{"title":"GE Field Control","description":"\u003cp\u003eGE Field Control components were designed to bring I\/O closer to the field devices, reducing wiring costs and improving signal integrity. This category features the I\/O modules and Bus Interface Units (BIUs) required to maintain these distributed field stations. While many of these components are now considered legacy, they remain vital for specific industrial installations that rely on their modular, decentralized architecture. We offer verified Field Control hardware to help you sustain these localized control nodes, ensuring continuous communication between field instruments and the central control processor.\u003c\/p\u003e","products":[{"product_id":"ge-fanuc-ic670gbi002-field-control-genius-bus-interface-unit","title":"GE Fanuc IC670GBI002 Field Control Genius Bus Interface Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670GBI002\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary Bus Interface Unit (BIU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Field Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. It enables high-speed communication between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield I\/O modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaster controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGenius Bus protocol\u003c\/strong\u003e. Supporting up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 field modules\u003c\/strong\u003e, it handles\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e128 bytes of input and output data per cycle\u003c\/strong\u003e, serving as a reliable bridge for industrial automation networks.\u003c\/p\u003e\n\u003cp\u003eThe unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDIN-rail mountable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor secure installation and operates on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24V DC nominal power\u003c\/strong\u003e, with integrated 6.5V DC backplane supply for connected modules. With a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMean Time Before Failure (MTBF) of 183,000 hours\u003c\/strong\u003e, it is engineered for long-term reliability in critical control systems, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swappable modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor minimal maintenance downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670GBI002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 Field I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Capacity\u003c\/td\u003e\n\u003ctd\u003e128 Bytes Input \/ 128 Bytes Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.68 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLong MTBF for continuous operation in critical applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports module insertion\/removal without full system shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDeterministic Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOptimized for Genius Bus integration between master controller and I\/O modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDedicated terminal strips for power, communication, and module connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC670GBI002 require a specific DIN rail for grounding?\u003c\/strong\u003e\u003cbr\u003eYes. Use a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-conductivity, corrosion-resistant DIN rail\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure stable low-impedance grounding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I hot-swap I\/O modules while the BIU is powered?\u003c\/strong\u003e\u003cbr\u003eYes. Hot insertion and removal are supported\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eif the installed I\/O modules are compatible\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith hot-swap operations.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746734420220,"sku":"IC670GBI002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670GBI002.jpg?v=1773126954"},{"product_id":"ge-ic670mdl640-field-control-discrete-input-module","title":"GE IC670MDL640 Field Control Discrete Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670MDL640\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel discrete input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Field Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. Designed to integrate with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBus Interface Unit (BIU)\u003c\/strong\u003e, it provides reliable digital input monitoring for industrial automation systems. The module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epositive and negative logic\u003c\/strong\u003e, making it compatible with diverse control architectures and regional wiring standards.\u003c\/p\u003e\n\u003cp\u003eOptimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24V DC systems\u003c\/strong\u003e, the IC670MDL640 accepts input voltages from 0–30V DC. Its robust design, low input impedance, and fast response times ensure accurate detection of field device state changes, while drawing power directly from the BIU for simplified cabinet wiring and efficient high-density I\/O deployment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Discrete Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0–30V DC (Nominal 24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Logic\u003c\/td\u003e\n\u003ctd\u003ePositive and Negative Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e+15V to +30V DC (Positive), -15V to -30V DC (Negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0–5V DC (Positive), 0 to -5V DC (Negative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.23 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Logic Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompatible with positive and negative logic wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast, Deterministic Inputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eReliable response for high-speed control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMounts adjacent to the BIU for organized, space-efficient panel layouts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBus-Powered:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDraws power directly from the BIU, eliminating the need for an external supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC670MDL640 handle 30V DC sensors?\u003c\/strong\u003e\u003cbr\u003eYes, the module accepts inputs up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30V DC\u003c\/strong\u003e, making it suitable for standard industrial sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require a separate power supply?\u003c\/strong\u003e\u003cbr\u003eNo. It\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edraws all necessary current from the BIU\u003c\/strong\u003e, simplifying wiring and reducing external components.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746734584060,"sku":"IC670MDL640","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670MDL640.jpg?v=1773126953"},{"product_id":"ge-fanuc-ic670chs101-control-relay-module-for-field-control","title":"GE Fanuc IC670CHS101 Control Relay Module for Field Control","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670CHS101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a control relay module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Field Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries, designed to interface\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow-voltage control signals with high-power industrial loads\u003c\/strong\u003e. It provides reliable switching capability for automation systems, ensuring stable signal isolation and dependable operation in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eWith a compact design and robust contact rating, the module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC and DC loads\u003c\/strong\u003e, making it suitable for applications such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem interlocks, status signaling, and load control\u003c\/strong\u003e. Its construction ensures durability and consistent performance in continuous automation processes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670CHS101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eControl Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e10 A per contact (AC\/DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;100 MΩ at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e1500 V AC (1 minute, coil to contacts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35 mm × 22 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompact design for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density control panels\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrical isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween control and load circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC and DC switching applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDurable construction for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial automation environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC670CHS101 handle inductive loads?