{"title":"GE Multilin","description":"\u003cp\u003e\u003cspan\u003eThe GE Multilin series is the industry standard for power system protection and substation automation. This collection includes motor protection, feeder protection, and transformer relays designed to safeguard electrical assets from faults and operational anomalies. These devices are critical for integrating advanced monitoring and control within power distribution networks. Our Multilin inventory focuses on providing the necessary hardware to maintain power system reliability, supporting high-speed communications and precise protection logic to prevent costly equipment damage and unplanned outages in utility and industrial applications.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"ge-multilin-ur-6ch-digital-i-o-control-module","title":"GE Multilin UR 6CH Digital I\/O Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 6CH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital input\/output module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides additional binary I\/O points to monitor substation sensors, status contacts, and control signals, supporting deterministic performance for critical industrial applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 6CH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial substation automation and relay logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExpands digital control and feedback points in UR relay racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffloads I\/O management to streamline complex automation logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports precise control of switchgear and protection equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized for high-availability environments requiring consistent signal processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the UR 6CH interface with the relay system?\u003c\/strong\u003e\u003cbr\u003eIt connects to the UR internal backplane and is automatically recognized by the CPU for logic configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR 6CH compatible with all UR chassis versions?\u003c\/strong\u003e\u003cbr\u003eGenerally yes, but verify CPU firmware and rack revision to ensure full operational compatibility.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730356988,"sku":"UR6CH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-6fh-digital-i-o-control-module-ge-multilin","title":"UR 6FH Digital I\/O Control Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 6FH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital input\/output module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides reliable digital signaling for monitoring and control, enabling high-performance automation and protection in industrial substation environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eUR 6FH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Integration\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial substation automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed digital state detection and command execution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless integration within UR rack architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable via EnerVista UR for customized protection logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt to meet industrial standards for reliability and signal availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the I\/O points?\u003c\/strong\u003e\u003cbr\u003eUse EnerVista UR software to assign functions, monitor status, and run diagnostics for each channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with all UR relay chassis?\u003c\/strong\u003e\u003cbr\u003eGenerally yes, but verify your rack serial number and firmware version to ensure correct CPU recognition.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730389756,"sku":"UR67H","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8LH.jpg?v=1773216372"},{"product_id":"ur-8fh-analog-input-module-ge-multilin","title":"UR 8FH Analog Input Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8FH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a horizontal-format analog input module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides precise analog signal acquisition for monitoring electrical parameters, enabling the relay to execute real-time protection logic and maintain grid stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8FH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eHorizontal Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e40 mm × 185 mm × 172 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSubstation protection and measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Capabilities\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-precision analog signal acquisition for relay protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliable interface between primary sensors and relay CPU\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHorizontal layout for seamless integration into UR racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for industrial thermal and electromagnetic conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR 8FH hot-swappable?\u003c\/strong\u003e\u003cbr\u003eNo. Power must be removed from the UR rack before installing or replacing the module to protect the backplane and communication bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can I verify compatibility with my UR rack?\u003c\/strong\u003e\u003cbr\u003eCheck your relay chassis version and firmware against the UR 8FH specifications in the hardware manual to ensure proper fit and operation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730619132,"sku":"UR 8FH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH1.jpg?v=1773216372"},{"product_id":"ur-8hh-ct-vt-analog-input-module-ge-multilin","title":"UR 8HH CT VT Analog Input Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8HH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a dedicated analog measurement module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It interfaces with current and voltage transformers (CTs and VTs) to step down high-magnitude primary signals, providing precise 1A\/5A phase and ground current measurements.\u003c\/p\u003e\n\u003cp\u003eThis accuracy enables the relay to execute protective functions reliably and maintain power system stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8HH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003e3 × 1A\/5A phase CTs, 1 × 1A\/5A ground CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Integration\u003c\/td\u003e\n\u003ctd\u003eEnerVista UR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.16 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8HH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegrates seamlessly into the UR chassis, enabling high-fidelity data acquisition. Measurements can be displayed on the relay’s local LCD or exported via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor detailed analysis. The module supports customizable protection schemes, allowing engineers to set site-specific thresholds and monitor system conditions in real time while preserving signal integrity from field sensors to the relay CPU.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the UR 8HH be configured for different CT ratios?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports programmable CT\/VT scaling through\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e, allowing adaptation to various primary sensor ratings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eNo. Always de-energize the relay rack and follow lockout\/tagout procedures before inserting or removing the UR 8HH to prevent electrical hazards and bus communication errors.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730848508,"sku":"UR8HH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-9eh-cpu-processor-module-ge-multilin","title":"UR 9EH CPU Processor Module GE Multilin","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a core processing module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. Serving as the primary computational engine of the relay, the UR 9EH handles critical operations such as complex logic algorithms, latching sequences, and precise timing functions essential for power system protection.\u003c\/p\u003e\n\u003cp\u003eThe module is suitable for both upgrading legacy systems and replacing existing CPUs, ensuring reliable performance and integration within the UR platform.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eUR 9EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eCentral Processing Unit (CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturing Origin\u003c\/td\u003e\n\u003ctd\u003eMarkham, Ontario, Canada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e6.5 in × 6 in × 2.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIntegration and Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlug \u0026amp; Play functionality\u003c\/strong\u003e, allowing the system to auto-detect and initialize settings upon startup. To ensure operational stability and prevent errors such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHARDWARE MISMATCH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDSP ERROR\u003c\/strong\u003e, the CPU module generation must match the CT\/VT module generation.\u003c\/p\u003e\n\u003cp\u003eNew UR 9EH modules should be paired with modern CT\/VT counterparts, while legacy CPU modules should remain paired with older analog input modules to maintain communication integrity across the UR relay system.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Optimization\u003c\/h3\u003e\n\u003cp\u003eThe module is fully configurable through the relay’s front-panel keypad or via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e. Advanced users can optimize CPU performance by selectively disabling features, such as server scanning, which frees resources if\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 client\/server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication is not required in the network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older UR CPU with a new UR 9EH without updating other modules?\u003c\/strong\u003e\u003cbr\u003eCompatibility is version-dependent. Installing a new\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 9EH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealongside older CT\/VT modules may lead to communication errors. Always verify the compatibility of your existing backplane and I\/O modules before performing upgrades.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I free up resources on this CPU?\u003c\/strong\u003e\u003cbr\u003eThrough\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR\u003c\/strong\u003e, non-essential features like server scanning can be disabled to optimize CPU performance, especially if IEC 61850 communication is not being utilized in your specific system.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731012348,"sku":"UR9EH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH.jpg?v=1773216372"},{"product_id":"ur-rhh-ge-multilin-power-supply-module","title":"UR RHH GE Multilin Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized power supply module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It provides stable and regulated power to relay electronics, ensuring reliable operation of mission-critical protection and control functions in substation environments.\u003c\/p\u003e\n\u003cp\u003eWith robust construction and dependable DC\/AC conversion capabilities, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an essential component for maintaining continuous uptime and optimal performance within the UR relay architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries Compatibility\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR RHH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDC\/AC Power Input Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e40 mm × 225 mm × 292 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance and Reliability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to provide consistent voltage to internal relay components, preventing performance degradation or data errors during transient grid disturbances. Its compact, rack-mountable design allows easy integration into existing UR hardware assemblies, supporting efficient use of substation panel space.\u003c\/p\u003e\n\u003cp\u003eBuilt to withstand industrial thermal and electrical stresses, the module ensures reliable operation of UR relays even under challenging environmental conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UR RHH compatible with all Universal Relay (UR) chassis types?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR RHH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for the UR relay family; however, compatibility depends on the specific relay backplane version and the power requirements of connected CPU and modules. Always verify hardware specifications before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require cooling fans for operation?\u003c\/strong\u003e\u003cbr\u003eNo. The module is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econvection cooling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin standard UR relay housings. Ensure that the rack installation allows adequate airflow as recommended in the installation manual to maintain optimal operating temperatures.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731438332,"sku":"URRHH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR-RHH.jpg?v=1773212383"},{"product_id":"ur-8nh-ge-multilin-ct-vt-analog-input-module","title":"UR 8NH  GE Multilin CT VT Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized analog input module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. It delivers high-fidelity acquisition of current transformer (CT) and voltage transformer (VT) signals, enabling precise waveform monitoring and accurate data processing for advanced power system protection schemes.\u003c\/p\u003e\n\u003cp\u003eEngineered for critical electrical infrastructure, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacts as a key interface between field measurement devices and the relay’s central processing unit. With integrated diagnostic capabilities and high-resolution analog-to-digital conversion, the module ensures reliable signal acquisition for substation protection and automation applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eUR 8NH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eCT\/VT Analog Measurement Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eGE Multilin Universal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12.75 in × 10.50 in × 4.50 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Accuracy\u003c\/td\u003e\n\u003ctd\u003eHigh-precision analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eReal-time internal channel monitoring and self-test routines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Capabilities\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a critical interface between primary measurement sensors and the relay’s protection logic. By continuously monitoring internal channel performance, the module can quickly detect anomalies or hardware faults that may affect measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eIf a malfunction is detected, the system can automatically block associated protection trip commands, ensuring that protection actions are based only on verified and reliable measurement data. This safeguard helps prevent nuisance tripping and enhances the operational security of the power system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the UR 8NH require manual configuration after installation?