{"title":"Sensors","description":"\u003cp\u003eThe accuracy of an automation system is only as good as its inputs. Our sensor portfolio includes high-precision transducers for pressure, temperature, flow, and position. Whether you need inductive proximity switches for high-speed counting or sophisticated laser displacement sensors for quality control, we provide hardware that maintains calibration in the toughest conditions. These sensors offer the repeatable, drift-free performance required for closed-loop control systems where every millimeter and millibar counts.\u003c\/p\u003e","products":[{"product_id":"fc-bsn-1608-honeywell-sensor-converter-module","title":"FC-BSN-1608 Honeywell Sensor Converter Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-BSN-1608\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNAMUR sensor interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for integration into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell Safety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments. It converts signals from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNAMUR-compliant proximity sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto a format compatible with industrial safety controllers, ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-integrity, deterministic performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor safety-critical monitoring.\u003c\/p\u003e\n\u003cp\u003eWith a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact, ruggedized form factor\u003c\/strong\u003e, the module is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espace-efficient installation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein dense control cabinets and maintains stable operation under\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous-duty industrial conditions\u003c\/strong\u003e, making it ideal for hazardous area applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eFC-BSN-1608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eNAMUR Sensor Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety-Instrumented Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e14.8 cm × 7 cm × 26.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Mass\u003c\/td\u003e\n\u003ctd\u003e0.15 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Status\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade safety hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeployment and Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-BSN-1608\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis essential for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety-critical loops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing NAMUR sensors for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eposition, limit, or speed detection\u003c\/strong\u003e. It ensures that signal changes, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen-circuit or short-circuit faults\u003c\/strong\u003e, are detected reliably and transmitted accurately to the safety logic solver. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einstallation-friendly footprint\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows seamless integration into existing Honeywell architectures, minimizing downtime during upgrades or routine maintenance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module suitable for use in intrinsically safe (IS) applications?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-BSN-1608\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to interface with NAMUR-compliant sensors typically used in safety systems. Verify your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem loop diagram and intrinsic safety requirements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebefore commissioning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module provide fault diagnostics for the connected sensors?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edetection of signal anomalies\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echaracteristic of NAMUR loops, providing reliable feedback to your safety controller for preventative action.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48746719445244,"sku":"FC-BSN-1608","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FC-BSN-16081_d5e083e5-d26d-444e-a5e1-ec4232ad449e.jpg?v=1773645565"},{"product_id":"woodward-5464-414-digital-microprocessor-speed-sensor-module","title":"Woodward 5464-414 Digital Microprocessor Speed Sensor Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-414\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance digital speed sensing module developed for the Woodward MicroNet control platform. This microprocessor-based module interfaces with magnetic pickups (MPUs) or active proximity probes to deliver precise rotational speed measurements to the system CPU.\u003c\/p\u003e\n\u003cp\u003eDesigned for critical prime mover applications—including gas turbines, steam turbines, and large reciprocating engines—the 5464-414 uses advanced digital signal processing and high-resolution pulse counting to ensure accurate and stable RPM detection. Its onboard microprocessor performs independent signal validation and filtering, enhancing reliability in high-vibration and high-EMI industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe module is housed in a rugged plug-in chassis format compatible with MicroNet Simplex and Triple Modular Redundant (TMR) systems. Software-configurable speed ranges and alarm setpoints allow flexible deployment for overspeed protection, governor control, and safety-instrumented functions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e5464-414\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eMicroNet Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDigital microprocessor-based speed sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eMagnetic Pickup (MPU) or active proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003eUp to 25 kHz+ (turbine applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Method\u003c\/td\u003e\n\u003ctd\u003eOnboard microprocessor with digital filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution digital pulse counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMicroNet Simplex and TMR chassis compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.6 cm × 24.8 cm × 26.