\u003c\/strong\u003e\u003cbr\u003eYes, but when switching\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehighly inductive loads\u003c\/strong\u003e, suppression devices such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflyback diodes or RC snubbers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare recommended to protect relay contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module installed?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670CHS101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to integrate directly into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc Field Control block system\u003c\/strong\u003e, allowing installation alongside other Field Control I\/O modules.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746734747900,"sku":"IC670CHS101","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670CHS101.jpg?v=1773126953"},{"product_id":"ge-field-control-ic670alg620-rtd-analog-input-module","title":"GE Field Control IC670ALG620 RTD Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG620\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog input module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Field Control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eproduct family, specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperature monitoring using RTD sensors\u003c\/strong\u003e. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to four independent RTD inputs\u003c\/strong\u003e, enabling accurate thermal measurement across multiple process points in industrial automation systems.\u003c\/p\u003e\n\u003cp\u003eIt is compatible with both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3-wire and 4-wire RTD configurations\u003c\/strong\u003e, supporting a wide range of resistance temperature detectors including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eplatinum, nickel, nickel-iron, and copper elements\u003c\/strong\u003e. This flexibility allows the module to integrate seamlessly with various industrial temperature sensing standards.\u003c\/p\u003e\n\u003cp\u003eBuilt for demanding environments, the IC670ALG620 performs\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time analog-to-digital conversion\u003c\/strong\u003e, delivering precise temperature or raw resistance data directly to the control system. The module also integrates advanced diagnostics such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic recalibration during power-up\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand continuous monitoring for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen circuits, short circuits, and out-of-range signal conditions\u003c\/strong\u003e. Additionally, the module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal excitation current\u003c\/strong\u003e, eliminating the need for external loop power supplies and simplifying field wiring.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC670ALG620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Density\u003c\/td\u003e\n\u003ctd\u003e4 Independent RTD Input Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003e3-wire and 4-wire RTDs (Platinum, Nickel, Ni-Fe, Copper)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Ranges\u003c\/td\u003e\n\u003ctd\u003e0–500 Ω; 0–3000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eConfigurable (Ohms, °C, °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency Rejection\u003c\/td\u003e\n\u003ctd\u003eSelectable 50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Current\u003c\/td\u003e\n\u003ctd\u003eInternal module-supplied\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG620\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emaintains measurement accuracy through continuous hardware diagnostics and calibration processes. During startup, the module automatically performs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eself-calibration routine\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto compensate for environmental variations and maintain long-term measurement stability.\u003c\/p\u003e\n\u003cp\u003eThe module continuously monitors signal integrity and will\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eimmediately report alarm conditions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eif input values exceed predefined thresholds. Diagnostic capabilities detect\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen circuits, short circuits, and signal range violations\u003c\/strong\u003e, allowing maintenance teams to quickly identify sensor or wiring issues.\u003c\/p\u003e\n\u003cp\u003eIts\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodular Field Control architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows high-density installations and straightforward system expansion, making it well suited for distributed I\/O applications in large-scale industrial control systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC670ALG620 require external resistors for RTD excitation?\u003c\/strong\u003e\u003cbr\u003eNo. The module provides the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexcitation current internally\u003c\/strong\u003e, allowing direct connection of both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3-wire and 4-wire RTD sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout additional external components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module switch between temperature and resistance measurements?\u003c\/strong\u003e\u003cbr\u003eYes. Each input channel can be\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindividually configured\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto output measurement data either as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eraw resistance (ohms)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecalculated temperature values (°C or °F)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edepending on the application requirements.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746735632636,"sku":"IC670ALG620","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670ALG6202.jpg?v=1773126954"},{"product_id":"ge-fanuc-ic670alg240-16-channel-analog-input-module","title":"GE Fanuc IC670ALG240 16-Channel Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog input module for the GE Fanuc Field Control architecture. It mounts directly on a Bus Interface Unit (BIU) or expansion base and provides 16 independent, isolated current input channels for precise process measurement.