\u003c\/strong\u003e\u003cbr\u003eYes. After installing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8NH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule, the relay must be configured using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista UR Setup\u003c\/strong\u003e. This configuration step maps CT and VT inputs to the appropriate protection elements within the relay logic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with older UR relay chassis models?\u003c\/strong\u003e\u003cbr\u003eCompatibility depends on the CPU firmware version and the backplane revision of the relay chassis. It is recommended to verify the rack serial number and firmware version against the module’s technical documentation before installation to ensure proper system integration.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746731962620,"sku":"UR8NH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8FH1.jpg?v=1773216372"},{"product_id":"ge-multilin-ur-8lh-analog-ct-vt-input-module","title":"GE Multilin UR 8LH Analog CT VT Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog input module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin Universal Relay Series\u003c\/strong\u003e. Designed for mission-critical substation automation, the module provides accurate acquisition of current transformer (CT) and voltage transformer (VT) signals, enabling reliable protection, monitoring, and measurement for electrical power systems.\u003c\/p\u003e\n\u003cp\u003eWith advanced signal conditioning and built-in diagnostics, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures stable data acquisition while supporting the protection logic of the relay system. Its robust construction and integrated monitoring functions help maintain system integrity in demanding utility and industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCT\/VT Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Series\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Supply\u003c\/td\u003e\n\u003ctd\u003e100–240 V AC, 50–60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Thermal Range\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm × 150 mm × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Capability\u003c\/td\u003e\n\u003ctd\u003eIntegrated self-monitoring for analog signal integrity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Interlocks\u003c\/td\u003e\n\u003ctd\u003eAutomatic fault-triggered alarm and protection blocking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates advanced diagnostic algorithms that continuously monitor the integrity of analog input channels. If a measurement anomaly or internal hardware issue is detected, the module automatically generates a system alarm and temporarily blocks associated relay trip outputs. This protective mechanism prevents false operations and enhances overall system safety.\u003c\/p\u003e\n\u003cp\u003eFor optimal performance, proper system integration requires verification of CPU firmware compatibility within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erack assembly. Ensuring firmware alignment allows the module to communicate effectively with other relay components and maintain accurate data processing across the protection system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable in a running UR chassis?\u003c\/strong\u003e\u003cbr\u003eIt is strongly recommended to de-energize the relay rack before inserting or removing the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR 8LH\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule. This precaution helps prevent electrical transients and avoids potential communication errors on the relay backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does this module handle sensor calibration?\u003c\/strong\u003e\u003cbr\u003eThe module supports digital calibration through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR configuration software suite\u003c\/strong\u003e, allowing engineers to adjust CT and VT ratio parameters during system commissioning to ensure accurate measurement and protection performance.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746732028156,"sku":"UR8LH","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/UR8LH.jpg?v=1773216372"},{"product_id":"ge-multilin-g60-generator-management-protection-relay","title":"GE Multilin G60 Generator Management Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a sophisticated protection and control terminal specifically engineered for the management of medium and large synchronous generators. It delivers a comprehensive suite of protection, monitoring, and control functions within a highly modular hardware architecture, ensuring maximum availability and reliability for critical power generation assets.\u003c\/p\u003e\n\u003cp\u003eAs part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e, the G60 combines advanced generator protection algorithms with integrated metering, disturbance recording, and flexible communication capabilities. This allows operators and engineers to maintain system stability while gaining deep insight into generator operating conditions and fault events.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Model\u003c\/td\u003e\n\u003ctd\u003eGE Multilin G60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Suite\u003c\/td\u003e\n\u003ctd\u003eDifferential, out-of-step, loss-of-field, stator ground fault, pole slip, overcurrent, and voltage-based protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Metering\u003c\/td\u003e\n\u003ctd\u003eReal-time monitoring of voltage, current, power, and energy parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Configuration\u003c\/td\u003e\n\u003ctd\u003eModular draw-out design available in single-bay and multi-bay formats\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eHigh-contrast menu-driven backlit LCD for local diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisturbance Analysis\u003c\/td\u003e\n\u003ctd\u003eAdvanced event and fault recording for post-event system analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in power generation facilities to protect synchronous generators and associated transformers. Its advanced generator-specific protection algorithms make it particularly valuable in thermal, hydroelectric, and combined-cycle power plants.\u003c\/p\u003e\n\u003cp\u003eBeyond traditional utility environments, the relay is also used in large industrial facilities for motor protection and control, as well as in renewable energy infrastructure such as wind and solar farms where generator protection and grid interconnection reliability are critical.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat makes the G60 suitable for power plants?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin G60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincorporates specialized protection algorithms designed specifically for generator operating conditions, including loss-of-field detection, pole-slip protection, and out-of-step protection—functions not typically available in standard protection relays.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the device support modern SCADA environments?\u003c\/strong\u003e\u003cbr\u003eYes. The relay supports multiple industry-standard communication protocols, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDNP3\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e, enabling seamless integration with modern SCADA and substation automation systems.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733043964,"sku":"G60","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/G601.jpg?v=1773212380"},{"product_id":"ge-multilin-t35-transformer-protection-relay-system","title":"GE Multilin T35 Transformer Protection Relay System","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a comprehensive three-phase transformer management relay engineered for the primary protection and monitoring of power transformer assets. This digital protection device integrates advanced protection algorithms with flexible automation capabilities, enabling high-speed fault detection and dependable operation in demanding electrical distribution environments.\u003c\/p\u003e\n\u003cp\u003eDesigned as part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin UR Series\u003c\/strong\u003e, the T35 provides sophisticated transformer differential protection, harmonic restraint, thermal monitoring, and event recording. These capabilities allow operators to maintain system stability while protecting valuable transformer infrastructure in both utility and industrial power networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Model\u003c\/td\u003e\n\u003ctd\u003eGE Multilin T35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Power Input\u003c\/td\u003e\n\u003ctd\u003e125 \/ 250 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input Channels\u003c\/td\u003e\n\u003ctd\u003e3 × 1A \/ 5A Phase CTs + 1 × 1A \/ 5A Ground CT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Input Channels\u003c\/td\u003e\n\u003ctd\u003e4 × 120V \/ 240V VTs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relay Ratings\u003c\/td\u003e\n\u003ctd\u003e24V DC to 250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in utility substations and industrial power systems where reliable transformer protection is critical. It is specifically designed to safeguard medium-to-large power transformers and supports advanced protection schemes such as transformer differential protection, harmonic blocking, and thermal overload monitoring.\u003c\/p\u003e\n\u003cp\u003eBy integrating multiple protection and monitoring functions into a single platform, the relay provides operators with a comprehensive view of transformer health, helping to minimize downtime and prevent catastrophic equipment failures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the T35 relay?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin T35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a dedicated transformer protection relay. It processes CT and VT inputs to detect internal faults, abnormal current conditions, and thermal overload situations, enabling fast and reliable tripping to protect critical power assets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the device suitable for extreme outdoor environments?\u003c\/strong\u003e\u003cbr\u003eYes. With an operating temperature range of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C to +85°C\u003c\/strong\u003e, the relay is engineered to operate reliably in harsh industrial and substation environments, including installations without climate-controlled enclosures.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733076732,"sku":"T35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/T35.jpg?v=1773212382"},{"product_id":"ge-multilin-f35-feeder-protection-relay","title":"GE Multilin F35 Feeder Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin F35\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efeeder protection relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to safeguard medium- and high-voltage distribution networks. Part of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUR (Universal Relay) family\u003c\/strong\u003e, it delivers advanced protection, control, and monitoring for feeders, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003earc-flash detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebreaker failure protection\u003c\/strong\u003e. Its modular architecture supports customizable I\/O configurations, making it ideal for complex industrial and utility substation applications.\u003c\/p\u003e\n\u003cp\u003eEngineered for digital substations, the F35 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-fidelity disturbance recording\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eevent logging\u003c\/strong\u003e, and robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 communication\u003c\/strong\u003e, enabling seamless integration into automated grid systems. Its intuitive interface and diagnostic tools enhance feeder management while reducing downtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eF35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFeeder Protection Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Protection Elements\u003c\/td\u003e\n\u003ctd\u003eOvercurrent, Voltage, Frequency, Directional Power, Breaker Failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Diagnostics\u003c\/td\u003e\n\u003ctd\u003eArc-Flash Detection, Waveform Capture, Sequence of Events (SOE) Recording\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, Modbus, DNP 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Architecture\u003c\/td\u003e\n\u003ctd\u003eUR (Universal Relay) Modular Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Interface\u003c\/td\u003e\n\u003ctd\u003eLarge graphical display for metering and status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eRole-based access control, security auditing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Arc-Flash Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh-speed light and current sensing reduces equipment damage and enhances personnel safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Scalability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFlexible UR platform allows expansion of I\/O boards for complex feeder requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Reporting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCOMTRADE-compliant disturbance and fault data for in-depth analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBuilt for consistent performance under extreme electrical and thermal conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the F35 support integration with IEC 61850 substations?\u003c\/strong\u003e\u003cbr\u003eYes, it is fully compliant with IEC 61850, supporting GOOSE messaging for fast protection and interoperability in digital substations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the F35 detect arc flashes?\u003c\/strong\u003e\u003cbr\u003eYes, the relay includes dedicated arc-flash detection logic. When paired with light-sensitive sensors, it delivers rapid response to clear arc faults in switchgear.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733142268,"sku":"F35","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F35-F53U04-HKH.jpg?v=1773133040"},{"product_id":"ge-multilin-239-an-h-motor-protection-relay","title":"GE Multilin 239-AN-H Motor Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin 239-AN-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicroprocessor-based motor protection relay\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for three-phase AC motors and their drive systems. Part of the 239 series, it provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomprehensive protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincluding thermal overload, phase unbalance, jam detection, undercurrent, and ground fault monitoring. The “-H” designation indicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eharsh environment conformal coating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor protection against moisture, dust, and chemical exposure.\u003c\/p\u003e\n\u003cp\u003eThe relay supports a wide AC\/DC supply range and connects to automation networks via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRS485 Modbus RTU\u003c\/strong\u003e, enabling remote monitoring and configuration. Its robust design helps prevent motor damage, reduce downtime, and extend asset life in demanding industrial settings.