{"title":"GE VersaMax","description":"\u003cp\u003eThe GE VersaMax platform is defined by its modularity and space-saving design, functioning as both a standalone PLC and a distributed I\/O station. This collection includes CPUs, I\/O modules, and power supplies that can be mixed and matched to fit specific application footprints. Ideal for machine-level control or as remote I\/O for RX3i systems, VersaMax hardware is valued for its versatility and ease of installation. We provide the technical spares needed to maintain these flexible systems, ensuring that your modular control architectures remain responsive and reliable across a variety of industrial settings.\u003c\/p\u003e","products":[{"product_id":"expansion-terminator-module-ge-fanuc-versamax-series-ic200acc201","title":"Expansion Terminator Module GE Fanuc VersaMax Series IC200ACC201","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical component within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc VersaMax PLC architecture\u003c\/strong\u003e. As an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexpansion terminator\u003c\/strong\u003e, it is specifically designed to terminate the final expansion receiver in a communication chain. By providing essential signal termination, this module prevents\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal reflection\u003c\/strong\u003e, ensuring the long-term integrity and reliability of the data bus. It is a vital spare part for maintaining uptime in complex industrial control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC200ACC201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminates the last expansion receiver in a chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExclusively for VersaMax PLC systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ACC201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-tier industrial control networks\u003c\/strong\u003e, where multiple I\/O racks are daisy-chained. Proper termination at the final node is crucial to eliminate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal bouncing\u003c\/strong\u003e, which can cause intermittent communication errors or total system failures. Its robust environmental ratings make it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efactory floor conditions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas well as more\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edemanding industrial environments\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is the IC200ACC201 necessary?\u003c\/strong\u003e\u003cbr\u003eWithout proper termination at the end of an expansion cable, signal reflections can cause interference, leading to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata corruption\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommunication timeouts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween the CPU and remote I\/O.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this terminator be used with other PLC series?\u003c\/strong\u003e\u003cbr\u003eNo, the IC200ACC201 is specifically designed for the communication protocols used within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax PLC system\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if this module fails?\u003c\/strong\u003e\u003cbr\u003eA faulty or missing terminator often results in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"bus error\" diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the PLC, which can cause the system to stop communicating with remote expansion modules. It is recommended to keep this spare on hand for rapid maintenance.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730062076,"sku":"IC200ACC201","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG230.jpg?v=1773299425"},{"product_id":"ic200alg230-ge-fanuc-versamax-analog-input-module","title":"IC200ALG230 GE Fanuc VersaMax Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG230\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-channel analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc VersaMax programmable logic controller (PLC)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. This module offers high-precision signal processing for industrial instrumentation, with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-bit resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor both voltage and current loop inputs. Its small footprint and integrated design make it ideal for space-constrained control panels, ensuring reliable analog data acquisition in various industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC200ALG230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Input Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVoltage and Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersaMax PLC System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDesign\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompact modular architecture for easy DIN-rail mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard opto-isolation for logic-to-field signal protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed scanning suitable for standard process loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG230 is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esmall-scale automation projects\u003c\/strong\u003e, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emachine monitoring\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esecondary process controls\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especialized laboratory automation\u003c\/strong\u003e. It is most suitable for applications that require standard resolution for sensors such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure gauges\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflow meters\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epotentiometric sensors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between this model and the high-density versions?\u003c\/strong\u003e\u003cbr\u003eThe IC200ALG230 is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-channel module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-bit resolution\u003c\/strong\u003e, making it a more economical option for applications that do not require the higher channel counts or the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-bit precision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efound in advanced models.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes, the IC200ALG230 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping\u003c\/strong\u003e, similar to other components in the VersaMax I\/O family. This feature allows for maintenance without interrupting backplane communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support universal inputs?\u003c\/strong\u003e\u003cbr\u003eThe module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent input ranges\u003c\/strong\u003e, and these are configurable to meet the specific needs of connected field sensors.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730094844,"sku":"IC200ALG230","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG230.jpg?v=1773299425"},{"product_id":"ge-fanuc-ic200alg240-versamax-analog-input-module","title":"GE Fanuc IC200ALG240 VersaMax Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG240\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog input module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE Fanuc VersaMax PLC system\u003c\/strong\u003e. This module features eight channels, each fully isolated to protect signal integrity and prevent ground loops in complex industrial environments. It supports both voltage and current loop inputs, making it ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einstrumentation applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat demand high precision.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC200ALG240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Independent Channels, Channel-to-Channel Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10 VDC or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e381 nA (Current mode), 381 µV (Voltage mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 mA max at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Power Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.5-30 VDC (includes ripple)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eField Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA max plus connected load current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 ms (50 Hz filter), 16.7 ms (60 Hz filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 cm x 11 cm x 6.68 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG240 is specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata acquisition systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere signal noise immunity is critical. It is ideal for use cases involving pressure, flow, and temperature transmitters in industries such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewater management\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediscrete manufacturing\u003c\/strong\u003e. Its isolated design ensures accurate signal conversion even when sensors are at different potential levels or located at varying distances.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of the channel-to-channel isolation?\u003c\/strong\u003e\u003cbr\u003eThe isolation ensures that electrical noise or ground potential differences from one sensor circuit do not affect the readings of other channels, providing high signal fidelity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require external power to function?\u003c\/strong\u003e\u003cbr\u003eYes, external field power of 19.5-30 VDC is required to power the input circuitry and the connected sensors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module measure both current and voltage on the same module?\u003c\/strong\u003e\u003cbr\u003eYes, the input type is selectable on a per-channel basis, allowing you to mix current and voltage inputs within the same IC200ALG240 module.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730127612,"sku":"IC200ALG240","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG240.jpg?v=1773299425"},{"product_id":"ic200alg321-analog-voltage-output-module-ge-fanuc","title":"IC200ALG321 Analog Voltage Output Module GE Fanuc","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IC200ALG321\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a 4-channel analog voltage output module from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE VersaMax I\/O\u003c\/strong\u003e. It delivers precise 0–10 VDC signals for industrial control applications, interfacing with devices like proportional valves, VFDs, and data loggers. With 12-bit resolution and built-in diagnostics, it ensures high-fidelity control in automated systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identifier\u003c\/td\u003e\n\u003ctd\u003eIC200ALG321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e4 analog voltage outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC (nominal), up to 10.24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (2.5 mV per bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.3% typical, 1% max full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e0.3 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18–30 VDC or 9.6–15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous \/ 1500 VAC (1 min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFast 0.3 ms update rate for dynamic control loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGalvanic isolation protects both field devices and logic circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED indicators provide instant feedback on backplane and field power\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSingle-ended wiring simplifies installation in industrial panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for precision analog control in automated manufacturing and process systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaintenance and Diagnostics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOn-board LEDs indicate module health and help isolate field or communication issues\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports flexible DC input voltages for varied industrial power setups\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-resolution output ensures precise linearity and repeatability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200ALG321 be used for current outputs?\u003c\/strong\u003e\u003cbr\u003eNo. This module is strictly for 0–10 VDC voltage outputs. Use VersaMax current output modules for mA loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module configured within VersaMax systems?\u003c\/strong\u003e\u003cbr\u003eOutput scaling and default states are set through the PLC software during hardware setup.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746730160380,"sku":"IC200ALG321","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG321.jpg?v=1773212383"},{"product_id":"ic200alg322d-ge-fanuc-plc-analog-output-module","title":"IC200ALG322D GE Fanuc PLC Analog Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200ALG322D (IC200ALG322)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision 4-channel analog output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eGE Fanuc\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. Designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial process control\u003c\/strong\u003e, it provides 4 to 20 mA current loop outputs to drive actuators, valves, and VFDs. The \"D\" revision enhances thermal performance and component longevity while remaining fully compatible with previous IC200ALG322 modules.\u003c\/p\u003e\n\u003cp\u003eWith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-bit resolution\u003c\/strong\u003e, the IC200ALG322D ensures smooth and granular control over process variables. Each channel includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen-wire detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand loop power monitoring for proactive fault diagnostics. Its compact footprint allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density installation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon standard VersaMax carriers, while the module draws internal logic power from the backplane and requires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexternal 24V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor output loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200ALG322D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eCurrent Loop (4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit (1 part in 4000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Load\u003c\/td\u003e\n\u003ctd\u003e0–850 Ω (at 24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e24V DC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Draw\u003c\/td\u003e\n\u003ctd\u003e50 mA (from 5V backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e4 ms (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLoop power and open-wire detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC (field vs logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F – 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Weight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Loop Management\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount on an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS series carrier\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshielded twisted-pair cabling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain 12-bit precision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLED indicator signals normal operation (green) or alerts (amber\/off) for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eloss of 24V field power or hardware faults\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IC200ALG322D support voltage outputs (0–10V)?\u003c\/strong\u003e\u003cbr\u003eNo. This module is strictly a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA current output\u003c\/strong\u003e. Voltage output requires a different module (e.g., IC200ALG321) or an external 500 Ω resistor for current-to-voltage conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if a field wire is broken?\u003c\/strong\u003e\u003cbr\u003eThe module detects\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen-wire conditions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand reports a \"Low Scale\" or \"Open Wire\" fault to the CPU, enabling immediate maintenance intervention.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746790289660,"sku":"IC200ALG322D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200ALG322D1.jpg?v=1771055433"},{"product_id":"ic200chs001-ge-fanuc-versamax-barrier-style-i-o-carrier","title":"IC200CHS001 GE Fanuc VersaMax Barrier-Style I\/O Carrier","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS001 (IC200-CHS-001)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebarrier-style wiring base\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the GE Fanuc\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax I\/O platform\u003c\/strong\u003e. It provides a rugged mechanical and electrical interface between field devices and I\/O modules, featuring an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen barrier-strip design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor easy access to termination points. The carrier supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swapping of modules\u003c\/strong\u003e, integrated mechanical keying to prevent incorrect installation, and accommodates both AC and DC signals, making it suitable for demanding industrial environments with high vibration or heavy-duty wiring requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200CHS001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBarrier-Style Screw Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e0–264 VAC (Operational)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Protection\u003c\/td\u003e\n\u003ctd\u003eUp to 300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per signal point \/ 8 A per power\/ground terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Capacity\u003c\/td\u003e\n\u003ctd\u003e1–2 wires per terminal (must be same type\/size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Requirement\u003c\/td\u003e\n\u003ctd\u003eCopper, rated ≥ 90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Torque\u003c\/td\u003e\n\u003ctd\u003e0.37–0.50 ft-lbs (0.5–0.68 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Mechanism\u003c\/td\u003e\n\u003ctd\u003eAdjustable rotary dials for module-to-carrier matching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail or panel-mounted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eWiring and Installation Notes\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUse high-quality copper conductors; two wires in a terminal must be identical in type and size.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBarrier strips provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephysical separation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween terminals, reducing risk of shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor panel mounting, ensure a proper ground path through the backplane and carrier frame for EMI and transient protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between IC200CHS001 and IC200CHS002?