\u003c\/p\u003e\n\u003cp\u003eEach channel features a dedicated 16-bit ADC, converting low-level field signals into high-resolution digital data with minimal noise, enabling reliable data acquisition in complex industrial control loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC670ALG240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Series\u003c\/td\u003e\n\u003ctd\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e16 isolated current inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Compatibility\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, 0–20 mA, 0–25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e251 mA maximum from BIU backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e20–28 VDC nominal loop power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Stability\u003c\/td\u003e\n\u003ctd\u003e±0.002%\/°C typical, ±0.005%\/°C maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Support\u003c\/td\u003e\n\u003ctd\u003eANSI Type 2 (2-wire) and Type 3 (3-wire) transmitters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003ePrecision burden resistor for loop stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 55°C (32°F to 131°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eAdvanced Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe IC670ALG240 includes robust internal self-checks:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitors A\/D conversion health and calibration validity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetects underrange\/overrange conditions per channel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlerts for individual channel high\/low alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsures early detection of sensor failure or line breaks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese features help maintain system uptime and ensure high-quality, reliable data for control and safety systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcess monitoring of flow meters, pressure transmitters, and liquid level sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBridging signals from VFDs or single-loop controllers to central control logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration of analytical instrumentation such as turbidity or chemical sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-precision industrial monitoring loops requiring current-based inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support voltage inputs?\u003c\/strong\u003e\u003cbr\u003eNo. The IC670ALG240 is optimized for current inputs. Voltage measurement requires a separate voltage input module from the IC670 series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs calibration required upon installation?\u003c\/strong\u003e\u003cbr\u003eThe module is factory-calibrated. Internal diagnostics continuously monitor calibration status and will alert the operator if data is missing or out of range, ensuring consistent, reliable measurement.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746736025852,"sku":"IC670ALG240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670ALG240-CB2.jpg?v=1770948453"},{"product_id":"ge-fanuc-ic670alg230-field-control-analog-input-module","title":"GE Fanuc IC670ALG230 Field Control Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module from the GE Fanuc Field Control series. It provides eight single-ended channels for current input, optimized for 0–20 mA or 4–20 mA signals.\u003c\/p\u003e\n\u003cp\u003eFeaturing a 12-bit high-speed ADC, the IC670ALG230 delivers rapid conversion (60 μs per channel) with minimal non-linearity (±0.025%). Galvanic isolation protects logic-side electronics from field-side surges, making it ideal for precision process monitoring in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003eIC670ALG230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Architecture\u003c\/td\u003e\n\u003ctd\u003eField Control (BIU \/ Expansion Rack compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0–20 mA (configurable for 4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eADC Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (≈5 μA per bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Rate\u003c\/td\u003e\n\u003ctd\u003e60 μs per channel (1 MHz system clock)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for distributed control systems requiring precise, high-speed analog monitoring of field devices such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlow meters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-frequency process loops in chemical or manufacturing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts fast ADC conversion allows real-time data acquisition and accurate process control.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle wire breaks?\u003c\/strong\u003e\u003cbr\u003eIt includes built-in diagnostics optimized to detect open-wire conditions in 4–20 mA loops, triggering immediate fail-safe alerts to protect process integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module measure voltage directly?\u003c\/strong\u003e\u003cbr\u003eThe module is primarily optimized for current inputs. Voltage measurement may require external shunts or a different IC670 variant designed for voltage ranges.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746736222460,"sku":"IC670ALG230","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC670ALG230.jpg?v=1770948453"},{"product_id":"ic670pbi001-ge-fanuc-profibus-bus-interface-unit","title":"GE Fanuc IC670PBI001-BE Profibus Bus Interface Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe IC670PBI001-BE is a high-performance Profibus Bus Interface Unit (BIU) designed for the GE Fanuc Field Control system. This module functions as a communication gateway, bridging the Profibus-DP network with localized Field Control I\/O modules to enable decentralized control and efficient data exchange. Housed in a durable aluminum enclosure, it is suitable for demanding industrial environments, including power generation, oil and gas, and mining facilities. The unit supports advanced field-level processing, such as analog scaling and automated fault reporting, to reduce system downtime and streamline diagnostics.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports Profibus-DP communication protocol for seamless network integration.\u003c\/li\u003e\n\u003cli\u003eIntegrated intelligent processing for independent analog range selection and I\/O configuration.\u003c\/li\u003e\n\u003cli\u003eFront-mounted HHP connector for local configuration and rapid troubleshooting.\u003c\/li\u003e\n\u003cli\u003eDiagnostic LED indicators (PWR, OK, RUN) for real-time status monitoring.\u003c\/li\u003e\n\u003cli\u003eRugged aluminum housing designed for space-constrained control panels and junction boxes.\u003c\/li\u003e\n\u003cli\u003eSupports both single and dual cable communication configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThis interface unit is typically deployed in distributed I\/O architectures where remote data acquisition and control are required. It is commonly used in process automation, manufacturing, and utility infrastructure to connect field sensors and actuators to a centralized Profibus-DP master controller.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670PBI001-BE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eProfibus Bus Interface Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Protection\u003c\/td\u003e\n\u003ctd\u003e1 Amp replaceable slow-blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eProfibus-DP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the unit in a clean, dry environment within a control panel or junction box, ensuring adequate airflow for cooling.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for Profibus-DP communication to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC power supply is correctly wired and within the specified range before operation.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD precautions to protect internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch3\u003eWhat does the IC670PBI001-BE do?\u003c\/h3\u003e\n\u003cp\u003eIt acts as a communication bridge between a Profibus-DP network and the GE Fanuc Field Control I\/O system, allowing the host controller to communicate with remote I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eCan I configure this unit locally?\u003c\/h3\u003e\n\u003cp\u003eYes, the module features a front-facing HHP (Handheld Programmer) connector that allows for local configuration and diagnostic troubleshooting.\u003c\/p\u003e\n\u003ch3\u003eWhat do the LED indicators signify?\u003c\/h3\u003e\n\u003cp\u003eThe PWR LED indicates power status, the OK LED indicates module health, and the RUN LED indicates that the module is actively communicating and running in the system.