{"title":"GE Multilin","description":"\u003cp\u003e\u003cspan\u003eThe GE Multilin series is the industry standard for power system protection and substation automation. This collection includes motor protection, feeder protection, and transformer relays designed to safeguard electrical assets from faults and operational anomalies. These devices are critical for integrating advanced monitoring and control within power distribution networks. Our Multilin inventory focuses on providing the necessary hardware to maintain power system reliability, supporting high-speed communications and precise protection logic to prevent costly equipment damage and unplanned outages in utility and industrial applications.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"ge-multilin-ur-6ch-digital-i-o-control-module","title":"GE Multilin UR 6CH Digital I\/O Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 6CH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital input\/output module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides additional binary I\/O points to monitor substation sensors, status contacts, and control signals, supporting deterministic performance for critical industrial applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 6CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial substation automation and relay logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExpands digital control and feedback points in UR relay racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffloads I\/O management to streamline complex automation logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports precise control of switchgear and protection equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for high-availability environments requiring consistent signal processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the UR 6CH interface with the relay system?\u003c\/strong\u003e\u003cbr\u003eIt connects to the UR internal backplane and is automatically recognized by the CPU for logic configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR 6CH compatible with all UR chassis versions?\u003c\/strong\u003e\u003cbr\u003eGenerally yes, but verify CPU firmware and rack revision to ensure full operational compatibility.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730356988,"sku":"UR6CH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-6fh-digital-i-o-control-module-ge-multilin","title":"UR 6FH Digital I\/O Control Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 6FH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital input\/output module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides reliable digital signaling for monitoring and control, enabling high-performance automation and protection in industrial substation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eUR 6FH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Integration\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial substation automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed digital state detection and command execution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless integration within UR rack architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable via EnerVista UR for customized protection logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt to meet industrial standards for reliability and signal availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the I\/O points?\u003c\/strong\u003e\u003cbr\u003eUse EnerVista UR software to assign functions, monitor status, and run diagnostics for each channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with all UR relay chassis?\u003c\/strong\u003e\u003cbr\u003eGenerally yes, but verify your rack serial number and firmware version to ensure correct CPU recognition.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730389756,"sku":"UR67H","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8LH.jpg?v=1773216372"},{"product_id":"ur-8fh-analog-input-module-ge-multilin","title":"UR 8FH Analog Input Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8FH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a horizontal-format analog input module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides precise analog signal acquisition for monitoring electrical parameters, enabling the relay to execute real-time protection logic and maintain grid stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8FH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eHorizontal Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e40 mm × 185 mm × 172 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSubstation protection and measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-precision analog signal acquisition for relay protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable interface between primary sensors and relay CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHorizontal layout for seamless integration into UR racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for industrial thermal and electromagnetic conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR 8FH hot-swappable?\u003c\/strong\u003e\u003cbr\u003eNo. Power must be removed from the UR rack before installing or replacing the module to protect the backplane and communication bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify compatibility with my UR rack?\u003c\/strong\u003e\u003cbr\u003eCheck your relay chassis version and firmware against the UR 8FH specifications in the hardware manual to ensure proper fit and operation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730619132,"sku":"UR 8FH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH1.jpg?v=1773216372"},{"product_id":"ur-8hh-ct-vt-analog-input-module-ge-multilin","title":"UR 8HH CT VT Analog Input Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8HH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated analog measurement module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It interfaces with current and voltage transformers (CTs and VTs) to step down high-magnitude primary signals, providing precise 1A\/5A phase and ground current measurements.