative (Sinking\/Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterface Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2-wire and 3-wire electronic proximity switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware-configurable (no jumpers or DIP switches required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Filtering\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUser-selectable filter times for noise suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterrupt Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports a single input configured as a system interrupt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 Green LEDs on the module faceplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Series 90-70 VME architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePushbuttons, limit switches, and selector switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAdvanced Functional Design\u003c\/h3\u003e\n\u003cp\u003eA key advantage of the IC697MDL653 is its jumper-free configuration, which allows users to define input\/output references and filtering parameters directly through the programming software. This reduces physical setup errors and simplifies module replacement. The inclusion of isolated groups ensures that faults in one section of the field wiring do not compromise the entire module's integrity. Furthermore, its ability to process high-speed signals via an interrupt-capable point allows for precise monitoring of time-critical machine events.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eDoes this module require an external power supply for the field side?\u003c\/h4\u003e\n\u003cp\u003eYes, the IC697MDL653 requires a user-supplied 24 VDC power source to excite the field devices and complete the input loops.\u003c\/p\u003e\n\u003ch4\u003eCan I mix positive and negative logic on the same module?\u003c\/h4\u003e\n\u003cp\u003eLogic types are typically consistent across the module; however, because the points are divided into four isolated groups, different groups can theoretically handle different wiring configurations if the common terminals are isolated.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746716496124,"sku":"IC697MDL653","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC697MDL6532.jpg?v=1773816257"},{"product_id":"plc-expansion-backplane-ic694chs392-ge-fanuc","title":"PLC Expansion Backplane IC694CHS392 GE Fanuc","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC694CHS392 (Part Number IC694CHS392A) is a standard serial expansion I\/O backplane designed for the PACSystems RX3i platform. This 10-slot chassis allows for the seamless expansion of input and output modules beyond the local CPU rack. Engineered for high-speed serial communication, the IC694CHS392 supports complex distributed I\/O architectures, enabling reliable data throughput across industrial control networks. It requires a dedicated serial power supply (such as the IC694PWR331, IC694PWR330, or IC694PWR321) to be installed in the leftmost slot to provide logic power to the expansion bus.\u003c\/p\u003e\n\u003ch3\u003eHardware and Expansion Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Serial Expansion I\/O Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Available Slots\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 (dedicated for I\/O modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOccupies the leftmost dedicated slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\/Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 mA @ 5 VDC (internal logic consumption)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports expansion cables up to 15 meters (50 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated DIP switches for rack address selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.0 cm x 44.3 cm x 14.2 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i serial expansion modules and cables\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation and Configuration Logic\u003c\/h3\u003e\n\u003cp\u003eBefore deploying the IC694CHS392, operators must configure the hardware DIP switches located on the backplane. These switches define the expansion rack ID, ensuring the CPU correctly addresses the modules residing on this specific segment of the serial bus. The right end of the chassis features a high-density connector for optional expansion cables, allowing daisy-chaining of multiple racks up to the 15-meter architectural limit. This backplane is specifically designed for RX3i serial modules and does not support PCI-based RX3i main rack modules.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhich power supplies are compatible with the IC694CHS392?\u003c\/h4\u003e\n\u003cp\u003eThe backplane is compatible with the IC694PWR331 (24VDC), IC694PWR330 (120\/240VAC), and IC694PWR321 (120\/240VAC\/125VDC) serial power supply modules.\u003c\/p\u003e\n\u003ch4\u003eCan I mix PCI and Serial modules in this backplane?\u003c\/h4\u003e\n\u003cp\u003eNo, the IC694CHS392 is a \"Serial Only\" backplane. It is designed to host IC694 series discrete and analog modules that utilize the serial bus protocol.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746716528892,"sku":"IC694CHS392A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC694CHS392A.jpg?v=1773816256"},{"product_id":"ge-fanuc-ic693cpu350-plc-central-processing-unit","title":"GE Fanuc IC693CPU350 PLC Central Processing Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC693CPU350 (Part Number IC693CPU350) is a high-performance, single-slot Central Processing Unit designed for the GE Fanuc Series 90-30 PLC family. Powered by an 80386EX processor operating at 25 MHz, this module delivers rapid execution speeds for complex logic and data handling. It is engineered to manage up to 8 total baseplates (including the local CPU baseplate and up to 7 expansion or remote racks), making it a versatile choice for medium-to-large scale industrial automation architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware and Performance Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80386EX, 25 MHz clock speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Memory Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48K Bytes for application logic and register data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e670 mA at +5 VDC (from the baseplate power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,048 Input points (%I) and 2,048 Output points (%Q)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal Logic Bits\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256 Temporary Coils (%T)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTimers and Counters\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupport for over 2,000 instances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRegister Operations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull support for Shift Registers and complex math functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Scaling\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports 1 CPU baseplate + 7 expansion\/remote baseplates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIntegration and Functional Capabilities\u003c\/h3\u003e\n\u003cp\u003eAs a single-slot module, the IC693CPU350 maximizes rack space within the Series 90-30 system. It provides consistent performance for time-critical applications through its dedicated 80386EX chip, ensuring reliable scan times even with a full 48K program load. The unit is fully compatible with existing Series 90-30 I\/O modules and power supplies, allowing for straightforward upgrades from lower-tier CPUs without requiring significant hardware re-engineering.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhat is the maximum number of I\/O points supported by the IC693CPU350?\u003c\/h4\u003e\n\u003cp\u003eThe IC693CPU350 supports up to 2,048 discrete inputs and 2,048 discrete outputs, providing ample capacity for extensive field device integration.\u003c\/p\u003e\n\u003ch4\u003eDoes this CPU require a specific slot in the baseplate?\u003c\/h4\u003e\n\u003cp\u003eYes, the IC693CPU350 must be installed in Slot 1 of a Series 90-30 CPU-capable baseplate to interface correctly with the system bus and power supply.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746716561660,"sku":"IC693CPU350","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC693CPU350.jpg?v=1773816257"},{"product_id":"ic694mdl240-ge-fanuc-digital-input-module","title":"IC694MDL240 GE Fanuc Digital Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IC694MDL240 (Revision IC694MDL240A) is a high-density alternating current (AC) input module engineered for the PACSystems RX3i controller platform. This module features 16 discrete input points designed to interface with field devices such as limit switches, pushbuttons, and electronic proximity sensors operating at a nominal 120 VAC. The module faceplate is color-coded with a red band to signify its high-voltage classification within the I\/O chassis, ensuring operational safety.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 VAC (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 (Single group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuitry\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReactive (Resistor\/Capacitor) design for noise suppression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Green LEDs (One per point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90mA from 5V bus; 12mA from 3.3V bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField to Logic and Frame Ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 14.0 cm x 14.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.23 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny I\/O slot in RX3i Universal Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFunctional Design and Integration\u003c\/h3\u003e\n\u003cp\u003eEngineered for industrial resilience, the IC694MDL240 utilizes reactive input circuits to minimize heat dissipation while maintaining signal integrity. The module requires an external AC power source to excite the field devices. For diagnostic efficiency, the logic-side LEDs provide immediate visual verification of input states. It is fully \"hot-swappable\" in supported RX3i configurations, allowing for maintenance without requiring an entire system power-down.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eCan this module be used with 240 VAC inputs?\u003c\/h4\u003e\n\u003cp\u003eNo, the IC694MDL240 is rated strictly for 120 VAC nominal ranges. For 240 VAC applications, a compatible higher-voltage module must be selected to avoid hardware damage.\u003c\/p\u003e\n\u003ch4\u003eIs there a difference between the IC694MDL240 and the MDL640?\u003c\/h4\u003e\n\u003cp\u003eYes, the IC694MDL240 is an AC input module, whereas the MDL640 is designed for 24 VDC sinking\/sourcing inputs. They are not interchangeable in terms of field wiring.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746716594428,"sku":"IC694MDL240A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC694MDL240A2.jpg?v=1773816256"},{"product_id":"ic695cpu310-cpu-module-ge-fanuc","title":"IC695CPU310 CPU Module GE Fanuc","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695CPU310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance central processing unit (CPU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc PACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. Optimized for demanding industrial automation, this processor delivers rapid execution of complex control logic with deterministic timing, making it ideal for high-speed process management and real-time control applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC695CPU310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Speed\u003c\/td\u003e\n\u003ctd\u003e300 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Capacity\u003c\/td\u003e\n\u003ctd\u003e10 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-Volatile User Memory\u003c\/td\u003e\n\u003ctd\u003e10 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Execution Speed\u003c\/td\u003e\n\u003ctd\u003e0.195 ms per 1,000 Boolean instructions (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 serial ports (RS-232 \/ RS-485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eRX3i high-speed backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Weight\u003c\/td\u003e\n\u003ctd\u003e0.48 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e300 MHz CPU enables fast I\/O scanning and logic execution, minimizing latency in time-sensitive applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10 MB RAM for complex operations and 10 MB non-volatile memory preserves user programs and configuration data during power cycles.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual serial ports support RS-232 and RS-485, facilitating integration with HMIs, legacy instrumentation, and third-party devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for real-time industrial control tasks within the RX3i rack architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time process control in manufacturing and industrial plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed automation requiring precise I\/O timing and low-latency response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with additional communication modules for Ethernet or fieldbus protocols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData-intensive operations, including monitoring, logging, and control of critical machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the 300 MHz processor?\u003c\/strong\u003e\u003cbr\u003eThe high-speed CPU significantly reduces scan and logic execution times, enhancing control loop precision and responsiveness in time-critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this CPU support advanced network protocols?\u003c\/strong\u003e\u003cbr\u003eNative serial ports (RS-232\/RS-485) are included, and full network functionality (Ethernet, fieldbus) is enabled through additional RX3i communication modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is data maintained during power loss?\u003c\/strong\u003e\u003cbr\u003eThe 10 MB of non-volatile memory ensures that user programs and configuration data are preserved without the need for external batteries, maintaining system integrity.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723639548,"sku":"IC695CPU310","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC695CPU3101.jpg?v=1773387058"},{"product_id":"ge-fanuc-ic694mdl660-discrete-input-module","title":"GE Fanuc  IC694MDL660 Discrete Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL660\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density 32-point discrete input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc PACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour isolated groups of eight input channels\u003c\/strong\u003e, providing robust signal acquisition, flexible configuration, and excellent noise immunity in industrial control applications. Its compact, high-density design optimizes space in the rack while reliably monitoring 24 VDC field devices.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC694MDL660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 (4 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 – 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e11.5 – 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 – 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density discrete input monitoring in industrial automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnhanced noise immunity for mechanical switches and sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible multi-voltage configurations via isolated channel groups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack space optimization in PACSystems RX3i deployments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable Input Filtering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSelect filter times from 0.5 ms to 100 ms to suppress contact bounce, transients, and electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFour groups of eight inputs are electrically isolated for multi-voltage flexibility and improved safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChannel Status Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach input channel includes a dedicated front-panel LED for real-time logic state indication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the filter settings used for?\u003c\/strong\u003e\u003cbr\u003eFilter settings suppress unwanted noise, contact bounce, and transient signals, ensuring only valid input state changes are processed by the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the input groups electrically isolated?\u003c\/strong\u003e\u003cbr\u003eYes, the four groups of eight channels are fully isolated from each other, allowing separate power sources or voltage levels without interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I confirm the status of a specific input channel?\u003c\/strong\u003e\u003cbr\u003eEach channel has a dedicated LED:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eilluminated = Logic 1 (input active)\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoff = Logic 0 (inactive)\u003c\/strong\u003e.