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eThe 5464-414 is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine speed monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine overspeed protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge reciprocating engine governor control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombined-cycle power plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffshore oil and gas platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Instrumented Systems (SIS) requiring redundant speed signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is especially suited for overspeed protection racks where independent, hardware-based RPM verification is required for safety compliance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5464-414 detect low-speed conditions?\u003c\/strong\u003e\u003cbr\u003eYes. The digital microprocessor design allows accurate tracking of very low frequencies during turbine startup, turning gear operation, and coast-down phases, offering a wide dynamic measurement range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 5464-414 compatible with TMR systems?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports MicroNet Triple Modular Redundant (TMR) configurations, enabling 2-out-of-3 voting logic for safety-critical speed monitoring applications.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751328508,"sku":"5464-414","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-414.jpg?v=1772521830"},{"product_id":"5464-658-woodward-digital-speed-sensor-module","title":"5464-658 Woodward Digital Speed Sensor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5464-658\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed acquisition interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. This module efficiently tracks rotating machinery velocity by converting raw pulses from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emagnetic pickups (MPUs)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eproximity probes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto precise digital data. By offloading the frequency-to-digital conversion from the main CPU, the 5464-658 ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero-lag speed sensing\u003c\/strong\u003e, even during rapid turbine acceleration or load shedding events.\u003c\/p\u003e\n\u003cp\u003eUnlike standard analog speed converters, this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses high-speed internal counters to maintain a minimum\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-bit resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross a broad frequency spectrum. Engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efail-safe operation\u003c\/strong\u003e, it continuously monitors input signal health, instantly detecting open circuits or shorted sensors to prevent overspeed conditions.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5464-658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency Spectrum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 25,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Acquisition Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit minimum (High-precision counter-based)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Sensor Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive MPUs, Active Proximity Probes, Eddy Current Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 VDC to 32 VDC (Amplitude range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA maximum at 12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA fuse per speed channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Dynamics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable filter time constants (8 ms or 16 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvent Tracking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms resolution for SOE (Sequence-of-Events) logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDetects speeds as low as 0.5 Hz (for barring\/turning gear monitoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-to-logic isolation for noise immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-658\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine control systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed governing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis safety-critical. It is commonly deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egrid synchronization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., large compressor trains) to monitor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft speed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring startup and shutdown sequences.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan this module power an active proximity probe?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-658\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan interface with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eactive sensors\u003c\/strong\u003e, provided the external power supply is shared or appropriately grounded to ensure signal integrity within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3.5–32 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewindow.\u003c\/p\u003e\n\u003ch4\u003eHow does it prevent \"ghost\" speed readings?\u003c\/h4\u003e\n\u003cp\u003eThe module uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprogrammable software filters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(8 ms\/16 ms) and a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehardware-level minimum frequency threshold\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 Hz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto filter out electrical noise and low-amplitude vibration that could otherwise be misinterpreted as rotation.