\u003c\/p\u003e\n\u003cp\u003eThis accuracy enables the relay to execute protective functions reliably and maintain power system stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8HH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003e3 × 1A\/5A phase CTs, 1 × 1A\/5A ground CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Integration\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8HH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates seamlessly into the UR chassis, enabling high-fidelity data acquisition. Measurements can be displayed on the relay’s local LCD or exported via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor detailed analysis. The module supports customizable protection schemes, allowing engineers to set site-specific thresholds and monitor system conditions in real time while preserving signal integrity from field sensors to the relay CPU.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the UR 8HH be configured for different CT ratios?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports programmable CT\/VT scaling through\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e, allowing adaptation to various primary sensor ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eNo. Always de-energize the relay rack and follow lockout\/tagout procedures before inserting or removing the UR 8HH to prevent electrical hazards and bus communication errors.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730848508,"sku":"UR8HH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-9eh-cpu-processor-module-ge-multilin","title":"UR 9EH CPU Processor Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a core processing module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. Serving as the primary computational engine of the relay, the UR 9EH handles critical operations such as complex logic algorithms, latching sequences, and precise timing functions essential for power system protection.\u003c\/p\u003e\n\u003cp\u003eThe module is suitable for both upgrading legacy systems and replacing existing CPUs, ensuring reliable performance and integration within the UR platform.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eUR 9EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCentral Processing Unit (CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.5 in × 6 in × 2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIntegration and Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlug \u0026amp; Play functionality\u003c\/strong\u003e, allowing the system to auto-detect and initialize settings upon startup. To ensure operational stability and prevent errors such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHARDWARE MISMATCH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSP ERROR\u003c\/strong\u003e, the CPU module generation must match the CT\/VT module generation.\u003c\/p\u003e\n\u003cp\u003eNew UR 9EH modules should be paired with modern CT\/VT counterparts, while legacy CPU modules should remain paired with older analog input modules to maintain communication integrity across the UR relay system.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Optimization\u003c\/h3\u003e\n\u003cp\u003eThe module is fully configurable through the relay’s front-panel keypad or via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e. Advanced users can optimize CPU performance by selectively disabling features, such as server scanning, which frees resources if\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 client\/server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication is not required in the network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older UR CPU with a new UR 9EH without updating other modules?\u003c\/strong\u003e\u003cbr\u003eCompatibility is version-dependent. Installing a new\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealongside older CT\/VT modules may lead to communication errors. Always verify the compatibility of your existing backplane and I\/O modules before performing upgrades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I free up resources on this CPU?\u003c\/strong\u003e\u003cbr\u003eThrough\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e, non-essential features like server scanning can be disabled to optimize CPU performance, especially if IEC 61850 communication is not being utilized in your specific system.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731012348,"sku":"UR9EH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-rhh-ge-multilin-power-supply-module","title":"UR RHH GE Multilin Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized power supply module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides stable and regulated power to relay electronics, ensuring reliable operation of mission-critical protection and control functions in substation environments.\u003c\/p\u003e\n\u003cp\u003eWith robust construction and dependable DC\/AC conversion capabilities, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential component for maintaining continuous uptime and optimal performance within the UR relay architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR RHH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDC\/AC Power Input Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e40 mm × 225 mm × 292 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance and Reliability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to provide consistent voltage to internal relay components, preventing performance degradation or data errors during transient grid disturbances. Its compact, rack-mountable design allows easy integration into existing UR hardware assemblies, supporting efficient use of substation panel space.\u003c\/p\u003e\n\u003cp\u003eBuilt to withstand industrial thermal and electrical stresses, the module ensures reliable operation of UR relays even under challenging environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR RHH compatible with all Universal Relay (UR) chassis types?