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723770620,"sku":"IC694MDL660","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC694MDL660.jpg?v=1773387059"},{"product_id":"ic694mdl754-discrete-output-module-ge-fanuc","title":"IC694MDL754 Discrete Output Module GE Fanuc","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694MDL754\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density 32-point discrete output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-30\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatforms. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eElectronic Short Circuit Protection (ESCP)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor enhanced reliability, making it ideal for precise switching of 12\/24 VDC loads in demanding industrial automation applications. Outputs are divided into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo isolated groups of 16\u003c\/strong\u003e, allowing flexible power segregation and minimizing cross-channel interference.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC694MDL754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30, PACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e32 (two isolated groups of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e12\/24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2 – 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e0.75 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC (1 minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e300 mA max from 5 VDC bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule ID\u003c\/td\u003e\n\u003ctd\u003e0x059h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eElectronic Short Circuit Protection (ESCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Characteristics\u003c\/td\u003e\n\u003ctd\u003eNo derating at 24 VDC; derating at 30 VDC above 42°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-density discrete output control in industrial automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSegregated control loops for different machine sections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable switching for 12\/24 VDC actuators, solenoids, and relays\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpace-constrained PLC or PACSystems racks requiring robust short-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does ESCP mean?\u003c\/strong\u003e\u003cbr\u003eESCP stands for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eElectronic Short Circuit Protection\u003c\/strong\u003e, which detects and limits current during a short-circuit event to prevent permanent damage to the module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module be used at 30 VDC in high temperatures?\u003c\/strong\u003e\u003cbr\u003eYes, but\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal derating applies above 42°C\u003c\/strong\u003e. Consult official derating curves to ensure safe operation at 30 VDC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the output groups independent?\u003c\/strong\u003e\u003cbr\u003eYes, the module has\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo isolated groups of 16 outputs\u003c\/strong\u003e, allowing separate power sources for each group to minimize interference and improve diagnostic clarity.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723836156,"sku":"IC694MDL754","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC694MDL7541.jpg?v=1773387059"},{"product_id":"ge-fanuc-ic698psa100e-rx7i-power-supply-module","title":"GE Fanuc IC698PSA100E RX7i Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC698PSA100E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability power supply module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc PACSystems RX7i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It provides regulated power to the CPU, communication modules, and high-density I\/O modules, ensuring stable operation in critical industrial automation applications. Its robust voltage regulation and thermal management make it ideal for demanding environments, including hazardous locations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC698PSA100E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX7i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Location\u003c\/td\u003e\n\u003ctd\u003eSlot 0 (leftmost position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Output\u003c\/td\u003e\n\u003ctd\u003e125 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Output\u003c\/td\u003e\n\u003ctd\u003e150 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor RX7i backplane modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econsistent voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross CPU, communication, and I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density automation systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehazardous environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith Class 1, Division 2 rating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the IC698PSA100E?\u003c\/strong\u003e\u003cbr\u003eIt converts input power into the standardized voltages required by the RX7i rack and its associated modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be installed in any slot?\u003c\/strong\u003e\u003cbr\u003eNo. For proper power distribution and safety, it must be installed in Slot 0 (the leftmost position) only.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with hazardous environments?\u003c\/strong\u003e\u003cbr\u003eYes, it carries a Class 1, Division 2 rating, making it suitable for use in areas with potential explosive gases or vapors when installed in a rated enclosure.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723868924,"sku":"IC698PSA100E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC698PSA100E1.jpg?v=1773387059"},{"product_id":"blank-slot-filler-module-ge-fanuc-ic694acc310","title":"Blank Slot Filler Module GE Fanuc IC694ACC310","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC694ACC310\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical blank slot filler\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-30 and PACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePLC baseplates. It occupies unused I\/O slots, protecting the backplane from dust, metallic debris, and environmental contaminants. This module helps maintain proper airflow, prevents hotspots, and preserves the structural and aesthetic uniformity of the PLC rack.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC694ACC310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30, PACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eBlank Slot \/ Dust Cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard PLC I\/O rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eGuards against dust, debris, and airflow disruption\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade plastic housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSeals\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eunused I\/O slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent contamination of backplane connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecabinet airflow patterns\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor optimal thermal management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtects sensitive backplane contacts from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoxidation and particulate damage\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eclean, uniform appearance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin PLC racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is it important to use the IC694ACC310?\u003c\/strong\u003e\u003cbr\u003eEmpty slots expose backplane connectors to dust and disrupt airflow, potentially causing hot spots and reducing component lifespan.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide any electrical connection?\u003c\/strong\u003e\u003cbr\u003eNo, it is purely mechanical and contains no circuitry; it does not interface with the PLC data bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all GE PLC racks?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with standard Series 90-30 and PACSystems RX3i I\/O racks but is not intended for non-standard or proprietary mounting systems.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723901692,"sku":"IC694ACC310","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC694ACC310.jpg?v=1773387058"},{"product_id":"ge-fanuc-ic695psd040-rx3i-24-vdc-power-supply-module","title":"GE Fanuc IC695PSD040 RX3i 24 VDC Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC695PSD040\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-efficiency DC power supply module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc PACSystems RX3i\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It converts a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto precise internal voltage rails, supplying\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5.1 VDC and 3.3 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the RX3i backplane. Designed for industrial-grade reliability, the module ensures stable operation of CPUs, communication interfaces, and I\/O components. Its dual-rail output and support for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edaisy-chaining\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emake it suitable for scalable and redundant control system architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC695PSD040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power\u003c\/td\u003e\n\u003ctd\u003e60 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 Amps (100 ms maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rail 1\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC (5.0–5.2 V), 0–6 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rail 2\u003c\/td\u003e\n\u003ctd\u003e3.3 VDC (3.1–3.5 V), 0–9 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e14–22 AWG wire per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Current Rating\u003c\/td\u003e\n\u003ctd\u003e6 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Architecture\u003c\/td\u003e\n\u003ctd\u003eUniversal Backplane (PCI Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpandability\u003c\/td\u003e\n\u003ctd\u003eSupports daisy-chaining of up to 2 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRX3i backplane slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProvides regulated DC power to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRX3i CPUs, communication modules, and I\/O packs\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant or expanded power configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia daisy-chaining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estable operation in harsh industrial environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith sensitive backplane electronics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimplifies installation with terminals accommodating multiple wire gauges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC695PSD040?\u003c\/strong\u003e\u003cbr\u003eIt converts 24 VDC field power into regulated 5.1 VDC and 3.3 VDC rails required by the RX3i backplane modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this power supply be used with Series 90-30 PLCs?\u003c\/strong\u003e\u003cbr\u003eNo; it is specifically designed for the RX3i Universal Backplane and is incompatible with Series 90-30 hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy would I daisy-chain two IC695PSD040 units?\u003c\/strong\u003e\u003cbr\u003eDaisy-chaining increases power availability, supporting high I\/O density systems and preventing voltage drops across the backplane, while also allowing for redundancy.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723934460,"sku":"IC695PSD040","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC695PSD0401.jpg?v=1773387058"},{"product_id":"discrete-input-module-ge-fanuc-ic693mdl240","title":"Discrete Input Module GE Fanuc IC693MDL240","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-point 120 VAC discrete input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-30 PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. Designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density industrial I\/O\u003c\/strong\u003e, it converts field-level AC signals from devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epushbuttons, limit switches, and auxiliary contacts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto digital data for the PLC CPU. The module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1500 VAC RMS optical isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field and logic circuits, protecting sensitive controller electronics from electrical transients and ensuring reliable operation in harsh industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC693MDL240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete AC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 – 132 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage Threshold\u003c\/td\u003e\n\u003ctd\u003e74 – 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage Threshold\u003c\/td\u003e\n\u003ctd\u003e0 – 20 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e12 mA nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Response Time\u003c\/td\u003e\n\u003ctd\u003e30 ms (On), 45 ms (Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA from 5 VDC backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (RMS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Weight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 I\/O rack slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120 VAC field devices\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith PLC logic circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitors\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epushbuttons, limit switches, relays, and auxiliary contacts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed, deterministic input detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrical isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect PLC logic from voltage transients\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLogicMaster 90-30, VersaPro, and Proficy Machine Edition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC693MDL240?\u003c\/strong\u003e\u003cbr\u003eIt converts 120 VAC signals from field devices into digital logic inputs for the Series 90-30 PLC CPU.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require external power for the input channels?\u003c\/strong\u003e\u003cbr\u003eNo; the AC inputs are powered by the connected field devices. The module’s logic circuits draw 5 VDC from the PLC backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be installed in any slot?\u003c\/strong\u003e\u003cbr\u003eYes, it can occupy any available I\/O slot on a Series 90-30 backplane, provided the system power supply can support its 90 mA consumption.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723967228,"sku":"IC693MDL240","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC693MDL2402.jpg?v=1773390794"},{"product_id":"ic693mdl930-ge-fanuc-relay-output-module","title":"IC693MDL930  GE Fanuc Relay Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL930\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8-point isolated relay output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-30 PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. Designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh versatility and industrial robustness\u003c\/strong\u003e, it allows the PLC to control both AC and DC loads across varying voltage levels while maintaining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echannel-to-channel and channel-to-logic isolation\u003c\/strong\u003e. Its relay-based outputs are ideal for driving\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einductive and high-current devices\u003c\/strong\u003e, providing reliable electrical separation to protect sensitive PLC logic in heavy industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC693MDL930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e8 Form A (Normally Open) isolated relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range (AC)\u003c\/td\u003e\n\u003ctd\u003e5 – 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range (DC)\u003c\/td\u003e\n\u003ctd\u003e5 – 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Point\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (channel-to-channel and channel-to-logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 I\/O rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew-terminal interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDrives\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediverse field devices\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as contactors, solenoids, and indicator lamps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHandles\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emixed-voltage systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere separate power circuits must remain isolated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIdeal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith appropriate suppression circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLC logic protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial switching applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-voltage process control and automation tasks\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of an isolated relay module like the IC693MDL930?