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746763583740,"sku":"5464-658","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-658.jpg?v=1772175918"},{"product_id":"generator-load-sensor-woodward-8290-048","title":"Generator Load Sensor Woodward 8290-048","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8290-048\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-accuracy load sensing module developed by Woodward, Inc. for kW measurement and load-sharing applications in synchronous generator systems.\u003c\/p\u003e\n\u003cp\u003eThe module converts electrical measurements from Potential Transformers (PT) and Current Transformers (CT) into a proportional DC output signal used by speed governors to maintain balanced load distribution across multiple generators or during utility grid connection. This helps prevent engine overloading and ensures stable power quality in parallel operation systems.\u003c\/p\u003e\n\u003cp\u003eIts rugged analog design provides reliable performance in harsh industrial environments such as marine power systems, mining sites, and distributed generation plants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8290-048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eReal-power (kW) load sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95–130 VAC \/ 190–260 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePT and CT measurement inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinear DC proportional to kW load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2301, EPG, and EG load-sharing systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal chassis mounting with screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.65kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEngine-room industrial temperature range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGenerator paralleling and load sharing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine vessel power management\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMining and remote site power plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCo-generation and distributed generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it measure reactive power (kVAR)?\u003c\/strong\u003e\u003cbr\u003eNo. It only measures real power (kW). Reactive power requires AVR or dedicated kVAR control systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used on 480V systems?\u003c\/strong\u003e\u003cbr\u003eYes, but only through a Potential Transformer to step voltage down to the module input range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for diesel and gas engines?\u003c\/strong\u003e\u003cbr\u003eYes. The module measures electrical output from the alternator, making it fuel-type independent.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746772824316,"sku":"8290-048","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8290-0482.jpg?v=1772006490"},{"product_id":"abb-ntr002-a-temperature-sensor-interface-module","title":"ABB NTR002-A Temperature Sensor Interface Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNTR002-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision temperature interface module for ABB Symphony Plus and Harmony distributed control systems. It provides a high-integrity bridge for integrating industrial temperature sensors directly into the control system.\u003c\/p\u003e\n\u003cp\u003eWith specialized signal conditioning for both RTDs and thermocouples, the NTR002-A reduces signal noise, eliminates the need for external transmitters, and delivers 16-bit high-resolution thermal data for critical process monitoring.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eNTR002-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Architecture\u003c\/td\u003e\n\u003ctd\u003eDual-channel temperature interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1800°C (sensor dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Precision\u003c\/td\u003e\n\u003ctd\u003e16-bit ADC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Ambient\u003c\/td\u003e\n\u003ctd\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold Junction Compensation\u003c\/td\u003e\n\u003ctd\u003eInternal thermocouple compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 × 50 × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNTR002-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used for high-accuracy temperature monitoring in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBoiler temperature supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExhaust gas systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeat exchanger efficiency monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts dual-channel design enables redundant monitoring or differential temperature measurements in critical safety loops.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support both 2-wire and 3-wire RTDs?\u003c\/strong\u003e\u003cbr\u003eYes. The NTR002-A supports standard 2-, 3-, and 4-wire RTD configurations with lead-wire compensation to maintain accuracy over long distances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with legacy Bailey Infi 90 systems?\u003c\/strong\u003e\u003cbr\u003eGenerally yes. The module is backward compatible with many Infi 90 mounting units, though baseplate compatibility should be verified before installation.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":48746784162044,"sku":"NTR002-A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NTR002-A_5eccfe1e-3ffd-4f04-a751-8fcccfa65bf9.jpg?v=1770948453"},{"product_id":"fc-bn-1608-safety-manager-namur-sensor-converter-honeywell","title":"FC-BN-1608 Safety Manager Namur Sensor Converter Honeywell","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-BN-1608\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized Safe Namur Sensor Converter designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Manager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture. This module interfaces directly with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNAMUR\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(EN 60947-5-6) proximity sensors and switches, converting their current-coded signals into logic-level data compatible with safety controllers. It manages\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 independent input channels\u003c\/strong\u003e, providing the necessary signal conditioning and fault detection required for high-integrity monitoring in hazardous and explosive atmospheres.