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50601232761084,"sku":"IC670PBI001-BE","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ea3ab746-cb52-42c2-ae53-6f2d6c01a6f4.jpg?v=1784854857"},{"product_id":"ic670pbi001-ge-fanuc-field-control-profibus-bus-interface-unit","title":"General Electric IC670PBI001 Field Control Profibus Bus Interface Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC670PBI001 is a Profibus Bus Interface Unit (BIU) designed for the Field Control series. This module serves as the communication gateway between a Profibus-DP network and the local Field Control I\/O station. It manages data exchange, diagnostics, and configuration parameters for up to eight I\/O modules connected within the same station.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports standard Profibus-DP communication protocols.\u003c\/li\u003e\n\u003cli\u003eIntegrated support for up to eight (8) Field Control I\/O modules.\u003c\/li\u003e\n\u003cli\u003eConfigurable addressing via embedded DIP switches.\u003c\/li\u003e\n\u003cli\u003eDiagnostic status LEDs for Power (PWR), Run, and OK status.\u003c\/li\u003e\n\u003cli\u003eWide transmission speed range from 9.6 Kbits up to 12 Mbits.\u003c\/li\u003e\n\u003cli\u003eRobust MTBF of 180,000 hours for industrial reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670PBI001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (18-30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.7 W (Input), 4.45 W (Dissipation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProfibus Ports\u003c\/td\u003e\n\u003ctd\u003e1 x 9-pin D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammer Port\u003c\/td\u003e\n\u003ctd\u003e1 x 9-pin D-sub\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Medium\u003c\/td\u003e\n\u003ctd\u003eShielded twisted pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e10 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the power supply is disconnected before mounting or removing the module from the DIN rail or panel.\u003c\/li\u003e\n\u003cli\u003eThe module supports DIN rail or panel mounting via the BIU terminal block.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted pair cabling for Profibus connections to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the cabinet to ensure the ambient temperature remains within the 0-55 degC operating range.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC670PBI001?\u003c\/h3\u003e\u003cp\u003eThe IC670PBI001 acts as a communication interface that allows a Profibus master to control and monitor up to eight Field Control I\/O modules.\u003c\/p\u003e\u003ch3\u003eHow is the station address configured?\u003c\/h3\u003e\u003cp\u003eThe station address is set manually using the embedded DIP switches located on the module.\u003c\/p\u003e\u003ch3\u003eWhat type of cable is required for the Profibus network?\u003c\/h3\u003e\u003cp\u003eThe unit is designed for use with shielded twisted pair cabling to ensure signal integrity across the Profibus segment.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50642563793148,"sku":"IC670PBI001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_bf536cb7-bbc9-4359-8037-350fbc60d0d1.jpg?v=1784891421"},{"product_id":"ic670alg330-ge-fanuc-field-control-8-point-analog-output-module","title":"General Electric IC670ALG330 Field Control 8-Point Analog Current Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC670ALG330 is an 8-point analog current-source output module designed for the Field Control series. This module provides high-precision current output signals for industrial control applications, featuring 16-bit conversion resolution and a nominal output range of 0-20 mA. It is engineered to interface seamlessly with Field Control Bus Interface Units (BIUs), providing reliable analog control for actuators, valves, and other current-driven field devices.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel analog current output configuration.\u003c\/li\u003e\n\u003cli\u003e16-bit conversion resolution with 14-bit magnitude data size.\u003c\/li\u003e\n\u003cli\u003eSupports a nominal output range of 0-20 mA, with a total range of 0.0-20.48 mA.\u003c\/li\u003e\n\u003cli\u003eHigh-speed update time of 1.5 ms typical.\u003c\/li\u003e\n\u003cli\u003eIntegrated open-wire detection with a configurable threshold.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation rated at 1500 VAC for 1 minute.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670ALG330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Current (0-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits (0.3125 uA per count)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18-30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw (BIU)\u003c\/td\u003e\n\u003ctd\u003e85 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw (External)\u003c\/td\u003e\n\u003ctd\u003e250 mA (at 20 mA per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 min) \/ 250 VAC (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Inductance\u003c\/td\u003e\n\u003ctd\u003e0.5 H maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capacitance\u003c\/td\u003e\n\u003ctd\u003e2000 pF maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the Field Control BIU is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the module securely on the designated Field Control carrier or DIN-rail system.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signal lines to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the cable shields at the control cabinet entry point.\u003c\/li\u003e\n\u003cli\u003eVerify that the external 24 VDC power supply is within the 18-30 VDC range and meets the ripple requirements (10% maximum).\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to internal sensitive components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC670ALG330?\u003c\/h3\u003e\u003cp\u003eThis module acts as an 8-channel analog output interface, converting digital data from the controller into precise 0-20 mA current signals to drive field instrumentation.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eYes, the module requires an external 24 VDC power supply, drawing up to 250 mA when all channels are active at full load.\u003c\/p\u003e\u003ch3\u003eWhat is the resolution of the analog output?\u003c\/h3\u003e\u003cp\u003eThe module features a 16-bit conversion resolution, providing a step size of 0.3125 uA per count.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50644578599164,"sku":"IC670ALG330","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_efb58045-ff26-42a6-ba32-ab6c9865addc.jpg?v=1784968887"},{"product_id":"ge-fanuc-ic670mdl730-field-control-discrete-output-module","title":"General Electric IC670MDL730 Field Control Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC670MDL730 is a high-performance discrete output module designed for the Field Control series. This module provides 8 discrete output channels, facilitating reliable control of field devices within industrial automation systems. It is engineered to operate within a nominal 24V DC environment, ensuring compatibility with standard industrial control architectures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 discrete output channels for versatile control applications.\u003c\/li\u003e\n\u003cli\u003eDesigned for the Field Control I\/O system architecture.\u003c\/li\u003e\n\u003cli\u003eSupports a wide operating voltage range of 17.5V DC to 29.5V DC.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for simplified troubleshooting and diagnostics.\u003c\/li\u003e\n\u003cli\u003eRobust short-circuit protection capable of handling 20 Amps for 100 microseconds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE Fanuc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e17.5-29.5 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eNone (Group to Group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort Circuit Response\u003c\/td\u003e\n\u003ctd\u003e20 Amps for 100 microseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the power supply is disconnected before installing or removing the module from the Field Control station.\u003c\/li\u003e\n\u003cli\u003eMount the module securely onto the designated I\/O base to ensure proper electrical connection to the backplane.\u003c\/li\u003e\n\u003cli\u003eVerify that the field wiring is correctly terminated according to the module's pinout configuration.