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for the UR relay family; however, compatibility depends on the specific relay backplane version and the power requirements of connected CPU and modules. Always verify hardware specifications before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require cooling fans for operation?\u003c\/strong\u003e\u003cbr\u003eNo. The module is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econvection cooling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin standard UR relay housings. Ensure that the rack installation allows adequate airflow as recommended in the installation manual to maintain optimal operating temperatures.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731438332,"sku":"URRHH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR-RHH.jpg?v=1773212383"},{"product_id":"ur-8nh-ge-multilin-ct-vt-analog-input-module","title":"UR 8NH  GE Multilin CT VT Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized analog input module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It delivers high-fidelity acquisition of current transformer (CT) and voltage transformer (VT) signals, enabling precise waveform monitoring and accurate data processing for advanced power system protection schemes.\u003c\/p\u003e\n\u003cp\u003eEngineered for critical electrical infrastructure, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a key interface between field measurement devices and the relay’s central processing unit. With integrated diagnostic capabilities and high-resolution analog-to-digital conversion, the module ensures reliable signal acquisition for substation protection and automation applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8NH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eCT\/VT Analog Measurement Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.75 in × 10.50 in × 4.50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003eHigh-precision analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eReal-time internal channel monitoring and self-test routines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a critical interface between primary measurement sensors and the relay’s protection logic. By continuously monitoring internal channel performance, the module can quickly detect anomalies or hardware faults that may affect measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eIf a malfunction is detected, the system can automatically block associated protection trip commands, ensuring that protection actions are based only on verified and reliable measurement data. This safeguard helps prevent nuisance tripping and enhances the operational security of the power system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the UR 8NH require manual configuration after installation?\u003c\/strong\u003e\u003cbr\u003eYes. After installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule, the relay must be configured using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e. This configuration step maps CT and VT inputs to the appropriate protection elements within the relay logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older UR relay chassis models?\u003c\/strong\u003e\u003cbr\u003eCompatibility depends on the CPU firmware version and the backplane revision of the relay chassis. It is recommended to verify the rack serial number and firmware version against the module’s technical documentation before installation to ensure proper system integration.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731962620,"sku":"UR8NH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH1.jpg?v=1773216372"},{"product_id":"ge-multilin-ur-8lh-analog-ct-vt-input-module","title":"GE Multilin UR 8LH Analog CT VT Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog input module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. Designed for mission-critical substation automation, the module provides accurate acquisition of current transformer (CT) and voltage transformer (VT) signals, enabling reliable protection, monitoring, and measurement for electrical power systems.\u003c\/p\u003e\n\u003cp\u003eWith advanced signal conditioning and built-in diagnostics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures stable data acquisition while supporting the protection logic of the relay system. Its robust construction and integrated monitoring functions help maintain system integrity in demanding utility and industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCT\/VT Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Series\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Supply\u003c\/td\u003e\n\u003ctd\u003e100–240 V AC, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Thermal Range\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm × 150 mm × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Capability\u003c\/td\u003e\n\u003ctd\u003eIntegrated self-monitoring for analog signal integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Interlocks\u003c\/td\u003e\n\u003ctd\u003eAutomatic fault-triggered alarm and protection blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates advanced diagnostic algorithms that continuously monitor the integrity of analog input channels. If a measurement anomaly or internal hardware issue is detected, the module automatically generates a system alarm and temporarily blocks associated relay trip outputs. This protective mechanism prevents false operations and enhances overall system safety.\u003c\/p\u003e\n\u003cp\u003eFor optimal performance, proper system integration requires verification of CPU firmware compatibility within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack assembly. Ensuring firmware alignment allows the module to communicate effectively with other relay components and maintain accurate data processing across the protection system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable in a running UR chassis?\u003c\/strong\u003e\u003cbr\u003eIt is strongly recommended to de-energize the relay rack before inserting or removing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule. This precaution helps prevent electrical transients and avoids potential communication errors on the relay backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle sensor calibration?