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFC-BN-1608\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100% Brand New and Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0—8 mA (NAMUR standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kΩ (±1% precision)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.02 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell Safety Manager \/ FSC Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Fault Diagnostics\u003c\/strong\u003e: The converter differentiates between \"open circuit,\" \"short circuit,\" and valid sensor states by monitoring specific current thresholds (0—8 mA), enabling immediate identification of field wiring failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Energy Efficiency\u003c\/strong\u003e: A maximum power dissipation of only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.6 W\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross all 16 channels prevents heat buildup in high-density safety racks, extending the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMTBF\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Mean Time Between Failures) of the control system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUltra-Lightweight Integration\u003c\/strong\u003e: At only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.02 kg\u003c\/strong\u003e, the converter minimizes mechanical load on the system backplane and facilitates rapid, tool-less replacement during scheduled maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNAMUR Compliance\u003c\/strong\u003e: Strict adherence to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNAMUR signal standards\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures seamless interoperability with a wide range of third-party proximity sensors and limit switches used in critical safety loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support line monitoring?\u003c\/strong\u003e\u003cbr\u003eYes, the FC-BN-1608 utilizes NAMUR current levels to perform continuous line monitoring, providing the Safety Manager with real-time status updates regarding the integrity of the field cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this with standard 24V DC digital switches?\u003c\/strong\u003e\u003cbr\u003eThis module specifically targets NAMUR sensors. To interface standard 24V DC switches, you should utilize a standard digital input FTA or module rather than this current-sensing converter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Honeywell original part?\u003c\/strong\u003e\u003cbr\u003eWe supply the FC-BN-1608 in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% brand new\u003c\/strong\u003e, original condition. Every unit arrives in factory-sealed packaging to ensure the highest reliability for safety-instrumented functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the 1 kΩ input resistance?\u003c\/strong\u003e\u003cbr\u003eThe precision\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1 kΩ\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eresistance ensures accurate current-to-voltage conversion within the module, maintaining the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±1% tolerance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired for SIL-rated safety signal processing.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48941596344572,"sku":"FC-BN-1608","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FC-BN-16082.jpg?v=1775546352"},{"product_id":"honeywell-cc-tsp411-experion-pks-temperature-sensor-module","title":"HONEYWELL CC-TSP411 Experion PKS Temperature Sensor Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell CC-TSP411 is a high-precision temperature sensor module within the Experion PKS architecture. It processes signals from RTDs and thermocouples, converting low-level temperature inputs into a stable 4–20 mA output for process control and monitoring. Designed for reliability in harsh and hazardous environments, this module supports a wide temperature range and is supplied as 100% Brand New Original equipment.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eCC-TSP411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eRTD, Thermocouple, Thermowell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e-200°C to 1600°C (-328°F to 2912°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eIndustrial Temperature Measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal Input Flexibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupports RTD and thermocouple inputs, enabling standardization across diverse temperature applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Environmental Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOperates reliably from -40°C to +85°C without additional climate control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWide Measurement Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSuitable for cryogenic to high-temperature industrial processes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Signal Conversion:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced circuitry ensures accurate, low-noise 4–20 mA output for precise control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CC-TSP411 support cold junction compensation?\u003c\/strong\u003e\u003cbr\u003eYes, it includes built-in cold junction compensation for accurate thermocouple measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it work with 3-wire and 4-wire RTDs?\u003c\/strong\u003e\u003cbr\u003eYes, it supports standard RTD configurations with lead-wire compensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the input isolated from the output?\u003c\/strong\u003e\u003cbr\u003eYes, it provides industrial-grade isolation between sensor input and 4–20 mA output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it detect sensor faults?\u003c\/strong\u003e\u003cbr\u003eYes, it detects open and short circuit conditions and generates alarms via the Experion system.