\u003c\/strong\u003e\u003cbr\u003eIsolation allows each channel to switch different voltages safely while protecting the PLC from faults and transient spikes in the load circuits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module handle inductive loads?\u003c\/strong\u003e\u003cbr\u003eYes, it can handle standard inductive loads. For high-inductance devices, external suppression (snubber circuits or flyback diodes) is recommended to extend relay life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the expected service life of these relays?\u003c\/strong\u003e\u003cbr\u003eRelay longevity depends on the load type and switching frequency. Under typical industrial conditions within rated limits, the relays provide reliable long-term operation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746723999996,"sku":"IC693MDL930","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC693MDL9302.jpg?v=1773387058"},{"product_id":"cpu-module-ge-fanuc-ic693cpu331","title":"CPU Module GE Fanuc IC693CPU331","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693CPU331\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-slot CPU module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-30 PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. Designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand reliable I\/O management, it executes user logic, scans I\/O modules, and facilitates backplane communication across the PLC system. Its compact form factor and proven stability make it ideal for small to mid-sized industrial automation tasks requiring sequential control, status monitoring, and data logging.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC693CPU331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003e80188, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Speed\u003c\/td\u003e\n\u003ctd\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 512 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegister Memory\u003c\/td\u003e\n\u003ctd\u003e4 KBytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMath Capabilities\u003c\/td\u003e\n\u003ctd\u003eInteger operations only (no floating-point hardware)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e350 mA at +5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e18 cm x 6 cm x 18 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eActs as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral processing unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Series 90-30 PLC systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExecutes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003euser-defined sequential control logic\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O modules, communication adapters, and specialty modules\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManages\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esmall to mid-sized industrial automation systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata logging, status monitoring, and standard machine sequence control\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC693CPU331?\u003c\/strong\u003e\u003cbr\u003eIt serves as the CPU of the Series 90-30 PLC, executing control logic and managing I\/O data exchanges across the system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC693CPU331 support floating-point operations?\u003c\/strong\u003e\u003cbr\u003eNo, it only supports standard integer math and logic. Floating-point calculations are not natively supported by the hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the CPU receives voltage above 5 VDC?\u003c\/strong\u003e\u003cbr\u003eExceeding the 5 V rating can cause processor resets, logic errors, or permanent damage to the power circuitry. Proper power regulation is essential for reliable operation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746724032764,"sku":"IC693CPU331","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC693CPU331.jpg?v=1773387059"},{"product_id":"ge-fanuc-ic693mdl330-discrete-output-module","title":"GE Fanuc IC693MDL330 Discrete Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693MDL330\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e120 VAC discrete output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Series 90-30 PLC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight isolated output channels\u003c\/strong\u003e, enabling precise control of AC-powered devices such as motor starters, solenoids, and indicator lamps. Engineered for rugged industrial conditions, the module delivers consistent signal switching while protecting the PLC logic from electrical interference and transients, making it ideal for automated manufacturing and process control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC693MDL330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 8-Point Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e85–132 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current per Point\u003c\/td\u003e\n\u003ctd\u003e2.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation between field and logic side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSeries 90-30 I\/O Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eStandard screw-terminal field wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInterfaces Series 90-30 PLC outputs with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC-powered field devices\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafely actuates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotor starters, solenoids, and indicator lamps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoptical isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto protect PLC logic from voltage spikes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edense I\/O configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor compact control panel designs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial process control, assembly automation, and factory applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC693MDL330?\u003c\/strong\u003e\u003cbr\u003eIt allows the Series 90-30 PLC to switch 120 VAC power to external devices such as relays, motor starters, or lamps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the IC693MDL330 compatible with all Series 90-30 racks?\u003c\/strong\u003e\u003cbr\u003eYes, it fits standard Series 90-30 I\/O baseplates and is compatible with any CPU module within the 90-30 family.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module protect against electrical faults?\u003c\/strong\u003e\u003cbr\u003eIt features optical isolation to shield the PLC logic from high-voltage transients and includes replaceable fuses for short-circuit protection on each output group.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746724098300,"sku":"IC693MDL330","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC693MDL3301.jpg?v=1773387059"},{"product_id":"expansion-terminator-module-ge-fanuc-versamax-series-ic200acc201","title":"Expansion Terminator Module GE Fanuc VersaMax Series IC200ACC201","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical component within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc VersaMax PLC architecture\u003c\/strong\u003e. As an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexpansion terminator\u003c\/strong\u003e, it is specifically designed to terminate the final expansion receiver in a communication chain. By providing essential signal termination, this module prevents\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal reflection\u003c\/strong\u003e, ensuring the long-term integrity and reliability of the data bus. It is a vital spare part for maintaining uptime in complex industrial control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC200ACC201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminates the last expansion receiver in a chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExclusively for VersaMax PLC systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-tier industrial control networks\u003c\/strong\u003e, where multiple I\/O racks are daisy-chained. Proper termination at the final node is crucial to eliminate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal bouncing\u003c\/strong\u003e, which can cause intermittent communication errors or total system failures. Its robust environmental ratings make it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efactory floor conditions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas well as more\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edemanding industrial environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the IC200ACC201 necessary?\u003c\/strong\u003e\u003cbr\u003eWithout proper termination at the end of an expansion cable, signal reflections can cause interference, leading to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata corruption\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication timeouts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween the CPU and remote I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this terminator be used with other PLC series?\u003c\/strong\u003e\u003cbr\u003eNo, the IC200ACC201 is specifically designed for the communication protocols used within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax PLC system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if this module fails?\u003c\/strong\u003e\u003cbr\u003eA faulty or missing terminator often results in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"bus error\" diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the PLC, which can cause the system to stop communicating with remote expansion modules. It is recommended to keep this spare on hand for rapid maintenance.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730062076,"sku":"IC200ACC201","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG230.jpg?v=1773299425"},{"product_id":"ic200alg230-ge-fanuc-versamax-analog-input-module","title":"IC200ALG230 GE Fanuc VersaMax Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-channel analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc VersaMax programmable logic controller (PLC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This module offers high-precision signal processing for industrial instrumentation, with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-bit resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor both voltage and current loop inputs. Its small footprint and integrated design make it ideal for space-constrained control panels, ensuring reliable analog data acquisition in various industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC200ALG230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Input Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage and Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax PLC System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact modular architecture for easy DIN-rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard opto-isolation for logic-to-field signal protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed scanning suitable for standard process loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG230 is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esmall-scale automation projects\u003c\/strong\u003e, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emachine monitoring\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esecondary process controls\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especialized laboratory automation\u003c\/strong\u003e. It is most suitable for applications that require standard resolution for sensors such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure gauges\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflow meters\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epotentiometric sensors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this model and the high-density versions?\u003c\/strong\u003e\u003cbr\u003eThe IC200ALG230 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-channel module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-bit resolution\u003c\/strong\u003e, making it a more economical option for applications that do not require the higher channel counts or the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-bit precision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efound in advanced models.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes, the IC200ALG230 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping\u003c\/strong\u003e, similar to other components in the VersaMax I\/O family. This feature allows for maintenance without interrupting backplane communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support universal inputs?\u003c\/strong\u003e\u003cbr\u003eThe module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent input ranges\u003c\/strong\u003e, and these are configurable to meet the specific needs of connected field sensors.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730094844,"sku":"IC200ALG230","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG230.jpg?v=1773299425"},{"product_id":"ge-fanuc-ic200alg240-versamax-analog-input-module","title":"GE Fanuc IC200ALG240 VersaMax Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc VersaMax PLC system\u003c\/strong\u003e. This module features eight channels, each fully isolated to protect signal integrity and prevent ground loops in complex industrial environments. It supports both voltage and current loop inputs, making it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einstrumentation applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat demand high precision.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC200ALG240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Independent Channels, Channel-to-Channel Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10 VDC or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e381 nA (Current mode), 381 µV (Voltage mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mA max at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Power Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5-30 VDC (includes ripple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA max plus connected load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms (50 Hz filter), 16.7 ms (60 Hz filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 cm x 11 cm x 6.68 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG240 is specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata acquisition systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere signal noise immunity is critical. It is ideal for use cases involving pressure, flow, and temperature transmitters in industries such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewater management\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediscrete manufacturing\u003c\/strong\u003e. Its isolated design ensures accurate signal conversion even when sensors are at different potential levels or located at varying distances.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the channel-to-channel isolation?\u003c\/strong\u003e\u003cbr\u003eThe isolation ensures that electrical noise or ground potential differences from one sensor circuit do not affect the readings of other channels, providing high signal fidelity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power to function?\u003c\/strong\u003e\u003cbr\u003eYes, external field power of 19.5-30 VDC is required to power the input circuitry and the connected sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module measure both current and voltage on the same module?\u003c\/strong\u003e\u003cbr\u003eYes, the input type is selectable on a per-channel basis, allowing you to mix current and voltage inputs within the same IC200ALG240 module.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730127612,"sku":"IC200ALG240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG240.jpg?v=1773299425"},{"product_id":"ic200alg321-analog-voltage-output-module-ge-fanuc","title":"IC200ALG321 Analog Voltage Output Module GE Fanuc","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200ALG321\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 4-channel analog voltage output module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE VersaMax I\/O\u003c\/strong\u003e. It delivers precise 0–10 VDC signals for industrial control applications, interfacing with devices like proportional valves, VFDs, and data loggers. With 12-bit resolution and built-in diagnostics, it ensures high-fidelity control in automated systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eIC200ALG321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 analog voltage outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC (nominal), up to 10.24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (2.5 mV per bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.3% typical, 1% max full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e0.3 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18–30 VDC or 9.6–15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous \/ 1500 VAC (1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFast 0.3 ms update rate for dynamic control loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanic isolation protects both field devices and logic circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED indicators provide instant feedback on backplane and field power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-ended wiring simplifies installation in industrial panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for precision analog control in automated manufacturing and process systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaintenance and Diagnostics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOn-board LEDs indicate module health and help isolate field or communication issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports flexible DC input voltages for varied industrial power setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution output ensures precise linearity and repeatability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200ALG321 be used for current outputs?