\u003c\/strong\u003e\u003cbr\u003eThe IC200CHS001 uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebarrier-style exposed screw terminal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuitable for ring or spade lugs and high-vibration environments. The IC200CHS002 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebox-style\u003c\/strong\u003e, using cage terminals for wire insertion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this carrier be mounted on a non-conductive surface?\u003c\/strong\u003e\u003cbr\u003eYes, it can be panel-mounted, but ensure proper grounding through the backplane and carrier frame to maintain EMI shielding and transient protection.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746790715644,"sku":"IC200CHS001","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200CHS0011.jpg?v=1771055433"},{"product_id":"ic200chs002-ge-fanuc-plc-i-o-carrier-module","title":"IC200CHS002 GE Fanuc PLC I\/O Carrier Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS002 (IC200-CHS-002)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emounting and wiring carrier\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the Emerson\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVersaMax I\/O system\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(formerly GE Fanuc). It provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebox-style terminal base\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat hosts I\/O modules, enabling a modular and hot-swappable architecture. By separating the wiring from the electronics, it allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodule replacement and troubleshooting\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout disturbing field wiring, reducing system downtime.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-density installations, the IC200CHS002 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eup to 32-point I\/O modules\u003c\/strong\u003e. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e36 screw terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein two organized strips, integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ekeying dials\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent incorrect module insertion, a rugged backplane connector, and a secure latching mechanism for vibration-resistant mounting.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200CHS002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBox-style screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Terminals\u003c\/td\u003e\n\u003ctd\u003e36 (Two strips: A1–A18, B1–B18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Voltage\u003c\/td\u003e\n\u003ctd\u003e264 VAC (Operational) \/ 300 VAC (Transient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\/Common Capacity\u003c\/td\u003e\n\u003ctd\u003e8 A per terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Compatibility\u003c\/td\u003e\n\u003ctd\u003e16-point and 32-point VersaMax I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying\u003c\/td\u003e\n\u003ctd\u003eManual rotary dials for hardware coding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation and Field Wiring\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAdhere to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etorque specifications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor secure, gas-tight connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFour dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower\/common terminals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erated at 8 A allow efficient distribution without external blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density analog and discrete modules\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the IC200CHS002 be used with high-density analog modules?\u003c\/strong\u003e\u003cbr\u003eYes, its 36-terminal configuration supports 32-point discrete modules and multi-channel analog modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the keying dials?\u003c\/strong\u003e\u003cbr\u003eKeying dials prevent incorrect module insertion. By setting them to coordinates specified in the module manual, only the correct module type can be fully seated, protecting the system from electrical mismatches (e.g., 24V DC vs. 120V AC modules).\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746790977788,"sku":"IC200CHS002","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200CHS002.jpg?v=1771055433"},{"product_id":"ge-fanuc-versamax-ic200chs022-compact-i-o-terminal-carrier","title":"GE Fanuc VersaMax IC200CHS022 Compact I\/O Terminal Carrier","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS022\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a compact, high-density I\/O carrier from the GE Fanuc VersaMax family. It provides a secure mechanical and electrical foundation for VersaMax I\/O modules while integrating field wiring termination with the backplane communication interface.\u003c\/p\u003e\n\u003cp\u003eDesigned for modular, “hot-swappable” operation, the local box-style wiring allows field connections to remain intact even when I\/O modules are removed, reducing downtime during maintenance or system upgrades.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC200CHS022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax Compact I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC (via backplane\/power supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Style\u003c\/td\u003e\n\u003ctd\u003eLocal box with integrated screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Connection Type\u003c\/td\u003e\n\u003ctd\u003eIntegrated terminal block for direct wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eAll standard VersaMax I\/O and NIU modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Retention\u003c\/td\u003e\n\u003ctd\u003eSecure locking mechanism for module stability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Interface\u003c\/td\u003e\n\u003ctd\u003eHigh-density backplane connector for logic communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC200CHS022\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for distributed control environments with limited cabinet space, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRemote I\/O stations in water and wastewater treatment plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHVAC and building automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated assembly lines and compact manufacturing cells\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts local box wiring allows pre-wiring of cabinets, accelerating commissioning and minimizing operational downtime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this carrier include the power supply?\u003c\/strong\u003e\u003cbr\u003eNo. The IC200CHS022 is a passive wiring and mounting base. Power is supplied through the carrier from a VersaMax Power Supply module installed on the left side of the rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an I\/O module without disconnecting the wires?\u003c\/strong\u003e\u003cbr\u003eYes. Field wiring is terminated directly to the carrier, allowing I\/O modules to be snapped on or off without disturbing the electrical connections, supporting true hot-swappable operation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":48746791108860,"sku":"IC200CHS022","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200CHS0221.jpg?v=1770948452"},{"product_id":"ge-fanuc-emerson-ic200mdl940-relay-output-module","title":"GE Fanuc Emerson IC200MDL940 Relay Output Module","description":"\u003cp\u003eConfigured for deterministic process and discrete control execution within VersaMax I\/O platforms, the \u003cstrong\u003eGE Fanuc Emerson IC200MDL940\u003c\/strong\u003e (\u003cstrong\u003eIC200MDL940\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.51 kg (1.13 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Modular Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Backplane Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 points, individually isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Contact Form\u003c\/td\u003e\n\u003ctd\u003eNormally Open (Form A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e2.0 Amperes (0 to 125 VDC \/ 0 to 265 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density\u003c\/h3\u003e\n\u003cp\u003eThe hardware configuration maintains strict individual channel isolation across all 16 Form A relay outputs to suppress common-mode transient voltage spikes and eliminate ground loop interference between field actuators. Integration with high-density backplane bus communication architectures and deterministic industrial network protocols ensures rapid state propagation, low-latency command execution, and transparent diagnostic feedback across distributed control nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the restrictions regarding maximum current load limits across the relay output channels?\u003c\/p\u003e\n\u003cp\u003eA: Each individual output channel must operate within the specified maximum contact rating of 2.0 Amperes to prevent thermal degradation or contact welding under continuous load.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module interface with backplane bus communication and power distribution?\u003c\/p\u003e\n\u003cp\u003eA: The module mounts onto a standard VersaMax carrier base, drawing internal logic power directly from the backplane while routing field-side power through dedicated terminal connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module securely onto its designated VersaMax carrier base, ensuring proper physical alignment with backplane pins before locking the unit into place. Route heavy-load AC\/DC switching lines away from sensitive low-voltage analog or communication cables, and use shielded twisted-pair wiring where applicable. Terminate cable shielding and ground drain wires securely to the designated cabinet earth grounding bar.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":50364190392572,"sku":"IC200MDL940","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/IC200MDL9401.jpg?v=1784597680"},{"product_id":"versamax-ic200erm002-ge-fanuc-expansion-receiver-module","title":"General Electric IC200ERM002 VersaMax Expansion Receiver","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200ERM002 is a non-isolated expansion receiver module designed for the VersaMax PLC and I\/O system. This module facilitates the expansion of a VersaMax control system by connecting an expansion rack to a CPU or Network Interface Unit (NIU). It supports both multi-rack and single-ended expansion configurations, allowing for increased I\/O density and system flexibility in distributed control applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNon-isolated expansion receiver for VersaMax systems.\u003c\/li\u003e\n\u003cli\u003eSupports up to 7 expansion racks, with each rack accommodating up to 8 I\/O or special purpose modules.\u003c\/li\u003e\n\u003cli\u003eDual 26-pin female D-shell ports for flexible daisy-chaining or single-ended connections.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for 5 VDC power status and expansion bus communications.\u003c\/li\u003e\n\u003cli\u003eSupports a maximum expansion bus length of 15 meters (50 feet).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ERM002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eNon-isolated Expansion Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current (5 V)\u003c\/td\u003e\n\u003ctd\u003e70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current (3.3 V)\u003c\/td\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Ports\u003c\/td\u003e\n\u003ctd\u003e2 x 26-pin female D-shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Length\u003c\/td\u003e\n\u003ctd\u003e15 meters (50 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Expansion Capacity\u003c\/td\u003e\n\u003ctd\u003e7 racks (8 modules per rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePositioning:\u003c\/strong\u003e The IC200ERM002 must always be installed in the leftmost position (slot 0) of the expansion rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e In multi-rack configurations, the final expansion receiver in the daisy-chain must be fitted with an ACC201 terminator plug in the lower port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-Ended Mode:\u003c\/strong\u003e When connecting a single rack directly to a CPU\/NIU without a transmitter (max distance 1 meter), use the CBL600 cable; no terminator is required in this specific configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowering:\u003c\/strong\u003e Ensure a compatible power supply is mounted on the expansion receiver to provide power to the modules within the rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Observe standard ESD precautions when handling the module. Ensure the system is powered down before inserting or removing the module from the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAutomotive manufacturing and paint shop control systems.\u003c\/li\u003e\n\u003cli\u003eOil and gas distributed control and machinery monitoring.\u003c\/li\u003e\n\u003cli\u003ePetrochemical reactor shutdown and critical control loops.\u003c\/li\u003e\n\u003cli\u003eFire and gas detection systems.\u003c\/li\u003e\n\u003cli\u003ePower transmission and steam turbine control.\u003c\/li\u003e\n\u003cli\u003eMunicipal water treatment and environmental projects.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200ERM002?\u003c\/h3\u003e\u003cp\u003eThe GE IC200ERM002 is a VersaMax non-isolated expansion receiver module designed to extend the I\/O capabilities of VersaMax PLC or Network Interface Unit (NIU) stations.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum expansion capacity?\u003c\/h3\u003e\u003cp\u003eIt supports up to 7 expansion racks, each accommodating up to 8 I\/O modules or dedicated modules.\u003c\/p\u003e\u003ch3\u003eWhat are the expansion port details?\u003c\/h3\u003e\u003cp\u003eThe module features two 26-pin female D-shell connectors. The upper port is for the inbound expansion cable, while the lower port is for daisy-chaining to the next rack or attaching a terminator plug.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum cable length?\u003c\/h3\u003e\u003cp\u003eThe maximum cable length for the expansion bus when using the IC200ERM002 is 15 meters (50 feet).\u003c\/p\u003e\u003ch3\u003eWhat is the difference between IC200ERM001 and IC200ERM002?\u003c\/h3\u003e\u003cp\u003eThe IC200ERM001 is an isolated expansion receiver, whereas the IC200ERM002 is a non-isolated version.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50517451374844,"sku":"IC200ERM002","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8da6a998-8f93-48c6-a77a-cabc8f212190.jpg?v=1784769480"},{"product_id":"ic200pns002-ge-fanuc-versamax-profinet-network-scanner","title":"General Electric IC200PNS002 VersaMax PROFINET Scanner Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200PNS002 is a high-performance PROFINET Scanner (PNS) module within the VersaMax series. Designed for robust industrial communication, this module acts as a bridge between VersaMax I\/O stations and a PROFINET network. It features integrated fiber-optic connectivity and a built-in switch, making it ideal for environments requiring high immunity to electromagnetic interference (EMI). The module supports up to 2880 bytes of total I\/O data and is compatible with various network topologies, including daisy-chain, star, and ring configurations.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual 100 Mbps SC-Duplex Multi-Mode Fiber (MMF) ports.\u003c\/li\u003e\n\u003cli\u003eSupports Media Redundancy Protocol (MRP) in client mode for ring topology reliability.\u003c\/li\u003e\n\u003cli\u003eIntegrated switch functionality for flexible network architecture.\u003c\/li\u003e\n\u003cli\u003eSupports redundant power supplies with hot-swap capability for de-energized units.\u003c\/li\u003e\n\u003cli\u003eFirmware field-upgradable via dedicated USB port.\u003c\/li\u003e\n\u003cli\u003eStandard PROFINET alarm and diagnostic reporting for efficient troubleshooting.\u003c\/li\u003e\n\u003cli\u003eConfiguration support via Classless InterDomain Routing (CIDR).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUrban infrastructure including water supply, sewage treatment, and tunnel ventilation.\u003c\/li\u003e\n\u003cli\u003eHigh-EMI environments such as power substations and large motor drive stations.\u003c\/li\u003e\n\u003cli\u003ePetrochemical facilities requiring fiber-optic isolation in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eLong-distance I\/O communication in paper and steel mills.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PNS002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003ePROFINET Scanner (PNS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Ports\u003c\/td\u003e\n\u003ctd\u003e2 x SC-Duplex (Multi-Mode Fiber)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePROFINET Support\u003c\/td\u003e\n\u003ctd\u003eVersion 2.2 Class A IO-Device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.10A at 5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Data\u003c\/td\u003e\n\u003ctd\u003e2880 Bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the module is installed in a clean, dry environment within the specified temperature range.\u003c\/li\u003e\n\u003cli\u003eThe module features an integrated carrier; no external carrier is required for mounting.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure fiber-optic cables are routed away from high-voltage power lines to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the PROFINET device name is correctly assigned via the network port using a DCP-compliant tool.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables and proper grounding practices to minimize potential EMI\/RFI impact on the control cabinet.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200PNS002?\u003c\/h3\u003e\u003cp\u003eThe IC200PNS002 serves as a PROFINET Scanner that connects VersaMax I\/O modules to a PROFINET network via fiber-optic media.\u003c\/p\u003e\u003ch3\u003eCan the USB port be used for configuration?\u003c\/h3\u003e\u003cp\u003eNo, the USB port on the IC200PNS002 is reserved exclusively for firmware updates. Network configuration and device naming must be performed through the fiber-optic ports using Proficy Machine Edition.\u003c\/p\u003e\u003ch3\u003eDoes the module support redundant power?\u003c\/h3\u003e\u003cp\u003eYes, the module supports redundant power supplies, and the secondary supply can be hot-swapped if it is de-energized.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50517505212668,"sku":"IC200PNS002","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_da496713-e2fd-4956-bd3e-b0880786e013.jpg?v=1784770372"},{"product_id":"ic200erm001-ge-fanuc-versamax-isolated-expansion-receiver-module","title":"General Electric IC200ERM001 VersaMax Isolated Expansion Receiver Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200ERM001 is an isolated Expansion Receiver Module designed for the VersaMax PLC and I\/O station product line. This module is essential for extending the I\/O bus, allowing for the connection of remote expansion racks up to 2,460 feet (750 meters) away from the main controller. It provides 500VDC isolation, ensuring robust signal integrity in industrial environments. The module must be used in conjunction with an Expansion Transmitter Module (such as the IC200ETM001) located at the main PLC rack.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIsolated expansion interface for VersaMax I\/O systems.\u003c\/li\u003e\n\u003cli\u003eSupports daisy-chaining of up to 7 expansion racks.