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48949968634108,"sku":"CC-TSP411","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CC-TSP4112.jpg?v=1775720203"},{"product_id":"fc-tsgash-1624-honeywell-gas-sensor-fta-module","title":"FC-TSGASH-1624 Honeywell Gas Sensor FTA Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell FC-TSGASH-1624 is a specialized Field Termination Assembly (FTA) designed for gas detection applications within Safety Manager and Experion PKS safety architectures. It provides 16 dedicated channels for interfacing gas detection sensors, enabling reliable communication between hazardous-area field devices and the safety control system.\u003c\/p\u003e\n\u003cp\u003eThis module supports signal conditioning and secure electrical interfacing for critical fire and gas (F\u0026amp;G) monitoring systems, ensuring accurate and stable transmission of sensor data under demanding industrial conditions. We supply this unit in 100% Brand New original condition to ensure maximum reliability in life-safety applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFC-TSGASH-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Detection \/ Fire \u0026amp; Gas (F\u0026amp;G) Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Gas Sensor Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.5 × 10.8 × 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003e100% Brand New Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for Gas Detection Signals\u003c\/strong\u003e\u003cbr\u003eDesigned specifically for low-level analog signals from toxic and combustible gas detectors, ensuring accurate transmission of PPM and LEL measurements without signal degradation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Marshaling Architecture\u003c\/strong\u003e\u003cbr\u003eConsolidates 16 field channels into a structured termination interface, reducing wiring complexity and optimizing control cabinet layout in fire and gas systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Electrical Isolation\u003c\/strong\u003e\u003cbr\u003eProvides strong separation between field wiring and safety controller electronics, protecting against surges, ground faults, and industrial electrical noise.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImproved Maintenance Efficiency\u003c\/strong\u003e\u003cbr\u003eEnables safe loop testing, calibration, and field wiring maintenance without interrupting or removing core safety system modules, reducing downtime and operational risk.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eFAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this support both toxic and combustible gas sensors?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed to interface with a wide range of gas detection sensors, depending on system signal compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with older FSC systems?\u003c\/strong\u003e\u003cbr\u003eIt is primarily designed for Safety Manager architectures. Compatibility with legacy systems should be verified based on wiring and backplane configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the “Safe” design mean?\u003c\/strong\u003e\u003cbr\u003eIt indicates that the module is engineered with fault-tolerant design principles to ensure that individual channel failures do not affect the integrity of the entire system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is product authenticity ensured?\u003c\/strong\u003e\u003cbr\u003eAll units are supplied 100% brand new in original Honeywell factory-sealed packaging with full serial number traceability and OEM labeling.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48951786176764,"sku":"FC-TSGAS-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FC-TSGAS-16241.jpg?v=1775805438"},{"product_id":"fc-tsgash-1624-honeywell-gas-sensor-field-termination-assembly","title":"FC-TSGASH-1624 Honeywell Gas Sensor Field Termination Assembly","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell FC-TSGASH-1624 is a specialized Field Termination Assembly (FTA) designed for gas detection applications within Honeywell Safety Manager and Experion PKS architectures. It provides 16 dedicated channels for gas sensor interfacing, enabling safe and reliable connection between hazardous-area field devices and the safety controller. The module supports signal conditioning and robust electrical grounding to ensure accurate monitoring in Fire \u0026amp; Gas (F\u0026amp;G) systems. This unit is supplied in 100% brand new original condition to ensure maximum reliability for life-safety applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eFC-TSGASH-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Gas Sensor Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.5 cm × 10.8 cm × 8.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eGas Detection \/ Fire \u0026amp; Gas (F\u0026amp;G) Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003e100% Brand New Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch4\u003eOptimized for Gas Detection Loops\u003c\/h4\u003e\n\u003cp\u003eDesigned specifically for low-voltage, high-sensitivity gas sensor signals, ensuring accurate transmission of PPM and LEL measurements without signal degradation.\u003c\/p\u003e\n\u003ch4\u003eSimplified Marshaling Cabinet Layout\u003c\/h4\u003e\n\u003cp\u003eConsolidates 16 field wiring channels into a structured interface, reducing wiring complexity and optimizing cabinet space utilization in F\u0026amp;G systems.\u003c\/p\u003e\n\u003ch4\u003eHigh-Integrity Electrical Isolation\u003c\/h4\u003e\n\u003cp\u003eProvides strong isolation between field wiring and safety controller electronics, protecting against surges, ground faults, and industrial electrical noise.\u003c\/p\u003e\n\u003ch4\u003eEnhanced Maintenance Reliability\u003c\/h4\u003e\n\u003cp\u003eAllows field loop testing and sensor maintenance without disturbing core I\/O modules, reducing downtime and minimizing risk of accidental system trips.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eDoes it support both toxic and combustible gas sensors?\u003c\/h4\u003e\n\u003cp\u003eYes, it is compatible with a range of gas detection sensors as long as the signal levels meet Safety Manager input specifications.\u003c\/p\u003e\n\u003ch4\u003eIs it compatible with older FSC systems?\u003c\/h4\u003e\n\u003cp\u003eIt is primarily designed for Safety Manager architectures. Compatibility with FSC systems depends on backplane and cabling configuration and should be verified before migration.