\u003c\/strong\u003e\u003cbr\u003eNo. This module is strictly for 0–10 VDC voltage outputs. Use VersaMax current output modules for mA loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module configured within VersaMax systems?\u003c\/strong\u003e\u003cbr\u003eOutput scaling and default states are set through the PLC software during hardware setup.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730160380,"sku":"IC200ALG321","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG321.jpg?v=1773212383"},{"product_id":"ge-multilin-ur-6ch-digital-i-o-control-module","title":"GE Multilin UR 6CH Digital I\/O Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 6CH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital input\/output module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides additional binary I\/O points to monitor substation sensors, status contacts, and control signals, supporting deterministic performance for critical industrial applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 6CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial substation automation and relay logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExpands digital control and feedback points in UR relay racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffloads I\/O management to streamline complex automation logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports precise control of switchgear and protection equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for high-availability environments requiring consistent signal processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the UR 6CH interface with the relay system?\u003c\/strong\u003e\u003cbr\u003eIt connects to the UR internal backplane and is automatically recognized by the CPU for logic configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR 6CH compatible with all UR chassis versions?\u003c\/strong\u003e\u003cbr\u003eGenerally yes, but verify CPU firmware and rack revision to ensure full operational compatibility.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730356988,"sku":"UR6CH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-6fh-digital-i-o-control-module-ge-multilin","title":"UR 6FH Digital I\/O Control Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 6FH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital input\/output module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides reliable digital signaling for monitoring and control, enabling high-performance automation and protection in industrial substation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eUR 6FH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Integration\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial substation automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed digital state detection and command execution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless integration within UR rack architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable via EnerVista UR for customized protection logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt to meet industrial standards for reliability and signal availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the I\/O points?\u003c\/strong\u003e\u003cbr\u003eUse EnerVista UR software to assign functions, monitor status, and run diagnostics for each channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with all UR relay chassis?\u003c\/strong\u003e\u003cbr\u003eGenerally yes, but verify your rack serial number and firmware version to ensure correct CPU recognition.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730389756,"sku":"UR67H","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8LH.jpg?v=1773216372"},{"product_id":"ur-8fh-analog-input-module-ge-multilin","title":"UR 8FH Analog Input Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8FH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a horizontal-format analog input module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides precise analog signal acquisition for monitoring electrical parameters, enabling the relay to execute real-time protection logic and maintain grid stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8FH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eHorizontal Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e40 mm × 185 mm × 172 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSubstation protection and measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-precision analog signal acquisition for relay protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable interface between primary sensors and relay CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHorizontal layout for seamless integration into UR racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for industrial thermal and electromagnetic conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR 8FH hot-swappable?\u003c\/strong\u003e\u003cbr\u003eNo. Power must be removed from the UR rack before installing or replacing the module to protect the backplane and communication bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify compatibility with my UR rack?\u003c\/strong\u003e\u003cbr\u003eCheck your relay chassis version and firmware against the UR 8FH specifications in the hardware manual to ensure proper fit and operation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730619132,"sku":"UR 8FH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH1.jpg?v=1773216372"},{"product_id":"ur-8hh-ct-vt-analog-input-module-ge-multilin","title":"UR 8HH CT VT Analog Input Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8HH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated analog measurement module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It interfaces with current and voltage transformers (CTs and VTs) to step down high-magnitude primary signals, providing precise 1A\/5A phase and ground current measurements.\u003c\/p\u003e\n\u003cp\u003eThis accuracy enables the relay to execute protective functions reliably and maintain power system stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8HH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003e3 × 1A\/5A phase CTs, 1 × 1A\/5A ground CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Integration\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8HH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates seamlessly into the UR chassis, enabling high-fidelity data acquisition. Measurements can be displayed on the relay’s local LCD or exported via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor detailed analysis. The module supports customizable protection schemes, allowing engineers to set site-specific thresholds and monitor system conditions in real time while preserving signal integrity from field sensors to the relay CPU.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the UR 8HH be configured for different CT ratios?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports programmable CT\/VT scaling through\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e, allowing adaptation to various primary sensor ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eNo. Always de-energize the relay rack and follow lockout\/tagout procedures before inserting or removing the UR 8HH to prevent electrical hazards and bus communication errors.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730848508,"sku":"UR8HH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-9eh-cpu-processor-module-ge-multilin","title":"UR 9EH CPU Processor Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a core processing module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. Serving as the primary computational engine of the relay, the UR 9EH handles critical operations such as complex logic algorithms, latching sequences, and precise timing functions essential for power system protection.\u003c\/p\u003e\n\u003cp\u003eThe module is suitable for both upgrading legacy systems and replacing existing CPUs, ensuring reliable performance and integration within the UR platform.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eUR 9EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCentral Processing Unit (CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.5 in × 6 in × 2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIntegration and Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlug \u0026amp; Play functionality\u003c\/strong\u003e, allowing the system to auto-detect and initialize settings upon startup. To ensure operational stability and prevent errors such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHARDWARE MISMATCH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSP ERROR\u003c\/strong\u003e, the CPU module generation must match the CT\/VT module generation.\u003c\/p\u003e\n\u003cp\u003eNew UR 9EH modules should be paired with modern CT\/VT counterparts, while legacy CPU modules should remain paired with older analog input modules to maintain communication integrity across the UR relay system.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Optimization\u003c\/h3\u003e\n\u003cp\u003eThe module is fully configurable through the relay’s front-panel keypad or via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e. Advanced users can optimize CPU performance by selectively disabling features, such as server scanning, which frees resources if\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 client\/server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication is not required in the network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older UR CPU with a new UR 9EH without updating other modules?\u003c\/strong\u003e\u003cbr\u003eCompatibility is version-dependent. Installing a new\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealongside older CT\/VT modules may lead to communication errors. Always verify the compatibility of your existing backplane and I\/O modules before performing upgrades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I free up resources on this CPU?\u003c\/strong\u003e\u003cbr\u003eThrough\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e, non-essential features like server scanning can be disabled to optimize CPU performance, especially if IEC 61850 communication is not being utilized in your specific system.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731012348,"sku":"UR9EH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-rhh-ge-multilin-power-supply-module","title":"UR RHH GE Multilin Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized power supply module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides stable and regulated power to relay electronics, ensuring reliable operation of mission-critical protection and control functions in substation environments.\u003c\/p\u003e\n\u003cp\u003eWith robust construction and dependable DC\/AC conversion capabilities, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential component for maintaining continuous uptime and optimal performance within the UR relay architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR RHH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDC\/AC Power Input Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e40 mm × 225 mm × 292 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance and Reliability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to provide consistent voltage to internal relay components, preventing performance degradation or data errors during transient grid disturbances. Its compact, rack-mountable design allows easy integration into existing UR hardware assemblies, supporting efficient use of substation panel space.\u003c\/p\u003e\n\u003cp\u003eBuilt to withstand industrial thermal and electrical stresses, the module ensures reliable operation of UR relays even under challenging environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR RHH compatible with all Universal Relay (UR) chassis types?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for the UR relay family; however, compatibility depends on the specific relay backplane version and the power requirements of connected CPU and modules. Always verify hardware specifications before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require cooling fans for operation?\u003c\/strong\u003e\u003cbr\u003eNo. The module is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econvection cooling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin standard UR relay housings. Ensure that the rack installation allows adequate airflow as recommended in the installation manual to maintain optimal operating temperatures.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731438332,"sku":"URRHH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR-RHH.jpg?v=1773212383"},{"product_id":"ur-8nh-ge-multilin-ct-vt-analog-input-module","title":"UR 8NH  GE Multilin CT VT Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized analog input module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It delivers high-fidelity acquisition of current transformer (CT) and voltage transformer (VT) signals, enabling precise waveform monitoring and accurate data processing for advanced power system protection schemes.\u003c\/p\u003e\n\u003cp\u003eEngineered for critical electrical infrastructure, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a key interface between field measurement devices and the relay’s central processing unit. With integrated diagnostic capabilities and high-resolution analog-to-digital conversion, the module ensures reliable signal acquisition for substation protection and automation applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8NH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eCT\/VT Analog Measurement Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.75 in × 10.50 in × 4.50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003eHigh-precision analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eReal-time internal channel monitoring and self-test routines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a critical interface between primary measurement sensors and the relay’s protection logic. By continuously monitoring internal channel performance, the module can quickly detect anomalies or hardware faults that may affect measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eIf a malfunction is detected, the system can automatically block associated protection trip commands, ensuring that protection actions are based only on verified and reliable measurement data. This safeguard helps prevent nuisance tripping and enhances the operational security of the power system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the UR 8NH require manual configuration after installation?\u003c\/strong\u003e\u003cbr\u003eYes. After installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule, the relay must be configured using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e. This configuration step maps CT and VT inputs to the appropriate protection elements within the relay logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older UR relay chassis models?\u003c\/strong\u003e\u003cbr\u003eCompatibility depends on the CPU firmware version and the backplane revision of the relay chassis. It is recommended to verify the rack serial number and firmware version against the module’s technical documentation before installation to ensure proper system integration.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731962620,"sku":"UR8NH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH1.jpg?v=1773216372"},{"product_id":"ge-multilin-ur-8lh-analog-ct-vt-input-module","title":"GE Multilin UR 8LH Analog CT VT Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog input module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. Designed for mission-critical substation automation, the module provides accurate acquisition of current transformer (CT) and voltage transformer (VT) signals, enabling reliable protection, monitoring, and measurement for electrical power systems.