\u003c\/li\u003e\n\u003cli\u003eEquipped with two 26-pin female D-shell ports for upstream and downstream communication.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED indicators for real-time power and expansion bus status monitoring.\u003c\/li\u003e\n\u003cli\u003eProvides operating power to modules within the expansion rack via the backplane.\u003c\/li\u003e\n\u003cli\u003e500VDC isolation for enhanced noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFactory Automation: Synchronizes multiple machines across extended production lines.\u003c\/li\u003e\n\u003cli\u003eMaterial Handling: Facilitates control for large-scale conveyor systems and sorters.\u003c\/li\u003e\n\u003cli\u003eAutomotive Plants: Supports high-speed discrete I\/O for robotic assembly and painting cells.\u003c\/li\u003e\n\u003cli\u003eProcess Control: Enables modular distributed control for water treatment and light chemical processing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ERM001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eIsolated Expansion Receiver Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE Fanuc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Output Voltage\u003c\/td\u003e\n\u003ctd\u003e3.3V to 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e2 x 26-pin Female D-Shell Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35mm x 7.5mm DIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe module must be installed in the leftmost position (Slot 0) of the expansion rack.\u003c\/li\u003e\n\u003cli\u003eMount all modules and carriers on the same section of 35mm x 7.5mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eEnsure the DIN rail has a conductive (unpainted) finish to facilitate proper grounding.\u003c\/li\u003e\n\u003cli\u003eFor optimal stability, secure the DIN rail to the panel using screws spaced approximately 6 inches (15.24 cm) apart.\u003c\/li\u003e\n\u003cli\u003eThe module snaps onto the DIN rail without the need for specialized tools.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before installing or removing modules to prevent electrical damage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200ERM001 used for?\u003c\/h3\u003e\u003cp\u003eThe GE IC200ERM001 is an isolated Expansion Receiver Module used within the VersaMax PLC system to extend I\/O capabilities to remote racks.\u003c\/p\u003e\u003ch3\u003eHow many expansion racks can I connect?\u003c\/h3\u003e\u003cp\u003eThe system supports up to 7 expansion racks per system, for a total of 8 racks including the main rack.\u003c\/p\u003e\u003ch3\u003eDoes the IC200ERM001 require external power?\u003c\/h3\u003e\u003cp\u003eNo, the module is powered directly through the backplane (3.3V-5V).\u003c\/p\u003e\u003ch3\u003eWhat is the maximum distance for expansion?\u003c\/h3\u003e\u003cp\u003eExpansion racks can be located up to 750 meters (approximately 2460 feet) from the main rack.\u003c\/p\u003e\u003ch3\u003eWhat do the LED indicators show?\u003c\/h3\u003e\u003cp\u003eThe LEDs provide visual status updates for the internal power supply and the health of the expansion bus communication.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50601264709884,"sku":"IC200ERM001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_21d14a44-348f-426d-8bf1-b9a8b07ada9e.jpg?v=1784856184"},{"product_id":"ic200alg264-ge-fanuc-versamax-analog-input-module","title":"General Electric IC200ALG264 VersaMax 15-Point Analog Current Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC200ALG264 is a 15-point analog current input module designed for the GE VersaMax PLC series. This module provides high-density signal processing for industrial automation applications, supporting both 4-20 mA and 0-20 mA current loops. It features 15 single-ended inputs grouped together, offering a robust solution for monitoring process variables such as pressure, flow, or temperature sensors in a compact footprint.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e15 single-ended analog input channels.\u003c\/li\u003e\n\u003cli\u003eSupports 4-20 mA and 0-20 mA input signals.\u003c\/li\u003e\n\u003cli\u003e15-bit resolution for precise analog-to-digital conversion.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostic capabilities, including open-wire detection for 4-20 mA loops.\u003c\/li\u003e\n\u003cli\u003eStatus LED for module health monitoring.\u003c\/li\u003e\n\u003cli\u003eConfigurable input range via terminal jumpers.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e15 single-ended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0-20 mA \/ 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e100 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e7.5 ms (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.3% typical, 1% maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Response\u003c\/td\u003e\n\u003ctd\u003e24 Hz +\/- 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC backplane power is disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eMount the module onto the VersaMax I\/O carrier, ensuring proper alignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eFor 4-20 mA operation, ensure no terminal jumper is installed; for 0-20 mA, install the required terminal jumper.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eGround the cable shields at the sensor end or the module end according to site-specific grounding practices to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module to allow for proper heat dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat signals does the IC200ALG264 support?\u003c\/h3\u003e\u003cp\u003eThe module supports 4-20 mA and 0-20 mA analog current signals. The selection is determined by the presence of a terminal jumper.\u003c\/p\u003e\u003ch3\u003eDoes this module provide open-wire detection?\u003c\/h3\u003e\u003cp\u003eYes, the module includes diagnostic features such as open-wire detection specifically for 4-20 mA input configurations.\u003c\/p\u003e\u003ch3\u003eHow is the module powered?\u003c\/h3\u003e\u003cp\u003eThe module is powered directly from the PLC backplane, consuming a maximum of 100 mA at 5 VDC.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50642566283516,"sku":"IC200ALG264","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_834e513c-85cc-46de-8f14-40687ce4a833.jpg?v=1784892322"},{"product_id":"ic200mdl740-ge-fanuc-versamax-discrete-output-module","title":"General Electric IC200MDL740 VersaMax Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200MDL740 is a 16-point discrete output module designed for the VersaMax I\/O system. This module provides 16 sourcing-type (positive logic) outputs, operating with a nominal 12\/24 VDC supply. It is engineered for industrial automation applications requiring reliable, high-speed switching of field devices such as solenoids, contactors, and indicators. The module features a compact, modular design that supports hot-swapping, allowing for maintenance and replacement without interrupting the backplane power or requiring extensive rewiring.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-point sourcing (positive logic) discrete output configuration.\u003c\/li\u003e\n\u003cli\u003eSupports 12\/24 VDC nominal external power supply (10.2 to 30 VDC range).\u003c\/li\u003e\n\u003cli\u003e0.5 Amp per point output current capacity.\u003c\/li\u003e\n\u003cli\u003eFast response times: 0.2 ms maximum ON and 1.0 ms maximum OFF.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for real-time monitoring of each output point.\u003c\/li\u003e\n\u003cli\u003eHot-swappable design for reduced downtime during maintenance.\u003c\/li\u003e\n\u003cli\u003eOptical isolation between the field side and the backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePackaging and bottling lines for solenoid and actuator control.\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems, including conveyors, sorters, and palletizers.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment facilities for valve and pump control.\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O nodes in energy and oil\/gas infrastructure.\u003c\/li\u003e\n\u003cli\u003eGeneral industrial and commercial automation control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete (Sourcing\/Positive Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e10.2 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e45 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Leakage Current\u003c\/td\u003e\n\u003ctd\u003e0.5 mA at 30 VDC (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eNo internal fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The module is designed for rack-mounting using compatible VersaMax carriers. Ensure the carrier is securely fastened to the DIN rail or panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the positive side of the external DC supply to the DC+ terminal and the negative side to the DC- terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Loads:\u003c\/strong\u003e When driving inductive loads such as solenoids or motor starters, external suppression circuits (e.g., flyback diodes) must be installed to protect the module from voltage spikes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swapping:\u003c\/strong\u003e The module supports hot insertion\/removal; however, ensure proper ESD precautions are taken when handling the device.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShorting Bars:\u003c\/strong\u003e If additional bussed terminals are required, use a shorting bar with a minimum 2A current-carrying capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200MDL740 module?\u003c\/h3\u003e\u003cp\u003eIt is a 16-point, 24VDC positive logic (sourcing) output module from the VersaMax family. It switches loads to the positive side of the DC supply.\u003c\/p\u003e\u003ch3\u003eWhat is the required power supply?\u003c\/h3\u003e\u003cp\u003eThe module operates with a 24VDC nominal external power supply, with an operating range of 10.2 to 30VDC.\u003c\/p\u003e\u003ch3\u003eDoes the IC200MDL740 provide isolation?\u003c\/h3\u003e\u003cp\u003eThe IC200MDL740 provides optical isolation between the field side and the backplane.\u003c\/p\u003e\u003ch3\u003eWhat is the response time?\u003c\/h3\u003e\u003cp\u003eThe output response time is 0.2 milliseconds maximum for \"on\" and 1.0 millisecond maximum for \"off\".\u003c\/p\u003e\u003ch3\u003eWhat is the backplane current consumption?\u003c\/h3\u003e\u003cp\u003eIt consumes a maximum of 45mA from the 5V output power supply.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50643749667068,"sku":"IC200MDL740","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_94b05a83-c431-4c62-9365-c751f5a17232.jpg?v=1784946178"},{"product_id":"ic200gbi001-ge-fanuc-versamax-genius-network-interface-unit","title":"General Electric IC200GBI001 VersaMax Genius Network Interface Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200GBI001 is a Genius Network Interface Unit (NIU) designed for the VersaMax Programmable Logic Controller (PLC) product family. This module serves as a Genius slave device, enabling the integration of VersaMax I\/O modules into a distributed I\/O architecture. It facilitates communication between the Genius bus and the local I\/O rack, supporting high-speed data exchange for industrial automation applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports Genius network communication at 38.4, 76.8, and 153.6 Kbaud (standard) and 153.6 Kbaud (extended).\u003c\/li\u003e\n\u003cli\u003eManages up to 8 I\/O modules per rack and up to 8 expansion racks, for a total capacity of 64 I\/O modules.\u003c\/li\u003e\n\u003cli\u003eProvides 1024 points of discrete input and 1024 points of discrete output memory.\u003c\/li\u003e\n\u003cli\u003eSupports 128 bytes of analog input and 128 bytes of analog output memory.\u003c\/li\u003e\n\u003cli\u003eEquipped with dual Genius bus terminals for primary and redundant network connections.\u003c\/li\u003e\n\u003cli\u003eCompatible with Series 90-70, PACSystem RX7i, and PACSystem RX3i controller platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnergy Management Systems: Monitoring and optimization of power consumption.\u003c\/li\u003e\n\u003cli\u003eChemical Industry: High-precision process control and monitoring.\u003c\/li\u003e\n\u003cli\u003eNumerical Control Machinery (CNC): High-performance control for machine tools.\u003c\/li\u003e\n\u003cli\u003eRail Transportation: Auxiliary automation control for transit systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200GBI001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Inputs\/Bus Scan\u003c\/td\u003e\n\u003ctd\u003e128 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Memory\u003c\/td\u003e\n\u003ctd\u003e1024 points (In\/Out)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Memory\u003c\/td\u003e\n\u003ctd\u003e128 bytes (In\/Out)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e250 mA @ 5VDC; 10 mA @ 3.3VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Addressing\u003c\/td\u003e\n\u003ctd\u003eRotary switches (0-31)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always remove power from the system before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is properly seated in the VersaMax carrier. Use the provided connector cover on the last carrier in the rack to protect pins from ESD and physical damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e The module features dual terminals for daisy-chain topology. Install a terminating resistor (75, 100, 120, or 150-ohm) at both ends of the communication cable across terminals Serial 1 and 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e To minimize electrical noise, insulate shield drain wires with tubing to prevent shorting between Shield In, Shield Out, or signal wires.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200GBI001?\u003c\/h3\u003e\u003cp\u003eThe GE IC200GBI001 is a Genius Network Interface Unit (NIU) for the VersaMax PLC system, acting as a gateway for distributed I\/O.\u003c\/p\u003e\u003ch3\u003eWhat are the power requirements?\u003c\/h3\u003e\u003cp\u003eThe unit requires 5VDC at 250mA and 3.3VDC at 10mA.\u003c\/p\u003e\u003ch3\u003eHow is the module addressed?\u003c\/h3\u003e\u003cp\u003eThe module uses two rotary switches located on the unit to set the Serial Bus Address (SBA) from 0 to 31.\u003c\/p\u003e\u003ch3\u003eHow many modules and racks are supported?\u003c\/h3\u003e\u003cp\u003eIt supports up to 8 I\/O modules per rack and up to 8 expansion racks, allowing for a maximum of 64 I\/O modules.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50643766083836,"sku":"IC200GBI001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_539b425f-9324-4dbf-b96c-0c05d4abb722.jpg?v=1784947829"},{"product_id":"ge-fanuc-versamax-ic200cpu001-central-processing-unit-module","title":"General Electric IC200CPU001 VersaMax CPU Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200CPU001 is a high-performance Central Processing Unit (CPU) module designed for the VersaMax PLC system. This configurable CPU provides robust control capabilities for industrial automation applications, supporting both floating-point math and standard logic execution. It features integrated memory storage using both RAM and Flash, ensuring reliable program retention and operational flexibility.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessing Speed:\u003c\/strong\u003e Executes boolean logic at 1.8 ms per 1K of instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e Includes 34K bytes of configurable memory for programs, registers, and I\/O analog words, with a total of 384K bytes of system memory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e Equipped with one RS232 port and one RS485 port for versatile connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support:\u003c\/strong\u003e Supports SNP Slave, Modbus RTU Slave, and Serial I\/O protocols.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Clock:\u003c\/strong\u003e Features a battery-backed Real-Time Clock (RTC) with an accuracy of 100 ppm (+\/- 9 seconds per day).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Compatible with Ladder Diagram and Instruction List programming languages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe IC200CPU001 is suitable for a wide range of industrial control tasks, including machine control, process monitoring, and distributed I\/O management within the VersaMax platform.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CPU001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Type\u003c\/td\u003e\n\u003ctd\u003eSystem Flash, Battery-backed RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfigurable Memory\u003c\/td\u003e\n\u003ctd\u003e34K Bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003e1.8 ms \/ 1K logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e140 mA @ 5V, 100 mA @ 3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e2048 Inputs \/ 2048 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e1x RS232, 1x RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Ensure proper ESD precautions are taken when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The module is designed for standard VersaMax backplane installation. Ensure it is fully seated and locked into the rack before applying power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e Verify that the backplane power supply is within the specified voltage range before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cables for serial communication to minimize EMI interference. Ensure proper grounding of the control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Power down the system before removing or inserting the module to avoid electrical faults.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat programming software is required for this CPU?\u003c\/strong\u003e The IC200CPU001 is programmed using GE's VersaPro or Machine Edition software, supporting Ladder Diagram and Instruction List languages.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module support floating-point math?\u003c\/strong\u003e Yes, the IC200CPU001 supports floating-point data and calculations, making it suitable for applications requiring complex mathematical operations.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50644523778300,"sku":"IC200CPU001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_713363b0-4aa4-411a-9ea1-bbe847c5531a.jpg?v=1784966431"},{"product_id":"ic200udr005-ge-fanuc-versamax-expandable-micro-plc-module","title":"General Electric IC200UDR005-BD VersaMax Micro PLC Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200UDR005-BD is a high-performance VersaMax Micro PLC controller designed for compact industrial automation applications. This all-in-one unit integrates processing, I\/O, and power supply capabilities into a single, space-saving footprint, making it ideal for small-to-medium scale machine control and process monitoring tasks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntegrated 28-point I\/O configuration for versatile control.\u003c\/li\u003e\n\u003cli\u003e16 discrete 24 VDC inputs for sensor and switch interfacing.\u003c\/li\u003e\n\u003cli\u003e11 relay outputs capable of handling 2 A loads for flexible actuator control.\u003c\/li\u003e\n\u003cli\u003eDedicated 24 VDC output channel for auxiliary device power.\u003c\/li\u003e\n\u003cli\u003eWide-range 100-240 VAC power supply input for global compatibility.