\u003c\/p\u003e\n\u003ch4\u003eWhat does the “Safe” architecture mean?\u003c\/h4\u003e\n\u003cp\u003eIt refers to design principles that ensure a single component failure affects only its own channel, maintaining overall system availability and safety integrity.\u003c\/p\u003e\n\u003ch4\u003eHow is product authenticity guaranteed?\u003c\/h4\u003e\n\u003cp\u003eAll units are supplied as 100% brand new original Honeywell stock, with factory-sealed packaging, original labeling, and serial number traceability to ensure full compliance with SIL3 safety standards.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48951837393148,"sku":"FC-TSGASH-1624","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FC-TSGASH-1624.jpg?v=1775805438"},{"product_id":"analytics-sensor-drive-module-honeywell-05701-a-0283","title":"Analytics Sensor Drive Module Honeywell 05701-A-0283","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 05701-A-0283 is a sensor drive module designed for industrial gas detection and monitoring systems. It powers external 4–20 mA gas sensors and processes concentration signals for toxic and flammable gas detection. We supply this module as 100% brand new and original for reliable industrial operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand \/ Manufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell \/ Analytics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e05701-A-0283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSensor Drive Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003e100% Brand New and Original\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Input Type\u003c\/td\u003e\n\u003ctd\u003e4–20 mA current loop sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0 to 25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18V to 32V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Compliance\u003c\/td\u003e\n\u003ctd\u003e40V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.25W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.165 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch4\u003eLong-Distance Signal Support\u003c\/h4\u003e\n\u003cp\u003e40V output compliance supports stable 4–20 mA transmission over long cable distances.\u003c\/p\u003e\n\u003ch4\u003eWide Measurement Range\u003c\/h4\u003e\n\u003cp\u003eSupports 0–25 mA signal monitoring for fault and over-range detection.\u003c\/p\u003e\n\u003ch4\u003eLow Power Consumption\u003c\/h4\u003e\n\u003cp\u003eEfficient 3.25W design reduces cabinet heat generation.\u003c\/p\u003e\n\u003ch4\u003eIndustrial Durability\u003c\/h4\u003e\n\u003cp\u003eOperates reliably in harsh environments from -25°C to +55°C.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eDoes the module require an external regulator?\u003c\/h4\u003e\n\u003cp\u003eNo, it operates directly from standard 18V–32V DC industrial power supplies.\u003c\/p\u003e\n\u003ch4\u003eCan it work in humid environments?\u003c\/h4\u003e\n\u003cp\u003eYes, it supports 20%–90% RH non-condensing environments.\u003c\/p\u003e\n\u003ch4\u003eWhat sensors are compatible?\u003c\/h4\u003e\n\u003cp\u003eIt supports standard industrial gas sensors using 4–20 mA current loop communication.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49094485180668,"sku":"05701-A-0283","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/05701-A-0329.jpg?v=1778745609"},{"product_id":"uv-turbine-flame-sensor-honeywell-lg1093aa04","title":"UV Turbine Flame Sensor Honeywell LG1093AA04","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell LG1093AA04 is a UV flame sensor designed for industrial gas turbine combustion monitoring. It detects ultraviolet radiation generated by hydrocarbon flames and provides continuous flame verification to the burner management system (BMS). The sensor helps prevent unsafe fuel accumulation by rapidly detecting flame-out conditions. We supply this unit as 100% brand new and original factory stock.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eLG1093AA04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eUltra-Violet (UV) Tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIndustrial Gas Turbine Flame Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Class\u003c\/td\u003e\n\u003ctd\u003eFlame Safety Products \/ Flame Scanners\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eSealed Industrial Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003ch4\u003eAccurate UV Flame Detection\u003c\/h4\u003e\n\u003cp\u003eDetects only UV radiation from active combustion to reduce false signals.\u003c\/p\u003e\n\u003ch4\u003eFast Flame Failure Response\u003c\/h4\u003e\n\u003cp\u003eProvides rapid flame-out detection for improved turbine safety.\u003c\/p\u003e\n\u003ch4\u003eRugged Industrial Design\u003c\/h4\u003e\n\u003cp\u003eHeavy-duty housing resists vibration in turbine environments.\u003c\/p\u003e\n\u003ch4\u003eEasy Installation\u003c\/h4\u003e\n\u003cp\u003eCompatible with standard turbine sight pipe mounting arrangements.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003ch4\u003eIs the Honeywell LG1093AA04 brand new?\u003c\/h4\u003e\n\u003cp\u003eYes. We provide this sensor as 100% brand new and original factory stock.\u003c\/p\u003e\n\u003ch4\u003eWhy use a UV flame sensor in gas turbines?\u003c\/h4\u003e\n\u003cp\u003eUV sensors detect active combustion while ignoring background heat radiation from hot turbine components.\u003c\/p\u003e\n\u003ch4\u003eDoes the sensor require calibration?\u003c\/h4\u003e\n\u003cp\u003eNo. The sensor begins monitoring automatically after installation and system connection.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49118089478396,"sku":"LG1093AA04","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/LG1093AA041.jpg?v=1779177651"},{"product_id":"honeywell-lg1093aa25-uv-flame-sensor","title":"Honeywell LG1093AA25 UV Flame Sensor","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell LG1093AA25 serves as a high-precision ultraviolet (UV) flame sensor specifically engineered to monitor combustion processes in demanding industrial environments. It detects ultraviolet radiation emitted by hydrocarbon flames, providing critical \"flame-on\/flame-off\" data to burner management and combustion control systems. This sensor ensures operational safety and combustion stability in gas turbines, boilers, and industrial furnaces.