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance around the module to allow for adequate airflow and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage power lines to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC670MDL730?\u003c\/h3\u003e\u003cp\u003eThe IC670MDL730 is a discrete output module used to interface a controller with field-level devices, providing 8 channels of DC output control.\u003c\/p\u003e\u003ch3\u003eWhat is the nominal operating voltage for this module?\u003c\/h3\u003e\u003cp\u003eThe module is designed for a nominal 24V DC input, with an operational range between 17.5V and 29.5V DC.\u003c\/p\u003e\u003ch3\u003eDoes this module provide isolation between output groups?\u003c\/h3\u003e\u003cp\u003eNo, the IC670MDL730 does not feature group-to-group isolation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50644587348220,"sku":"IC670MDL730","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_20fab6c3-1001-4181-8b4d-dc49e3b15b9d.jpg?v=1784969680"},{"product_id":"ic670chs002e-ge-fanuc-field-control-terminal-block","title":"General Electric IC670CHS002E Field Control I\/O Terminal Block","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC670CHS002E is a high-reliability I\/O terminal block designed for the GE Fanuc Field Control series. This component serves as the physical interface for field wiring, providing a secure and organized connection point for I\/O modules within the control system architecture. It is engineered to support hot-swapping, allowing for maintenance and module replacement without requiring a complete system shutdown.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 2 I\/O modules per terminal block.\u003c\/li\u003e\n\u003cli\u003eEquipped with 37 terminals for versatile field wiring configurations.\u003c\/li\u003e\n\u003cli\u003eHot-swap compatible design for enhanced system availability.\u003c\/li\u003e\n\u003cli\u003eMaximum current rating of 10 Amperes per terminal.\u003c\/li\u003e\n\u003cli\u003eCompatible with Field Control modules featuring a catalog number suffix of J or higher.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670CHS002E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eField Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003e2 Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Capacity\u003c\/td\u003e\n\u003ctd\u003e1 x AWG #14 or 2 x AWG #18-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before installing or removing modules from the terminal block.\u003c\/li\u003e\n\u003cli\u003eVerify that the I\/O module revision (suffix J or higher) is compatible with this terminal block version.\u003c\/li\u003e\n\u003cli\u003eFollow proper torque specifications for terminal screws to ensure secure wire retention and prevent intermittent connections.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate spacing for heat dissipation in the control cabinet to ensure long-term reliability.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling where required by the application to minimize EMI interference in industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the IC670CHS002E compatible with older Field Control modules?\u003c\/h3\u003e\u003cp\u003eThis terminal block is specifically designed for modules with a catalog number suffix of J or higher. Please verify your module revision before installation.\u003c\/p\u003e\u003ch3\u003eDoes this terminal block support hot-swapping?\u003c\/h3\u003e\u003cp\u003eYes, the IC670CHS002E is designed to be hot-swap compatible, allowing for module replacement while the system is operational, provided the installation environment and safety protocols allow for it.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50647717085436,"sku":"IC670CHS002E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b9b7e975-7c4d-42c5-b2e5-253b938fd34f.jpg?v=1785064187"},{"product_id":"ic670mdl241-ge-fanuc-field-control-240-vac-input-module","title":"General Electric IC670MDL241 16-Point 240VAC Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC670MDL241 is a 16-point discrete input module designed for the GE Fanuc Field Control I\/O system. This module is engineered to monitor high-voltage AC signals, providing reliable interface capabilities for industrial control applications. It organizes its 16 inputs into two groups, allowing for flexible wiring and isolation between input sections. The module communicates with the Bus Interface Unit (BIU) to provide real-time status data to the controller.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete input points organized into 2 groups of 8.\u003c\/li\u003e\n\u003cli\u003eRated for 240 VAC nominal operation.\u003c\/li\u003e\n\u003cli\u003e250 VAC continuous isolation between the two input groups.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for each input point and a module power (PWR) status LED.\u003c\/li\u003e\n\u003cli\u003eDesigned for vertical mounting within the Field Control rack system.\u003c\/li\u003e\n\u003cli\u003eInternal circuitry includes a network of resistors and capacitors for input filtering and optoisolators for logic-to-field isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCNC Machinery and Metallurgy control systems.\u003c\/li\u003e\n\u003cli\u003eOil, Gas, and Petrochemical process control.\u003c\/li\u003e\n\u003cli\u003eAutomotive manufacturing assembly lines.\u003c\/li\u003e\n\u003cli\u003eWater treatment and municipal engineering systems.\u003c\/li\u003e\n\u003cli\u003ePlastic and textile manufacturing machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16 (2 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e155 to 265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 40 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e4.0 to 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e0 to 1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Input Current\u003c\/td\u003e\n\u003ctd\u003e8.2 mA per point @ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eConnections\u003c\/h3\u003e\u003cp\u003eField devices such as pushbuttons, limit switches, or auxiliary contacts are connected between the 240 VAC \"Hot\" line and the specific input terminal. The neutral line is common for all points within a single group. Each group requires an external 240 VAC power source for operation.\u003c\/p\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for vertical mounting; ensure adequate clearance for airflow and cable management.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs to minimize EMI interference in high-voltage environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the Bus Interface Unit (BIU) is properly seated and providing logic power before commissioning.\u003c\/li\u003e\n\u003cli\u003eObserve ESD precautions when handling the module to prevent damage to internal sensitive electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC670MDL241?\u003c\/h3\u003e\u003cp\u003eIt is a 16-point discrete input module belonging to the GE Fanuc Field Control I\/O family, designed to interface 240VAC signals with the control system.\u003c\/p\u003e\u003ch3\u003eWhat is the input voltage range?\u003c\/h3\u003e\u003cp\u003eThe module operates with an input voltage range of 0 to 265 VAC at a frequency of 47 to 63 Hz.\u003c\/p\u003e\u003ch3\u003eHow do the LEDs function?\u003c\/h3\u003e\u003cp\u003eThe module features 16 individual LEDs to show the status of each input point, and a PWR LED that indicates the presence of both backplane logic power and user field power.\u003c\/p\u003e\u003ch3\u003eIs there isolation between points?\u003c\/h3\u003e\u003cp\u003eThere is no isolation between individual points within a single group, but there is 250 VAC continuous isolation provided between the two groups of 8 points.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50733881786620,"sku":"IC670MDL241","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_5d5451a3-11f6-4c29-9c04-bd357803f5c6.jpg?v=1785285369"},{"product_id":"ge-fanuc-field-control-ic670alg630-analog-input-module","title":"GE Fanuc IC670ALG630-CA Field Control Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC670ALG630-CA is an 8-channel Analog Input Module designed for the Field Control series. This module is engineered for high-precision temperature measurement, supporting a wide range of thermocouple types to provide reliable data acquisition in industrial automation environments. It features a 15-bit plus sign converter resolution, ensuring accurate signal processing for critical process control applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel high-resolution analog input capability.