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e239-AN-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Elements\u003c\/td\u003e\n\u003ctd\u003eThermal Overload, Ground Fault, Phase Unbalance, Jam, Undercurrent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e70–265 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e30 W \/ 30 VA Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e10 A at 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS485 (Modbus RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eHarsh Environment Conformal Coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.81 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Operational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Inhibit Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrevents motor restart until thermal conditions are safe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal coating protects against dust, humidity, and corrosive conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRS485 enables remote monitoring and parameter adjustments via SCADA\/PLC systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProven Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSolid-state platform provides precise protection even in electrically noisy environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 239-AN-H require external hardware for ground fault protection?\u003c\/strong\u003e\u003cbr\u003eNo, the relay includes integrated ground fault protection, but CT configuration must match the motor circuit design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the communication port be used to program the relay settings?\u003c\/strong\u003e\u003cbr\u003eYes, the RS485 Modbus RTU port allows full remote configuration and status monitoring with compatible software.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746733633788,"sku":"239-AN","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/239-AN.jpg?v=1773126954"},{"product_id":"ge-multilin-m60-motor-protection-system-industrial-relay","title":"GE Multilin M60 Motor Protection System Industrial Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Multilin M60\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emotor protection system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emedium to large three-phase induction motors\u003c\/strong\u003e. It delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadvanced protection, control, and diagnostics\u003c\/strong\u003e, making it ideal for mission-critical industrial applications. The M60 features flexible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal overload models\u003c\/strong\u003e—standard, custom, and voltage-dependent—ensuring precise motor safeguarding under varied operating conditions.\u003c\/p\u003e\n\u003cp\u003eWith native\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIEC 61850 support\u003c\/strong\u003e, including SCL integration and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR-GOOSE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommunication, the system enables modern digital substation connectivity. Security is ensured with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-permission access controls\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand detailed command logging. Configuration is simplified through the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEnerVista M60 Autoconfigurator\u003c\/strong\u003e, and the system provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density programmable I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOMTRADE 2013-compliant waveform capture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor advanced disturbance analysis.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eMultilin M60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eMedium to large three-phase induction motor protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Curves\u003c\/td\u003e\n\u003ctd\u003eStandard, Custom, Voltage-dependent thermal models\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eIEC 61850, R-GOOSE, Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecording Standards\u003c\/td\u003e\n\u003ctd\u003eCOMTRADE 2013 (Waveform Capture)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecurity\u003c\/td\u003e\n\u003ctd\u003eDual-permission access, user command logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eFull-color, high-resolution interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eHigh-density programmable I\/O, flexible process bus support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFault and disturbance recording for in-depth post-event analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Configuration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAutoconfigurator reduces engineering time and streamlines logic deployment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModular Architecture:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eScalable I\/O to meet complex automation requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Security:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePermission-based access and command logging protect critical system changes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the M60 support IEC 61850 network integration?\u003c\/strong\u003e\u003cbr\u003eYes. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflexible process bus architectures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCL file integration\u003c\/strong\u003e, enabling seamless integration into modern digital substations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the M60 record waveform data for fault analysis?\u003c\/strong\u003e\u003cbr\u003eYes. The M60 provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCOMTRADE 2013-compliant waveform capture\u003c\/strong\u003e, facilitating detailed disturbance and fault event analysis.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746734387452,"sku":"M60","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/M601.jpg?v=1773130971"},{"product_id":"ge-multilin-469-p5-hi-a20-t-h-motor-management-relay","title":"GE Multilin 469-P5-HI-A20-T-H Motor Management Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e469-P5-HI-A20-T-H\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a microprocessor-based motor protection and management relay from the Multilin 469 series. It is designed for medium to large horsepower motors, providing comprehensive electrical and mechanical fault protection, advanced thermal modeling, and integrated diagnostics.\u003c\/p\u003e\n\u003cp\u003eThis configuration supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5A CT inputs\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-voltage control power\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efour programmable 4–20 mA outputs\u003c\/strong\u003e, making it suitable for high-voltage industrial control systems and SCADA integration. The conformal coating option ensures reliable operation in harsh environments with humidity or corrosive gases.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e469-P5-HI-A20-T-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMultilin 469 Motor Management System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Input (P5)\u003c\/td\u003e\n\u003ctd\u003e5 A Phase CT Secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power (HI)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC \/ 70–265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs (A20)\u003c\/td\u003e\n\u003ctd\u003e4 × isolated 4–20 mA (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Option (T)\u003c\/td\u003e\n\u003ctd\u003eConformal coating (harsh environment protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting (H)\u003c\/td\u003e\n\u003ctd\u003eHorizontal chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 × RS232 (front), 2 × RS485 (rear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eModbus RTU (up to 19.2 kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e12 × 100 Ω Platinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetering Functions\u003c\/td\u003e\n\u003ctd\u003eVoltage, Current, kW, kVAR, kVA, Energy, Demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H×W×D)\u003c\/td\u003e\n\u003ctd\u003e223.5 × 216.4 × 252.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThree-phase induction and synchronous motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-inertia loads requiring acceleration protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVFD-driven motor monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePumps, compressors, and fans in power, oil \u0026amp; gas, and heavy industry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the “T” option indicate?\u003c\/strong\u003e\u003cbr\u003eIt denotes conformal-coated internal PCBs for protection against moisture, chemicals, and H₂S exposure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used with 1A CTs?\u003c\/strong\u003e\u003cbr\u003eNo. The P5 variant is calibrated strictly for 5A CT secondaries. A 1A model variant is required for 1A CT systems.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746769383676,"sku":"469-P5-HI-A20","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/469-P5-HI-A20-T-H.jpg?v=1772092232"},{"product_id":"735-5-5-hi-485-ge-multilin-feeder-protection-relay","title":"735-5-5-HI-485 GE Multilin Feeder Protection Relay","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision feeder protection relay from the GE Multilin family. It is designed for the protection and monitoring of electrical distribution feeders in industrial and utility power systems.\u003c\/p\u003e\n\u003cp\u003eThis microprocessor-based relay combines instantaneous and time-delayed overcurrent protection with ground fault detection, ensuring reliable feeder protection and system stability. Although now discontinued, it remains an essential component for maintaining legacy switchgear and power monitoring infrastructures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e735-5-5-HI-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Protection\u003c\/td\u003e\n\u003ctd\u003e50\/51 Phase Overcurrent (Instantaneous and Time Delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSecondary Protection\u003c\/td\u003e\n\u003ctd\u003e50G\/51G Ground Fault (Instantaneous and Time Delay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply (HI)\u003c\/td\u003e\n\u003ctd\u003e90–300 VDC or 70–265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz auto-sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485 2-wire serial port (SCADA integration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl\u003c\/td\u003e\n\u003ctd\u003eDigital setpoint adjustment for trip curves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eTrue RMS current sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eDraw-out or fixed-mount relay housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e735-5-5-HI-485\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUtility substations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge industrial power distribution systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRetrofitted switchgear requiring RS485 SCADA integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFacilities with varying DC battery or AC auxiliary power sources\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt protects feeder circuits against short circuits, overloads, and ground faults while supporting remote monitoring and fault analysis.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 735-5-5-HI-485 still in production?\u003c\/strong\u003e\u003cbr\u003eNo. The model is discontinued by the manufacturer but remains available as refurbished or surplus units to support legacy installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does “5-5” indicate in the model number?\u003c\/strong\u003e\u003cbr\u003eThe “5-5” designation signifies compatibility with 5 A Phase and 5 A Ground current transformer secondary inputs, ensuring standard CT integration for feeder protection.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746788356348,"sku":"735-5-5-HI-485","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/735-5-5-HI-485.jpg?v=1770948453"},{"product_id":"spso2-surge-protection-module-abb","title":"SPSO2 Surge Protection Module ABB","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPSO2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Part Number:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPSO2\u003c\/strong\u003e) is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance surge protective device (SPD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom ABB, specifically designed to safeguard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSymphony Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems and sensitive industrial electronics against transient overvoltages. This module protects equipment from atmospheric surges (e.g., lightning) and internal switching transients, preventing costly downtime and hardware damage in critical automation environments.\u003c\/p\u003e\n\u003cp\u003eWith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efast response time of \u0026lt;25 ns\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand high discharge capacity, the SPSO2 ensures that surges are clamped before they reach delicate silicon components. Its compact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e36 mm DIN-rail mount\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehousing is ideal for high-density cabinets, providing robust protection without consuming excessive space. Built for harsh industrial environments, the SPSO2 combines reliability, ease of installation, and long-term operational stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eSPSO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Continuous Operating Voltage (MCOV)\u003c\/td\u003e\n\u003ctd\u003e320 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Discharge Current (In, 8\/20 μs)\u003c\/td\u003e\n\u003ctd\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Discharge Current (Imax, 8\/20 μs)\u003c\/td\u003e\n\u003ctd\u003e40 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Protection Level (Up)\u003c\/td\u003e\n\u003ctd\u003e≤ 1.8 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 25 ns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current Rating (SCCR)\u003c\/td\u003e\n\u003ctd\u003e25 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Capacity\u003c\/td\u003e\n\u003ctd\u003e2.5 mm² to 35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e90 mm x 36 mm x 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e1.24 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRapid Surge Clamping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSub-25 ns response protects sensitive electronics before damage occurs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Discharge Capacity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHandles up to 40 kA for indirect lightning and switching surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Design:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e36 mm DIN-rail footprint allows dense enclosure installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Terminals:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAccommodates cable sizes from 2.5 mm² to 35 mm².