\u003c\/p\u003e\n\u003cp\u003eWith advanced signal conditioning and built-in diagnostics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures stable data acquisition while supporting the protection logic of the relay system. Its robust construction and integrated monitoring functions help maintain system integrity in demanding utility and industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCT\/VT Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Series\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Supply\u003c\/td\u003e\n\u003ctd\u003e100–240 V AC, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Thermal Range\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm × 150 mm × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Capability\u003c\/td\u003e\n\u003ctd\u003eIntegrated self-monitoring for analog signal integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Interlocks\u003c\/td\u003e\n\u003ctd\u003eAutomatic fault-triggered alarm and protection blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates advanced diagnostic algorithms that continuously monitor the integrity of analog input channels. If a measurement anomaly or internal hardware issue is detected, the module automatically generates a system alarm and temporarily blocks associated relay trip outputs. This protective mechanism prevents false operations and enhances overall system safety.\u003c\/p\u003e\n\u003cp\u003eFor optimal performance, proper system integration requires verification of CPU firmware compatibility within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack assembly. Ensuring firmware alignment allows the module to communicate effectively with other relay components and maintain accurate data processing across the protection system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable in a running UR chassis?\u003c\/strong\u003e\u003cbr\u003eIt is strongly recommended to de-energize the relay rack before inserting or removing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule. This precaution helps prevent electrical transients and avoids potential communication errors on the relay backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle sensor calibration?\u003c\/strong\u003e\u003cbr\u003eThe module supports digital calibration through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR configuration software suite\u003c\/strong\u003e, allowing engineers to adjust CT and VT ratio parameters during system commissioning to ensure accurate measurement and protection performance.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746732028156,"sku":"UR8LH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8LH.jpg?v=1773216372"},{"product_id":"ge-multilin-g60-generator-management-protection-relay","title":"GE Multilin G60 Generator Management Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated protection and control terminal specifically engineered for the management of medium and large synchronous generators. It delivers a comprehensive suite of protection, monitoring, and control functions within a highly modular hardware architecture, ensuring maximum availability and reliability for critical power generation assets.\u003c\/p\u003e\n\u003cp\u003eAs part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e, the G60 combines advanced generator protection algorithms with integrated metering, disturbance recording, and flexible communication capabilities. This allows operators and engineers to maintain system stability while gaining deep insight into generator operating conditions and fault events.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Model\u003c\/td\u003e\n\u003ctd\u003eGE Multilin G60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Suite\u003c\/td\u003e\n\u003ctd\u003eDifferential, out-of-step, loss-of-field, stator ground fault, pole slip, overcurrent, and voltage-based protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Metering\u003c\/td\u003e\n\u003ctd\u003eReal-time monitoring of voltage, current, power, and energy parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Configuration\u003c\/td\u003e\n\u003ctd\u003eModular draw-out design available in single-bay and multi-bay formats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eHigh-contrast menu-driven backlit LCD for local diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisturbance Analysis\u003c\/td\u003e\n\u003ctd\u003eAdvanced event and fault recording for post-event system analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in power generation facilities to protect synchronous generators and associated transformers. Its advanced generator-specific protection algorithms make it particularly valuable in thermal, hydroelectric, and combined-cycle power plants.\u003c\/p\u003e\n\u003cp\u003eBeyond traditional utility environments, the relay is also used in large industrial facilities for motor protection and control, as well as in renewable energy infrastructure such as wind and solar farms where generator protection and grid interconnection reliability are critical.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes the G60 suitable for power plants?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates specialized protection algorithms designed specifically for generator operating conditions, including loss-of-field detection, pole-slip protection, and out-of-step protection—functions not typically available in standard protection relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the device support modern SCADA environments?\u003c\/strong\u003e\u003cbr\u003eYes. The relay supports multiple industry-standard communication protocols, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDNP3\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e, enabling seamless integration with modern SCADA and substation automation systems.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733043964,"sku":"G60","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/G601.jpg?v=1773212380"},{"product_id":"ge-multilin-t35-transformer-protection-relay-system","title":"GE Multilin T35 Transformer Protection Relay System","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a comprehensive three-phase transformer management relay engineered for the primary protection and monitoring of power transformer assets. This digital protection device integrates advanced protection algorithms with flexible automation capabilities, enabling high-speed fault detection and dependable operation in demanding electrical distribution environments.\u003c\/p\u003e\n\u003cp\u003eDesigned as part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e, the T35 provides sophisticated transformer differential protection, harmonic restraint, thermal monitoring, and event recording. These capabilities allow operators to maintain system stability while protecting valuable transformer infrastructure in both utility and industrial power networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Model\u003c\/td\u003e\n\u003ctd\u003eGE Multilin T35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Power Input\u003c\/td\u003e\n\u003ctd\u003e125 \/ 250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Channels\u003c\/td\u003e\n\u003ctd\u003e3 × 1A \/ 5A Phase CTs + 1 × 1A \/ 5A Ground CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Channels\u003c\/td\u003e\n\u003ctd\u003e4 × 120V \/ 240V VTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relay Ratings\u003c\/td\u003e\n\u003ctd\u003e24V DC to 250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in utility substations and industrial power systems where reliable transformer protection is critical. It is specifically designed to safeguard medium-to-large power transformers and supports advanced protection schemes such as transformer differential protection, harmonic blocking, and thermal overload monitoring.\u003c\/p\u003e\n\u003cp\u003eBy integrating multiple protection and monitoring functions into a single platform, the relay provides operators with a comprehensive view of transformer health, helping to minimize downtime and prevent catastrophic equipment failures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the T35 relay?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a dedicated transformer protection relay. It processes CT and VT inputs to detect internal faults, abnormal current conditions, and thermal overload situations, enabling fast and reliable tripping to protect critical power assets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the device suitable for extreme outdoor environments?\u003c\/strong\u003e\u003cbr\u003eYes. With an operating temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C to +85°C\u003c\/strong\u003e, the relay is engineered to operate reliably in harsh industrial and substation environments, including installations without climate-controlled enclosures.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733076732,"sku":"T35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/T35.jpg?v=1773212382"},{"product_id":"ge-multilin-f35-feeder-protection-relay","title":"GE Multilin F35 Feeder Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin F35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efeeder protection relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to safeguard medium- and high-voltage distribution networks. Part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR (Universal Relay) family\u003c\/strong\u003e, it delivers advanced protection, control, and monitoring for feeders, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003earc-flash detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebreaker failure protection\u003c\/strong\u003e. Its modular architecture supports customizable I\/O configurations, making it ideal for complex industrial and utility substation applications.\u003c\/p\u003e\n\u003cp\u003eEngineered for digital substations, the F35 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-fidelity disturbance recording\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eevent logging\u003c\/strong\u003e, and robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 communication\u003c\/strong\u003e, enabling seamless integration into automated grid systems. Its intuitive interface and diagnostic tools enhance feeder management while reducing downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eF35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFeeder Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Protection Elements\u003c\/td\u003e\n\u003ctd\u003eOvercurrent, Voltage, Frequency, Directional Power, Breaker Failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Diagnostics\u003c\/td\u003e\n\u003ctd\u003eArc-Flash Detection, Waveform Capture, Sequence of Events (SOE) Recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, Modbus, DNP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Architecture\u003c\/td\u003e\n\u003ctd\u003eUR (Universal Relay) Modular Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003eLarge graphical display for metering and status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eRole-based access control, security auditing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Arc-Flash Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed light and current sensing reduces equipment damage and enhances personnel safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlexible UR platform allows expansion of I\/O boards for complex feeder requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCOMTRADE-compliant disturbance and fault data for in-depth analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt for consistent performance under extreme electrical and thermal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F35 support integration with IEC 61850 substations?\u003c\/strong\u003e\u003cbr\u003eYes, it is fully compliant with IEC 61850, supporting GOOSE messaging for fast protection and interoperability in digital substations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the F35 detect arc flashes?\u003c\/strong\u003e\u003cbr\u003eYes, the relay includes dedicated arc-flash detection logic. When paired with light-sensitive sensors, it delivers rapid response to clear arc faults in switchgear.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733142268,"sku":"F35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F35-F53U04-HKH.jpg?v=1773133040"},{"product_id":"ge-multilin-239-an-h-motor-protection-relay","title":"GE Multilin 239-AN-H Motor Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin 239-AN-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicroprocessor-based motor protection relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for three-phase AC motors and their drive systems. Part of the 239 series, it provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomprehensive protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincluding thermal overload, phase unbalance, jam detection, undercurrent, and ground fault monitoring. The “-H” designation indicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eharsh environment conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor protection against moisture, dust, and chemical exposure.\u003c\/p\u003e\n\u003cp\u003eThe relay supports a wide AC\/DC supply range and connects to automation networks via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS485 Modbus RTU\u003c\/strong\u003e, enabling remote monitoring and configuration. Its robust design helps prevent motor damage, reduce downtime, and extend asset life in demanding industrial settings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e239-AN-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Elements\u003c\/td\u003e\n\u003ctd\u003eThermal Overload, Ground Fault, Phase Unbalance, Jam, Undercurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e70–265 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e30 W \/ 30 VA Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e10 A at 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485 (Modbus RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eHarsh Environment Conformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.81 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Inhibit Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrevents motor restart until thermal conditions are safe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal coating protects against dust, humidity, and corrosive conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS485 enables remote monitoring and parameter adjustments via SCADA\/PLC systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProven Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSolid-state platform provides precise protection even in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 239-AN-H require external hardware for ground fault protection?\u003c\/strong\u003e\u003cbr\u003eNo, the relay includes integrated ground fault protection, but CT configuration must match the motor circuit design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the communication port be used to program the relay settings?\u003c\/strong\u003e\u003cbr\u003eYes, the RS485 Modbus RTU port allows full remote configuration and status monitoring with compatible software.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733633788,"sku":"239-AN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/239-AN.jpg?v=1773126954"},{"product_id":"ge-fanuc-d25-industrial-rtu-control-device","title":"GE Fanuc D25 Industrial RTU Control Device","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc D25-0158-000002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance industrial control and monitoring device\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat consolidates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTU, PLC, and power quality monitoring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions into a single unit. Designed for demanding industrial and utility environments, it enables precise data acquisition, rapid control response, and advanced diagnostics for complex automation systems. Housed in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e19-inch rack-mount chassis\u003c\/strong\u003e, the device integrates seamlessly into standard control cabinets and relay panels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eD25-0158-000002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIndustrial Control \u0026amp; Monitoring Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e19-inch Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Capabilities\u003c\/td\u003e\n\u003ctd\u003eRTU, PLC, Power Quality Monitoring, Protective Relaying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Features\u003c\/td\u003e\n\u003ctd\u003eDigital Fault Recording (DFR), Sequence of Events (SOE), Precision Metering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Automation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCombines PLC logic control and RTU telemetry in a single unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-fidelity monitoring for power quality, faults, and sequence-of-events logging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Communications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports versatile industrial network integration for complex monitoring schemes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandardized Form Factor:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e19-inch rack-mount design allows dense installation and compatibility with existing panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the D25-0158-000002 execute local programmable logic?\u003c\/strong\u003e\u003cbr\u003eYes, it has built-in PLC functionality, enabling execution of custom logic locally without external controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this device suitable for substation fault analysis?