\u003c\/strong\u003e\u003cbr\u003eThe module supports digital calibration through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR configuration software suite\u003c\/strong\u003e, allowing engineers to adjust CT and VT ratio parameters during system commissioning to ensure accurate measurement and protection performance.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746732028156,"sku":"UR8LH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8LH.jpg?v=1773216372"},{"product_id":"ge-multilin-g60-generator-management-protection-relay","title":"GE Multilin G60 Generator Management Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated protection and control terminal specifically engineered for the management of medium and large synchronous generators. It delivers a comprehensive suite of protection, monitoring, and control functions within a highly modular hardware architecture, ensuring maximum availability and reliability for critical power generation assets.\u003c\/p\u003e\n\u003cp\u003eAs part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e, the G60 combines advanced generator protection algorithms with integrated metering, disturbance recording, and flexible communication capabilities. This allows operators and engineers to maintain system stability while gaining deep insight into generator operating conditions and fault events.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Model\u003c\/td\u003e\n\u003ctd\u003eGE Multilin G60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Suite\u003c\/td\u003e\n\u003ctd\u003eDifferential, out-of-step, loss-of-field, stator ground fault, pole slip, overcurrent, and voltage-based protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Metering\u003c\/td\u003e\n\u003ctd\u003eReal-time monitoring of voltage, current, power, and energy parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Configuration\u003c\/td\u003e\n\u003ctd\u003eModular draw-out design available in single-bay and multi-bay formats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eHigh-contrast menu-driven backlit LCD for local diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisturbance Analysis\u003c\/td\u003e\n\u003ctd\u003eAdvanced event and fault recording for post-event system analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in power generation facilities to protect synchronous generators and associated transformers. Its advanced generator-specific protection algorithms make it particularly valuable in thermal, hydroelectric, and combined-cycle power plants.\u003c\/p\u003e\n\u003cp\u003eBeyond traditional utility environments, the relay is also used in large industrial facilities for motor protection and control, as well as in renewable energy infrastructure such as wind and solar farms where generator protection and grid interconnection reliability are critical.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes the G60 suitable for power plants?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates specialized protection algorithms designed specifically for generator operating conditions, including loss-of-field detection, pole-slip protection, and out-of-step protection—functions not typically available in standard protection relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the device support modern SCADA environments?\u003c\/strong\u003e\u003cbr\u003eYes. The relay supports multiple industry-standard communication protocols, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDNP3\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e, enabling seamless integration with modern SCADA and substation automation systems.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733043964,"sku":"G60","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/G601.jpg?v=1773212380"},{"product_id":"ge-multilin-t35-transformer-protection-relay-system","title":"GE Multilin T35 Transformer Protection Relay System","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a comprehensive three-phase transformer management relay engineered for the primary protection and monitoring of power transformer assets. This digital protection device integrates advanced protection algorithms with flexible automation capabilities, enabling high-speed fault detection and dependable operation in demanding electrical distribution environments.\u003c\/p\u003e\n\u003cp\u003eDesigned as part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e, the T35 provides sophisticated transformer differential protection, harmonic restraint, thermal monitoring, and event recording. These capabilities allow operators to maintain system stability while protecting valuable transformer infrastructure in both utility and industrial power networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Model\u003c\/td\u003e\n\u003ctd\u003eGE Multilin T35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Power Input\u003c\/td\u003e\n\u003ctd\u003e125 \/ 250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Channels\u003c\/td\u003e\n\u003ctd\u003e3 × 1A \/ 5A Phase CTs + 1 × 1A \/ 5A Ground CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Channels\u003c\/td\u003e\n\u003ctd\u003e4 × 120V \/ 240V VTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relay Ratings\u003c\/td\u003e\n\u003ctd\u003e24V DC to 250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in utility substations and industrial power systems where reliable transformer protection is critical. It is specifically designed to safeguard medium-to-large power transformers and supports advanced protection schemes such as transformer differential protection, harmonic blocking, and thermal overload monitoring.\u003c\/p\u003e\n\u003cp\u003eBy integrating multiple protection and monitoring functions into a single platform, the relay provides operators with a comprehensive view of transformer health, helping to minimize downtime and prevent catastrophic equipment failures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the T35 relay?