\u003c\/li\u003e\n\u003cli\u003eCompact design optimized for DIN-rail mounting in control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UDR005-BD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax Micro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Points\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Inputs\u003c\/td\u003e\n\u003ctd\u003e16 (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Outputs\u003c\/td\u003e\n\u003ctd\u003e11 (Normally-Open, 2 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Outputs\u003c\/td\u003e\n\u003ctd\u003e1 (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the controller is mounted on a standard DIN rail in a clean, dry environment with adequate ventilation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance around the unit to allow for heat dissipation and cable routing.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before connecting or disconnecting any I\/O wiring or communication cables.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for I\/O signals to minimize electromagnetic interference (EMI) in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the supply voltage matches the 100-240 VAC nominal requirement before applying power.\u003c\/li\u003e\n\u003cli\u003eObserve correct polarity when wiring the 24 VDC input and output circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200UDR005-BD?\u003c\/h3\u003e\u003cp\u003eThis module serves as a compact Programmable Logic Controller (PLC) capable of managing discrete inputs and relay-based outputs for machine automation and process control.\u003c\/p\u003e\u003ch3\u003eDoes this unit require an external power supply?\u003c\/h3\u003e\u003cp\u003eNo, the IC200UDR005-BD features an integrated 100-240 VAC power supply, allowing it to be powered directly from standard AC mains.\u003c\/p\u003e\u003ch3\u003eCan the relay outputs handle high-current loads?\u003c\/h3\u003e\u003cp\u003eThe relay outputs are rated for 2 A. For loads exceeding this current, it is recommended to use an external interposing relay to protect the internal contacts of the PLC.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50644533084412,"sku":"IC200UDR005","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_683781a3-e52f-4ba3-85a3-5a0d47d87f4f.jpg?v=1784966907"},{"product_id":"ic200alg620-ge-fanuc-versamax-analog-input-module","title":"General Electric IC200ALG620-CA VersaMax 4-Point RTD Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200ALG620-CA is a high-performance analog input module designed for the VersaMax I\/O system. This module provides four channels dedicated to RTD (Resistance Temperature Detector) and resistance measurements, offering high-precision data acquisition for industrial automation processes. It supports both 3-wire and 4-wire RTD configurations, ensuring compatibility with a wide range of temperature sensing instrumentation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4-channel RTD\/Resistance input capability\u003c\/li\u003e\n\u003cli\u003e16-bit resolution for high-accuracy signal processing\u003c\/li\u003e\n\u003cli\u003eSupports 3-wire and 4-wire RTD wiring configurations\u003c\/li\u003e\n\u003cli\u003eResistance input ranges: 0-500 Ohms and 0-3000 Ohms\u003c\/li\u003e\n\u003cli\u003eRobust isolation: 1500 VAC (Input to Frame) and 250 VAC (Input to Logic)\u003c\/li\u003e\n\u003cli\u003eFast update rate of 210 milliseconds\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is engineered for industrial environments requiring reliable temperature monitoring. Typical applications include process control systems, HVAC monitoring, chemical processing, and power generation plant instrumentation where RTD sensors are utilized for thermal management and process feedback.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG620-CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits (15 bits plus sign)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e210 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e125 mA (5V); 125 mA (3.3V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (at 25 degC)\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.15% (resistance measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Lead Resistance\u003c\/td\u003e\n\u003ctd\u003e5 Ohms per lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the VersaMax backplane power is disconnected before installing or removing the module.\u003c\/li\u003e\n\u003cli\u003eMount the module onto a standard DIN rail or compatible VersaMax carrier.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for RTD inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to ensure signal integrity and module protection.\u003c\/li\u003e\n\u003cli\u003eEnsure the ambient temperature remains within the specified 0 to 60 degC range to prevent thermal degradation.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to avoid damage to sensitive internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat types of RTDs are compatible with the IC200ALG620-CA?\u003c\/strong\u003e\u003cbr\u003eThe module is designed to work with 3-wire and 4-wire RTD configurations, supporting resistance ranges of 0-500 Ohms and 0-3000 Ohms.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the resolution of this module?\u003c\/strong\u003e\u003cbr\u003eThe module provides 16-bit resolution, specifically 15 bits plus sign.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50646445392124,"sku":"IC200ALG620","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_22a1197c-1044-4f28-9a70-b79ca558f27a.jpg?v=1785034217"},{"product_id":"ic200pbi001-ge-fanuc-versamax-network-interface-unit","title":"General Electric IC200PBI001 VersaMax Profibus-DP Network Interface Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc\/Emerson IC200PBI001 is a high-performance Network Interface Unit (NIU) designed for the VersaMax I\/O system. It functions as a slave device on a Profibus-DP network, enabling seamless integration between the network master and local VersaMax I\/O modules. The module automatically detects network baud rates and manages data exchange, diagnostics, and module configuration for up to 64 I\/O modules per station.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports Profibus-DP network communication with automatic baud rate detection from 9.6 Kbaud to 12 Mbaud.\u003c\/li\u003e\n\u003cli\u003eTotal I\/O data capacity of 375 bytes, with a maximum of 244 bytes for input or output.\u003c\/li\u003e\n\u003cli\u003eSupports up to 64 I\/O modules per NIU station.\u003c\/li\u003e\n\u003cli\u003eIntegrated self-diagnostics with an amber FAULT LED for status monitoring.\u003c\/li\u003e\n\u003cli\u003eAutoconfiguration capability upon power-up to ensure correct system mapping.\u003c\/li\u003e\n\u003cli\u003eStandard 9-pin D-sub connector for Profibus-DP interface.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PBI001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Type\u003c\/td\u003e\n\u003ctd\u003eProfibus-DP (Slave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 Kbaud to 12 Mbaud (Auto-detect)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Data Capacity\u003c\/td\u003e\n\u003ctd\u003e375 bytes max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Modules\u003c\/td\u003e\n\u003ctd\u003e64 per NIU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e250 mA at 5V DC; 10 mA at 3.3V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Address\u003c\/td\u003e\n\u003ctd\u003e1 to 125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to 60 degC (32 degF to 140 degF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the NIU from the backplane.\u003c\/li\u003e\n\u003cli\u003eMount the module securely on the VersaMax I\/O rack; ensure proper seating to maintain backplane communication.\u003c\/li\u003e\n\u003cli\u003eUse a standard shielded Profibus-DP cable connected to the 9-pin D-sub port to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation around the module to prevent overheating, adhering to the 0-60 degC operating range.\u003c\/li\u003e\n\u003cli\u003eThe module performs an autoconfiguration check upon power-up; ensure all modules are properly seated to avoid fault conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200PBI001?\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc\/Emerson IC200PBI001 is a Profibus-DP Network Interface Unit (NIU) for the VersaMax series, designed to act as a slave device on a Profibus network while managing local I\/O modules.\u003c\/p\u003e\u003ch3\u003eWhat is the function of the IC200PBI001?\u003c\/h3\u003e\u003cp\u003eThe IC200PBI001 acts as a slave on a Profibus-DP network, allowing a master device (like a PLC) to control a set of VersaMax input\/output modules connected to it.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum I\/O data capacity of IC200PBI001?\u003c\/h3\u003e\u003cp\u003eThis module supports a maximum of 375 bytes of I\/O data, which can contain up to 244 bytes of input or 244 bytes of output.\u003c\/p\u003e\u003ch3\u003eWhat is the IC200PBI001 power requirement?\u003c\/h3\u003e\u003cp\u003eThe NIU draws power through the backplane, requiring 250mA at 5V DC and 10mA at 3.3V DC.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50647501013244,"sku":"IC200PBI001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3c0e8341-9713-4072-8c30-666dc95b0cfa.jpg?v=1785060461"},{"product_id":"ge-fanuc-ic200pwr001-versamax-power-supply-board","title":"General Electric IC200PWR001 VersaMax 24VDC Power Supply Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200PWR001 is a 24VDC power supply input module belonging to the VersaMax PLC series. This module is engineered to provide essential backplane power to CPU modules, Network Interface Units (NIUs), and various I\/O modules within a VersaMax station. It is designed for applications requiring a reliable 24VDC input source, converting it into the stable 5VDC and 3.3VDC levels required for internal logic and communication operations.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInput Voltage: 18 to 30VDC (24VDC nominal).\u003c\/li\u003e\n\u003cli\u003eTotal Output Capacity: 1.5A combined across 5VDC and 3.3VDC rails.\u003c\/li\u003e\n\u003cli\u003eVersatile Mounting: Functions as a main power supply when mounted on a CPU or NIU carrier, or as a supplemental supply when installed on a Power Supply Booster Carrier.\u003c\/li\u003e\n\u003cli\u003eIntegrated Protection: Includes built-in short circuit, overload, and reverse polarity protection.\u003c\/li\u003e\n\u003cli\u003eCompact Design: Optimized for the VersaMax modular rack system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAutomotive and Consumer Goods: Powers PLC racks and I\/O clusters for production line automation.\u003c\/li\u003e\n\u003cli\u003eWater and Wastewater Management: Provides stable DC power for remote telemetry and communication modules.\u003c\/li\u003e\n\u003cli\u003eFood and Pharmaceutical Processing: Supports automated packaging and sorting systems requiring precise power delivery.\u003c\/li\u003e\n\u003cli\u003eEnergy and Utilities: Powers RTU gateways and control protection panels in power generation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PWR001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 30VDC (24VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e11W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5VDC, 3.3VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e1.5A (Total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.3V Output Limit\u003c\/td\u003e\n\u003ctd\u003e0.25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e20A at 24VDC \/ 25A at 30VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort circuit, Overload, Reverse polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003eUp to 10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the carrier.\u003c\/li\u003e\n\u003cli\u003eThe module must be seated firmly onto the CPU, NIU, or Power Supply Booster carrier to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the module to prevent thermal buildup; ensure the ambient temperature remains within the rated operating range.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges for the 24VDC input connections to minimize voltage drop.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure the input power source is properly grounded according to local electrical codes to mitigate EMI\/RFI interference.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200PWR001?\u003c\/h3\u003e\u003cp\u003eThe GE VersaMax IC200PWR001 is a 24VDC power supply module designed to provide backplane power to CPU, NIU, and I\/O modules in a VersaMax system.\u003c\/p\u003e\u003ch3\u003eWhat does it mean if the PWR LED is off?\u003c\/h3\u003e\u003cp\u003eThis typically indicates that the module is not receiving the required 18–30 VDC input power, or the module has experienced an internal failure.\u003c\/p\u003e\u003ch3\u003eCan this power supply operate with AC inputs?\u003c\/h3\u003e\u003cp\u003eNo, the IC200PWR001 is designed exclusively for 18–30 VDC input. It is part of the VersaMax DC-input power supply range.\u003c\/p\u003e\u003ch3\u003eWhat happens if I exceed 1.5 Amps of output?\u003c\/h3\u003e\u003cp\u003eThe module features internal overload protection. To ensure reliable operation, the combined current draw from the 3.3VDC and 5VDC outputs must not exceed 1.5A.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50647742251260,"sku":"IC200PWR001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_cb4ce3ce-5aa6-4c71-9723-b9c1ae1f2cdb.jpg?v=1785065022"},{"product_id":"ge-fanuc-versamax-ic200mdd843-discrete-mixed-module","title":"GE Fanuc IC200MDD843 VersaMax Discrete Mixed I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC200MDD843 is a VersaMax series discrete mixed I\/O module designed for industrial automation control systems. This module provides a combination of digital inputs and outputs to facilitate flexible signal processing within the VersaMax PLC architecture. It is engineered to handle 16 total I\/O points, supporting integrated control tasks across various manufacturing and process applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 total I\/O points: 10 inputs and 6 outputs.\u003c\/li\u003e\n\u003cli\u003ePositive logic (sourcing) input configuration.\u003c\/li\u003e\n\u003cli\u003eHigh-capacity output current rating of 8 A.\u003c\/li\u003e\n\u003cli\u003eMaximum response speed of 10 ms for time-sensitive control operations.\u003c\/li\u003e\n\u003cli\u003ePowered directly via the rack-mounted backplane with support for additional power sources.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe IC200MDD843 is typically utilized in GE Fanuc VersaMax PLC systems for machine control, assembly line automation, and discrete manufacturing processes where a mix of input sensing and output switching is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDD843\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003ePositive Logic \/ Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Speed\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eRack-Mounted Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system is powered down before installing or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is securely seated in the VersaMax rack to ensure proper backplane communication.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded cabling for I\/O signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module to allow for proper heat dissipation and ventilation.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD (Electrostatic Discharge) precautions to prevent damage to internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200MDD843?\u003c\/h3\u003e\u003cp\u003eThis module acts as a mixed discrete I\/O interface for the VersaMax system, allowing the controller to read 10 digital inputs and drive 6 digital outputs simultaneously.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eThe module is powered via the rack backplane, though it supports additional power source configurations as per the system design requirements.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50708707999996,"sku":"IC200MDD843","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c4a69b49-fb7e-4268-ab7d-d260a197fad8.jpg?v=1785136132"},{"product_id":"ge-fanuc-versamax-ic200mdl650-discrete-input-module","title":"General Electric IC200MDL650 VersaMax 32-Point Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC200MDL650 is a high-density 32-point discrete input module designed for the GE VersaMax I\/O platform. This module provides reliable signal acquisition for industrial control systems, supporting both positive and negative logic wiring configurations. It is organized into four groups of eight input channels each, allowing for flexible integration with various field devices such as limit switches, proximity sensors, pushbuttons, and auxiliary contacts.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32 discrete input channels arranged in four groups of eight.\u003c\/li\u003e\n\u003cli\u003eSupports both positive and negative logic configurations.\u003c\/li\u003e\n\u003cli\u003eConfigurable input filtering (0 ms, 1.0 ms default, or 7.0 ms) to suppress noise and eliminate mechanical contact bounce.\u003c\/li\u003e\n\u003cli\u003eHigh-density design suitable for space-constrained control cabinets.\u003c\/li\u003e\n\u003cli\u003eGroup-to-group isolation rated at 250 VAC continuous and 1500 VAC for 1 minute.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePump station control and monitoring of start\/stop status.\u003c\/li\u003e\n\u003cli\u003eHydropower station signal acquisition for turbines and circuit breakers.\u003c\/li\u003e\n\u003cli\u003eIntelligent fire-fighting water supply systems using pressure and level switches.\u003c\/li\u003e\n\u003cli\u003eThermal control and conveyor logic for industrial furnace applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Voltage\u003c\/td\u003e\n\u003ctd\u003e15 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Current\u003c\/td\u003e\n\u003ctd\u003e2.0 to 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Current\u003c\/td\u003e\n\u003ctd\u003e0 to 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e50 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10k Ohms (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Times\u003c\/td\u003e\n\u003ctd\u003e0 ms, 1.0 ms (default), 7.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system is powered down before installing or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eMount the module on a standard DIN rail or compatible VersaMax rack system, ensuring secure seating to maintain backplane connectivity.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for input signals to minimize electromagnetic interference (EMI) in high-noise environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper wire routing to separate signal lines from high-voltage power cables.\u003c\/li\u003e\n\u003cli\u003eObserve correct polarity when wiring for positive or negative logic configurations.\u003c\/li\u003e\n\u003cli\u003eHandle with care using ESD-safe practices to prevent damage to sensitive internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200MDL650?\u003c\/h3\u003e\u003cp\u003eThe GE IC200MDL650 is a 32-point, 24VDC discrete input module from the VersaMax PLC series, used to interface field devices with the control system.\u003c\/p\u003e\u003ch3\u003eWhat is the input voltage range?\u003c\/h3\u003e\u003cp\u003eThe module operates with a 24 VDC nominal voltage, with an input range of 0 to 30 VDC.\u003c\/p\u003e\u003ch3\u003eHow are the inputs configured?\u003c\/h3\u003e\u003cp\u003eThe 32 inputs are organized into four groups of eight channels each, supporting both positive and negative logic wiring.\u003c\/p\u003e\u003ch3\u003eCan the input response time be adjusted?\u003c\/h3\u003e\u003cp\u003eYes, users can configure input filter times via the CPU software to 0 ms, 1.0 ms (default), or 7.0 ms to filter out noise or contact bounce.