\u003c\/li\u003e\n\u003cli\u003eSupports a comprehensive list of thermocouple types: J, K, T, E, S, R, B, N, G, C, D, and Platinel II.\u003c\/li\u003e\n\u003cli\u003eAdvanced fault detection including open thermocouple detection, over\/under range monitoring, and high\/low alarm thresholds.\u003c\/li\u003e\n\u003cli\u003e15-bit plus sign converter resolution for precise signal digitization.\u003c\/li\u003e\n\u003cli\u003eMaximum voltage isolation between channels rated at 250 VAC.\u003c\/li\u003e\n\u003cli\u003ePower consumption: 195 mA maximum current draw from the BIU power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically utilized in distributed I\/O systems where thermocouple inputs are required for temperature monitoring and control. It is suitable for process industries, manufacturing plants, and CNC-integrated control systems requiring robust analog signal conditioning.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670ALG630-CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits + sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermocouple Types\u003c\/td\u003e\n\u003ctd\u003eJ, K, T, E, S, R, B, N, G, C, D, Platinel II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Spans\u003c\/td\u003e\n\u003ctd\u003e19.5mV, 39mV, 78.125mV, 156.25mV, 312.5mV, 625mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Voltage Between Channels\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e195 mA (from BIU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the Field Control station.\u003c\/li\u003e\n\u003cli\u003eMount the module securely onto the designated I\/O base to ensure proper electrical contact with the backplane.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all thermocouple inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the Field Control rack to ensure signal integrity and safety.\u003c\/li\u003e\n\u003cli\u003eHandle the module with ESD-safe precautions to prevent damage to internal sensitive components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat thermocouple types are supported by the IC670ALG630-CA?\u003c\/h3\u003e\u003cp\u003eThis module supports a wide variety of thermocouple types, including J, K, T, E, S, R, B, N, G, C, D, and Platinel II.\u003c\/p\u003e\u003ch3\u003eWhat is the resolution of this analog input module?\u003c\/h3\u003e\u003cp\u003eThe module features a 15-bit plus sign converter resolution, providing high-fidelity signal conversion for industrial temperature inputs.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50739539247356,"sku":"IC670ALG630","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b391ab65-b746-4273-83fc-f6bd863167bd.jpg?v=1785391895"},{"product_id":"ge-fanuc-ic670mdl644-field-control-fast-input-module","title":"General Electric IC670MDL644 Field Control Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC670MDL644 is a 16-point, 24VDC discrete fast input module designed for the GE Field Control distributed I\/O system. This module provides a single group of 16 inputs capable of operating with either positive or negative logic, offering flexibility for various field device configurations. It utilizes optoisolators to provide robust isolation between field inputs and the internal logic components, ensuring reliable signal processing in industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete inputs in a single group.\u003c\/li\u003e\n\u003cli\u003eSupports both positive and negative logic (source\/sink).\u003c\/li\u003e\n\u003cli\u003eFast input response: 25µs typical ON response.\u003c\/li\u003e\n\u003cli\u003eIntegrated status LEDs for each of the 16 inputs and a dedicated PWR indicator for power supply monitoring.\u003c\/li\u003e\n\u003cli\u003eIsolation: 250 VAC continuous user input to logic; 1500 VAC user input to frame ground for 1 minute.\u003c\/li\u003e\n\u003cli\u003eRequires external 24 VDC power supply for field input devices.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAutomotive manufacturing assembly lines and quality control checkpoints.\u003c\/li\u003e\n\u003cli\u003eOil, gas, and petrochemical facilities for monitoring valve positions and field status.\u003c\/li\u003e\n\u003cli\u003eHigh-speed food and beverage production lines requiring fast signal throughput.\u003c\/li\u003e\n\u003cli\u003eWater treatment and utility infrastructure for monitoring pump stations and environmental equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL644\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e8.0 mA per point @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface Power Draw\u003c\/td\u003e\n\u003ctd\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e3K typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePositive Logic Threshold\u003c\/td\u003e\n\u003ctd\u003e+15V to +30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNegative Logic Threshold\u003c\/td\u003e\n\u003ctd\u003e-15V to -30V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e3.0 mA to 8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e0 mA to 1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn Response Time\u003c\/td\u003e\n\u003ctd\u003e25µs typical, 60µs maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eTo install, tilt the I\/O terminal block and hook the rear tabs over the top of the DIN rail.\u003c\/li\u003e\n\u003cli\u003ePivot the block downward until the spring-loaded latches click securely into place.\u003c\/li\u003e\n\u003cli\u003eTighten the DIN rail clamp screw to prevent lateral movement.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs to minimize EMI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the module to ensure proper thermal dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the GE IC670MDL644?\u003c\/h3\u003e\u003cp\u003eThe IC670MDL644 is a 16-point, 24VDC positive\/negative logic fast input module used within the GE Field Control distributed I\/O system.\u003c\/p\u003e\u003ch3\u003eHow do I wire the IC670MDL644?\u003c\/h3\u003e\u003cp\u003eThe module supports both positive (source) and negative (sink) input logic. The 16 points share a common terminal, allowing for flexible connection to sensors that switch either to common (0V) or to the +24V supply.\u003c\/p\u003e\u003ch3\u003eWhat is the response time of this module?\u003c\/h3\u003e\u003cp\u003eThis is classified as a fast input module with a typical ON response time of 25µs and a maximum of 60µs.\u003c\/p\u003e\u003ch3\u003eDoes the module provide its own power?\u003c\/h3\u003e\u003cp\u003eNo, while the module draws logic power (approx. 80mA) from the Bus Interface Unit, an external 24VDC power supply is mandatory to power the field input devices.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50740284391676,"sku":"IC670MDL644","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ed12c5c5-91d4-4d23-9098-70ec76efdfa3.jpg?v=1785403429"},{"product_id":"ge-fanuc-ic670gbi102-field-control-bus-interface-unit","title":"General Electric IC670GBI102 Powered Genius Bus Interface Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC670GBI102 is a Powered Genius Bus Interface Unit (BIU) belonging to the Field Control series. This module acts as a critical communication node, interfacing Field Control I\/O modules to a host GE CPU via the Genius bus network. It is designed to facilitate distributed I\/O architecture, allowing for scalable and reliable data exchange in industrial automation environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports primary and secondary daisy-chain configurations for network redundancy.\u003c\/li\u003e\n\u003cli\u003eSelectable transmission speeds ranging from 38.4 Kbaud to 153.6 Kbaud.\u003c\/li\u003e\n\u003cli\u003eProvides 256 bytes each for I\/O, AI, and AQ data.\u003c\/li\u003e\n\u003cli\u003eIncludes redundant termination resistors (75, 100, 120, and 150 ohm options).\u003c\/li\u003e\n\u003cli\u003eFeatures a 9-pin D-shell monitor port for Hand-Held Programmer (HHP) connectivity.