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a dedicated transformer protection relay. It processes CT and VT inputs to detect internal faults, abnormal current conditions, and thermal overload situations, enabling fast and reliable tripping to protect critical power assets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the device suitable for extreme outdoor environments?\u003c\/strong\u003e\u003cbr\u003eYes. With an operating temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C to +85°C\u003c\/strong\u003e, the relay is engineered to operate reliably in harsh industrial and substation environments, including installations without climate-controlled enclosures.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733076732,"sku":"T35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/T35.jpg?v=1773212382"},{"product_id":"ge-multilin-f35-feeder-protection-relay","title":"GE Multilin F35 Feeder Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin F35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efeeder protection relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to safeguard medium- and high-voltage distribution networks. Part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR (Universal Relay) family\u003c\/strong\u003e, it delivers advanced protection, control, and monitoring for feeders, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003earc-flash detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebreaker failure protection\u003c\/strong\u003e. Its modular architecture supports customizable I\/O configurations, making it ideal for complex industrial and utility substation applications.\u003c\/p\u003e\n\u003cp\u003eEngineered for digital substations, the F35 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-fidelity disturbance recording\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eevent logging\u003c\/strong\u003e, and robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 communication\u003c\/strong\u003e, enabling seamless integration into automated grid systems. Its intuitive interface and diagnostic tools enhance feeder management while reducing downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eF35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFeeder Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Protection Elements\u003c\/td\u003e\n\u003ctd\u003eOvercurrent, Voltage, Frequency, Directional Power, Breaker Failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Diagnostics\u003c\/td\u003e\n\u003ctd\u003eArc-Flash Detection, Waveform Capture, Sequence of Events (SOE) Recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, Modbus, DNP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Architecture\u003c\/td\u003e\n\u003ctd\u003eUR (Universal Relay) Modular Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003eLarge graphical display for metering and status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eRole-based access control, security auditing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Arc-Flash Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed light and current sensing reduces equipment damage and enhances personnel safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlexible UR platform allows expansion of I\/O boards for complex feeder requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCOMTRADE-compliant disturbance and fault data for in-depth analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt for consistent performance under extreme electrical and thermal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F35 support integration with IEC 61850 substations?\u003c\/strong\u003e\u003cbr\u003eYes, it is fully compliant with IEC 61850, supporting GOOSE messaging for fast protection and interoperability in digital substations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the F35 detect arc flashes?\u003c\/strong\u003e\u003cbr\u003eYes, the relay includes dedicated arc-flash detection logic. When paired with light-sensitive sensors, it delivers rapid response to clear arc faults in switchgear.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733142268,"sku":"F35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F35-F53U04-HKH.jpg?v=1773133040"},{"product_id":"ge-multilin-239-an-h-motor-protection-relay","title":"GE Multilin 239-AN-H Motor Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin 239-AN-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicroprocessor-based motor protection relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for three-phase AC motors and their drive systems. Part of the 239 series, it provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomprehensive protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincluding thermal overload, phase unbalance, jam detection, undercurrent, and ground fault monitoring. The “-H” designation indicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eharsh environment conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor protection against moisture, dust, and chemical exposure.\u003c\/p\u003e\n\u003cp\u003eThe relay supports a wide AC\/DC supply range and connects to automation networks via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS485 Modbus RTU\u003c\/strong\u003e, enabling remote monitoring and configuration. Its robust design helps prevent motor damage, reduce downtime, and extend asset life in demanding industrial settings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e239-AN-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Elements\u003c\/td\u003e\n\u003ctd\u003eThermal Overload, Ground Fault, Phase Unbalance, Jam, Undercurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e70–265 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e30 W \/ 30 VA Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e10 A at 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485 (Modbus RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eHarsh Environment Conformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.81 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Inhibit Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrevents motor restart until thermal conditions are safe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal coating protects against dust, humidity, and corrosive conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS485 enables remote monitoring and parameter adjustments via SCADA\/PLC systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProven Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSolid-state platform provides precise protection even in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 239-AN-H require external hardware for ground fault protection?