\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWide -40°C to +80°C operating range for harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaintenance-Friendly:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20, finger-safe design with visual end-of-life indicator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProtects turbine controllers, governors, and sensor electronics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater \u0026amp; Wastewater:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShields PLCs, I\/O modules, and instrumentation from voltage spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeavy Manufacturing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGuards automation cabinets in metal processing, pulp \u0026amp; paper, and chemical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know if the SPSO2 has reached end of life?\u003c\/strong\u003e\u003cbr\u003eThe module features a visual status window. A color change (usually green → red) indicates that the internal protection components have been used and the unit must be replaced.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SPSO2 protect against direct lightning strikes?\u003c\/strong\u003e\u003cbr\u003eIt is rated for indirect lightning and switching surges up to 40 kA (8\/20 μs). For direct strikes, the SPSO2 should be part of a coordinated Type 1 lightning protection system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module easy to install in crowded cabinets?\u003c\/strong\u003e\u003cbr\u003eYes. Its 36 mm width (2-module DIN size) and standard screw terminals allow space-efficient, secure installation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48746791010556,"sku":"SPS02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SPS02_d8e0aff4-3f14-487e-bb2d-41a5ca823cc9.jpg?v=1770621502"},{"product_id":"900c30-0360-00-honeywell-hc900-c30","title":"900C30-0360-00 Honeywell HC900 C30","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 900C30-0360-00 serves as the primary processing engine of the ControlEdge HC900 hybrid control system. This CPU module executes advanced control strategies—including PID loops and logic sequencing—while managing communication between the controller and distributed I\/O racks. It acts as the central “brain” of the system, delivering reliable performance for both discrete and process control applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e900C30-0360-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction Blocks\u003c\/td\u003e\n\u003ctd\u003eUp to 400 blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Capacity\u003c\/td\u003e\n\u003ctd\u003e96 Universal \/ 192 High Level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Capacity\u003c\/td\u003e\n\u003ctd\u003e40 Standard \/ up to 192 (external power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 384 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e137 × 35.6 × 137.16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHybrid Control Efficiency\u003c\/strong\u003e\u003cbr\u003eCombines PLC-style discrete logic and DCS-level process control in a single CPU, eliminating the need for separate systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision PID Execution\u003c\/strong\u003e\u003cbr\u003eSupports up to 400 function blocks, enabling complex control strategies such as cascade and ratio control without compromising performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Processing Power\u003c\/strong\u003e\u003cbr\u003eLightweight and space-efficient design delivers high I\/O handling capacity, ideal for skid systems and compact control panels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless I\/O Integration\u003c\/strong\u003e\u003cbr\u003eEnsures fast communication with local and remote I\/O racks, maintaining real-time responsiveness and process stability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 900C30-0360-00 support redundancy?\u003c\/strong\u003e\u003cbr\u003eNo, the C30 is typically used in non-redundant systems. For redundancy, consider C70 or C75 controllers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat software is required for programming?\u003c\/strong\u003e\u003cbr\u003eHoneywell HC900 Process Designer software is required for configuration and programming.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all HC900 racks?\u003c\/strong\u003e\u003cbr\u003eYes, it installs into standard 900Rxx series racks (4, 8, or 12-slot configurations).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the product factory sealed?\u003c\/strong\u003e\u003cbr\u003eYes, supplied as 100% brand new, original equipment in factory packaging, ensuring full reliability.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49025481244924,"sku":"900C30-0360-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/900C30-0360-001.jpg?v=1776932114"},{"product_id":"369-hi-r-0-0-0-0-e-ge-multilin-motor-management-relay","title":"General Electric Multilin 369-HI-R-0-0-0-0-E Motor Management Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric Multilin 369-HI-R-0-0-0-0-E is a high-performance motor management relay designed to provide comprehensive protection, monitoring, and diagnostics for medium-voltage and low-voltage motors. As part of the 369 series, this unit is engineered to prevent motor damage by monitoring critical parameters such as thermal capacity, current, and temperature, ensuring reliable operation in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAdvanced motor protection with enhanced diagnostics and an integrated enhanced faceplate for local monitoring.\u003c\/li\u003e\n\u003cli\u003eSupports 12 RTD inputs for precise temperature monitoring of motor windings and bearings.\u003c\/li\u003e\n\u003cli\u003eWide input power range: 50-300 VDC or 60-265 VAC (50-60 Hz).\u003c\/li\u003e\n\u003cli\u003eFlexible current sensing supporting both 1 A and 5 A secondary phase current inputs.\u003c\/li\u003e\n\u003cli\u003eGround current input frequency range of 20 to 100 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-R-0-0-0-0-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMotor Management Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power\u003c\/td\u003e\n\u003ctd\u003e50-300 VDC \/ 60-265 VAC (50-60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Inputs\u003c\/td\u003e\n\u003ctd\u003e12 Inputs (3-wire: 100 Ohm Pt, 100 Ohm Ni, 120 Ohm Ni, 10 Ohm Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Current Input\u003c\/td\u003e\n\u003ctd\u003e1 A and 5 A secondary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround Current Frequency\u003c\/td\u003e\n\u003ctd\u003e20 to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Fuse\u003c\/td\u003e\n\u003ctd\u003e3.15 A H 250 V (5 x 20 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +60 degC (-40 degF to +140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the device is powered down before performing any wiring or installation tasks.\u003c\/li\u003e\n\u003cli\u003eMount the relay in a clean, dry, and vibration-free environment, ensuring adequate clearance for cooling airflow.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cables for communication and sensor inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eVerify that all RTD connections are secure and properly configured for the specific sensor type (Pt, Ni, or Cu) to avoid measurement errors.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) handling procedures when accessing internal components or the fuse.\u003c\/li\u003e\n\u003cli\u003eEnsure the chassis is properly grounded to the control panel earth bus to maintain signal integrity and safety.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 369-HI-R-0-0-0-0-E?\u003c\/h3\u003e\u003cp\u003eThis relay is designed to protect motors from thermal overload, phase imbalance, and other electrical faults while providing real-time monitoring of motor temperature via 12 RTD inputs.\u003c\/p\u003e\u003ch3\u003eWhat types of RTD sensors are compatible with this relay?\u003c\/h3\u003e\u003cp\u003eThe unit supports 3-wire 100 Ohm platinum, 100 Ohm nickel, 120 Ohm nickel, and 10 Ohm copper RTD sensors.\u003c\/p\u003e\u003ch3\u003eIs the internal fuse field-replaceable?\u003c\/h3\u003e\u003cp\u003eYes, the unit utilizes a standard 3.15 A H 250 V (5 x 20 mm) fuse which can be accessed for maintenance if required.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50641862000892,"sku":"369-HI-R-0-0-0-0-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_409702eb-3e37-4ea7-bc45-91e104a107f8.jpg?v=1784887123"},{"product_id":"ge-is200tturh1b-mark-vi-turbine-protection-input-terminal-board","title":"General Electric IS200TTURH1B Mark VIe Turbine Termination Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IS200TTURH1B is a termination board designed for use within the Mark VIe control system, specifically engineered for turbine control applications. This printed circuit board serves as a critical interface component, facilitating the connection between field wiring and the control system I\/O modules. As a component of the Mark VIe series, it ensures reliable signal processing and distribution for turbine-related monitoring and control functions.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for integration with Mark VIe turbine control systems.\u003c\/li\u003e\n\u003cli\u003eProvides robust termination points for field-level turbine instrumentation.\u003c\/li\u003e\n\u003cli\u003eSupports high-frequency MPU (Magnetic Pickup) pulse inputs.\u003c\/li\u003e\n\u003cli\u003eEngineered for high-reliability industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis termination board is utilized in power generation and industrial turbine management systems. It is primarily used to interface with speed sensors, shaft voltage monitoring equipment, and other critical turbine instrumentation requiring precise signal acquisition and termination within the Mark VIe architecture.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIS200TTURH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eTurbine Termination Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPU Pulse Rate Range\u003c\/td\u003e\n\u003ctd\u003e2 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e125 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input\u003c\/td\u003e\n\u003ctd\u003e200 to 230 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure all power is disconnected from the rack and associated field wiring before attempting installation or removal of the board.\u003c\/li\u003e\n\u003cli\u003eHandle the PCB using proper ESD (Electrostatic Discharge) mitigation techniques to prevent damage to sensitive electronic components.\u003c\/li\u003e\n\u003cli\u003eVerify that the board is correctly seated in the designated slot within the Mark VIe cabinet and that all terminal connections are tightened to the specified torque.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage power lines and sources of electromagnetic interference (EMI) to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation within the control cabinet to maintain operating temperatures within the manufacturer's specified limits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the IS200TTURH1B still being manufactured?\u003c\/h3\u003e\u003cp\u003eNo, this model has been discontinued by the manufacturer. We provide high-quality replacement units to support legacy Mark VIe systems.\u003c\/p\u003e\u003ch3\u003eWhat is the primary function of this board?\u003c\/h3\u003e\u003cp\u003eThe IS200TTURH1B acts as a termination interface, allowing field sensors and turbine devices to connect to the Mark VIe control system I\/O, specifically handling MPU inputs and shaft voltage monitoring.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50646857810172,"sku":"IS200TTURH1B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_10ee96b1-4a22-4b30-9929-04739d9a0977.jpg?v=1785046818"},{"product_id":"369-hi-r-m-0-0-h-e-ge-multilin-369-series-motor-management-relay","title":"GE Multilin 369-HI-R-M-0-0-H-E Motor Management Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Multilin 369-HI-R-M-0-0-H-E is a high-performance motor protection and management relay designed for the comprehensive safeguarding of medium-sized motors. By utilizing advanced adaptive learning algorithms, the relay calibrates protection parameters based on specific motor performance profiles. This unit is widely deployed in demanding industrial environments, including oil refineries, power plants, and mining operations, where it serves to minimize unplanned downtime through predictive fault detection and detailed operational data logging.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdaptive Protection:\u003c\/strong\u003e Utilizes intelligent algorithms to tailor protection settings to individual motor characteristics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics:\u003c\/strong\u003e Tracks energy consumption (MWh), total motor starts, and cumulative running hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Analysis:\u003c\/strong\u003e Includes waveform capture and event recording triggered by power failures, alarms, or self-test routines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Equipped with a non-isolated RS232 port and a high-speed RS485 port supporting Modbus RTU for SCADA integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Speed Switching:\u003c\/strong\u003e Features differential switching with a time delay of less than 200 ms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 369 series is engineered for critical motor control applications, providing essential protection against thermal overload, current imbalance, and phase-related faults. It is suitable for integration into medium-voltage and low-voltage motor control centers (MCCs) in heavy industrial sectors.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e369-HI-R-M-0-0-H-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Multilin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Input\u003c\/td\u003e\n\u003ctd\u003e110-250 VDC \/ 100-240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifferential Switch Delay\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 200 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS232, RS485 (Modbus RTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the unit is mounted in a clean, dry environment with adequate clearance for ventilation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Always connect the chassis ground terminal to a reliable earth ground to ensure proper EMI\/RFI shielding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted-pair cabling for RS485 communication lines to prevent signal interference. Ensure all power connections are tightened to the specified torque values provided in the manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Isolate all power sources before performing installation, wiring, or maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling:\u003c\/strong\u003e Use standard electrostatic discharge (ESD) precautions when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat communication protocols does the 369-HI-R-M-0-0-H-E support?\u003c\/h3\u003e\u003cp\u003eThe unit supports serial communication via RS232 and RS485 ports, utilizing the Modbus RTU protocol for integration with external SCADA or PLC systems.\u003c\/p\u003e\u003ch3\u003eIs this relay suitable for high-temperature environments?\u003c\/h3\u003e\u003cp\u003eThe relay is rated for an operating temperature range of -40 deg C to +60 deg C, making it suitable for most industrial environments, though it should not be installed in areas exceeding these limits without proper climate control.