\u003c\/li\u003e\n\u003cli\u003eBuilt-in overvoltage protection and inrush current management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically utilized in distributed control systems where remote I\/O nodes must communicate with a central controller over a Genius bus. It is commonly found in manufacturing, power generation, and process control applications requiring robust, long-distance communication between the CPU and field-level sensors or actuators.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670GBI102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e48 VA (115 VAC) \/ 24 W (125 VDC) at full load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e20 A peak (max 3 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Speeds\u003c\/td\u003e\n\u003ctd\u003e38.4, 76.8, 153.6 Kbaud (standard\/extended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage (Internal)\u003c\/td\u003e\n\u003ctd\u003e6.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the module is installed in an environment within the 0 to 55 degC temperature range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for standard Field Control rack mounting. Ensure the module is fully seated to maintain proper backplane connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use the integrated screw-type terminals for Genius bus wiring. Ensure proper shielding is maintained for the bus cable to prevent EMI interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swapping:\u003c\/strong\u003e The module supports hot insertion and removal if the specific unit catalog number includes the 'J' suffix. Always verify local safety protocols before performing maintenance on live equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-Down:\u003c\/strong\u003e While hot-swapping is supported for specific revisions, it is recommended to power down the specific I\/O segment before performing physical installation or removal to prevent electrical arcing or data corruption.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC670GBI102?\u003c\/h3\u003e\u003cp\u003eThe GE IC670GBI102 is a Field Control Bus Interface Unit (BIU) designed to act as a node on a Genius I\/O network.\u003c\/p\u003e\u003ch3\u003eWhat is the input power for the IC670GBI102?\u003c\/h3\u003e\u003cp\u003eIt is powered by 115 VAC or 125 VDC.\u003c\/p\u003e\u003ch3\u003eHow does it differ from the IC670GBI002?\u003c\/h3\u003e\u003cp\u003eThe IC670GBI102 uses 115 VAC \/ 125 VDC power, whereas the IC670GBI002 is designed for 24 VDC power systems.\u003c\/p\u003e\u003ch3\u003eWhat are the operating temperature ranges?\u003c\/h3\u003e\u003cp\u003eThe module is rated for operation between 0 degC (32 degF) and 55 degC (131 degF).\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50740463665404,"sku":"IC670GBI102","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_14df97d3-1e05-46ea-a5bf-d94600e772c8.jpg?v=1785408207"},{"product_id":"ic670mdl930-ge-fanuc-field-control-relay-output-module","title":"General Electric IC670MDL930 Field Control Discrete Output Module","description":"\u003cp\u003eThe IC670MDL930 is a Field Control discrete output module manufactured by General Electric (GE Fanuc). This module is designed to provide reliable relay-based output switching for industrial automation systems, featuring eight independent relay output channels.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight (8) relay output channels with fixed coil, moving armature design.\u003c\/li\u003e\n\u003cli\u003eSilver alloy contact material for consistent performance.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for individual channel status and module power monitoring.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of operating voltages including 5\/24\/125 VDC and 120\/240 VAC.\u003c\/li\u003e\n\u003cli\u003eBuilt-in snubber protection for relay contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e0-130 VDC, 0-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current (Resistive)\u003c\/td\u003e\n\u003ctd\u003e16 A per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003e20 cycles\/minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw (from BIU)\u003c\/td\u003e\n\u003ctd\u003e313 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inrush Current\u003c\/td\u003e\n\u003ctd\u003e5 A for 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Load Current\u003c\/td\u003e\n\u003ctd\u003e10 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the Field Control station.\u003c\/li\u003e\n\u003cli\u003eThe module should be seated firmly into the designated base unit to ensure proper backplane communication.\u003c\/li\u003e\n\u003cli\u003eVerify that the load connected to each output does not exceed the specified current ratings for the respective voltage levels.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance around the module to allow for adequate ventilation and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eEnsure all wiring is routed away from high-EMI sources to prevent signal interference.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded cabling where required by the specific application environment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat type of relay is used in the IC670MDL930?\u003c\/h3\u003e\u003cp\u003eThis module utilizes a fixed coil, moving armature relay design with silver alloy contacts.\u003c\/p\u003e\u003ch3\u003eDoes this module include integrated circuit protection?\u003c\/h3\u003e\u003cp\u003eThe module features snubber protection for the relay contacts; however, it does not include internal fuses.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum switching frequency for this module?\u003c\/h3\u003e\u003cp\u003eThe IC670MDL930 is rated for a maximum switching frequency of 20 cycles per minute.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50991416475900,"sku":"IC670MDL930","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_59b6cfd5-7216-44ae-ab5f-cf8dd4b4c435.jpg?v=1786992848"},{"product_id":"ge-fanuc-cnc-ic670chs101c-i-o-terminal-block","title":"GE Fanuc IC670CHS101C Field Control I\/O Terminal Block","description":"\u003cp\u003eThe GE Fanuc IC670CHS101C is a high-density I\/O terminal block designed for the Field Control series. This component serves as the physical interface for field wiring, providing a secure and organized connection point for I\/O modules within the control system architecture.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for integration with the GE Field Control system series.\u003c\/li\u003e\n\u003cli\u003eSupports up to 2 I\/O modules per terminal block assembly.\u003c\/li\u003e\n\u003cli\u003eFeatures 37 individual terminal points for versatile field wiring configurations.\u003c\/li\u003e\n\u003cli\u003eHot-swap compatible, allowing for maintenance and module replacement without interrupting system power.\u003c\/li\u003e\n\u003cli\u003eRobust construction suitable for industrial control environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIC670CHS101C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eI\/O Terminal Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003e2 modules per block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Gauge\u003c\/td\u003e\n\u003ctd\u003e14-22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Terminal Current\u003c\/td\u003e\n\u003ctd\u003e10 Amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is switched off before installing or removing the terminal block or associated I\/O modules.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal block is securely seated on the mounting rail to maintain proper electrical contact with the backplane.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire stripping lengths for 14-22 AWG conductors to ensure a secure connection without exposing excess copper.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing practices to minimize electromagnetic interference (EMI) and ensure adequate airflow for heat dissipation.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent damage to the connector pins during alignment and insertion.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIs the IC670CHS101C hot-swappable?\u003c\/strong\u003e Yes, this terminal block is designed to be hot-swap compatible, supporting module replacement while the system is operational.