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eLG1093AA25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003e100% Brand New\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Technology\u003c\/td\u003e\n\u003ctd\u003eGeiger-Mueller-type phototube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Response\u003c\/td\u003e\n\u003ctd\u003e1800–2600 Å (solar blind)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Interface\u003c\/td\u003e\n\u003ctd\u003e3\/4 inch internal NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e42 ft (12.8 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°F to +350°F (-40°C to +177°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eTypically \u0026lt;200 ms (0.1s typical, 1.0s max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWindow Pressure Rating\u003c\/td\u003e\n\u003ctd\u003e150 psig at 400°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSolar Blind Technology:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemains insensitive to infrared and visible light, preventing nuisance false-positive flame detection from hot refractory or sunlight.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed Response:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTypical response time under 0.2 seconds provides near-instantaneous feedback to burner management systems, preventing fuel buildup during flame-out events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Certification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eComplies with ATEX, IECEx, and FM standards for explosive atmospheres, ensuring safe operation in volatile industrial settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Environmental Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFunctions reliably across extreme conditions, from -40°C to +177°C, suitable for direct mounting on industrial gas turbines and high-heat furnaces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a safety light curtain?\u003c\/strong\u003e\u003cbr\u003eNo, the LG1093AA25 is a UV flame sensor for combustion monitoring, not a light curtain for machine guarding.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the primary applications for this sensor?\u003c\/strong\u003e\u003cbr\u003eIt is widely used in power generation, pumping stations, and shipboard applications, particularly on General Electric (and GE licensee) gas turbines, for reliable flame monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product 100% brand new?\u003c\/strong\u003e\u003cbr\u003eYes, we supply the Honeywell LG1093AA25 as a 100% brand new, authentic original product, ready for immediate installation in your combustion control system.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49121144504572,"sku":"LG1093AA25","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/LG1093AA251.jpg?v=1779325047"},{"product_id":"catalytic-sensor-drive-module-honeywell-05701-a-0284","title":"Catalytic Sensor Drive Module Honeywell 05701-A-0284","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 05701-A-0284 is a Catalytic Sensor Drive Module designed for the Zellweger System 57 gas detection controller. This 100% brand new module delivers stable power and signal processing for catalytic gas sensors, ensuring reliable safety monitoring in industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e05701-A-0284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCatalytic Sensor Drive Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible System\u003c\/td\u003e\n\u003ctd\u003eZellweger System 57 Gas Detection Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eCatalytic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm × 100 mm × 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003cbr\u003eDirectly integrates with Zellweger System 57 controllers without additional modifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStable Sensor Performance\u003c\/strong\u003e\u003cbr\u003eProvides reliable excitation power for accurate catalytic sensor operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Durability\u003c\/strong\u003e\u003cbr\u003eOperates reliably in high-humidity and demanding industrial conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy Maintenance\u003c\/strong\u003e\u003cbr\u003eSupports fast troubleshooting and simplified sensor diagnostics.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module require sensor calibration after installation?\u003c\/strong\u003e\u003cbr\u003eYes, sensor calibration is recommended after installation for accurate gas detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module support multiple sensors?\u003c\/strong\u003e\u003cbr\u003eNo, the module is designed for a single sensor channel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cabling is recommended for noise reduction?\u003c\/strong\u003e\u003cbr\u003eShielded twisted-pair cables are recommended for improved signal stability in high-noise environments.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49123202433276,"sku":"05701-A-0284","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/05701-A-0284.jpg?v=1779414776"},{"product_id":"sensepoint-ht-flammable-sensor-honeywell-2106b2312","title":"Sensepoint HT Flammable Sensor Honeywell 2106B2312","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell 2106B2312 Sensepoint HT Flammable Sensor is an ATEX-certified gas detection sensor designed for hazardous industrial environments. This 100% brand new sensor delivers accurate flammable gas monitoring and reliable performance in high-temperature applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Number\u003c\/td\u003e\n\u003ctd\u003e2106B2312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSensepoint HT Flammable Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/4\" NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0–20% LEL or 0–100% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eT60 \u0026lt; 6 s; T90 \u0026lt; 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Alarm Level\u003c\/td\u003e\n\u003ctd\u003e5% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003emV bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-55°C to +150°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Temperature Operation\u003c\/strong\u003e\u003cbr\u003eDesigned for extreme environments up to +150°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFast Gas Detection\u003c\/strong\u003e\u003cbr\u003eProvides rapid response for improved plant safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eATEX Certified\u003c\/strong\u003e\u003cbr\u003eSuitable for hazardous and explosive industrial areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy System Integration\u003c\/strong\u003e\u003cbr\u003eStandard 3\/4\" NPT connection simplifies installation.