\u003c\/strong\u003e\u003cbr\u003eAbsolutely. It provides Digital Fault Recording (DFR) and Sequence of Events (SOE) logging, essential for diagnosing electrical disturbances in substation environments.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733699324,"sku":"D25","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/D25.jpg?v=1773126953"},{"product_id":"ge-multilin-m60-motor-protection-system-industrial-relay","title":"GE Multilin M60 Motor Protection System Industrial Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin M60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotor protection system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emedium to large three-phase induction motors\u003c\/strong\u003e. It delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadvanced protection, control, and diagnostics\u003c\/strong\u003e, making it ideal for mission-critical industrial applications. The M60 features flexible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal overload models\u003c\/strong\u003e—standard, custom, and voltage-dependent—ensuring precise motor safeguarding under varied operating conditions.\u003c\/p\u003e\n\u003cp\u003eWith native\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 support\u003c\/strong\u003e, including SCL integration and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR-GOOSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication, the system enables modern digital substation connectivity. Security is ensured with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-permission access controls\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand detailed command logging. Configuration is simplified through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista M60 Autoconfigurator\u003c\/strong\u003e, and the system provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density programmable I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOMTRADE 2013-compliant waveform capture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor advanced disturbance analysis.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eMultilin M60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMedium to large three-phase induction motor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Curves\u003c\/td\u003e\n\u003ctd\u003eStandard, Custom, Voltage-dependent thermal models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, R-GOOSE, Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording Standards\u003c\/td\u003e\n\u003ctd\u003eCOMTRADE 2013 (Waveform Capture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eDual-permission access, user command logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eFull-color, high-resolution interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eHigh-density programmable I\/O, flexible process bus support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFault and disturbance recording for in-depth post-event analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutoconfigurator reduces engineering time and streamlines logic deployment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScalable I\/O to meet complex automation requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePermission-based access and command logging protect critical system changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the M60 support IEC 61850 network integration?\u003c\/strong\u003e\u003cbr\u003eYes. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflexible process bus architectures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCL file integration\u003c\/strong\u003e, enabling seamless integration into modern digital substations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the M60 record waveform data for fault analysis?\u003c\/strong\u003e\u003cbr\u003eYes. The M60 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOMTRADE 2013-compliant waveform capture\u003c\/strong\u003e, facilitating detailed disturbance and fault event analysis.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746734387452,"sku":"M60","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/M601.jpg?v=1773130971"},{"product_id":"ge-fanuc-ic670gbi002-field-control-genius-bus-interface-unit","title":"GE Fanuc IC670GBI002 Field Control Genius Bus Interface Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670GBI002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary Bus Interface Unit (BIU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Field Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. It enables high-speed communication between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaster controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGenius Bus protocol\u003c\/strong\u003e. Supporting up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 field modules\u003c\/strong\u003e, it handles\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e128 bytes of input and output data per cycle\u003c\/strong\u003e, serving as a reliable bridge for industrial automation networks.\u003c\/p\u003e\n\u003cp\u003eThe unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIN-rail mountable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor secure installation and operates on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24V DC nominal power\u003c\/strong\u003e, with integrated 6.5V DC backplane supply for connected modules. With a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMean Time Before Failure (MTBF) of 183,000 hours\u003c\/strong\u003e, it is engineered for long-term reliability in critical control systems, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swappable modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor minimal maintenance downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670GBI002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 Field I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Capacity\u003c\/td\u003e\n\u003ctd\u003e128 Bytes Input \/ 128 Bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLong MTBF for continuous operation in critical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports module insertion\/removal without full system shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for Genius Bus integration between master controller and I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDedicated terminal strips for power, communication, and module connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC670GBI002 require a specific DIN rail for grounding?\u003c\/strong\u003e\u003cbr\u003eYes. Use a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-conductivity, corrosion-resistant DIN rail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure stable low-impedance grounding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I hot-swap I\/O modules while the BIU is powered?\u003c\/strong\u003e\u003cbr\u003eYes. Hot insertion and removal are supported\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eif the installed I\/O modules are compatible\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith hot-swap operations.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746734420220,"sku":"IC670GBI002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670GBI002.jpg?v=1773126954"},{"product_id":"ge-fanuc-ic670chs101-control-relay-module-for-field-control","title":"GE Fanuc IC670CHS101 Control Relay Module for Field Control","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670CHS101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a control relay module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Field Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries, designed to interface\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow-voltage control signals with high-power industrial loads\u003c\/strong\u003e. It provides reliable switching capability for automation systems, ensuring stable signal isolation and dependable operation in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eWith a compact design and robust contact rating, the module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC and DC loads\u003c\/strong\u003e, making it suitable for applications such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem interlocks, status signaling, and load control\u003c\/strong\u003e. Its construction ensures durability and consistent performance in continuous automation processes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670CHS101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControl Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e10 A per contact (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 MΩ at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC (1 minute, coil to contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35 mm × 22 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density control panels\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrical isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween control and load circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC and DC switching applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDurable construction for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial automation environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC670CHS101 handle inductive loads?\u003c\/strong\u003e\u003cbr\u003eYes, but when switching\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehighly inductive loads\u003c\/strong\u003e, suppression devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflyback diodes or RC snubbers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare recommended to protect relay contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module installed?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670CHS101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to integrate directly into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Field Control block system\u003c\/strong\u003e, allowing installation alongside other Field Control I\/O modules.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746734747900,"sku":"IC670CHS101","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670CHS101.jpg?v=1773126953"},{"product_id":"ge-fanuc-ic670alg240-16-channel-analog-input-module","title":"GE Fanuc IC670ALG240 16-Channel Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog input module for the GE Fanuc Field Control architecture. It mounts directly on a Bus Interface Unit (BIU) or expansion base and provides 16 independent, isolated current input channels for precise process measurement.\u003c\/p\u003e\n\u003cp\u003eEach channel features a dedicated 16-bit ADC, converting low-level field signals into high-resolution digital data with minimal noise, enabling reliable data acquisition in complex industrial control loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC670ALG240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Series\u003c\/td\u003e\n\u003ctd\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 isolated current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Compatibility\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, 0–20 mA, 0–25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e251 mA maximum from BIU backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e20–28 VDC nominal loop power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Stability\u003c\/td\u003e\n\u003ctd\u003e±0.002%\/°C typical, ±0.005%\/°C maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Support\u003c\/td\u003e\n\u003ctd\u003eANSI Type 2 (2-wire) and Type 3 (3-wire) transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003ePrecision burden resistor for loop stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 55°C (32°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eAdvanced Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe IC670ALG240 includes robust internal self-checks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitors A\/D conversion health and calibration validity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetects underrange\/overrange conditions per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlerts for individual channel high\/low alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures early detection of sensor failure or line breaks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese features help maintain system uptime and ensure high-quality, reliable data for control and safety systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess monitoring of flow meters, pressure transmitters, and liquid level sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBridging signals from VFDs or single-loop controllers to central control logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration of analytical instrumentation such as turbidity or chemical sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-precision industrial monitoring loops requiring current-based inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support voltage inputs?\u003c\/strong\u003e\u003cbr\u003eNo. The IC670ALG240 is optimized for current inputs. Voltage measurement requires a separate voltage input module from the IC670 series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs calibration required upon installation?\u003c\/strong\u003e\u003cbr\u003eThe module is factory-calibrated. Internal diagnostics continuously monitor calibration status and will alert the operator if data is missing or out of range, ensuring consistent, reliable measurement.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746736025852,"sku":"IC670ALG240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670ALG240-CB2.jpg?v=1770948453"},{"product_id":"ge-fanuc-ic670alg230-field-control-analog-input-module","title":"GE Fanuc IC670ALG230 Field Control Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module from the GE Fanuc Field Control series. It provides eight single-ended channels for current input, optimized for 0–20 mA or 4–20 mA signals.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 12-bit high-speed ADC, the IC670ALG230 delivers rapid conversion (60 μs per channel) with minimal non-linearity (±0.025%). Galvanic isolation protects logic-side electronics from field-side surges, making it ideal for precision process monitoring in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003eIC670ALG230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Architecture\u003c\/td\u003e\n\u003ctd\u003eField Control (BIU \/ Expansion Rack compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA (configurable for 4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (≈5 μA per bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Rate\u003c\/td\u003e\n\u003ctd\u003e60 μs per channel (1 MHz system clock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for distributed control systems requiring precise, high-speed analog monitoring of field devices such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlow meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-frequency process loops in chemical or manufacturing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts fast ADC conversion allows real-time data acquisition and accurate process control.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle wire breaks?\u003c\/strong\u003e\u003cbr\u003eIt includes built-in diagnostics optimized to detect open-wire conditions in 4–20 mA loops, triggering immediate fail-safe alerts to protect process integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module measure voltage directly?\u003c\/strong\u003e\u003cbr\u003eThe module is primarily optimized for current inputs. Voltage measurement may require external shunts or a different IC670 variant designed for voltage ranges.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746736222460,"sku":"IC670ALG230","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670ALG230.jpg?v=1770948453"},{"product_id":"ge-multilin-469-p5-hi-a20-t-h-motor-management-relay","title":"GE Multilin 469-P5-HI-A20-T-H Motor Management Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a microprocessor-based motor protection and management relay from the Multilin 469 series. It is designed for medium to large horsepower motors, providing comprehensive electrical and mechanical fault protection, advanced thermal modeling, and integrated diagnostics.\u003c\/p\u003e\n\u003cp\u003eThis configuration supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5A CT inputs\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-voltage control power\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour programmable 4–20 mA outputs\u003c\/strong\u003e, making it suitable for high-voltage industrial control systems and SCADA integration. The conformal coating option ensures reliable operation in harsh environments with humidity or corrosive gases.