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow many modules can this block accommodate?\u003c\/strong\u003e This specific terminal block is designed to support up to 2 I\/O modules.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the wire size range for the terminals?\u003c\/strong\u003e The terminals are designed to accommodate wire gauges ranging from 14 to 22 AWG.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50995081281788,"sku":"IC670CHS101C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_f1a7fe6a-a94d-4e51-9d56-d6fa70277312.jpg?v=1787074510"},{"product_id":"ge-fanuc-cnc-ic670gbi002d-bus-interface-unit","title":"GE Fanuc IC670GBI002D Field Control Bus Interface Unit","description":"\u003cp\u003eThe GE Fanuc IC670GBI002D is a high-performance Bus Interface Unit (BIU) designed for the Field Control I\/O system. This module serves as the primary communication bridge between the field I\/O devices and the host controller, facilitating reliable data exchange in industrial automation environments. Engineered for durability and flexibility, it supports advanced features such as CPU redundancy and hot-swappable module maintenance to minimize system downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports CPU redundancy for enhanced system availability and fault tolerance.\u003c\/li\u003e\n\u003cli\u003eDesigned for hot insertion and removal of I\/O modules, allowing for maintenance without shutting down the entire process.\u003c\/li\u003e\n\u003cli\u003eRobust power management with support for a wide range of input voltages.\u003c\/li\u003e\n\u003cli\u003eHigh MTBF rating exceeding 183,000 hours, ensuring long-term operational reliability.\u003c\/li\u003e\n\u003cli\u003eCompatible with the broader GE Field Control IC670G\/IC670GBI series architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis Bus Interface Unit is typically utilized in distributed control systems, manufacturing automation, and process control applications where reliable, high-speed communication between field sensors\/actuators and the central PLC or DCS is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIC670GBI002D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE Fanuc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBus Interface Unit (BIU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Rated Voltage\u003c\/td\u003e\n\u003ctd\u003e115 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e90-135 VAC \/ 105-150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e16.8 W (at 24 VDC) \/ 24 W (at 125 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e15-50 A peak (3 ms max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued \/ Obsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the power is disconnected before installing or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eThe module supports hot-swapping; however, verify that the local safety protocols allow for live maintenance in your specific environment.\u003c\/li\u003e\n\u003cli\u003eMount the unit in a clean, dry, and vibration-free enclosure to maintain the integrity of the internal electronics.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the Field Control rack to prevent EMI interference and protect against voltage surges.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate spacing around the module to allow for proper thermal dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC670GBI002D?\u003c\/h3\u003e\u003cp\u003eThe IC670GBI002D acts as the interface between the Field Control I\/O station and the communication bus, managing data traffic and status reporting for the connected I\/O modules.\u003c\/p\u003e\u003ch3\u003eIs this module still in production?\u003c\/h3\u003e\u003cp\u003eNo, the IC670GBI002D is currently classified as discontinued or obsolete by the manufacturer. We provide these units as reliable spare parts for legacy system maintenance.\u003c\/p\u003e\u003ch3\u003eDoes this module support hot-swapping?\u003c\/h3\u003e\u003cp\u003eYes, the Field Control architecture supports the hot insertion and removal of modules, allowing you to replace or add components while the system is under power, provided the specific application safety requirements are met.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50998364242172,"sku":"IC670GBI002D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_17ead1a3-dfcd-4f7d-81eb-d2afe8528f1b.jpg?v=1787166585"},{"product_id":"ge-fanuc-ic670alg320-field-control-analog-output-module","title":"GE Fanuc IC670ALG320 Field Control Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC670ALG320 is a 4-channel analog output module designed for the Field Control I\/O system. This module converts digital control signals from a host processor into precise analog current or voltage outputs, facilitating the control of industrial actuators, regulating valves, dampers, and positioners. It is widely utilized in process automation environments, including power generation, oil and gas, and chemical manufacturing, where high-resolution signal stability is required.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour independent sourcing channels for current or voltage output.\u003c\/li\u003e\n\u003cli\u003eConfigurable output ranges: 0-20 mA, 4-20 mA, 0-10 VDC, and 0-12.5 VDC.\u003c\/li\u003e\n\u003cli\u003e12-bit digital-to-analog conversion resolution.\u003c\/li\u003e\n\u003cli\u003eIntegrated EMI filtering and ground isolation to protect signal integrity against electrical noise.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for monitoring field power and backplane bus status.\u003c\/li\u003e\n\u003cli\u003eConfigurable via external jumper links on the terminal block or internal register adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for applications requiring precise analog control, such as modulating control valves, variable frequency drive (VFD) speed references, and position control for industrial actuators. It is compatible with Field Control and Rx7i PACSystems architectures.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670ALG320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4 Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, 0-10 VDC, 0-12.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Speed\u003c\/td\u003e\n\u003ctd\u003e60 microseconds per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e20-29 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 min) \/ 250 VAC (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.4 W (min) to 4.3 W (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the carrier.\u003c\/li\u003e\n\u003cli\u003eUse instrumentation-grade shielded twisted-pair cabling to minimize susceptibility to electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the external 24 VDC power supply is within the 20-29 VDC range and meets the ripple requirements.\u003c\/li\u003e\n\u003cli\u003eConfigure output ranges using the appropriate jumper settings on the terminal block assembly before applying power.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the enclosure to manage thermal dissipation, which can reach up to 4.3 Watts.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is installed in a clean, dry environment free from conductive dust and liquid ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module compatible with all Field Control systems?\u003c\/h3\u003e\u003cp\u003eThe IC670ALG320 is designed for the Field Control I\/O series and is also compatible with specific Rx7i PACSystems architectures. Please verify your specific rack and Bus Interface Unit (BIU) compatibility before installation.\u003c\/p\u003e\u003ch3\u003eHow do I change the output range?\u003c\/h3\u003e\u003cp\u003eThe output range can be modified by adjusting the external jumper links located on the mounting terminal block assembly or by configuring the internal registers via a handheld programmer.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51000402280700,"sku":"IC670ALG320","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_2413ceb7-feaf-4ac6-940d-55f591ac25c5.jpg?v=1787250580"}],"url":"https:\/\/www.electronicplc.com\/collections\/ge-field-control.oembed?page=2","provider":"Electronic PLC","version":"1.0","type":"link"}