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50708681916668,"sku":"369-HI-R-M-0-0-H-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_6c0021d3-40ca-4fcc-a762-d9c8a0fbe8ed.jpg?v=1785135318"},{"product_id":"750-p5-g5-s5-hi-a20-r-e-ge-grid-solutions-750-series-feeder-management-relay","title":"GE Grid Solutions 750-P5-G5-S5-HI-A20-R-E Feeder Management Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe 750-P5-G5-S5-HI-A20-R-E is a high-performance, microprocessor-based feeder management relay from the GE Grid Solutions 750\/760 series. This unit is engineered to provide comprehensive primary and backup protection for critical power infrastructure, including buses, transformers, and transmission lines. By utilizing a dual-processor architecture, the relay ensures high-speed signal processing and reliable fault detection, serving as a central control hub for utility and heavy industrial power distribution systems.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-processor architecture featuring a 32-bit Motorola 68332 for protection algorithms and a 16-bit Intel 80C186 for communication and auxiliary I\/O management.\u003c\/li\u003e\n\u003cli\u003eEight programmable 4-20 mA analog outputs for flexible system integration and monitoring.\u003c\/li\u003e\n\u003cli\u003eComprehensive current sensing inputs (5 A) covering phase, zero-sequence, and sensitive ground fault detection.\u003c\/li\u003e\n\u003cli\u003eEnhanced LCD display and dedicated LED status indicators, including a \"Breaker Closed\" visual confirmation.\u003c\/li\u003e\n\u003cli\u003eWide-range power supply compatibility supporting both high-voltage AC and DC inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis relay is designed for demanding environments such as power plants, substations, and large-scale industrial grids where high-speed fault protection and system monitoring are required to minimize downtime and protect expensive electrical assets.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e750-P5-G5-S5-HI-A20-R-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Grid Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e750\/760 Feeder Management Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e8 x 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Inputs\u003c\/td\u003e\n\u003ctd\u003e5 A (Phase, Zero-Sequence, Sensitive Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Range\u003c\/td\u003e\n\u003ctd\u003e88-300 VDC \/ 70-265 VAC (48-62 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the unit is mounted in a standard 19-inch rack (4U height) with adequate clearance for ventilation.\u003c\/li\u003e\n\u003cli\u003eVerify that all current and voltage inputs are correctly wired according to the terminal diagram provided in the product manual.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for communication and analog output signals to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure the chassis is properly grounded to the cabinet earth bus to maintain protection integrity.\u003c\/li\u003e\n\u003cli\u003eAlways disconnect power before inserting or removing the relay from the rack to prevent electrical damage or unexpected operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 750-P5-G5-S5-HI-A20-R-E?\u003c\/h3\u003e\u003cp\u003eThis relay provides primary and backup protection for feeders, transformers, and busbars, utilizing advanced protection logic to detect faults and trigger necessary control actions.\u003c\/p\u003e\u003ch3\u003eDoes this unit support remote communication?\u003c\/h3\u003e\u003cp\u003eYes, the relay is designed with communication capabilities managed by the internal 16-bit processor, allowing for integration into broader SCADA or plant control systems.\u003c\/p\u003e\u003ch3\u003eWhat is the operating temperature range?\u003c\/h3\u003e\u003cp\u003eThe unit is rated for operation in environments ranging from -40 to 60 deg C, making it suitable for harsh industrial conditions.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50733863633148,"sku":"750-P5-G5-S5-HI-A20-R-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3f389a99-7d52-4c05-af54-008bbf261a07.jpg?v=1785284067"},{"product_id":"ge-mark-vi-is200vturh1bac-primary-turbine-protection-board","title":"GE Mark VI IS200VTURH1BAC Primary Turbine Protection Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IS200VTURH1BAC is a specialized Primary Turbine Protection module designed for the GE Speedtronic Mark VI Turbine Control System. Functioning as the core VTUR board, it provides high-integrity monitoring and trip logic for large-scale utility turbines in power generation and heavy industrial applications. The board executes critical safety functions, including primary overspeed detection via passive pulse rate devices, shaft voltage\/current monitoring, and automatic generator synchronization. By integrating emergency trip solenoid control with precision speed sensing, this module is essential for preventing catastrophic turbine failure and minimizing unscheduled downtime in high-stakes environments like thermal power plants and petrochemical facilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports seamless integration with TRPG, TRPL, TREG, and TRPS terminal boards for signal distribution and solenoid driving.\u003c\/li\u003e\n\u003cli\u003eUtilizes four passive pulse rate inputs to monitor turbine rotation for primary overspeed trip execution.\u003c\/li\u003e\n\u003cli\u003eIncludes hardware-level logic for automatic generator synchronizing and circuit breaker control.\u003c\/li\u003e\n\u003cli\u003eFeatures dual-threshold contact voltage sensing (20 VDC HI \/ 6 VDC LO) for signal reliability in industrial electrical environments.\u003c\/li\u003e\n\u003cli\u003eDedicated hardware channels for emergency trip solenoid control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is specifically engineered for use within the GE Mark VI Speedtronic control architecture. It is typically deployed in power generation facilities, thermal power plants, and large-scale petrochemical processing plants where turbine overspeed protection and precise synchronization are mission-critical requirements.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VTURH1BAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eTurbine Specific Primary Trip Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPU Pulse Rate Range\u003c\/td\u003e\n\u003ctd\u003e2 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse Rate Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.05% of Reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Solenoid Outputs\u003c\/td\u003e\n\u003ctd\u003e3 Dedicated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Voltage Sensing\u003c\/td\u003e\n\u003ctd\u003e20 VDC (HI) \/ 6 VDC (LO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the Mark VI control rack is powered down before inserting or removing the VTUR board to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) protection measures to avoid damaging sensitive internal components.\u003c\/li\u003e\n\u003cli\u003eEnsure the board is fully seated in the VME-style backplane slot and that all retaining screws are tightened to ensure proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eVerify that all terminal board connections (TRPG, TRPL, TREG, TRPS) are correctly wired and secured before system startup.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation within the control cabinet to maintain operating temperatures between 0 and 60 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IS200VTURH1BAC?\u003c\/h3\u003e\u003cp\u003eThe IS200VTURH1BAC acts as the primary turbine protection board in the Mark VI system, responsible for monitoring turbine speed, executing overspeed trips, and managing generator synchronization.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other terminal boards?\u003c\/h3\u003e\u003cp\u003eYes, the VTUR board is designed to interface with specific Mark VI terminal boards, including the TRPG, TRPL, TREG, and TRPS, to facilitate signal distribution and solenoid control.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50734367801596,"sku":"IS200VTURH1BAC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_7281c577-cb83-432a-806a-0fd97b2bdc12.jpg?v=1785308274"},{"product_id":"is200vturh1baa-general-electric-mark-vi-primary-turbine-protection-card","title":"GE Fanuc IS200VTURH1BAA Mark VI Primary Turbine Protection Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IS200VTURH1BAA is a Primary Turbine Protection Card designed for the GE Speedtronic Mark VI control system. This module plays a critical role in turbine safety by executing autonomous trip logic to prevent mechanical damage. It monitors turbine-specific parameters in real-time, facilitating rapid emergency shutdowns when safety thresholds are exceeded. The card is engineered for high-reliability applications, including thermal power plants, gas turbine installations, and heavy industrial refineries, ensuring asset protection and operational continuity.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Designed specifically for the Mark VI VME-style control rack architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Logic:\u003c\/strong\u003e Executes deterministic, high-speed trip logic isolated from non-critical control functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRevision Structure:\u003c\/strong\u003e Features a three-fold revision configuration (Rating B, A, and artwork A) for enhanced reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Maintains full backward compatibility with earlier iterations of the VTUR series, supporting seamless drop-in replacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing Quality:\u003c\/strong\u003e Produced as a standard assembly, meeting rigorous industrial quality standards for critical control hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is utilized in GE Speedtronic Mark VI control systems for:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGas turbine emergency overspeed protection.\u003c\/li\u003e\n\u003cli\u003eThermal power plant turbine safety monitoring.\u003c\/li\u003e\n\u003cli\u003eHeavy industrial refinery rotating equipment protection.\u003c\/li\u003e\n\u003cli\u003eCritical trip loop management in power generation facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200VTURH1BAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VI Speedtronic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePrimary Turbine Protection Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRevision\u003c\/td\u003e\n\u003ctd\u003eB, A, A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAssembly Type\u003c\/td\u003e\n\u003ctd\u003eNormal Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eMark VI VME-style racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Always use an anti-static wrist strap and grounded work surface when handling the PCB to prevent damage to sensitive electronic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Ensure the control rack is powered down or the specific slot is isolated before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeating:\u003c\/strong\u003e Ensure the card is fully seated in the VME backplane connector and that the front panel locking levers are securely engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain the cabinet environment within the specified 0 to 60 deg C range and ensure adequate ventilation to prevent thermal degradation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the rack chassis is properly grounded to mitigate EMI and ensure signal integrity for protection loops.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the IS200VTURH1BAA compatible with older VTUR boards?\u003c\/h3\u003e\u003cp\u003eYes, this module is engineered for backward compatibility with the first two iterations of the VTUR series, allowing for drop-in replacement in legacy Mark VI racks.\u003c\/p\u003e\u003ch3\u003eWhat is the primary function of this card?\u003c\/h3\u003e\u003cp\u003eThe card serves as a primary turbine protection module, responsible for monitoring critical turbine parameters and triggering emergency shutdowns to prevent mechanical failure.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50734394704124,"sku":"IS200VTURH1BAA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_741c1d1d-fb68-4635-af9f-db4775618a7c.jpg?v=1785309616"},{"product_id":"general-electric-multilin-sr489-case-489-p5-hi-a20-e-generator-management-relay","title":"General Electric Multilin SR489-CASE 489-P5-HI-A20-E Generator Management Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric Multilin 489-P5-HI-A20-E is a microprocessor-based generator management relay engineered for the comprehensive protection, control, and monitoring of small to medium-sized generators. As a key component of the SR family, it provides advanced features such as generator stator differential protection and detailed diagnostic logging to minimize troubleshooting time. This unit features a draw-out construction, allowing for efficient maintenance and reduced system downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eComprehensive generator protection including stator differential, reverse power, overexcitation, and inadvertent energization.\u003c\/li\u003e\n\u003cli\u003eEnhanced display unit for improved local monitoring and setpoint management.\u003c\/li\u003e\n\u003cli\u003eSupports RTD and analog inputs for monitoring critical parameters like bearing temperature and vibration.\u003c\/li\u003e\n\u003cli\u003eIntegrated waveform capture, event recording, and data logging capabilities.\u003c\/li\u003e\n\u003cli\u003eCommunication support via RS232, RS485, and Modbus protocols.\u003c\/li\u003e\n\u003cli\u003eBuilt-in waveform simulation tools for setpoint verification.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePrimary and backup protection for industrial power generation systems.\u003c\/li\u003e\n\u003cli\u003eSynchronization and protection management in cogeneration plants.\u003c\/li\u003e\n\u003cli\u003eCritical monitoring for high-demand industrial power environments.\u003c\/li\u003e\n\u003cli\u003eStator and bearing temperature monitoring for generator health diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSR489-CASE 489-P5-HI-A20-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE Multilin)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase Current Inputs\u003c\/td\u003e\n\u003ctd\u003e5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power\u003c\/td\u003e\n\u003ctd\u003e90-300 VDC \/ 70-265 VAC (48-62 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEFT Standard\u003c\/td\u003e\n\u003ctd\u003eIEEE\/ANSI C37.90.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImpulse Voltage Withstand\u003c\/td\u003e\n\u003ctd\u003e5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3rd Harmonic Timing Accuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 3.0 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the device is installed in a clean, dry environment protected from excessive vibration and extreme temperatures.\u003c\/li\u003e\n\u003cli\u003eVerify that the control power supply matches the 90-300 VDC or 70-265 VAC rating before energizing.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables for RS485 connections to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eThe unit utilizes a draw-out design; ensure the chassis is properly seated and locked to maintain electrical continuity.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing the relay module from the rack to prevent electrical arcing or damage to internal components.