\u003c\/strong\u003e\u003cbr\u003eNo, the relay includes integrated ground fault protection, but CT configuration must match the motor circuit design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the communication port be used to program the relay settings?\u003c\/strong\u003e\u003cbr\u003eYes, the RS485 Modbus RTU port allows full remote configuration and status monitoring with compatible software.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733633788,"sku":"239-AN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/239-AN.jpg?v=1773126954"},{"product_id":"ge-multilin-m60-motor-protection-system-industrial-relay","title":"GE Multilin M60 Motor Protection System Industrial Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin M60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotor protection system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emedium to large three-phase induction motors\u003c\/strong\u003e. It delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadvanced protection, control, and diagnostics\u003c\/strong\u003e, making it ideal for mission-critical industrial applications. The M60 features flexible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal overload models\u003c\/strong\u003e—standard, custom, and voltage-dependent—ensuring precise motor safeguarding under varied operating conditions.\u003c\/p\u003e\n\u003cp\u003eWith native\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 support\u003c\/strong\u003e, including SCL integration and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR-GOOSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication, the system enables modern digital substation connectivity. Security is ensured with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-permission access controls\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand detailed command logging. Configuration is simplified through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista M60 Autoconfigurator\u003c\/strong\u003e, and the system provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density programmable I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOMTRADE 2013-compliant waveform capture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor advanced disturbance analysis.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eMultilin M60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMedium to large three-phase induction motor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Curves\u003c\/td\u003e\n\u003ctd\u003eStandard, Custom, Voltage-dependent thermal models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, R-GOOSE, Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording Standards\u003c\/td\u003e\n\u003ctd\u003eCOMTRADE 2013 (Waveform Capture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eDual-permission access, user command logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eFull-color, high-resolution interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eHigh-density programmable I\/O, flexible process bus support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFault and disturbance recording for in-depth post-event analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutoconfigurator reduces engineering time and streamlines logic deployment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScalable I\/O to meet complex automation requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePermission-based access and command logging protect critical system changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the M60 support IEC 61850 network integration?\u003c\/strong\u003e\u003cbr\u003eYes. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflexible process bus architectures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCL file integration\u003c\/strong\u003e, enabling seamless integration into modern digital substations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the M60 record waveform data for fault analysis?\u003c\/strong\u003e\u003cbr\u003eYes. The M60 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOMTRADE 2013-compliant waveform capture\u003c\/strong\u003e, facilitating detailed disturbance and fault event analysis.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746734387452,"sku":"M60","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/M601.jpg?v=1773130971"},{"product_id":"ge-multilin-469-p5-hi-a20-t-h-motor-management-relay","title":"GE Multilin 469-P5-HI-A20-T-H Motor Management Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a microprocessor-based motor protection and management relay from the Multilin 469 series. It is designed for medium to large horsepower motors, providing comprehensive electrical and mechanical fault protection, advanced thermal modeling, and integrated diagnostics.\u003c\/p\u003e\n\u003cp\u003eThis configuration supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5A CT inputs\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-voltage control power\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour programmable 4–20 mA outputs\u003c\/strong\u003e, making it suitable for high-voltage industrial control systems and SCADA integration. The conformal coating option ensures reliable operation in harsh environments with humidity or corrosive gases.