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50708732018940,"sku":"IC200MDL650","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ecd5e19e-bbad-4bef-b0f1-c62e8556e6cb.jpg?v=1785137254"},{"product_id":"ge-ic200mdl742-versamax-discrete-output-module","title":"General Electric IC200MDL742 VersaMax 32-Point Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200MDL742 is a high-density discrete output module designed for the VersaMax I\/O and control system. This module features 32 output points, organized into two isolated groups of 16 points each. It is engineered for 24 VDC positive logic applications, providing reliable switching for industrial loads. A key characteristic of this module is its integrated Electronic Short Circuit Protection (ESCP), which monitors each output point to detect and report short circuit or overcurrent conditions, enhancing system safety and diagnostic capabilities.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32 discrete output points arranged in two groups of 16.\u003c\/li\u003e\n\u003cli\u003e24 VDC positive logic (sourcing) output type.\u003c\/li\u003e\n\u003cli\u003e0.5 Amp continuous current rating per point.\u003c\/li\u003e\n\u003cli\u003eIntegrated Electronic Short Circuit Protection (ESCP) for each point.\u003c\/li\u003e\n\u003cli\u003eFault reporting for overcurrent and short circuit events.\u003c\/li\u003e\n\u003cli\u003eHot-insertion capability for efficient maintenance and system expansion.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard VersaMax carriers for DIN-rail mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePackaging Machinery: Control of AC solenoids, case sealers, and labeling heads.\u003c\/li\u003e\n\u003cli\u003eMaterial Handling: Activation of motor starters, relays, and status indicators on conveyor lines.\u003c\/li\u003e\n\u003cli\u003eHVAC and Pumping: Management of contactors for large fans, pumps, and heating elements.\u003c\/li\u003e\n\u003cli\u003eAssembly Stations: Driving indicator lamps, operator interface panels, and small clamps.\u003c\/li\u003e\n\u003cli\u003eIndustrial Tools: Control for hydraulic valves and standard industrial automation equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL742\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete, Positive Logic (Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e32 (2 groups of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e150 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 min (Group to Group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eShort circuit, overcurrent, free-wheeling diodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the carrier.\u003c\/li\u003e\n\u003cli\u003eThe module supports hot-insertion; however, verify the carrier is properly grounded before seating the module.\u003c\/li\u003e\n\u003cli\u003eMount on a standard DIN rail using the appropriate VersaMax carrier.\u003c\/li\u003e\n\u003cli\u003eEnsure the external 24 VDC power supply is capable of providing sufficient current for all active loads, particularly during short circuit events, to prevent voltage drops.\u003c\/li\u003e\n\u003cli\u003eRoute signal wiring away from high-voltage or high-EMI sources to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the field power supply is correctly connected to the DC+ and DC- terminals for each group.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200MDL742?\u003c\/h3\u003e\u003cp\u003eIt is a discrete output module in the VersaMax family featuring 32 output points arranged in two groups of 16.\u003c\/p\u003e\u003ch3\u003eWhat logic type does it use?\u003c\/h3\u003e\u003cp\u003eThe module uses positive logic, supplying current to the load, with the current returning through a common terminal.\u003c\/p\u003e\u003ch3\u003eWhat is the operating voltage?\u003c\/h3\u003e\u003cp\u003eThe module operates within a range of 18 to 30 volts DC, with a nominal operating voltage of 24 volts DC.\u003c\/p\u003e\u003ch3\u003eWhat is the power consumption of IC200MDL742?\u003c\/h3\u003e\u003cp\u003eMaximum current is 150 mA when connected to a 5V backplane.\u003c\/p\u003e\u003ch3\u003eWhat is the load capacity?\u003c\/h3\u003e\u003cp\u003eIt supports a resistive load current of 0.5 amperes per point, or 2.0 amperes for 100 milliseconds for inrush current.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50734184464636,"sku":"IC200MDL742","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_2805b35c-3f84-4000-8e3f-8c08f4302657.jpg?v=1785301568"},{"product_id":"versamax-ge-fanuc-ic200cpue05-cpu-with-ethernet-interface","title":"General Electric IC200CPUE05 VersaMax PLC CPU Controller Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200CPUE05 is a high-performance PLC CPU module designed for the VersaMax automation system. This controller provides robust logic processing capabilities, supporting complex control tasks in industrial environments. It features integrated memory for user configuration and high-speed boolean execution, making it suitable for demanding real-time control applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e64 KB of user-configurable memory, expandable up to 128 KB.\u003c\/li\u003e\n\u003cli\u003eHigh-speed boolean execution at 0.8 ms\/K.\u003c\/li\u003e\n\u003cli\u003eIntegrated Ethernet port (10 Mbps) for network communication.\u003c\/li\u003e\n\u003cli\u003eDual serial interface including one RS-232 and one RS-485 port.\u003c\/li\u003e\n\u003cli\u003eSupports up to 8 SRTP server connections for multi-device communication.\u003c\/li\u003e\n\u003cli\u003eIncludes high-precision real-time and time-of-day clock functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe IC200CPUE05 is widely used in factory automation, process control, and machine management systems. Its versatile communication options allow it to serve as a central controller in distributed I\/O architectures, providing reliable data exchange between field devices and supervisory control systems.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CPUE05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e64 KB (up to 128 KB configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoolean Execution Speed\u003c\/td\u003e\n\u003ctd\u003e0.8 ms\/K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Data Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps (Half\/Full Duplex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e1x RS-232, 1x RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSRTP Server Connections\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal Time Clock Accuracy\u003c\/td\u003e\n\u003ctd\u003e100 ppm (approx. 9 sec\/day)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime of Day Clock Accuracy\u003c\/td\u003e\n\u003ctd\u003e23 ppm (approx. 2 sec\/day at 30 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the power is disconnected from the rack before installing or removing the CPU module.\u003c\/li\u003e\n\u003cli\u003eMount the module securely onto the VersaMax I\/O rack, ensuring proper alignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for RS-232 and RS-485 connections to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the module to ensure operating temperatures remain within specified limits.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200CPUE05?\u003c\/h3\u003e\u003cp\u003eThe IC200CPUE05 acts as the central processing unit for the VersaMax PLC system, managing logic execution, data processing, and communication with peripheral devices via Ethernet and serial ports.\u003c\/p\u003e\u003ch3\u003eCan the memory of this CPU be expanded?\u003c\/h3\u003e\u003cp\u003eYes, the module supports user-configurable memory up to a maximum of 128 KB.\u003c\/p\u003e\u003ch3\u003eWhat communication protocols are supported?\u003c\/h3\u003e\u003cp\u003eThis module supports Ethernet (SRTP) and serial communication via RS-232 and RS-485 interfaces.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50745474580732,"sku":"IC200CPUE05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_9e7c4f9e-1310-4d94-a090-ac19696ea2bb.jpg?v=1785474546"},{"product_id":"versamax-ge-fanuc-ic600cb503-i-o-control-module","title":"GE Fanuc IC600CB503 Versamax I\/O Control Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC600CB503 is a precision-engineered I\/O control module within the GE Fanuc Versamax series. Designed for robust industrial automation, this module facilitates critical signal management in diverse operational environments, including manufacturing, water treatment, and specialized process control systems. By providing a reliable interface for complex automation equipment, the module ensures consistent signal integrity and efficient hardware integration. The unit features integrated status monitoring through four dedicated LED indicators, which allow maintenance personnel to perform rapid diagnostics. This immediate visual feedback is essential for minimizing system downtime and optimizing performance in continuous-duty industrial applications where signal precision is paramount.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-density hardware architecture optimized for rack space efficiency.\u003c\/li\u003e\n\u003cli\u003eIntegrated 4-LED status monitoring for real-time diagnostic feedback.\u003c\/li\u003e\n\u003cli\u003eStandardized 37-pin D-type connector for multi-channel communication.\u003c\/li\u003e\n\u003cli\u003eDesigned for environmental resilience in industrial settings.\u003c\/li\u003e\n\u003cli\u003eCompatible with Versamax rack-based automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for a wide range of industrial automation tasks, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAutomated manufacturing and assembly line control.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment process management.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose signal interfacing for PLC and DCS environments.\u003c\/li\u003e\n\u003cli\u003eLocalized signal control in complex process automation systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC600CB503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eVersamax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e37-pin D-connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e4 LED Indicators\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the rack.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that the 37-pin D-type connector is fully seated and secured to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eEnsure the installation environment meets the specified temperature and humidity ratings to prevent premature hardware failure.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-EMI sources, such as high-voltage power lines or heavy motor drives, to minimize signal interference.\u003c\/li\u003e\n\u003cli\u003eConfirm proper grounding of the Versamax rack assembly to ensure electrical safety and noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC600CB503?\u003c\/h3\u003e\u003cp\u003eThe IC600CB503 is an I\/O control module designed to manage and interface signals within a Versamax automation system, providing reliable connectivity and status monitoring for industrial processes.\u003c\/p\u003e\u003ch3\u003eHow do I diagnose issues with this module?\u003c\/h3\u003e\u003cp\u003eThe module features four integrated LED status indicators on the front panel, which provide immediate visual feedback regarding the module's operational state, assisting in rapid troubleshooting and maintenance.\u003c\/p\u003e\u003ch3\u003eWhat are the power requirements for this unit?\u003c\/h3\u003e\u003cp\u003eThe module operates on a 5 VDC power supply and draws a current of 1 A under standard load conditions.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50857550381308,"sku":"IC600CB503","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_50bbb785-7040-4619-9121-05d38a84c371.jpg?v=1785565232"},{"product_id":"general-electric-versamax-ic200alg331-eb-analog-output-module","title":"General Electric IC200ALG331-EB VersaMax 4-Channel Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200ALG331-EB is a 4-channel analog output module designed for the VersaMax PLC system. This module provides high-precision signal conversion, supporting both voltage and current output modes to interface with a wide range of industrial actuators, valves, and instrumentation. It is engineered for reliable performance in demanding automation environments, offering 16-bit digital resolution for accurate control.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e4 independent analog output channels\u003c\/li\u003e\n\u003cli\u003eSupports selectable output ranges: +\/- 10VDC and 4-20mA (1 to 20mA)\u003c\/li\u003e\n\u003cli\u003eHigh-resolution 16-bit digital-to-analog conversion\u003c\/li\u003e\n\u003cli\u003eFast update time of 7 milliseconds\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for Field Power (FLD PWR) and Module Health (OK)\u003c\/li\u003e\n\u003cli\u003eOptical isolation between field signals and logic circuitry\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG331-EB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 10VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output Range\u003c\/td\u003e\n\u003ctd\u003e1 to 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (at 25 degC)\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 30VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Input to Logic)\u003c\/td\u003e\n\u003ctd\u003e250VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Input to Ground)\u003c\/td\u003e\n\u003ctd\u003e1500VAC for 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e100mA maximum plus load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system is powered down before installing or removing the module from the I\/O rack.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for a single-slot footprint within the VersaMax rack system.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the I\/O backplane to prevent electrical noise interference.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize EMI\/RFI impact.\u003c\/li\u003e\n\u003cli\u003eVerify that the external 18-30VDC power supply is correctly connected to the field power terminals.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200ALG331-EB module?\u003c\/h3\u003e\u003cp\u003eThis module acts as an interface between the VersaMax PLC processor and external analog devices, converting digital data from the controller into precise voltage or current signals to drive field equipment.\u003c\/p\u003e\u003ch3\u003eCan this module be used for both voltage and current loops?\u003c\/h3\u003e\u003cp\u003eYes, the IC200ALG331-EB is versatile and supports both +\/- 10VDC voltage outputs and 1 to 20mA current outputs, configurable based on the specific application requirements.\u003c\/p\u003e\u003ch3\u003eWhat does the FLD PWR LED indicate?\u003c\/h3\u003e\u003cp\u003eThe FLD PWR LED indicates the status of the external 18-30VDC power supply. If this LED is off, check the external power source and wiring connections to the module.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50881944191228,"sku":"IC200ALG331-EB","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_7ae81af9-f0ea-4d4c-9e9f-5a268c887f42.jpg?v=1785585693"},{"product_id":"versamax-micro-ic200uex009-ge-fanuc-expansion-unit","title":"GE Fanuc IC200UEX009 VersaMax Micro 14-Point I\/O Expansion Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC200UEX009 is a 14-point I\/O expansion unit engineered for the VersaMax Micro PLC series. This module provides additional local I\/O capacity for micro controllers in decentralized automation applications, including material handling, water treatment, and auxiliary power systems. By integrating mixed input and output types into a single compact chassis, the IC200UEX009 helps optimize cabinet space and reduce overall hardware footprint.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProvides 14 total expansion I\/O points for VersaMax Micro systems.\u003c\/li\u003e\n\u003cli\u003eFeatures 8 AC inputs and 6 relay outputs for versatile field device control.\u003c\/li\u003e\n\u003cli\u003eIntegrated wide-range AC power supply (100 to 240 VAC) eliminates the need for external step-down transformers.\u003c\/li\u003e\n\u003cli\u003eHigh-speed expansion bus interface for seamless communication with the master CPU.\u003c\/li\u003e\n\u003cli\u003eRugged screw-type terminals designed to withstand industrial vibration and thermal cycling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis expansion unit is suitable for various industrial automation tasks, such as:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaterial handling and conveyor control systems.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater pumping station monitoring.\u003c\/li\u003e\n\u003cli\u003eAuxiliary power generation and distribution management.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose machine control requiring compact I\/O expansion.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UEX009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eVersaMax Micro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Points\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e8 AC Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e6 Relay Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eScrew Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system is powered down before connecting or disconnecting the expansion unit.\u003c\/li\u003e\n\u003cli\u003eMount the unit on a standard DIN-rail or panel as specified by the VersaMax Micro installation manual.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for I\/O signals to minimize EMI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module to ensure proper ventilation and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) handling procedures when touching internal components or terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the IC200UEX009 compatible with all VersaMax Micro CPUs?\u003c\/h3\u003e\u003cp\u003eThe IC200UEX009 is designed for the VersaMax Micro series. Please verify your specific CPU model's expansion bus compatibility in the system manual before installation.\u003c\/p\u003e\u003ch3\u003eDoes this module require an external power supply?\u003c\/h3\u003e\u003cp\u003eNo, the unit features a built-in wide-range AC power supply (100 to 240 VAC) for direct connection to utility power.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50910230839548,"sku":"IC200UEX009","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_9701fc57-4109-448a-938b-8b7c66d67f82.jpg?v=1785648798"},{"product_id":"general-electric-versamax-ic200chs002b-box-style-i-o-carrier","title":"General Electric IC200CHS002B VersaMax Box-Style I\/O Carrier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200CHS002B is a box-style I\/O carrier designed for the VersaMax PLC system. This carrier provides the necessary physical mounting and electrical interface for VersaMax I\/O modules, facilitating reliable field wiring connections in industrial automation environments. It features an integrated terminal block design, allowing for direct connection of field devices to the I\/O modules.