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions when handling the module internals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the 489-P5-HI-A20-E?\u003c\/h3\u003e\u003cp\u003eThe GE Multilin 489-P5-HI-A20-E is a microprocessor-based generator management relay designed for protecting, controlling, and monitoring small to medium-sized generators.\u003c\/p\u003e\u003ch3\u003eWhat is the function of the 489-P5-HI-A20-E?\u003c\/h3\u003e\u003cp\u003eIt offers complete generator protection, including stator thermal protection, bearing over-temperature monitoring, and negative sequence overcurrent for rotor protection.\u003c\/p\u003e\u003ch3\u003eHow do I view metered values?\u003c\/h3\u003e\u003cp\u003eMetered values (voltage, current, power) are available on the front panel display or via communication ports.\u003c\/p\u003e\u003ch3\u003eDoes the relay support 4-wire RS485?\u003c\/h3\u003e\u003cp\u003eNo, the 489-P5-HI-A20-E communicates only in 2-wire half-duplex mode.\u003c\/p\u003e\u003ch3\u003eWhat are the analog output ranges?\u003c\/h3\u003e\u003cp\u003eThe analog outputs are 4 to 20 mA.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50879660622076,"sku":"SR489-CASE 489-P5-HI-A20-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c61477e8-8c3e-4b11-a630-ee75ee657c33.jpg?v=1785584307"},{"product_id":"general-electric-multilin-ur7hh-communications-module","title":"General Electric Multilin UR7HH Inter-Relay Communications Module","description":"\u003cp\u003eThe General Electric UR7HH is a high-performance inter-relay communications module designed for the Universal Relay (UR) series. This horizontal unit facilitates robust data exchange between protection relays, utilizing multi-mode fiber optic technology to ensure reliable communication in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTwo independent, full-duplex communication channels.\u003c\/li\u003e\n\u003cli\u003e820 nm multi-mode fiber optic interface for long-distance, noise-immune connectivity.\u003c\/li\u003e\n\u003cli\u003eStandard ST-type fiber optic connectors for secure physical termination.\u003c\/li\u003e\n\u003cli\u003eOptical galvanic isolation rated at 2 kV to protect internal circuitry from ground loops and electrical surges.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range suitable for harsh substation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eUR7HH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eUniversal Relay (UR) Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Channels\u003c\/td\u003e\n\u003ctd\u003e2 Independent Full-Duplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eMulti-mode (62.5\/125 µm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e820 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eST Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e64 kbps to 512 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2 kV Optical Galvanic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack-plane Supply\u003c\/td\u003e\n\u003ctd\u003e+5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +95 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the UR relay is powered down before inserting or removing the UR7HH module from the back-plane.\u003c\/li\u003e\n\u003cli\u003eHandle the module by the edges to avoid electrostatic discharge (ESD) damage to sensitive internal components.\u003c\/li\u003e\n\u003cli\u003eEnsure fiber optic cables are routed with appropriate bend radii to prevent signal attenuation or fiber breakage.\u003c\/li\u003e\n\u003cli\u003eVerify that ST connectors are clean and properly seated before locking them into the module ports.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for horizontal mounting within the UR chassis; ensure the mounting screws are tightened to maintain proper grounding and structural integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat type of fiber optic cable is compatible with the UR7HH?\u003c\/h3\u003e\u003cp\u003eThe module is designed for 62.5\/125 µm multi-mode fiber optic cables using standard ST connectors.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eNo, the UR7HH draws its required +5 V DC power directly from the Universal Relay back-plane.\u003c\/p\u003e\u003ch3\u003eWhat is the primary application for this module?\u003c\/h3\u003e\u003cp\u003eThis module is primarily used for inter-relay communication, allowing protection relays to share data for schemes such as differential protection or interlocking in power distribution systems.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50957121487100,"sku":"UR7HH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_1100a183-c779-4f14-a897-89d7151e2290.jpg?v=1786329021"},{"product_id":"general-electric-mark-vie-is200tturh1bcc-termination-board","title":"General Electric IS200TTURH1BCC Mark VIe Turbine Termination Board","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IS200TTURH1BCC is a termination board designed for the General Electric Mark VIe control system. This component is specifically engineered for turbine control applications, providing essential signal termination and interface capabilities for turbine-related instrumentation and sensors. As part of the Mark VIe series, it supports high-reliability operation in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for turbine device interface and signal management.\u003c\/li\u003e\n\u003cli\u003eUtilizes surface mount technology for compact and reliable circuit integration.\u003c\/li\u003e\n\u003cli\u003eSupports a wide MPU pulse rate range for precise turbine speed monitoring.\u003c\/li\u003e\n\u003cli\u003eRobust operating temperature range suitable for industrial control cabinets.\u003c\/li\u003e\n\u003cli\u003eDirectly compatible with Mark VIe system architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIS200TTURH1BCC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark VIe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eTurbine Termination Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e125 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShaft Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPU Pulse Rate Range\u003c\/td\u003e\n\u003ctd\u003e2 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTechnology\u003c\/td\u003e\n\u003ctd\u003eSurface Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before installing or removing the termination board to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eHandle the board using proper ESD (Electrostatic Discharge) protection protocols to avoid damaging sensitive surface-mount components.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring is properly secured to the terminal blocks and that connections match the system wiring diagrams.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation within the cabinet to maintain the operating temperature within the specified -30 to 65 degC range.\u003c\/li\u003e\n\u003cli\u003eCheck that the board is correctly seated in the rack or mounting assembly before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IS200TTURH1BCC?\u003c\/h3\u003e\u003cp\u003eThe IS200TTURH1BCC acts as a termination board for turbine devices within the Mark VIe control system, managing signal inputs and providing the necessary interface for turbine monitoring and control.\u003c\/p\u003e\u003ch3\u003eIs this board compatible with older Mark VI systems?\u003c\/h3\u003e\u003cp\u003eThe IS200TTURH1BCC is specifically designed for the Mark VIe series. Please consult your system documentation or technical manual to ensure compatibility with your specific controller configuration.\u003c\/p\u003e\u003ch3\u003eWhat is the required power supply for this module?\u003c\/h3\u003e\u003cp\u003eThis termination board is designed to operate with a 125 V dc power supply.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50973686890748,"sku":"IS200TTURH1BCC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_7d91f495-875f-4891-b8ab-bb08750e3eac.jpg?v=1786594621"},{"product_id":"general-electric-multilin-750-p5-g5-hi-a1-r-e-feeder-management-relay","title":"General Electric Multilin 750-P5-G5-HI-A1-R-E Feeder Management Relay","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric Multilin 750-P5-G5-HI-A1-R-E is a high-performance Feeder Management Relay from the SR750 series. Designed for the protection, control, and monitoring of electrical distribution feeders, this relay provides comprehensive protection features for industrial and utility power systems. It features advanced metering capabilities and flexible communication options to ensure reliable operation in demanding electrical environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePhase current input: 5 Amp\u003c\/li\u003e\n\u003cli\u003eGround current input: 5 Amp Zero Sequence\u003c\/li\u003e\n\u003cli\u003eSensitive current input: 5 Amp\u003c\/li\u003e\n\u003cli\u003eWide range power supply: 80-300 V DC or 70-265 V AC (48\/62 Hz)\u003c\/li\u003e\n\u003cli\u003eAnalog output: Eight 4-20 mA channels\u003c\/li\u003e\n\u003cli\u003eVisual indication: Red LED for breaker closed status\u003c\/li\u003e\n\u003cli\u003eFully isolated outputs for enhanced noise immunity\u003c\/li\u003e\n\u003cli\u003eHigh-speed response: 100% indication in less than 3 power system cycles\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e750-P5-G5-HI-A1-R-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e25 VA nominal, 35 VA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMake and Carry\u003c\/td\u003e\n\u003ctd\u003e15 A @ 250 VDC for 500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Loss Hold-up Time\u003c\/td\u003e\n\u003ctd\u003e30 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eUp to 95% (non-condensing) @ 55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the relay is installed in a clean, dry environment protected from excessive dust and moisture.\u003c\/li\u003e\n\u003cli\u003eVerify that the control power supply matches the specified voltage range (80-300 V DC or 70-265 V AC) before applying power.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for analog inputs and outputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the relay chassis to the panel ground bus to maintain signal integrity and safety.\u003c\/li\u003e\n\u003cli\u003ePerform all wiring connections while the system is de-energized to prevent accidental short circuits or damage to the internal electronics.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the unit to allow for proper heat dissipation and airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 750-P5-G5-HI-A1-R-E relay?\u003c\/h3\u003e\u003cp\u003eThis unit is a feeder management relay designed to provide protection, control, and monitoring for electrical distribution systems, specifically handling phase, ground, and sensitive current inputs.\u003c\/p\u003e\u003ch3\u003eDoes this relay require a specific power supply?\u003c\/h3\u003e\u003cp\u003eYes, this model supports a wide range of input power, specifically 80-300 V DC or 70-265 V AC at 48\/62 Hz.\u003c\/p\u003e\u003ch3\u003eWhat is the ambient operating temperature range?\u003c\/h3\u003e\u003cp\u003eThe device is rated for operation in temperatures ranging from -40 degC to +60 degC.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50980411441404,"sku":"750-P5-G5-HI-A1-R-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_011237a4-5e09-4961-8e60-df19fc2869d6.jpg?v=1786724266"},{"product_id":"general-electric-multilin-ur-8ah-ct-vt-module","title":"General Electric Multilin UR 8AH CT\/VT Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric Multilin UR 8AH is a specialized CT\/VT (Current Transformer\/Voltage Transformer) input module designed for use within the Universal Relay (UR) platform. This horizontal unit is engineered to provide precise analog signal acquisition for protection and monitoring applications, featuring sensitive ground fault detection capabilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eConfigured for sensitive ground sensing applications.\u003c\/li\u003e\n\u003cli\u003eEquipped with 4 CT inputs and 4 VT inputs.\u003c\/li\u003e\n\u003cli\u003eSupports standard 1 A or 5 A current transformer inputs.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy signal processing for reliable relay performance.\u003c\/li\u003e\n\u003cli\u003eDesigned for integration into the standard UR chassis environment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eUR 8AH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Inputs\u003c\/td\u003e\n\u003ctd\u003e3 x 1 A or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround CT Input\u003c\/td\u003e\n\u003ctd\u003e1 x 1 A or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT Inputs\u003c\/td\u003e\n\u003ctd\u003e4 x 50 – 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurden\u003c\/td\u003e\n\u003ctd\u003eCT ≤ 0.12 VA @ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2 % of reading ± 0.02 % of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45 – 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2 kV AC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (inside UR chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +95 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 – 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the relay chassis is powered down before inserting or removing the UR 8AH module.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated horizontal slot of the UR chassis, ensuring proper alignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the integrated front-panel fasteners to ensure a solid electrical ground connection to the chassis.\u003c\/li\u003e\n\u003cli\u003eVerify that all CT and VT wiring is correctly terminated according to the specific relay wiring diagram to prevent measurement errors or hazardous open-CT conditions.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the control cabinet to ensure the module operates within its specified temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the UR 8AH module?\u003c\/h3\u003e\u003cp\u003eThe UR 8AH is an analog input module for the GE Multilin Universal Relay series, specifically designed to process current and voltage signals, including sensitive ground current measurement.\u003c\/p\u003e\u003ch3\u003eCan this module be used in any UR chassis?\u003c\/h3\u003e\u003cp\u003eThis is a horizontal unit designed for standard UR chassis configurations. Please verify your specific relay model's hardware compatibility before installation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50986074013948,"sku":"UR 8AH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_0f94173e-f229-4b26-bd0c-4cd8cb80d7f9.jpg?v=1786814913"},{"product_id":"general-electric-mark-vie-is200vturh2bac-vibration-transducer-interface-module","title":"General Electric IS200VTURH2BAC Mark VIe Vibration Transducer Interface Module","description":"\u003cp\u003eThe General Electric IS200VTURH2BAC is a Vibration Transducer Interface Module designed for the Mark VIe control system. This module facilitates the acquisition and processing of vibration data from sensors, providing critical monitoring capabilities for rotating machinery in industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for high-precision vibration monitoring within the Mark VIe platform.\u003c\/li\u003e\n\u003cli\u003eSupports multiple analog voltage input channels for versatile sensor connectivity.\u003c\/li\u003e\n\u003cli\u003eIntegrated proximity probe power supply with stable voltage output.\u003c\/li\u003e\n\u003cli\u003eRobust channel-to-channel isolation to prevent signal interference and ensure measurement integrity.