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e469-P5-HI-A20-T-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMultilin 469 Motor Management System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input (P5)\u003c\/td\u003e\n\u003ctd\u003e5 A Phase CT Secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power (HI)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC \/ 70–265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs (A20)\u003c\/td\u003e\n\u003ctd\u003e4 × isolated 4–20 mA (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option (T)\u003c\/td\u003e\n\u003ctd\u003eConformal coating (harsh environment protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting (H)\u003c\/td\u003e\n\u003ctd\u003eHorizontal chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 × RS232 (front), 2 × RS485 (rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU (up to 19.2 kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e12 × 100 Ω Platinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Functions\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, kW, kVAR, kVA, Energy, Demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H×W×D)\u003c\/td\u003e\n\u003ctd\u003e223.5 × 216.4 × 252.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThree-phase induction and synchronous motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-inertia loads requiring acceleration protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVFD-driven motor monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePumps, compressors, and fans in power, oil \u0026amp; gas, and heavy industry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the “T” option indicate?\u003c\/strong\u003e\u003cbr\u003eIt denotes conformal-coated internal PCBs for protection against moisture, chemicals, and H₂S exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with 1A CTs?\u003c\/strong\u003e\u003cbr\u003eNo. The P5 variant is calibrated strictly for 5A CT secondaries. A 1A model variant is required for 1A CT systems.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746769383676,"sku":"469-P5-HI-A20","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/469-P5-HI-A20-T-H.jpg?v=1772092232"},{"product_id":"735-5-5-hi-485-ge-multilin-feeder-protection-relay","title":"735-5-5-HI-485 GE Multilin Feeder Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision feeder protection relay from the GE Multilin family. It is designed for the protection and monitoring of electrical distribution feeders in industrial and utility power systems.\u003c\/p\u003e\n\u003cp\u003eThis microprocessor-based relay combines instantaneous and time-delayed overcurrent protection with ground fault detection, ensuring reliable feeder protection and system stability. Although now discontinued, it remains an essential component for maintaining legacy switchgear and power monitoring infrastructures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e735-5-5-HI-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Protection\u003c\/td\u003e\n\u003ctd\u003e50\/51 Phase Overcurrent (Instantaneous and Time Delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Protection\u003c\/td\u003e\n\u003ctd\u003e50G\/51G Ground Fault (Instantaneous and Time Delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply (HI)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC or 70–265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485 2-wire serial port (SCADA integration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eDigital setpoint adjustment for trip curves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eTrue RMS current sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eDraw-out or fixed-mount relay housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUtility substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge industrial power distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofitted switchgear requiring RS485 SCADA integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFacilities with varying DC battery or AC auxiliary power sources\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt protects feeder circuits against short circuits, overloads, and ground faults while supporting remote monitoring and fault analysis.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 735-5-5-HI-485 still in production?\u003c\/strong\u003e\u003cbr\u003eNo. The model is discontinued by the manufacturer but remains available as refurbished or surplus units to support legacy installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does “5-5” indicate in the model number?\u003c\/strong\u003e\u003cbr\u003eThe “5-5” designation signifies compatibility with 5 A Phase and 5 A Ground current transformer secondary inputs, ensuring standard CT integration for feeder protection.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746788356348,"sku":"735-5-5-HI-485","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/735-5-5-HI-485.jpg?v=1770948453"},{"product_id":"spso2-surge-protection-module-abb","title":"SPSO2 Surge Protection Module ABB","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPSO2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPSO2\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance surge protective device (SPD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom ABB, specifically designed to safeguard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSymphony Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems and sensitive industrial electronics against transient overvoltages. This module protects equipment from atmospheric surges (e.g., lightning) and internal switching transients, preventing costly downtime and hardware damage in critical automation environments.