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e469-P5-HI-A20-T-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMultilin 469 Motor Management System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input (P5)\u003c\/td\u003e\n\u003ctd\u003e5 A Phase CT Secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power (HI)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC \/ 70–265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs (A20)\u003c\/td\u003e\n\u003ctd\u003e4 × isolated 4–20 mA (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option (T)\u003c\/td\u003e\n\u003ctd\u003eConformal coating (harsh environment protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting (H)\u003c\/td\u003e\n\u003ctd\u003eHorizontal chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 × RS232 (front), 2 × RS485 (rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU (up to 19.2 kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e12 × 100 Ω Platinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Functions\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, kW, kVAR, kVA, Energy, Demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H×W×D)\u003c\/td\u003e\n\u003ctd\u003e223.5 × 216.4 × 252.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThree-phase induction and synchronous motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-inertia loads requiring acceleration protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVFD-driven motor monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePumps, compressors, and fans in power, oil \u0026amp; gas, and heavy industry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the “T” option indicate?\u003c\/strong\u003e\u003cbr\u003eIt denotes conformal-coated internal PCBs for protection against moisture, chemicals, and H₂S exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with 1A CTs?\u003c\/strong\u003e\u003cbr\u003eNo. The P5 variant is calibrated strictly for 5A CT secondaries. A 1A model variant is required for 1A CT systems.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746769383676,"sku":"469-P5-HI-A20","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/469-P5-HI-A20-T-H.jpg?v=1772092232"},{"product_id":"ge-fanuc-vmivme-7750-single-board-computer","title":"GE Fanuc VMIVME-7750 Single Board Computer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVMIVME-7750\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance 6U VMEbus single board computer (SBC) developed by Abaco Systems (formerly GE Fanuc).\u003c\/p\u003e\n\u003cp\u003ePowered by the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntel Pentium III\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessor architecture, this SBC provides deterministic real-time computing for legacy embedded control systems. It is widely used as a processing core in aerospace, defense, and industrial automation platforms, including modernization projects for turbine control systems.\u003c\/p\u003e\n\u003cp\u003eThe board integrates dual Ethernet ports, VGA graphics output, and serial communication interfaces, reducing the need for external expansion hardware. ECC memory support and industrial-grade thermal design improve reliability in vibration-prone and temperature-variable environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVMIVME-7750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Pentium III (733–933 MHz typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL2 Cache\u003c\/td\u003e\n\u003ctd\u003e256 KB \/ 512 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eUp to 512 MB SDRAM (ECC protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eCompactFlash Type II + IDE support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork\u003c\/td\u003e\n\u003ctd\u003eDual 10\/100 Mbps Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraphics\u003c\/td\u003e\n\u003ctd\u003eAGP SVGA (up to 1600 × 1200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOS Support\u003c\/td\u003e\n\u003ctd\u003eWindows NT\/2000, Linux, VxWorks, QNX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +55°C (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine control system modernization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAerospace and defense simulation platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRadar and imaging data processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial MRO legacy system maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eParticularly useful in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability deterministic control environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere legacy VME architectures remain in operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does it support modern operating systems?\u003c\/strong\u003e\u003cbr\u003eYes. It supports legacy Windows NT\/2000\/XP, Linux distributions, and RTOS environments such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVxWorks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand QNX, with proper VMEbus driver support.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the RAM be upgraded?\u003c\/strong\u003e\u003cbr\u003eYes, but memory must meet manufacturer timing and voltage specifications to ensure system stability. Memory is typically installed via ECC-enabled SODIMM modules.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746786717948,"sku":"VMIVME-7750","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/VMIVME-7750-734.jpg?v=1771917984"},{"product_id":"ge-fanuc-vmivme-7768-cpu-board","title":"GE Fanuc VMIVME-7768 CPU Board","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVMIVME-7768\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 6U VMEbus single-board computer (SBC) developed by Abaco Systems (formerly GE Fanuc).\u003c\/p\u003e\n\u003cp\u003ePowered by an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntel Pentium III processor\u003c\/strong\u003e, this SBC serves as a high-reliability control and processing node for legacy embedded and industrial control systems. It provides integrated networking, graphics, and serial communication interfaces, making it suitable for real-time automation, simulation, and control applications.\u003c\/p\u003e\n\u003cp\u003eThe board supports multiple real-time operating systems and includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePMC expansion slots\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor modular I\/O and functional extension without consuming additional VME chassis slots.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVMIVME-7768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eVMEbus 6U Single Slot SBC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003eIntel Pentium III (up to 1.26 GHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003eUp to 1 GB SDRAM (ECC protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage\u003c\/td\u003e\n\u003ctd\u003eOnboard IDE-compatible Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork\u003c\/td\u003e\n\u003ctd\u003eDual 10\/100 Mbps Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGraphics\u003c\/td\u003e\n\u003ctd\u003eIntegrated AGP VGA controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAerospace and flight simulation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDefense radar and mission computing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower plant monitoring and legacy turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial MRO upgrades for legacy DCS architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eParticularly valuable in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability real-time control environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring deterministic processing performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How are serial communication standards configured?\u003c\/strong\u003e\u003cbr\u003eSerial ports are\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ejumper-configurable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto support RS-232, RS-422, or RS-485 depending on field device requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does it support hot-swapping?\u003c\/strong\u003e\u003cbr\u003eNo. VMEbus standards do not natively support hot-swapping. The system power must be fully disconnected before installing or removing the board to prevent hardware damage.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746787307772,"sku":"VMIVME-7768","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/VMIVME-7768.jpg?v=1771917984"},{"product_id":"735-5-5-hi-485-ge-multilin-feeder-protection-relay","title":"735-5-5-HI-485 GE Multilin Feeder Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision feeder protection relay from the GE Multilin family. It is designed for the protection and monitoring of electrical distribution feeders in industrial and utility power systems.\u003c\/p\u003e\n\u003cp\u003eThis microprocessor-based relay combines instantaneous and time-delayed overcurrent protection with ground fault detection, ensuring reliable feeder protection and system stability. Although now discontinued, it remains an essential component for maintaining legacy switchgear and power monitoring infrastructures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e735-5-5-HI-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Protection\u003c\/td\u003e\n\u003ctd\u003e50\/51 Phase Overcurrent (Instantaneous and Time Delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Protection\u003c\/td\u003e\n\u003ctd\u003e50G\/51G Ground Fault (Instantaneous and Time Delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply (HI)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC or 70–265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485 2-wire serial port (SCADA integration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eDigital setpoint adjustment for trip curves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eTrue RMS current sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eDraw-out or fixed-mount relay housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUtility substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge industrial power distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofitted switchgear requiring RS485 SCADA integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFacilities with varying DC battery or AC auxiliary power sources\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt protects feeder circuits against short circuits, overloads, and ground faults while supporting remote monitoring and fault analysis.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 735-5-5-HI-485 still in production?\u003c\/strong\u003e\u003cbr\u003eNo. The model is discontinued by the manufacturer but remains available as refurbished or surplus units to support legacy installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does “5-5” indicate in the model number?\u003c\/strong\u003e\u003cbr\u003eThe “5-5” designation signifies compatibility with 5 A Phase and 5 A Ground current transformer secondary inputs, ensuring standard CT integration for feeder protection.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746788356348,"sku":"735-5-5-HI-485","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/735-5-5-HI-485.jpg?v=1770948453"},{"product_id":"ic200alg322d-ge-fanuc-plc-analog-output-module","title":"IC200ALG322D GE Fanuc PLC Analog Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322D (IC200ALG322)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision 4-channel analog output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eGE Fanuc\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. Designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial process control\u003c\/strong\u003e, it provides 4 to 20 mA current loop outputs to drive actuators, valves, and VFDs. The \"D\" revision enhances thermal performance and component longevity while remaining fully compatible with previous IC200ALG322 modules.\u003c\/p\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-bit resolution\u003c\/strong\u003e, the IC200ALG322D ensures smooth and granular control over process variables. Each channel includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen-wire detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand loop power monitoring for proactive fault diagnostics. Its compact footprint allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density installation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon standard VersaMax carriers, while the module draws internal logic power from the backplane and requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexternal 24V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor output loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200ALG322D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent Loop (4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (1 part in 4000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e0–850 Ω (at 24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e24V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Draw\u003c\/td\u003e\n\u003ctd\u003e50 mA (from 5V backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e4 ms (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLoop power and open-wire detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC (field vs logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F – 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Loop Management\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount on an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS series carrier\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshielded twisted-pair cabling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain 12-bit precision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED indicator signals normal operation (green) or alerts (amber\/off) for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eloss of 24V field power or hardware faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC200ALG322D support voltage outputs (0–10V)?\u003c\/strong\u003e\u003cbr\u003eNo. This module is strictly a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA current output\u003c\/strong\u003e. Voltage output requires a different module (e.g., IC200ALG321) or an external 500 Ω resistor for current-to-voltage conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a field wire is broken?\u003c\/strong\u003e\u003cbr\u003eThe module detects\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen-wire conditions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand reports a \"Low Scale\" or \"Open Wire\" fault to the CPU, enabling immediate maintenance intervention.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746790289660,"sku":"IC200ALG322D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG322D1.jpg?v=1771055433"},{"product_id":"ic200chs001-ge-fanuc-versamax-barrier-style-i-o-carrier","title":"IC200CHS001 GE Fanuc VersaMax Barrier-Style I\/O Carrier","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS001 (IC200-CHS-001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebarrier-style wiring base\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the GE Fanuc\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax I\/O platform\u003c\/strong\u003e. It provides a rugged mechanical and electrical interface between field devices and I\/O modules, featuring an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen barrier-strip design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor easy access to termination points. The carrier supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping of modules\u003c\/strong\u003e, integrated mechanical keying to prevent incorrect installation, and accommodates both AC and DC signals, making it suitable for demanding industrial environments with high vibration or heavy-duty wiring requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200CHS001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBarrier-Style Screw Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e0–264 VAC (Operational)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Protection\u003c\/td\u003e\n\u003ctd\u003eUp to 300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per signal point \/ 8 A per power\/ground terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity\u003c\/td\u003e\n\u003ctd\u003e1–2 wires per terminal (must be same type\/size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Requirement\u003c\/td\u003e\n\u003ctd\u003eCopper, rated ≥ 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Torque\u003c\/td\u003e\n\u003ctd\u003e0.37–0.50 ft-lbs (0.5–0.68 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Mechanism\u003c\/td\u003e\n\u003ctd\u003eAdjustable rotary dials for module-to-carrier matching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail or panel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eWiring and Installation Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse high-quality copper conductors; two wires in a terminal must be identical in type and size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBarrier strips provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephysical separation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween terminals, reducing risk of shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor panel mounting, ensure a proper ground path through the backplane and carrier frame for EMI and transient protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between IC200CHS001 and IC200CHS002?\u003c\/strong\u003e\u003cbr\u003eThe IC200CHS001 uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebarrier-style exposed screw terminal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuitable for ring or spade lugs and high-vibration environments. The IC200CHS002 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebox-style\u003c\/strong\u003e, using cage terminals for wire insertion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this carrier be mounted on a non-conductive surface?