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for VersaMax I\/O modules\u003c\/li\u003e\n\u003cli\u003eBox-style terminal configuration with 36 terminals\u003c\/li\u003e\n\u003cli\u003eSupports field voltages up to 264 VAC\u003c\/li\u003e\n\u003cli\u003eIntegrated field termination for simplified wiring\u003c\/li\u003e\n\u003cli\u003eDIN rail mountable for standard industrial enclosures\u003c\/li\u003e\n\u003cli\u003eSupports up to 2 Amps per point current rating\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS002B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBox-Style I\/O Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Voltage Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePer Point Current\u003c\/td\u003e\n\u003ctd\u003e2 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGround\/Power Segment Current\u003c\/td\u003e\n\u003ctd\u003e8 Amperes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Wire Size\u003c\/td\u003e\n\u003ctd\u003eAWG #14 to #22 (single); AWG #18 (two-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the power is disconnected from the system before installing or removing the carrier or any attached I\/O modules.\u003c\/li\u003e\n\u003cli\u003eMount the carrier on a standard DIN rail in a horizontal orientation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance for ventilation and maintenance: 2 inches (5.1 cm) at the top and bottom, and 1 inch (2.54 cm) on the sides.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges (AWG #14 to #22) to ensure secure connections and prevent overheating.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) practices when handling the module to prevent damage to internal electronics.\u003c\/li\u003e\n\u003cli\u003eEnsure all field wiring is properly routed and secured to minimize mechanical stress on the terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200CHS002B?\u003c\/h3\u003e\u003cp\u003eThe IC200CHS002B acts as a base carrier for VersaMax I\/O modules, providing the mechanical support and electrical terminal points required to connect field sensors and actuators to the PLC system.\u003c\/p\u003e\u003ch3\u003eCan this carrier be used with non-VersaMax modules?\u003c\/h3\u003e\u003cp\u003eNo, this carrier is specifically engineered for the General Electric VersaMax series and is not compatible with other PLC I\/O families.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50910484824316,"sku":"IC200CHS002B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a022f20a-919a-4c13-96bf-66577b3334f1.jpg?v=1785664685"},{"product_id":"ic200mdl241-ge-fanuc-versamax-discrete-input-module","title":"General Electric IC200MDL241 VersaMax 16-Point Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200MDL241 is a 16-point discrete input module designed for the VersaMax I\/O and control system. This module provides high-density input monitoring for 240 Volts AC applications, allowing for the integration of various field devices into a VersaMax PLC or I\/O station. It is engineered for reliability in industrial environments, featuring group isolation to protect the backplane and internal circuitry from potential field-side electrical disturbances.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete AC input channels for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eOperating voltage rating of 240 Volts AC.\u003c\/li\u003e\n\u003cli\u003eIntegrated status monitoring via 16 individually numbered LEDs and one backplane communication LED.\u003c\/li\u003e\n\u003cli\u003eGroup isolation for enhanced signal integrity and system protection.\u003c\/li\u003e\n\u003cli\u003eCompact module design suitable for standard VersaMax I\/O carriers.\u003c\/li\u003e\n\u003cli\u003eBackplane current consumption of 110 milliamps.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily used within the GE VersaMax I\/O and control system architecture. It is suitable for industrial automation tasks requiring the monitoring of AC-powered sensors, limit switches, and pushbuttons in manufacturing, power generation, and process control facilities.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIC200MDL241\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e240 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time (On)\u003c\/td\u003e\n\u003ctd\u003e1 Cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGroup Isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e16 Input LEDs, 1 Backplane LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the VersaMax I\/O carrier is properly mounted and secured before installing the module.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing the module from the carrier to prevent electrical arcing or damage to the backplane pins.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the I\/O carrier to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs where necessary to reduce noise pickup in high-EMI environments.\u003c\/li\u003e\n\u003cli\u003eHandle the module with care to avoid electrostatic discharge (ESD) damage to internal components.\u003c\/li\u003e\n\u003cli\u003eVerify that the field wiring voltage matches the module specifications (240V AC) before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200MDL241?\u003c\/h3\u003e\u003cp\u003eThe IC200MDL241 is a discrete input module that detects the presence or absence of 240V AC signals from field devices and communicates this status to the VersaMax controller.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power for the inputs?\u003c\/h3\u003e\u003cp\u003eYes, the module is designed to monitor 240V AC signals; the field power must be supplied to the corresponding terminals on the I\/O carrier to energize the inputs.\u003c\/p\u003e\u003ch3\u003eHow are the inputs grouped?\u003c\/h3\u003e\u003cp\u003eThe module features group isolation, which provides electrical separation between the input groups and the backplane, helping to prevent ground loops and protect the control system.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50915451011324,"sku":"IC200MDL241","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a96dc156-41b6-494c-a7e6-f0893397dd3c.jpg?v=1785828263"},{"product_id":"ge-fanuc-ic200chs121-i-o-interposing-base","title":"GE Fanuc IC200CHS121 VersaMax 16-Point Interposing Fuse Terminal Base","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC200CHS121 is a 16-point interposing fuse-style terminal base designed for the VersaMax I\/O system. This carrier interface serves as the critical physical connection point between field wiring and modular I\/O components, ensuring robust signal integrity in industrial environments. By incorporating integrated fusing directly into the terminal base, this unit protects sensitive I\/O circuitry from electrical surges and faults, reducing maintenance intervention and preventing system downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-point terminal base configuration for high-density I\/O applications.\u003c\/li\u003e\n\u003cli\u003eIntegrated fuse protection for each channel to safeguard I\/O modules.\u003c\/li\u003e\n\u003cli\u003eDedicated LED status indicator for each channel for rapid diagnostic monitoring.\u003c\/li\u003e\n\u003cli\u003eModular connector interface for efficient field-to-backplane connectivity.\u003c\/li\u003e\n\u003cli\u003eDesigned for standard bracket-mount installation in control cabinets.\u003c\/li\u003e\n\u003cli\u003eCompact, open-enclosure design optimized for VersaMax system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe IC200CHS121 is widely utilized in industrial automation systems requiring reliable signal distribution and circuit protection, including water treatment facilities, automotive manufacturing lines, and power generation control systems.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBracket Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 100 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Altitude\u003c\/td\u003e\n\u003ctd\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003e1 LED per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the power is disconnected from the I\/O system before installing or removing the terminal base.\u003c\/li\u003e\n\u003cli\u003eMount the base on a standard bracket, ensuring proper alignment for the modular connector interface.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring is securely terminated to the fuse-style terminals to prevent intermittent signal loss.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate spacing within the control cabinet to ensure proper ventilation and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eHandle with care to avoid damage to the backplane connector pins.\u003c\/li\u003e\n\u003cli\u003eEnsure the environment is within the specified temperature range of 0 to 60 degC to maintain operational integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes this terminal base include fuses?\u003c\/h3\u003e\u003cp\u003eThe IC200CHS121 is designed as a fuse-style terminal base; however, please verify if your specific application requires the installation of specific fuse ratings upon setup.\u003c\/p\u003e\u003ch3\u003eIs this compatible with all VersaMax I\/O modules?\u003c\/h3\u003e\u003cp\u003eThis base is designed for the VersaMax I\/O system. Please consult your specific I\/O module documentation to ensure physical and electrical compatibility with the IC200CHS121 base.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50915660169468,"sku":"IC200CHS121","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_dae43a37-5738-4131-8685-f960f75b1443.jpg?v=1785836721"},{"product_id":"versamax-ge-fanuc-ic200udd110-micro-28-plc","title":"GE Fanuc IC200UDD110 Versamax Micro 28 PLC","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC200UDD110 is a compact Micro 28 programmable logic controller within the GE Fanuc Versamax automation platform. Engineered for distributed control and standalone machine automation, this unit provides a high-density I\/O solution for applications requiring localized monitoring and process regulation. With 16 integrated DC inputs and 12 DC outputs, the controller enables efficient signal handling for sensors, actuators, and motor drives in manufacturing and utility processing. Its robust design minimizes controller footprint while maximizing availability, ensuring sustained performance in space-constrained industrial control environments.\u003c\/p\u003e\u003ch3\u003eSystem Architecture\u003c\/h3\u003e\u003cp\u003eThe controller features a dedicated 24 VDC architecture, simplifying integration with standard industrial DC sensors and actuators. The processing unit supports real-time logic execution, supplemented by two onboard analog potentiometers. These components allow operators to perform manual fine-tuning of system setpoints or timing parameters directly on the unit without necessitating a programming terminal. The internal memory is optimized for high-speed cycle execution, and the unit maintains high energy efficiency with a total power draw of 5 W, allowing for minimal heat dissipation within control enclosures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntegrated 28-point I\/O configuration: 16 DC inputs and 12 DC outputs.\u003c\/li\u003e\n\u003cli\u003eOnboard analog adjustment via two integrated potentiometers for setpoint tuning.\u003c\/li\u003e\n\u003cli\u003eCompact, high-density design suitable for space-constrained enclosures.\u003c\/li\u003e\n\u003cli\u003eLow power consumption (5 W) for efficient thermal management.\u003c\/li\u003e\n\u003cli\u003eNative compatibility with the Versamax series bus architecture.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis controller is designed for small-to-medium scale automation tasks, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eStandalone machine control and sequencing.\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O processing in larger manufacturing systems.\u003c\/li\u003e\n\u003cli\u003eMaterial handling and conveyor system regulation.\u003c\/li\u003e\n\u003cli\u003eUtility process monitoring and small-scale pump control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UDD110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersamax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O\u003c\/td\u003e\n\u003ctd\u003e28 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e16 (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e12 (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Control\u003c\/td\u003e\n\u003ctd\u003e2 Integrated Potentiometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the controller is mounted in a clean, dry, and vibration-free environment within a NEMA-rated enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the unit to facilitate airflow and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for I\/O signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC power supply is stable and properly grounded before energizing the module.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before connecting or disconnecting field wiring to prevent electrical arcing or damage to the I\/O circuitry.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD handling procedures when touching the module to prevent damage to internal electronics.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the two potentiometers on the IC200UDD110?\u003c\/h3\u003e\u003cp\u003eThe two integrated potentiometers allow for manual, real-time adjustment of system parameters such as timers, counters, or analog setpoints without the need to connect a programming terminal.\u003c\/p\u003e\u003ch3\u003eDoes this module support external memory cards?\u003c\/h3\u003e\u003cp\u003eNo, the IC200UDD110 utilizes internal, non-removable memory optimized for high-speed cycle execution.\u003c\/p\u003e\u003ch3\u003eWhat is the required input voltage for the digital I\/O?\u003c\/h3\u003e\u003cp\u003eThe digital inputs and outputs are designed for 24 VDC operation, matching the controller's internal power architecture.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50940278079740,"sku":"IC200UDD110","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_bdcc2522-1e7c-466e-975e-fe20fab3cb76.jpg?v=1786156948"},{"product_id":"versamax-ic200chs112-ge-fanuc-emerson-expansion-base","title":"GE Fanuc IC200CHS112 Versamax Expansion Base","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc Emerson IC200CHS112 is a high-density interposing relay expansion base designed for the Versamax I\/O and PLC platform. This module features 16 discrete points with replaceable relay channels, engineered to isolate sensitive control electronics from high-power field actuators. By facilitating quick field-level relay replacement without the need to disrupt existing system wiring, this unit significantly reduces mean time to repair (MTTR) and protects the backplane from electrical surges, ensuring continuous operation in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-point high-density interposing relay architecture.\u003c\/li\u003e\n\u003cli\u003eReplaceable relay channels for simplified maintenance.\u003c\/li\u003e\n\u003cli\u003eElectrical isolation between control electronics and field devices.\u003c\/li\u003e\n\u003cli\u003eSupports mixed-voltage switching profiles via external load power sources.\u003c\/li\u003e\n\u003cli\u003eFlexible wire gauge compatibility (12 to 24 AWG).\u003c\/li\u003e\n\u003cli\u003eDesigned for high-vibration industrial control cabinet environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis expansion base is widely utilized in power generation facilities, chemical processing plants, and water treatment infrastructure where reliable high-current switching and electrical isolation are required for PLC-based control systems.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eVersamax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoints\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eRelay Interposing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current per Terminal\u003c\/td\u003e\n\u003ctd\u003e8 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Coil Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5\/24\/125 VDC or 120\/240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e12 to 24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Torque\u003c\/td\u003e\n\u003ctd\u003e0.5 to 0.6 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e35% to 85% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system power is disconnected before installing or removing the expansion base.\u003c\/li\u003e\n\u003cli\u003eMount the base securely to the DIN rail or backplane according to Versamax system specifications.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring is properly stripped and secured within the terminal blocks to the specified torque of 0.5 to 0.6 Nm.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance for cooling and cable routing to minimize EMI interference from high-voltage lines.\u003c\/li\u003e\n\u003cli\u003eHandle with ESD precautions to prevent damage to internal control circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes this module include the relays?\u003c\/h3\u003e\u003cp\u003eYes, the IC200CHS112 is designed with replaceable relay channels, allowing for individual relay maintenance or replacement as needed.\u003c\/p\u003e\u003ch3\u003eCan this module switch different voltages?\u003c\/h3\u003e\u003cp\u003eYes, because the output contacts utilize an external load power source, the module supports mixed-voltage switching across its 16 points, provided the external power requirements are met.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50953195356412,"sku":"IC200CHS112","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_326b0543-e38c-45ef-87e2-2e64dfcc0c01.jpg?v=1786235918"},{"product_id":"general-electric-versamax-ic200ebi001-ethernet-slave-module","title":"General Electric IC200EBI001 VersaMax Ethernet Network Interface Unit","description":"\u003cp\u003eThe IC200EBI001 is a VersaMax Ethernet Network Interface Unit (ENIU) designed to facilitate distributed I\/O architecture within industrial control systems. This module acts as an Ethernet slave, managing communication between the host controller and local I\/O modules. It supports standard Ethernet connectivity, allowing for integration into various automation networks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eServes as a high-performance Network Interface Unit (NIU) for the VersaMax I\/O family.\u003c\/li\u003e\n\u003cli\u003eSupports 10\/100 Mbps Ethernet communication with auto-negotiation.\u003c\/li\u003e\n\u003cli\u003eConfigurable via rotary switches (X1, X10, X100) for IP address assignment or via ARP commands.\u003c\/li\u003e\n\u003cli\u003eSupports up to 1024 bytes of total I\/O data (512 bytes input \/ 512 bytes output).\u003c\/li\u003e\n\u003cli\u003eScalable architecture: Supports up to 8 modules (Release 1.0) or up to 64 modules with 7 expansion racks (Release 1.1 and later).\u003c\/li\u003e\n\u003cli\u003eIntegrated LED diagnostics for PWR, OK, FAULTS, LAN, and STAT status monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWater treatment and municipal wastewater management systems.\u003c\/li\u003e\n\u003cli\u003eOil and gas production, refining, and distribution automation.\u003c\/li\u003e\n\u003cli\u003ePower and energy management, including generator and transformer monitoring.\u003c\/li\u003e\n\u003cli\u003eIntelligent machinery manufacturing and industrial furnace control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200EBI001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45 Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps (Auto-negotiation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Media\u003c\/td\u003e\n\u003ctd\u003eEthernet Twisted Pair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Drop Length\u003c\/td\u003e\n\u003ctd\u003e100 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 64 modules (firmware dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003ePWR, OK, FAULTS, LAN, STAT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMount the unit on a 35mm x 7.5mm conductive, unpainted DIN rail to ensure proper chassis grounding.