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range suitable for demanding industrial cabinet environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily utilized in power generation and heavy industrial applications, including the monitoring of turbines, compressors, and large motors. It serves as a critical interface between field-mounted vibration transducers and the main control system, ensuring accurate data acquisition for predictive maintenance and operational safety.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIS200VTURH2BAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpare Model\u003c\/td\u003e\n\u003ctd\u003eIS200VTURH2B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 to 8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProximity Probe Input\u003c\/td\u003e\n\u003ctd\u003e-18 V DC +\/- 5% (250 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/- 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before inserting or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eUse appropriate ESD protection when handling the module to prevent damage to sensitive electronic components.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the module chassis to the system common to minimize noise and EMI.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage power lines to maintain signal fidelity.\u003c\/li\u003e\n\u003cli\u003eVerify that the rack slot is clean and free of debris before installation to ensure reliable backplane connection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IS200VTURH2BAC?\u003c\/h3\u003e\u003cp\u003eThis module acts as an interface for vibration transducers, converting field signals into a format compatible with the GE Mark VIe control system for monitoring and analysis.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with the IS200VTURH2B?\u003c\/h3\u003e\u003cp\u003eYes, the IS200VTURH2BAC is often considered a functional replacement or revision for the IS200VTURH2B model; however, always verify system revision requirements before installation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50986082566396,"sku":"IS200VTURH2BAC","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_1527e16f-953b-4927-b748-329b77df7649.jpg?v=1786816325"},{"product_id":"general-electric-multilin-ur-5eh-transducer-i-o-module","title":"General Electric Multilin UR 5EH Transducer I\/O Module","description":"\u003cp\u003eThe General Electric Multilin UR 5EH is a high-performance Transducer I\/O Module designed for use within the Universal Relay (UR) protection system. This horizontal unit is specifically engineered to provide reliable data acquisition for industrial monitoring applications, featuring 8 RTD inputs for precise temperature sensing.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 RTD input channels for comprehensive temperature monitoring.\u003c\/li\u003e\n\u003cli\u003eRobust industrial design suitable for harsh environments.\u003c\/li\u003e\n\u003cli\u003eHigh input impedance in voltage mode (\u0026gt; 1 MΩ).\u003c\/li\u003e\n\u003cli\u003eStandardized current mode input impedance (250 Ω).\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation rated at 2.5 kV RMS for signal integrity and protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eUR 5EH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eTransducer I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Mode Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Mode Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input\u003c\/td\u003e\n\u003ctd\u003e±15 V DC or ±30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2.5 kV RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is powered down before installing or removing the module from the UR chassis to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is securely seated in the designated horizontal slot and that all locking mechanisms are engaged.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for RTD inputs to minimize electromagnetic interference (EMI) in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the cabinet to ensure the module operates within its specified temperature range of -40 degC to +70 degC.\u003c\/li\u003e\n\u003cli\u003eAdhere to standard ESD (Electrostatic Discharge) handling procedures when touching internal circuitry or connectors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat type of inputs does the UR 5EH support?\u003c\/h3\u003e\u003cp\u003eThe UR 5EH is a Transducer I\/O module specifically configured with 8 RTD (Resistance Temperature Detector) inputs for temperature measurement.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other Universal Relay series components?\u003c\/h3\u003e\u003cp\u003eYes, the UR 5EH is designed as a component of the General Electric Multilin UR platform. Ensure your specific relay chassis supports the horizontal I\/O configuration.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50988608618748,"sku":"UR 5EH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_7d2ef70d-a266-41da-b473-6381fc399873.jpg?v=1786907855"},{"product_id":"general-electric-multilin-ur-9ev-cpu-processor-module","title":"General Electric Multilin UR 9EV CPU Processor Module","description":"\u003cp\u003eThe General Electric Multilin UR 9EV is a high-performance CPU processor module designed for the Universal Relay (UR) platform. This module serves as the central processing unit for protection and control relays, providing advanced computational capabilities for demanding industrial power system applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-speed processing architecture for real-time protection and control.\u003c\/li\u003e\n\u003cli\u003e16-bit A\/D conversion resolution for precise signal measurement.\u003c\/li\u003e\n\u003cli\u003eSampling rate of 64 samples per cycle to ensure accurate waveform analysis.\u003c\/li\u003e\n\u003cli\u003eDesigned for integration within the Multilin UR series relay chassis.\u003c\/li\u003e\n\u003cli\u003eRobust thermal design suitable for harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eUR 9EV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCPU Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e220 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd\u003e50 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Conversion\u003c\/td\u003e\n\u003ctd\u003e16-bit resolution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e64 samples\/cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the relay chassis is powered down before attempting to install or remove the UR 9EV module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the designated CPU slot and that the locking mechanisms are engaged.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the relay housing to maintain operating temperatures within the specified -40 degC to +70 degC range.\u003c\/li\u003e\n\u003cli\u003eConfirm that the input voltage matches the 220 V rating before energizing the system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the UR 9EV?\u003c\/h3\u003e\u003cp\u003eThe UR 9EV is a CPU processor module used in General Electric Multilin Universal Relays to handle logic, protection algorithms, and system communication.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with all UR series relays?\u003c\/h3\u003e\u003cp\u003eThe UR 9EV is specific to the Multilin UR platform. Please verify your relay's specific hardware revision and compatibility requirements before installation.\u003c\/p\u003e\u003ch3\u003eWhat are the environmental requirements for this module?\u003c\/h3\u003e\u003cp\u003eThe module is designed for industrial use with an operating temperature range of -40 degC to +70 degC and should be kept in a non-condensing environment with humidity between 5% and 95%.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50995066077436,"sku":"UR 9EV","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_549106df-78bc-47f7-9846-941121cc39e7.jpg?v=1787074327"},{"product_id":"general-electric-multilin-ur-4dh-digital-i-o-module","title":"General Electric Multilin UR 4DH Digital I\/O Module","description":"\u003cp\u003eThe General Electric Multilin UR 4DH is a high-performance digital input\/output module designed for the Universal Relay (UR) platform. This module significantly expands the relay's capability to interface with field devices, providing essential monitoring, control, and protection functions for complex power system architectures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned specifically for the GE Multilin UR Series relay platform.\u003c\/li\u003e\n\u003cli\u003eSupports high-density digital I\/O configurations for comprehensive substation automation.\u003c\/li\u003e\n\u003cli\u003eFlexible output options including Form-A, Form-C, fast-operating contacts, and solid-state relay (SSR) variants.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostic capabilities for circuit continuity monitoring and current detection.\u003c\/li\u003e\n\u003cli\u003eRobust design suitable for demanding utility and industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProtection and control for large generators, including steam, gas, and hydro turbines.\u003c\/li\u003e\n\u003cli\u003eMonitoring and protection for high-horsepower industrial motors and pumps.\u003c\/li\u003e\n\u003cli\u003ePrimary and backup protection for power transformers and distribution systems.\u003c\/li\u003e\n\u003cli\u003eComplex busbar protection for low-voltage to extra-high-voltage switchgear.\u003c\/li\u003e\n\u003cli\u003eControl and stability management for capacitor banks.\u003c\/li\u003e\n\u003cli\u003eElectrical protection for oil and gas infrastructure and mining operations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR 4DH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e16 (expandable per relay configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e24V DC to 250V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Rating\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms (state changes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the main UR relay is powered down before attempting to insert or remove modules.\u003c\/li\u003e\n\u003cli\u003eAccess the internal module slots by loosening the screw on the hinged faceplate of the relay.\u003c\/li\u003e\n\u003cli\u003eApply steady pressure to the push pins to slide the module into the designated slot; ensure it is fully seated.\u003c\/li\u003e\n\u003cli\u003eWire digital inputs and outputs according to the specific wiring diagram provided in your relay's technical manual.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices and ensure shielded cabling is used for signal integrity in high-EMI environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the UR 4DH?\u003c\/h3\u003e\u003cp\u003eThe UR 4DH serves as a digital I\/O expansion module for the GE Multilin UR series, allowing the relay to interface with up to 96 inputs and 64 outputs for protection, interlocking, and control tasks.\u003c\/p\u003e\u003ch3\u003eAre the outputs configurable?\u003c\/h3\u003e\u003cp\u003eYes, the module supports various output types, including Form-A, Form-C, fast-operating contacts, and solid-state relays (SSR) to accommodate specific application requirements.\u003c\/p\u003e\u003ch3\u003eWhat is the response time for the outputs?\u003c\/h3\u003e\u003cp\u003eForm-A outputs feature activation speeds of less than 4 milliseconds, providing high-speed tripping capabilities.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51008852361468,"sku":"UR 4DH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_d05c8df8-d5e5-454d-aac9-909848fd41df.jpg?v=1787590003"},{"product_id":"general-electric-multilin-ur-8fv-relay-module","title":"General Electric Multilin UR 8FV Relay Module","description":"\u003cp\u003eThe General Electric Multilin UR 8FV is a high-performance relay module designed for the Universal Relay (UR) series, providing robust protection and control capabilities for industrial power systems. This module is engineered to support wide-range power supply inputs and precise measurement accuracy, ensuring reliable operation in demanding electrical environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWide-range power supply compatibility: 85-265 VAC \/ 100-300 VDC.\u003c\/li\u003e\n\u003cli\u003eHigh-precision measurement: ±0.5% accuracy for voltage and ±1% accuracy for current inputs.\u003c\/li\u003e\n\u003cli\u003eIntegrated communication: Supports 10\/100 Mbps Ethernet connectivity for seamless system integration.\u003c\/li\u003e\n\u003cli\u003eIndustrial-grade durability: Rated for reliable operation in temperatures ranging from -40 degC to +70 degC.\u003c\/li\u003e\n\u003cli\u003eFlexible input configurations: Supports 1A or 5A current inputs and 100V or 120V voltage inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis relay module is primarily utilized within the GE Multilin UR protection platform. It is suitable for utility and industrial power distribution systems, including transformer protection, generator management, and feeder protection schemes where high-speed relaying and network communication are required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eUR 8FV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e85-265 VAC \/ 100-300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Ratings\u003c\/td\u003e\n\u003ctd\u003e10A at 250VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is fully de-energized before installing or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is securely seated in the designated UR chassis slot to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for Ethernet connections to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the chassis to prevent heat buildup, adhering to the specified operating temperature range.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the chassis to a common station ground to protect against surge transients.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eQ: Is the UR 8FV compatible with all UR series chassis?\u003c\/strong\u003e\u003cbr\u003eA: The UR 8FV is designed for the GE Multilin UR platform. Please verify your specific chassis revision and firmware compatibility before installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of this module?\u003c\/strong\u003e\u003cbr\u003eA: This is a relay output module used for control and protection switching within the UR relay system.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51008855703804,"sku":"UR 8FV","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8adc294c-b286-4b6b-8143-69aac9f5b017.jpg?v=1787590232"},{"product_id":"general-electric-multilin-ur-8gh-ct-vt-module","title":"General Electric Multilin UR 8GH CT\/VT Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric Multilin UR 8GH is a specialized CT\/VT (Current Transformer\/Voltage Transformer) input module designed for the Universal Relay (UR) platform. This horizontal-mount module provides high-precision signal acquisition for protective relaying applications, featuring a configuration of 4 CT and 4 VT inputs to support complex monitoring and protection schemes within the UR chassis.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for integration with the GE Multilin Universal Relay (UR) series.\u003c\/li\u003e\n\u003cli\u003eHorizontal chassis mounting configuration.\u003c\/li\u003e\n\u003cli\u003eSupports 8 total inputs (4 CT and 4 VT channels).\u003c\/li\u003e\n\u003cli\u003eHigh accuracy measurement suitable for critical power system protection.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range for demanding industrial environments.