\u003c\/strong\u003e\u003cbr\u003eYes, it can be panel-mounted, but ensure proper grounding through the backplane and carrier frame to maintain EMI shielding and transient protection.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746790715644,"sku":"IC200CHS001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200CHS0011.jpg?v=1771055433"},{"product_id":"ic200chs002-ge-fanuc-plc-i-o-carrier-module","title":"IC200CHS002 GE Fanuc PLC I\/O Carrier Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS002 (IC200-CHS-002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emounting and wiring carrier\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Emerson\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax I\/O system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(formerly GE Fanuc). It provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebox-style terminal base\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat hosts I\/O modules, enabling a modular and hot-swappable architecture. By separating the wiring from the electronics, it allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodule replacement and troubleshooting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout disturbing field wiring, reducing system downtime.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-density installations, the IC200CHS002 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to 32-point I\/O modules\u003c\/strong\u003e. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e36 screw terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein two organized strips, integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ekeying dials\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent incorrect module insertion, a rugged backplane connector, and a secure latching mechanism for vibration-resistant mounting.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200CHS002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBox-style screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Terminals\u003c\/td\u003e\n\u003ctd\u003e36 (Two strips: A1–A18, B1–B18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e264 VAC (Operational) \/ 300 VAC (Transient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\/Common Capacity\u003c\/td\u003e\n\u003ctd\u003e8 A per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Compatibility\u003c\/td\u003e\n\u003ctd\u003e16-point and 32-point VersaMax I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying\u003c\/td\u003e\n\u003ctd\u003eManual rotary dials for hardware coding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Field Wiring\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAdhere to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etorque specifications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor secure, gas-tight connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower\/common terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated at 8 A allow efficient distribution without external blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density analog and discrete modules\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200CHS002 be used with high-density analog modules?\u003c\/strong\u003e\u003cbr\u003eYes, its 36-terminal configuration supports 32-point discrete modules and multi-channel analog modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the keying dials?\u003c\/strong\u003e\u003cbr\u003eKeying dials prevent incorrect module insertion. By setting them to coordinates specified in the module manual, only the correct module type can be fully seated, protecting the system from electrical mismatches (e.g., 24V DC vs. 120V AC modules).\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746790977788,"sku":"IC200CHS002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200CHS002.jpg?v=1771055433"},{"product_id":"ge-fanuc-versamax-ic200chs022-compact-i-o-terminal-carrier","title":"GE Fanuc VersaMax IC200CHS022 Compact I\/O Terminal Carrier","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS022\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, high-density I\/O carrier from the GE Fanuc VersaMax family. It provides a secure mechanical and electrical foundation for VersaMax I\/O modules while integrating field wiring termination with the backplane communication interface.\u003c\/p\u003e\n\u003cp\u003eDesigned for modular, “hot-swappable” operation, the local box-style wiring allows field connections to remain intact even when I\/O modules are removed, reducing downtime during maintenance or system upgrades.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200CHS022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax Compact I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC (via backplane\/power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Style\u003c\/td\u003e\n\u003ctd\u003eLocal box with integrated screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection Type\u003c\/td\u003e\n\u003ctd\u003eIntegrated terminal block for direct wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eAll standard VersaMax I\/O and NIU modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Retention\u003c\/td\u003e\n\u003ctd\u003eSecure locking mechanism for module stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Interface\u003c\/td\u003e\n\u003ctd\u003eHigh-density backplane connector for logic communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS022\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for distributed control environments with limited cabinet space, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRemote I\/O stations in water and wastewater treatment plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC and building automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated assembly lines and compact manufacturing cells\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts local box wiring allows pre-wiring of cabinets, accelerating commissioning and minimizing operational downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this carrier include the power supply?\u003c\/strong\u003e\u003cbr\u003eNo. The IC200CHS022 is a passive wiring and mounting base. Power is supplied through the carrier from a VersaMax Power Supply module installed on the left side of the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an I\/O module without disconnecting the wires?\u003c\/strong\u003e\u003cbr\u003eYes. Field wiring is terminated directly to the carrier, allowing I\/O modules to be snapped on or off without disturbing the electrical connections, supporting true hot-swappable operation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746791108860,"sku":"IC200CHS022","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200CHS0221.jpg?v=1770948452"},{"product_id":"is200staih2acb-ge-fanuc-compact-analog-input-board","title":"IS200STAIH2ACB GE Fanuc Compact Analog Input Board","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200STAIH2ACB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, high-density analog input terminal board designed for the GE Mark VI and Mark VIe control platforms. It serves as the interface layer between field analog devices and the turbine control processor, enabling reliable acquisition of process signals in space-constrained control cabinets.\u003c\/p\u003e\n\u003cp\u003eThis board supports 10 analog input channels and includes two configurable current output channels. An integrated on-board ID chip allows the controller to automatically recognize the board revision and configuration, simplifying commissioning, asset tracking, and maintenance diagnostics.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Designation\u003c\/td\u003e\n\u003ctd\u003eIS200STAIH2ACB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Platform\u003c\/td\u003e\n\u003ctd\u003eMark VI \/ Mark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e10 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Support\u003c\/td\u003e\n\u003ctd\u003e2-wire, 3-wire, and 4-wire transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e2 total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eStandard 0–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Current Output\u003c\/td\u003e\n\u003ctd\u003eOne channel configurable up to 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eEuro-block pluggable terminal strips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eSurface Mount Technology (SMT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Features\u003c\/td\u003e\n\u003ctd\u003eIntegrated protection diodes \u0026amp; precision components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eJumper-selectable ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eIntegrated Silicon ID chip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–30°C to +65°C (–22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.9 cm × 10.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Interface\u003c\/td\u003e\n\u003ctd\u003e24 heavy-duty metal terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS200STAIH2ACB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in power generation environments, particularly within:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombined-cycle power plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is commonly used for interfacing:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlow meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuxiliary analog instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts compact footprint and high channel density make it ideal for retrofit cabinets and high-speed turbine control applications where space optimization is critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the output channel drive high-current actuators?\u003c\/strong\u003e\u003cbr\u003eYes. While both outputs support standard 0–20 mA signaling, one channel can be configured to deliver up to 200 mA for specialized instrumentation or actuator requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board compatible with redundant systems?\u003c\/strong\u003e\u003cbr\u003eThe IS200STAIH2ACB is designed for simplex operation. For TMR (Triple Modular Redundant) architectures, verify that the overall system configuration supports integration of simplex terminal boards within a redundant framework.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746791174396,"sku":"IS200STAIH2ACB","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IS200STAIH2ACB1.jpg?v=1770948453"},{"product_id":"ge-fanuc-ic693apu300-series-90-30-high-speed-counter-module","title":"GE Fanuc IC693APU300 Series 90-30 High-Speed Counter Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693APU300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed counter (HSC) module designed for the Series 90-30 PLC ecosystem (originally GE Fanuc). It provides a high-performance interface between rapid pulse-generating field devices and the PLC processor, ensuring precise real-time tracking of position, velocity, and totalization events.\u003c\/p\u003e\n\u003cp\u003eThis module converts raw pulse inputs into actionable digital data, allowing high-speed mechanical or flow events to be captured without loss, even beyond the capabilities of standard I\/O scan cycles.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC693APU300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eHigh-Speed Counter (HSC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Counting Rate\u003c\/td\u003e\n\u003ctd\u003e200 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e12 positive logic inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC693APU300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly used in applications requiring high-speed pulse acquisition, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMotion Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracking motor shaft position and travel using optical encoders\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFlow Metering:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSignal processing from turbine or positive displacement flowmeters for accurate totalization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCounting items on high-speed conveyors for sorting or inventory\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRotational Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCapturing turbine speeds or other critical rotational velocities with magnetic pickups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be used in a Remote I\/O rack?\u003c\/strong\u003e\u003cbr\u003eYes. It is compatible with both local and expansion baseplates within the Series 90-30 architecture that support option modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support both 5V and 24V encoders?\u003c\/strong\u003e\u003cbr\u003eYes. The IC693APU300 accepts 5 V TTL encoder signals as well as 10–30 V industrial proximity sensors and encoders, eliminating the need for external level-shifting hardware.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746791338236,"sku":"DS200TCPSG1ARE","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC693APU300.jpg?v=1770948453"},{"product_id":"ic660bbd021-ge-fanuc-genius-discrete-i-o-block","title":"IC660BBD021 GE Fanuc Genius Discrete I\/O Block","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC660BBD021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance, 16-point configurable discrete I\/O block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGenius I\/O distributed network\u003c\/strong\u003e. Each channel can be independently configured as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einput or output\u003c\/strong\u003e, supporting both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC and 48 VDC systems\u003c\/strong\u003e. It is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esink-type block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith robust diagnostics, enabling decentralized, high-speed control. Its reliability and advanced fault detection make it a core component in legacy PLC applications across\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emanufacturing, automotive, and water treatment industries\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660BBD021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eGenius I\/O (Legacy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Circuits\u003c\/td\u003e\n\u003ctd\u003e16 configurable discrete circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Type\u003c\/td\u003e\n\u003ctd\u003eSink (path to ground for load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Processing Time\u003c\/td\u003e\n\u003ctd\u003e1.7 ms (high-speed digital scan)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e2 A per circuit (peak inrush 10 A for 10 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V block-to-block \u0026amp; system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eGenius Bus (frequency selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA typical, 300 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Dropout Tolerance\u003c\/td\u003e\n\u003ctd\u003eUp to 10 ms without loss of operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e224.4 × 88.9 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.49 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfigurable I\/O:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 16 channels can be individually set as input or output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors open circuits, switch failures, and over-temperature events at the individual channel level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-Volatile Memory:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePreserves configuration settings during power loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Scanning:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for fast automation cycles and real-time control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with modern RX3i controllers via a Genius Bus Controller (GBC), enabling gradual system upgrades.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the IC660BBD021 configured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUsing a Genius Hand-Held Monitor (HHM) or PLC software (e.g., Proficy Machine Edition). Each point can be set as input or output with diagnostic thresholds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSink vs. Source blocks – what’s the difference?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSink block\u003c\/strong\u003e, the module provides the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epath to ground\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the load. It is compatible with field devices that source positive voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with modern RX3i controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eYes, with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGenius Bus Controller\u003c\/strong\u003e, allowing legacy I\/O to integrate into RX3i systems, supporting a cost-effective migration path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746805559548,"sku":"IC660BBD021","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC660BBD021.jpg?v=1770790227"}],"url":"https:\/\/www.electronicplc.com\/collections\/ge-fanuc.oembed?page=3","provider":"Electronic PLC","version":"1.0","type":"link"}