\u003c\/li\u003e\n\u003cli\u003eEnsure the side connector cover remains in place on the last carrier to protect internal pins from ESD and physical damage.\u003c\/li\u003e\n\u003cli\u003eVerify the power supply locking latch is in the \"locked\" position during operation to prevent intermittent power loss.\u003c\/li\u003e\n\u003cli\u003eMaintain recommended environmental clearances around the module to prevent overheating and ensure rated thermal performance.\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing I\/O modules to prevent electrical damage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200EBI001?\u003c\/h3\u003e\u003cp\u003eThe IC200EBI001 is an Ethernet Network Interface Unit that allows VersaMax I\/O modules to communicate over an Ethernet network, enabling distributed I\/O control.\u003c\/p\u003e\u003ch3\u003eHow is the IP address configured?\u003c\/h3\u003e\u003cp\u003eThe module features three rotary switches (X1, X10, X100) for manual IP address assignment. Alternatively, the IP address can be configured via the DOS command prompt using the arp-s command.\u003c\/p\u003e\u003ch3\u003eDoes the module support auto-configuration?\u003c\/h3\u003e\u003cp\u003eYes, the module performs an auto-configuration sequence upon power-up, identifying connected I\/O modules until an empty slot or fault is detected.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50980437098748,"sku":"IC200EBI001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_597535fd-4c7c-4b99-9097-3918106c3e57.jpg?v=1786724651"},{"product_id":"ge-fanuc-ic200mdl330-output-module","title":"General Electric IC200MDL330 VersaMax 16-Point 120 VAC Discrete Output Module","description":"\u003cp\u003eThe General Electric IC200MDL330 is a 16-point discrete output module designed for the VersaMax I\/O system. This module provides 16 isolated output channels, each rated for 120 VAC operation. It is engineered to interface directly with AC-powered field devices, offering robust performance in industrial automation and control environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 isolated discrete output channels\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 85 to 132 VAC (47 to 63 Hz)\u003c\/li\u003e\n\u003cli\u003eOutput current: 0.5 Amperes per point\u003c\/li\u003e\n\u003cli\u003eIntegrated status indicators: 16 individual point LEDs and 1 backplane OK LED\u003c\/li\u003e\n\u003cli\u003eBuilt-in protection: Includes snubber circuits (resistor\/capacitor network) and Metal Oxide Varistors (MOV) on each output\u003c\/li\u003e\n\u003cli\u003eMaximum inrush current: 5.0 Amperes per channel (20 ms duration)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePackaging Machinery: Controls AC solenoids for case sealers and labeling heads\u003c\/li\u003e\n\u003cli\u003eMaterial Handling \u0026amp; Conveyors: Activates motor starters, relays, and status towers\u003c\/li\u003e\n\u003cli\u003eHVAC \u0026amp; Industrial Pumping: Manages contactors for large fans, pumps, and heating elements\u003c\/li\u003e\n\u003cli\u003eAssembly Stations: Drives indicator lamps, push-button panels, and small AC clamps\u003c\/li\u003e\n\u003cli\u003eStandard Industrial Tools: Supports drill presses, arc welders, and hydraulic valve control systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16 Discrete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 132 VAC (47 to 63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e2.0 V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLeakage Current\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 mA at 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Draw\u003c\/td\u003e\n\u003ctd\u003e140 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eIsolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eMount the module in a clean, dry environment with adequate ventilation to prevent thermal derating.\u003c\/li\u003e\n\u003cli\u003eConnect output loads to the designated terminals; for highly inductive loads, consider additional external suppression.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the VersaMax rack to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the backplane power supply can accommodate the 140 mA current draw requirement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200MDL330?\u003c\/h3\u003e\u003cp\u003eIt is a 16-point, 120VAC rated, isolated output module, providing 0.5 Amps per point, belonging to the GE VersaMax Modular I\/O series.\u003c\/p\u003e\u003ch3\u003eDoes it have isolated channels?\u003c\/h3\u003e\u003cp\u003eYes, the IC200MDL330 features 16 output channels that are individually isolated, enhancing safety and troubleshooting.\u003c\/p\u003e\u003ch3\u003eWhat is the backplane current draw?\u003c\/h3\u003e\u003cp\u003eThe maximum backplane current draw is 140 mA.\u003c\/p\u003e\u003ch3\u003eDoes the module include output protection?\u003c\/h3\u003e\u003cp\u003eYes, it is equipped with built-in snubber and Metal Oxide Varistor (MOV) protection for each output to guard against transients.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50980943429884,"sku":"IC200MDL330","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_631ab484-eab7-4930-baf6-85d2fa97457a.jpg?v=1786733444"},{"product_id":"general-electric-versamax-ic220mdl643-discrete-input-module","title":"General Electric IC220MDL643 VersaMax Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC220MDL643 is a VersaMax discrete input module designed for high-density industrial control applications. This module provides 16 input points, organized into two isolated groups, allowing for flexible integration within a VersaMax PLC system. It is engineered to monitor 5\/12 VDC signals, providing reliable status feedback for automated processes.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete input points for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eTwo isolated input groups for enhanced noise immunity and circuit separation.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for each individual point plus a system OK LED for rapid diagnostics.\u003c\/li\u003e\n\u003cli\u003eLow backplane power consumption of 70 mA at 5 VDC.\u003c\/li\u003e\n\u003cli\u003eInput impedance of 2.4K Ohms for standard signal compatibility.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC220MDL643\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Groups\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e0-15 VDC (5\/12 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e2.4K Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e70 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicators\u003c\/td\u003e\n\u003ctd\u003e16 Point LEDs, 1 OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system power is disconnected before installing or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eMount the module onto the VersaMax I\/O carrier, ensuring proper alignment with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for input signals to minimize electromagnetic interference (EMI) in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerify that input voltage levels do not exceed the specified 15 VDC maximum to prevent module damage.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the control cabinet to ensure the module operates within its thermal design limits.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent electrostatic discharge (ESD) damage to the internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC220MDL643?\u003c\/h3\u003e\u003cp\u003eThis module is a discrete input interface for the GE VersaMax series, used to convert field-level DC signals into logic-level data for the PLC processor.\u003c\/p\u003e\u003ch3\u003eHow are the 16 inputs organized?\u003c\/h3\u003e\u003cp\u003eThe inputs are divided into two groups, which provides electrical isolation between the groups, helping to protect the PLC backplane from potential ground loops or voltage surges in the field wiring.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power for the inputs?\u003c\/h3\u003e\u003cp\u003eYes, the inputs require an external 5\/12 VDC source to provide the signal voltage, while the module itself draws its logic power from the VersaMax backplane.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50986078634236,"sku":"IC220MDL643","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_24a22673-5052-4b00-8c92-a69a137335b8.jpg?v=1786815717"},{"product_id":"ge-fanuc-cnc-ic655mdl580a-output-module","title":"GE Fanuc IC655MDL580A Versamax 16-Point Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC655MDL580A is a Versamax series relay output module manufactured by General Electric (GE Fanuc). This module provides 16 discrete output points, designed for reliable switching of field devices in industrial control applications. Each output point is equipped with an individual LED indicator to provide real-time status monitoring of the output state.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 Normally Open (N.O.) relay output points.\u003c\/li\u003e\n\u003cli\u003eIndividual LED status indicators for each output channel.\u003c\/li\u003e\n\u003cli\u003eIntegrated 20-point terminal block for secure field wiring.\u003c\/li\u003e\n\u003cli\u003eDesigned for integration within the Versamax I\/O system architecture.\u003c\/li\u003e\n\u003cli\u003eKeying positions set to A3 and B1 to ensure correct module placement.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC655MDL580A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eRelay (Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e2 Amps (Resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Supply Current\u003c\/td\u003e\n\u003ctd\u003e152 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Supply Current\u003c\/td\u003e\n\u003ctd\u003e180 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Block\u003c\/td\u003e\n\u003ctd\u003e20-Point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Positions\u003c\/td\u003e\n\u003ctd\u003eA3 and B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system power is disconnected before installing or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eVerify that the module keying (A3 and B1) matches the intended slot configuration to prevent improper insertion.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges for the 20-point terminal block to ensure secure connections and prevent overheating.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to minimize electrical noise interference in the control cabinet.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation within the enclosure to maintain operating temperatures within the manufacturer's specified limits.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent electrostatic discharge (ESD) damage to the internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat type of outputs does the IC655MDL580A provide?\u003c\/h3\u003e\u003cp\u003eThis module features 16 relay outputs, all of which are configured as Normally Open (N.O.).\u003c\/p\u003e\u003ch3\u003eWhat is the current rating for the relay outputs?\u003c\/h3\u003e\u003cp\u003eThe relay outputs are rated for 2 Amps under resistive load conditions.\u003c\/p\u003e\u003ch3\u003eHow do I monitor the status of the outputs?\u003c\/h3\u003e\u003cp\u003eThe module includes 16 individual LED indicators, with one LED assigned to each output point for immediate visual status feedback.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50986082107644,"sku":"IC655MDL580A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ecaa33ec-b56e-4b7c-ae35-65c72610fc78.jpg?v=1786816153"},{"product_id":"general-electric-versamax-ic200chs002d-box-style-i-o-carrier","title":"General Electric IC200CHS002D VersaMax Box-Style I\/O Carrier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200CHS002D is a box-style I\/O carrier designed for the VersaMax PLC series. This carrier provides the necessary physical interface and electrical connection points for mounting and wiring VersaMax I\/O modules, facilitating reliable signal distribution and power management within an industrial automation system.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntegrated terminal design for efficient field wiring.\u003c\/li\u003e\n\u003cli\u003eSupports 36 box-style terminals for high-density I\/O configurations.\u003c\/li\u003e\n\u003cli\u003eDesigned for standard DIN rail mounting in horizontal orientations.\u003c\/li\u003e\n\u003cli\u003eRated for operation up to 264 VAC with transient voltage protection up to 300 VAC.\u003c\/li\u003e\n\u003cli\u003eSupports a per-point current rating of 2 Amps and a total segment current capacity of 8 Amps.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS002D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e0-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Voltage\u003c\/td\u003e\n\u003ctd\u003e300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePer Point Current\u003c\/td\u003e\n\u003ctd\u003e2 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSegment Current Rating\u003c\/td\u003e\n\u003ctd\u003e8 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail (Horizontal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Wire Size\u003c\/td\u003e\n\u003ctd\u003eAWG 14-22 (Single), AWG 18 (Dual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the DIN rail is securely mounted and grounded before installing the carrier.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 2 inches (5.1 cm) at the top and bottom, and 1 inch (2.54 cm) on the sides to ensure adequate ventilation and access.\u003c\/li\u003e\n\u003cli\u003eVerify that power is disconnected from the system before inserting or removing any I\/O modules from the carrier.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges (AWG 14-22) and ensure terminals are tightened to specified torque to prevent loose connections and signal interference.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage power lines and sources of electromagnetic interference (EMI) to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC200CHS002D?\u003c\/h3\u003e\u003cp\u003eThe IC200CHS002D acts as a base carrier for VersaMax I\/O modules, providing the mechanical mounting surface and the electrical terminal blocks required to connect field devices to the PLC system.\u003c\/p\u003e\u003ch3\u003eCan this carrier be mounted vertically?\u003c\/h3\u003e\u003cp\u003eThe IC200CHS002D is designed for horizontal mounting. Please refer to the VersaMax system documentation for specific derating requirements if alternative orientations are necessary.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum wire size supported by the terminals?\u003c\/h3\u003e\u003cp\u003eThe terminals support single wire connections from AWG 14 to AWG 22, or dual wire connections using AWG 18 wire.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50995132399868,"sku":"IC200CHS002D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b16c2e5d-5920-4d62-a1cc-3d7bb8a7fc30.jpg?v=1787075067"},{"product_id":"ic200alg331-versamax-analog-output-module","title":"General Electric IC200ALG331-AA VersaMax 4-Channel Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200ALG331-AA is a 4-channel analog output module designed for the VersaMax PLC system. This module provides high-precision signal conversion, supporting both voltage and current output modes to interface with a wide range of industrial actuators, valves, and instrumentation. It features 16-bit digital resolution and a rapid update time of 7 milliseconds, ensuring responsive control in automated processes.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour independent analog output channels.\u003c\/li\u003e\n\u003cli\u003eSelectable output ranges: -10 to +10 VDC and 4-20 mA (1 to 20 mA).\u003c\/li\u003e\n\u003cli\u003eHigh-resolution 16-bit digital-to-analog conversion.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for Field Power (FLD PWR) and Module Health (OK).\u003c\/li\u003e\n\u003cli\u003eRobust isolation: 250 VAC continuous input-to-logic isolation and 1500 VAC for 60 seconds input-to-ground isolation.\u003c\/li\u003e\n\u003cli\u003eCompact single-slot module design for efficient rack utilization.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG331-AA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003ctd\u003e+\/- 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Output\u003c\/td\u003e\n\u003ctd\u003e1 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Time\u003c\/td\u003e\n\u003ctd\u003e7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (at 25 degC)\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e18 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA maximum (plus load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC (Input to Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system is powered down before installing or removing the module from the I\/O rack.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for single-slot mounting; ensure it is fully seated and the locking mechanism is engaged.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to protect against noise and potential surges.\u003c\/li\u003e\n\u003cli\u003eVerify that the external power supply is within the 18-30 VDC range before applying power to the field terminals.\u003c\/li\u003e\n\u003cli\u003eHandle with care to prevent electrostatic discharge (ESD) damage to the internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the difference between IC200ALG331 and IC200ALG331-AA?\u003c\/h3\u003e\u003cp\u003eThe IC200ALG331-AA is a revision of the base IC200ALG331 model. In most VersaMax applications, they are functionally interchangeable, but it is recommended to check your system's hardware configuration software to ensure the specific firmware revision is supported.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eYes, the module requires an external power supply of 18-30 VDC to drive the analog output signals.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51000323113212,"sku":"IC200ALG331","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_4c7c5392-47fc-4947-934d-e394b21b3429.jpg?v=1787246711"},{"product_id":"ic200chs003-ge-fanuc-versamax-input-output-carrier","title":"GE Fanuc IC200CHS003 Versamax I\/O Carrier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC200CHS003 is a high-density I\/O carrier specifically engineered for the Versamax automation platform. This component serves as the essential physical interface and field wiring termination point for Versamax I\/O modules, supporting up to 32 discrete I\/O points. By providing a centralized 36-pin connector architecture, the carrier simplifies complex control system wiring, reduces potential connection failures, and facilitates rapid module replacement during maintenance cycles.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports high-density configurations with up to 32 I\/O points.\u003c\/li\u003e\n\u003cli\u003eIntegrated 36-pin connector for streamlined field device integration.\u003c\/li\u003e\n\u003cli\u003eFour common power connection points for flexible circuit grouping and power distribution.\u003c\/li\u003e\n\u003cli\u003eRobust ABS housing designed for standard industrial control cabinet environments.\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting capability for efficient space utilization and secure installation.\u003c\/li\u003e\n\u003cli\u003eLow contact resistance (less than 10 milliohms) to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis carrier is widely utilized in industrial automation applications, including manufacturing process control, distributed I\/O systems, and machine automation. It is designed to interface field sensors and actuators with the Versamax PLC backplane, ensuring reliable signal transmission in demanding industrial settings.