\u003c\/li\u003e\n\u003cli\u003eRobust isolation to protect internal relay circuitry from transient surges.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eUR 8GH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Inputs\u003c\/td\u003e\n\u003ctd\u003e8 x 1 A or 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVT Inputs\u003c\/td\u003e\n\u003ctd\u003e4 x 50 – 240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCT Burden\u003c\/td\u003e\n\u003ctd\u003e≤ 0.12 VA @ 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.2 % of reading ± 0.02 % of range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e45 – 65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2 kV AC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC (chassis internal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 degC to +95 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 – 95 % RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the UR chassis is fully de-energized before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using standard ESD (Electrostatic Discharge) precautions to prevent damage to sensitive internal components.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated horizontal slot of the UR chassis, ensuring the backplane connectors are properly aligned.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the integrated locking mechanisms or mounting screws to ensure proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003eVerify that all CT and VT wiring is correctly terminated according to the specific relay wiring diagram to avoid measurement errors or secondary circuit hazards.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with all GE Multilin UR series relays?\u003c\/strong\u003e\u003cbr\u003eA: The UR 8GH is designed for specific UR chassis configurations. Please verify your relay's ordering code and hardware compatibility before installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: What is the primary function of the UR 8GH?\u003c\/strong\u003e\u003cbr\u003eA: This module serves as the analog interface for the relay, converting high-voltage and high-current inputs from the power system into low-level signals that the processor can analyze for protection and metering.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51015646511356,"sku":"UR 8GH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_118234b3-820a-493e-924c-7ef42abfcc96.jpg?v=1787770364"},{"product_id":"general-electric-mark-vie-is220pturh1b-i-o-pack","title":"General Electric IS220PTURH1B Mark VIe Turbine I\/O Pack","description":"\u003cp\u003eThe General Electric IS220PTURH1B is a specialized I\/O pack designed for the Mark VIe Speedtronic control system. This module is engineered for critical turbine protection and control applications, including the regulation of Heat Recovery Steam Generator (HRSG) systems. It serves as a primary interface for turbine input and output signals, ensuring high-reliability performance in demanding power generation environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned specifically for Mark VIe Speedtronic gas turbine control architectures.\u003c\/li\u003e\n\u003cli\u003eSupports primary turbine protection functions.\u003c\/li\u003e\n\u003cli\u003eIntegrated I\/O processing for HRSG and boiler regulation.\u003c\/li\u003e\n\u003cli\u003eRobust construction suitable for extreme industrial temperature ranges.\u003c\/li\u003e\n\u003cli\u003eHigh-isolation voltage rating to protect sensitive control circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis I\/O pack is primarily utilized in power generation facilities, specifically within gas turbine control systems. It is essential for monitoring and managing turbine inputs and outputs, as well as coordinating the operational parameters of HRSG systems to maintain safe and efficient plant performance.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIS220PTURH1B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e8 x 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e28 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e27 VA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC (-40 to +158 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-55 to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before attempting to install or remove the I\/O pack to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is properly seated in the designated Mark VIe rack slot to ensure reliable backplane communication.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to minimize electromagnetic interference (EMI) and protect against surge events.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation within the control cabinet to maintain operating temperatures within the specified -40 to +70 degC range.\u003c\/li\u003e\n\u003cli\u003eHandle with care using ESD-safe procedures to prevent damage to internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IS220PTURH1B?\u003c\/strong\u003e\u003cbr\u003eThe IS220PTURH1B is an I\/O pack used in GE Mark VIe systems for turbine control, specifically handling turbine I\/O and primary protection tasks, including HRSG regulation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module operate in freezing conditions?\u003c\/strong\u003e\u003cbr\u003eYes, the module is rated for an operating temperature range of -40 to +70 degC, making it suitable for harsh, unconditioned industrial environments.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51020508954876,"sku":"IS220PTURH1B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_5ac11bba-cd3a-4a87-97b4-9cb6b5b2210c.jpg?v=1787861114"},{"product_id":"general-electric-multilin-469-p5-hi-a1-e-h-motor-management-relay","title":"General Electric Multilin 469-P5-HI-A1-E-H Motor Management Relay","description":"\u003cp\u003eThe General Electric Multilin 469-P5-HI-A1-E-H is a comprehensive motor management relay designed to provide protection, control, and monitoring for medium and large AC motors. This unit is engineered to support industrial motor applications by integrating advanced protection algorithms with versatile communication and I\/O capabilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAdvanced motor protection including thermal modeling, stall, jam, and phase reversal detection.\u003c\/li\u003e\n\u003cli\u003eEquipped with 5 Amp phase CT secondaries for precise current sensing.\u003c\/li\u003e\n\u003cli\u003eWide-range auxiliary power supply supporting 90-300 VDC or 70-265 VAC (48-62 Hz).\u003c\/li\u003e\n\u003cli\u003eIntegrated 4-20 mA analog output for process control and monitoring.\u003c\/li\u003e\n\u003cli\u003eNine opto-isolated digital inputs for flexible system integration.\u003c\/li\u003e\n\u003cli\u003eSupport for multiple RTD types including 100 Ohm Platinum, 100\/120 Ohm Nickel, and 10 Ohm Copper sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e469-P5-HI-A1-E-H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eMotor Management Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase CT Secondaries\u003c\/td\u003e\n\u003ctd\u003e5 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Range\u003c\/td\u003e\n\u003ctd\u003e90-300 VDC \/ 70-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e48-62 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0-1 mA, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e9 Opto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Sensing Current\u003c\/td\u003e\n\u003ctd\u003e5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the relay is mounted in a clean, dry, and vibration-free environment, typically within a control cabinet or panel.\u003c\/li\u003e\n\u003cli\u003eVerify that all CT connections are secure and properly grounded to prevent high-voltage buildup.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog and communication signals to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eAlways disconnect power before inserting or removing the module from the rack or panel.\u003c\/li\u003e\n\u003cli\u003eEnsure the auxiliary power supply voltage matches the specified range (90-300 VDC or 70-265 VAC) to avoid internal component damage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the 469-P5-HI-A1-E-H relay?\u003c\/strong\u003e This device is a digital motor management relay used to protect medium and large AC motors from electrical faults, thermal overload, and mechanical stress.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this relay handle different types of RTD sensors?\u003c\/strong\u003e Yes, the unit supports 100 Ohm Platinum (DIN 43760), 100 Ohm Nickel, 120 Ohm Nickel, and 10 Ohm Copper 3-wire RTD sensors.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51020549685500,"sku":"469-P5-HI-A1-E-H","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_2f0eaf26-c74d-45bb-975c-77ee3b382728.jpg?v=1787861491"},{"product_id":"general-electric-multilin-ur-9uh-cpu-module","title":"General Electric Multilin UR 9UH CPU Module","description":"\u003cp\u003eThe General Electric Multilin UR 9UH is a high-performance CPU module designed for the Universal Relay (UR) platform. It functions as the central processing engine for the relay, executing critical protection logic, control functions, and monitoring routines essential for power system automation and protection.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCore processing engine for UR Series relays, supporting complex protection algorithms for generators, transformers, motors, and transmission lines.\u003c\/li\u003e\n\u003cli\u003eIntegrated communication suite including one 10\/100 Base-T Ethernet port (RJ45), two 100 Base-FX fiber optic ports (LC connector, multimode 1310 nm), and one RS485 serial port.\u003c\/li\u003e\n\u003cli\u003eSupports advanced industry protocols: IEC 61850, DNP3, Modbus RTU\/TCP, and IEEE C37.118 synchrophasors.\u003c\/li\u003e\n\u003cli\u003eEnables high-speed network redundancy via Parallel Redundancy Protocol (PRP) and precise time synchronization using IEEE 1588 PTP (accuracy up to 1 microsecond).\u003c\/li\u003e\n\u003cli\u003eEquipped with a 1 GHz embedded processor, 512 MB RAM, and 1 GB flash storage for deterministic real-time data processing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGenerator Protection: Monitoring voltage, frequency, and current for medium to large-scale generators.\u003c\/li\u003e\n\u003cli\u003eTransmission Line Management: Providing distance and differential protection for grid stability.\u003c\/li\u003e\n\u003cli\u003eTransformer and Motor Protection: Implementing thermal modeling and fault detection.\u003c\/li\u003e\n\u003cli\u003eSubstation Automation: Facilitating high-speed SCADA\/DCS integration and centralized breaker control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eUR 9UH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e1 GHz Embedded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e512 MB RAM \/ 1 GB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Port\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Base-T (RJ45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Optic Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 100 Base-FX (LC, Multimode 1310nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Port\u003c\/td\u003e\n\u003ctd\u003e1 x RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe UR 9UH is a modular component intended for rack mounting within the standard UR relay chassis.\u003c\/li\u003e\n\u003cli\u003eEnsure the relay is fully powered down before inserting or removing the CPU module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the input voltage matches the specific relay configuration requirements.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding of the chassis to ensure electromagnetic compatibility and operator safety.\u003c\/li\u003e\n\u003cli\u003eConfiguration and setpoint management are conducted via the EnerVista Launchpad software suite.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the UR9UH module?\u003c\/h3\u003e\u003cp\u003eThe UR9UH acts as the central processing unit (CPU) for the Universal Relay platform. It manages the relay's internal logic, executes protection algorithms, and handles multi-protocol communication for substation automation.\u003c\/p\u003e\u003ch3\u003eDoes this module support IEC 61850?\u003c\/h3\u003e\u003cp\u003eYes, the UR9UH supports advanced communication protocols including IEC 61850, DNP3, and Modbus TCP\/RTU.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with older UR relay hardware?\u003c\/h3\u003e\u003cp\u003eThe UR9UH is designed to maintain compatibility within the Universal Relay (UR) family, supporting various models such as the D60, F60, G60, and L90.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51183330722044,"sku":"UR 9UH","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_17e875e7-eb06-477e-8c74-2b2a4795424e.jpg?v=1788112764"},{"product_id":"269plus-100p-120-ge-multilin-269-plus-motor-management-relay","title":"General Electric Multilin 269PLUS-100P-120 Motor Management Relay","description":"\u003cp\u003eThe General Electric Multilin 269PLUS-100P-120 is a specialized motor management relay designed for the protection, control, and monitoring of AC motors. This unit provides comprehensive protection features to ensure motor longevity and operational safety in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for 100 Ohm Platinum RTD input sensors.\u003c\/li\u003e\n\u003cli\u003eSupports 120 V AC \/ 125 V DC control voltage configurations.\u003c\/li\u003e\n\u003cli\u003eEquipped with 4 relay connections for flexible output control.\u003c\/li\u003e\n\u003cli\u003eIntegrated protection logic with a maximum current rating of 2 Amps.\u003c\/li\u003e\n\u003cli\u003eRobust construction with an operating temperature range of -25 degC to +60 degC.\u003c\/li\u003e\n\u003cli\u003eReliable operation in high-humidity environments up to 95% non-condensing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e269PLUS-100P-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMultilin 269 Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC \/ 125 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Type\u003c\/td\u003e\n\u003ctd\u003e100 Ohm Platinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the device is powered down before performing any wiring or installation.\u003c\/li\u003e\n\u003cli\u003eMount the relay in a clean, dry, and vibration-free environment to prevent premature component failure.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded cabling for RTD inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eVerify that the control voltage matches the specifications on the device label before energizing.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the unit to ensure proper ventilation and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eFollow standard industrial grounding practices to protect the relay from transient surges.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the 269PLUS-100P-120?\u003c\/strong\u003e This relay is engineered to provide motor management, including thermal protection and monitoring using RTD inputs for critical industrial motor applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this unit support DC control voltage?\u003c\/strong\u003e Yes, this specific model is rated for 120 V AC or 125 V DC control voltage.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51213332087036,"sku":"269PLUS-100P-120","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_20551a8c-e480-4905-8dfb-700fb72d3bb6.jpg?v=1788234749"}],"url":"https:\/\/www.electronicplc.com\/collections\/ge-multilin.oembed?page=3","provider":"Electronic PLC","version":"1.0","type":"link"}