\u003c\/p\u003e\n\u003cp\u003eWith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efast response time of \u0026lt;25 ns\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand high discharge capacity, the SPSO2 ensures that surges are clamped before they reach delicate silicon components. Its compact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e36 mm DIN-rail mount\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehousing is ideal for high-density cabinets, providing robust protection without consuming excessive space. Built for harsh industrial environments, the SPSO2 combines reliability, ease of installation, and long-term operational stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eSPSO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Operating Voltage (MCOV)\u003c\/td\u003e\n\u003ctd\u003e320 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Discharge Current (In, 8\/20 μs)\u003c\/td\u003e\n\u003ctd\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Discharge Current (Imax, 8\/20 μs)\u003c\/td\u003e\n\u003ctd\u003e40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Protection Level (Up)\u003c\/td\u003e\n\u003ctd\u003e≤ 1.8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 25 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current Rating (SCCR)\u003c\/td\u003e\n\u003ctd\u003e25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 mm² to 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e90 mm x 36 mm x 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e1.24 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Surge Clamping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSub-25 ns response protects sensitive electronics before damage occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Discharge Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHandles up to 40 kA for indirect lightning and switching surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e36 mm DIN-rail footprint allows dense enclosure installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccommodates cable sizes from 2.5 mm² to 35 mm².\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWide -40°C to +80°C operating range for harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Friendly:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20, finger-safe design with visual end-of-life indicator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProtects turbine controllers, governors, and sensor electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater \u0026amp; Wastewater:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShields PLCs, I\/O modules, and instrumentation from voltage spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy Manufacturing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGuards automation cabinets in metal processing, pulp \u0026amp; paper, and chemical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know if the SPSO2 has reached end of life?\u003c\/strong\u003e\u003cbr\u003eThe module features a visual status window. A color change (usually green → red) indicates that the internal protection components have been used and the unit must be replaced.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SPSO2 protect against direct lightning strikes?\u003c\/strong\u003e\u003cbr\u003eIt is rated for indirect lightning and switching surges up to 40 kA (8\/20 μs). For direct strikes, the SPSO2 should be part of a coordinated Type 1 lightning protection system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module easy to install in crowded cabinets?\u003c\/strong\u003e\u003cbr\u003eYes. Its 36 mm width (2-module DIN size) and standard screw terminals allow space-efficient, secure installation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48746791010556,"sku":"SPS02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SPS02_d8e0aff4-3f14-487e-bb2d-41a5ca823cc9.jpg?v=1770621502"},{"product_id":"900c30-0360-00-honeywell-hc900-c30","title":"900C30-0360-00 Honeywell HC900 C30","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900C30-0360-00 serves as the primary processing engine of the ControlEdge HC900 hybrid control system. This CPU module executes advanced control strategies—including PID loops and logic sequencing—while managing communication between the controller and distributed I\/O racks. It acts as the central “brain” of the system, delivering reliable performance for both discrete and process control applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e900C30-0360-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Blocks\u003c\/td\u003e\n\u003ctd\u003eUp to 400 blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Capacity\u003c\/td\u003e\n\u003ctd\u003e96 Universal \/ 192 High Level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Capacity\u003c\/td\u003e\n\u003ctd\u003e40 Standard \/ up to 192 (external power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 384 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137 × 35.6 × 137.16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHybrid Control Efficiency\u003c\/strong\u003e\u003cbr\u003eCombines PLC-style discrete logic and DCS-level process control in a single CPU, eliminating the need for separate systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision PID Execution\u003c\/strong\u003e\u003cbr\u003eSupports up to 400 function blocks, enabling complex control strategies such as cascade and ratio control without compromising performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Processing Power\u003c\/strong\u003e\u003cbr\u003eLightweight and space-efficient design delivers high I\/O handling capacity, ideal for skid systems and compact control panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless I\/O Integration\u003c\/strong\u003e\u003cbr\u003eEnsures fast communication with local and remote I\/O racks, maintaining real-time responsiveness and process stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 900C30-0360-00 support redundancy?\u003c\/strong\u003e\u003cbr\u003eNo, the C30 is typically used in non-redundant systems. For redundancy, consider C70 or C75 controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is required for programming?\u003c\/strong\u003e\u003cbr\u003eHoneywell HC900 Process Designer software is required for configuration and programming.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all HC900 racks?\u003c\/strong\u003e\u003cbr\u003eYes, it installs into standard 900Rxx series racks (4, 8, or 12-slot configurations).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the product factory sealed?\u003c\/strong\u003e\u003cbr\u003eYes, supplied as 100% brand new, original equipment in factory packaging, ensuring full reliability.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49025481244924,"sku":"900C30-0360-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/900C30-0360-001.jpg?v=1776932114"}],"url":"https:\/\/www.electronicplc.com\/collections\/ge-multilin.oembed?page=2","provider":"Electronic PLC","version":"1.0","type":"link"}