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersamax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e32 Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination\u003c\/td\u003e\n\u003ctd\u003e36-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (Per Point)\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (Power\/Ground)\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransient Protection\u003c\/td\u003e\n\u003ctd\u003e300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 milliohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the DIN rail is securely mounted and grounded according to local electrical standards before installing the carrier.\u003c\/li\u003e\n\u003cli\u003ePower down the system before inserting or removing any I\/O modules from the carrier to prevent electrical arcing or damage to the backplane pins.\u003c\/li\u003e\n\u003cli\u003eEnsure that field wiring is properly routed and strain-relieved to prevent mechanical stress on the 36-pin connector.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the unit to allow for heat dissipation and airflow within the cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify that the power supply voltage does not exceed the rated transient protection limits of 300 VAC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC200CHS003?\u003c\/strong\u003e\u003cbr\u003eThe IC200CHS003 acts as a base carrier that provides the mechanical mounting and electrical termination for Versamax I\/O modules, allowing field devices to connect to the PLC system via a 36-pin interface.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this carrier be used with other PLC series?\u003c\/strong\u003e\u003cbr\u003eNo, this carrier is specifically designed for the GE Fanuc Versamax series and is not compatible with other PLC platforms.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51000386683132,"sku":"IC200CHS003","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8a7abe56-b6cc-4129-9c07-c029829f639b.jpg?v=1787249812"},{"product_id":"ge-fanuc-versamax-ic200mdl240-discrete-input-module","title":"General Electric IC200MDL240 VersaMax 16-Point 120V AC Input Module","description":"\u003cp\u003eThe General Electric IC200MDL240 is a 16-point discrete AC input module designed for the VersaMax PLC system. This module provides reliable signal acquisition for industrial automation applications, operating at a nominal 120V AC. It features a positive logic (sourcing) configuration, where input devices are connected between the input terminal and the common terminal.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 discrete AC input points organized into two groups of eight.\u003c\/li\u003e\n\u003cli\u003eSupports a wide input voltage range of 0-132 VAC.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for point-level monitoring and backplane power verification.\u003c\/li\u003e\n\u003cli\u003eCompact, modular design suitable for DIN-rail mounting.\u003c\/li\u003e\n\u003cli\u003eHigh isolation ratings: 250 VAC continuous and 1500 VAC for 1 minute.\u003c\/li\u003e\n\u003cli\u003eCompatible with VersaMax CPU and Network Interface Units (NIU).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePackaging and bottling machinery control.\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems, including conveyors and sorters.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment process monitoring.\u003c\/li\u003e\n\u003cli\u003eDistributed I\/O nodes in energy and oil\/gas facilities.\u003c\/li\u003e\n\u003cli\u003eGeneral industrial assembly and quality control feedback.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e16 (2 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e70-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0-40 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Consumption\u003c\/td\u003e\n\u003ctd\u003e30 mA (5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 min) \/ 250 VAC (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail (Horizontal or Vertical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eInspect the module for physical damage prior to installation.\u003c\/li\u003e\n\u003cli\u003eThe module supports both horizontal and vertical DIN-rail mounting. Ensure proper ventilation in the enclosure.\u003c\/li\u003e\n\u003cli\u003eField devices must be wired between the input terminal and the group common.\u003c\/li\u003e\n\u003cli\u003eUse caution during hot insertion; ensure the backplane is stable to prevent disruption to other modules on the rack.\u003c\/li\u003e\n\u003cli\u003eVerify backplane power status via the onboard LED indicators after installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200MDL240?\u003c\/h3\u003e\u003cp\u003eIt is a 16-point, 120V AC discrete input module for the GE VersaMax series, utilizing positive logic (sourcing) to interface with field devices like limit switches and sensors.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eWhile the module draws its internal logic power from the backplane, the connected field devices require an external 120V AC source to provide the input signals.\u003c\/p\u003e\u003ch3\u003eWhat is the isolation rating of this module?\u003c\/h3\u003e\u003cp\u003eThe module provides 1500 VAC isolation for 1 minute and 250 VAC continuous isolation between user inputs and logic\/frame ground.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51000398512380,"sku":"IC200MDL240","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_dc40300c-ced5-48c4-a3a3-d5eba3dfef6f.jpg?v=1787250375"},{"product_id":"general-electric-versamax-ic200chs001a-box-style-i-o-carrier","title":"General Electric IC200CHS001A VersaMax Box-Style I\/O Carrier","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200CHS001A is a box-style I\/O carrier designed for the VersaMax PLC series. This carrier provides the necessary mounting and electrical interface for VersaMax I\/O modules, facilitating reliable signal distribution and field wiring connections in industrial automation environments. It is engineered to support up to 32 I\/O points, offering a compact solution for distributed or centralized control architectures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports up to 32 I\/O points for high-density signal management.\u003c\/li\u003e\n\u003cli\u003eEquipped with 36 box-style screw terminals for secure field wiring.\u003c\/li\u003e\n\u003cli\u003eDesigned for standard DIN-rail mounting, ensuring quick and efficient installation.\u003c\/li\u003e\n\u003cli\u003eRated for a maximum voltage of 264 VAC, accommodating a wide range of industrial control applications.\u003c\/li\u003e\n\u003cli\u003eRobust construction suitable for demanding automation environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS001A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eBox-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Count\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax I\/O Points\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Point\u003c\/td\u003e\n\u003ctd\u003e2 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Voltage Transients\u003c\/td\u003e\n\u003ctd\u003e300 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Torque\u003c\/td\u003e\n\u003ctd\u003e0.37 to 0.5 lb-ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure all power to the I\/O system is disconnected before installing or removing modules from the carrier.\u003c\/li\u003e\n\u003cli\u003eMount the carrier onto a standard 35mm DIN rail, ensuring it is securely locked in place.\u003c\/li\u003e\n\u003cli\u003eWhen wiring, ensure that terminal screws are tightened to the specified torque range (0.37 to 0.5 lb-ft) to prevent loose connections and potential signal degradation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing to minimize electromagnetic interference (EMI) from high-voltage lines or high-frequency drives.\u003c\/li\u003e\n\u003cli\u003eVerify that the total current draw of the I\/O modules does not exceed the capacity of the power supply connected to the carrier.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC200CHS001A?\u003c\/strong\u003e\u003cbr\u003eThe IC200CHS001A serves as a base carrier for GE VersaMax I\/O modules, providing both the mechanical mounting interface and the electrical terminal blocks for field wiring.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this carrier be used with all VersaMax modules?\u003c\/strong\u003e\u003cbr\u003eThis carrier is specifically designed for box-style I\/O modules within the VersaMax family. Please verify compatibility with your specific module part number before installation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the maximum current rating per point?\u003c\/strong\u003e\u003cbr\u003eThe carrier supports a maximum of 2 Amps per point.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51002026230012,"sku":"IC200CHS001A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b3b06dc6-909b-43ed-afc4-5b4ddea49cfb.jpg?v=1787332625"},{"product_id":"general-electric-versamax-ic200uex626-analog-expansion-unit","title":"General Electric IC200UEX626 VersaMax Analog Expansion Unit","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC200UEX626 is an analog expansion unit designed for the VersaMax series of programmable logic controllers. This module provides additional analog I\/O capacity to a VersaMax system, allowing for the integration of various sensors and actuators that require voltage or current signaling. It is engineered for industrial automation environments requiring precise signal conversion and control.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntegrated 6-channel analog configuration\u003c\/li\u003e\n\u003cli\u003e4 Analog Inputs supporting multiple ranges: -10 to +10 VDC, 0 to 10 VDC, 4 to 20 mA, and 0 to 20 mA\u003c\/li\u003e\n\u003cli\u003e2 Analog Outputs supporting ranges: 0 to 10 VDC, 4 to 20 mA, and 0 to 20 mA\u003c\/li\u003e\n\u003cli\u003eOperates on a 24 VDC power supply\u003c\/li\u003e\n\u003cli\u003eCompact design for efficient panel space utilization\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200UEX626\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e-10 to +10 VDC, 0 to 10 VDC, 4-20 mA, 0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC, 4-20 mA, 0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the expansion unit.\u003c\/li\u003e\n\u003cli\u003eMount the module securely to the DIN rail or backplane according to the VersaMax system architecture.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize electromagnetic interference (EMI) and noise.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to ensure signal integrity and protect against electrical surges.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC power supply is within the specified operating range before energizing the module.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the unit to prevent overheating during continuous operation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC200UEX626?\u003c\/strong\u003e\u003cbr\u003eThis is an analog expansion unit used to increase the number of analog inputs and outputs available to a General Electric VersaMax PLC system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require an external power supply?\u003c\/strong\u003e\u003cbr\u003eYes, the unit operates on a 24 VDC power supply.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat signal types are supported by the inputs?\u003c\/strong\u003e\u003cbr\u003eThe inputs support voltage ranges of -10 to +10 VDC and 0 to 10 VDC, as well as current ranges of 4 to 20 mA and 0 to 20 mA.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51002032783612,"sku":"IC200UEX626","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_95a9ffa6-f84b-40bd-876e-08208cbf2008.jpg?v=1787332799"},{"product_id":"ic200dbi001-ge-fanuc-versamax-remote-i-o-network-interface-module","title":"General Electric IC200DBI001 VersaMax DeviceNet Network Interface Unit","description":"\u003cp\u003eThe General Electric IC200DBI001 is a dedicated Remote I\/O Network Interface Unit (NIU) designed for the VersaMax distributed I\/O system. This module functions as a DeviceNet slave, enabling seamless integration of VersaMax I\/O stations into DeviceNet communication networks. It supports efficient data exchange between the host controller and the local I\/O modules, providing a scalable solution for complex automation architectures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports DeviceNet slave communication protocol.\u003c\/li\u003e\n\u003cli\u003eHandles up to 128 bytes of input and 128 bytes of output data.\u003c\/li\u003e\n\u003cli\u003eSupports up to 8 VersaMax I\/O modules per station.\u003c\/li\u003e\n\u003cli\u003eConfigurable data rates of 125 kbps, 250 kbps, and 500 kbps.\u003c\/li\u003e\n\u003cli\u003eIntegrated status indicators for Power, OK, Fault, Module, Network, and Force status.\u003c\/li\u003e\n\u003cli\u003e5-pin open-style connector for standard DeviceNet cabling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200DBI001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocol\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Modules per Station\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e128 bytes input \/ 128 bytes output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current (5V)\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current (3.3V)\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e5-pin open-style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAutomotive manufacturing and vehicle assembly lines.\u003c\/li\u003e\n\u003cli\u003eHeavy industry process optimization including steel and lime production.\u003c\/li\u003e\n\u003cli\u003ePharmaceutical production flow management.\u003c\/li\u003e\n\u003cli\u003ePrecision manufacturing and smart factory connectivity.\u003c\/li\u003e\n\u003cli\u003eMachining center control and real-time data exchange for assembly equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe module is designed for DIN-rail mounting; ensure the rail is securely grounded.\u003c\/li\u003e\n\u003cli\u003eConnect the DeviceNet cable to the 5-pin open-style connector; ensure proper polarity.\u003c\/li\u003e\n\u003cli\u003eGrounding: Connect the bare shield wire to Pin 3 of the connector.\u003c\/li\u003e\n\u003cli\u003eTermination: If the NIU is located at either end of the network trunk, install a 121-ohm, 1%, 1\/4W resistor across Pin 2 (CAN_L) and Pin 4 (CAN_H).\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before installing or removing modules to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the module to maintain operating temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the GE IC200DBI001?\u003c\/h3\u003e\u003cp\u003eThe IC200DBI001 is a DeviceNet Network Interface Unit that acts as a slave, allowing up to 8 VersaMax I\/O modules to communicate with a DeviceNet master controller.\u003c\/p\u003e\u003ch3\u003eHow much I\/O data can this unit process?\u003c\/h3\u003e\u003cp\u003eThe unit supports up to 128 bytes of input data and 128 bytes of output data, plus additional status and control words per bus scan.\u003c\/p\u003e\u003ch3\u003eWhat are the supported network speeds?\u003c\/h3\u003e\u003cp\u003eThe module supports standard DeviceNet baud rates of 125 kbps, 250 kbps, and 500 kbps, depending on the bus length.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51006378901756,"sku":"IC200DBI001","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_f4c1ab09-abf8-4cc9-966a-dbd8eb216e5d.jpg?v=1787502360"},{"product_id":"versamax-ic200chs111-ge-fanuc-interposing-i-o-main-base","title":"GE Fanuc IC200CHS111 Versamax Interposing I\/O Main Base","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC200CHS111 is a Versamax series interposing I\/O main base designed to provide robust electrical isolation between field devices and control system electronics. This module features 16 isolated channels, ensuring that high-voltage field signals do not compromise the integrity of the PLC backplane. By facilitating point-to-point galvanic isolation, the IC200CHS111 protects sensitive control hardware from voltage surges, cross-channel interference, and ground loops in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Isolation:\u003c\/strong\u003e Provides independent galvanic separation for each of the 16 I\/O points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Termination:\u003c\/strong\u003e Equipped with 50 box-style terminal blocks to support secure, vibration-resistant field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Diagnostics:\u003c\/strong\u003e Includes 16 integrated LEDs for real-time status monitoring of individual channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDedicated Power Input:\u003c\/strong\u003e Features specific terminals (A17 and A18) for 24 VDC logic power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged Design:\u003c\/strong\u003e Engineered for reliable operation in high-stress environments, including chemical processing and power generation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Isolated Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Carry Current\u003c\/td\u003e\n\u003ctd\u003e8.0 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive Load Capacity\u003c\/td\u003e\n\u003ctd\u003e8 A at 250 VAC \/ 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInductive Load Capacity\u003c\/td\u003e\n\u003ctd\u003e6 A at 250 VAC \/ 4 A at 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switching Voltage\u003c\/td\u003e\n\u003ctd\u003e380 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switching Power\u003c\/td\u003e\n\u003ctd\u003e2000 VA (AC) \/ 240 W (DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always disconnect power from the I\/O base and associated field devices before installing or removing modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the base is securely mounted to the DIN rail or backplane to maintain proper grounding and mechanical stability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cables for field connections to minimize EMI. Ensure all terminal screws are tightened to the specified torque to prevent loose connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Maintain adequate ventilation around the module to ensure operating temperatures remain within the 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling:\u003c\/strong\u003e Use appropriate electrostatic discharge (ESD) precautions when handling the module to prevent damage to internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC200CHS111?\u003c\/strong\u003e\u003cbr\u003eIt acts as an interposing base to provide galvanic isolation between field-side signals and the control system, protecting the PLC from electrical faults.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module handle AC and DC loads?\u003c\/strong\u003e\u003cbr\u003eYes, it is rated for both AC and DC switching, with specific limits for resistive and inductive loads as detailed in the technical specifications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHow do I monitor the status of the channels?\u003c\/strong\u003e\u003cbr\u003eThe module features 16 individual LEDs on the front panel that provide visual feedback for each channel's switching state.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51006457479420,"sku":"IC200CHS111","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_19b1a930-1aea-4fbe-a102-41c11a958556.jpg?v=1787509954"}],"url":"https:\/\/www.electronicplc.com\/collections\/ge-versamax.oembed?page=3","provider":"Electronic PLC","version":"1.0","type":"link"}