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the sensor require calibration?\u003c\/strong\u003e\u003cbr\u003eYes, regular calibration is recommended for accurate gas detection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the sensor operate in explosive environments?\u003c\/strong\u003e\u003cbr\u003eYes, it is ATEX-certified for hazardous area applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat output signal does the sensor use?\u003c\/strong\u003e\u003cbr\u003eThe sensor provides an mV bridge output signal for system integration.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49123259252988,"sku":"2106B2312","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/2106B23121.jpg?v=1779414765"},{"product_id":"pfcd-s5520-yokogawa-sensor-controller-new-original-stock","title":"PFCD-S5520 Yokogawa Sensor Controller | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for high-density logic processing in industrial automation networks, the \u003cstrong\u003eYokogawa PFCD-S5520\u003c\/strong\u003e (\u003cstrong\u003ePFCD-S5520\u003c\/strong\u003e Sensor Controller) provides direct physical\/electrical execution for control operations. This rack-mounted hardware serves as the primary base infrastructure for field control stations, managing data throughput and module-level communication across duplexed system architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePFCD-S5520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.16 kg (18.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard rack-mount profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eDuplexed redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eSensor Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe PFCD-S5520 platform maintains deterministic control execution through its high-performance processor integration. Designed for seamless DCS integration, the rack supports multi-protocol communication, ensuring that field-level analog and digital data are processed without latency. The architecture utilizes 4-20 mA HART loop protocol compatibility and channel-to-channel isolation to prevent ground loops and electrical interference from degrading process variables. Furthermore, local cold junction compensation (CJC) is managed via the module interface, maintaining precision across temperature-sensitive input channels within the control station.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PFCD-S5520 support duplexed redundancy for CPU modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The rack is designed for duplexed operation, allowing for redundant CPU configurations to ensure high-availability control in mission-critical applications.\u003c\/p\u003e\n\u003cp\u003eQ: Is this unit compatible with existing CENTUM series communication protocols?\u003c\/p\u003e\n\u003cp\u003eA: The PFCD-S5520 supports multiple communication protocols to maintain compatibility with standard DCS network backplanes, facilitating direct data exchange within existing Yokogawa infrastructures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the rack is mounted in a standard 19-inch industrial cabinet. Verify that the rear plane is properly supported to withstand the total weight of the loaded modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted-pair cabling for all signal interfaces. Ensure shields are connected to the cabinet ground bar to prevent induced electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the PFCD-S5520 chassis to the system common ground bus using a low-impedance copper strap to facilitate effective surge protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Always disconnect the duplexed power supply before inspecting backplane connections to prevent short-circuiting the communication bus.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49177188991228,"sku":"PFCD-S5520","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/PFCD-S5520.jpg?v=1781055596"},{"product_id":"yokogawa-wu10-v-s-05-sensor-cable","title":"Yokogawa WU10-V-S-05 Sensor Cable","description":"\u003cp\u003eConfigured for high-frequency signal transmission in sensor interface networks, the \u003cstrong\u003eYokogawa WU10-V-S-05\u003c\/strong\u003e (\u003cstrong\u003eWU10-V-S-05\u003c\/strong\u003e Cable for Sensor with Variopin Connector) provides direct physical interconnection between field-mounted analytical sensors and signal processing transmitters.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWU10-V-S: Cable assembly identifier for Variopin-connected single coaxial sensor interfaces.\u003c\/li\u003e\n\u003cli\u003e05: Defined cable assembly length of 5 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eWU10-V-S-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5 meters (Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eVariopin (V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Structure\u003c\/td\u003e\n\u003ctd\u003eSingle coaxial (S)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Integrity and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe WU10-V-S-05 assembly utilizes low-capacitance coaxial geometry to maintain signal integrity for high-impedance analytical sensor inputs. The Variopin connector interface provides robust shielding against electromagnetic interference, essential for preventing signal degradation over the 5-meter run. The coaxial construction is designed to mitigate cross-talk in multi-sensor environments, ensuring that the millivolt-level process data remains stable throughout the transmission path to the transmitter terminal.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the WU10-V-S-05 cable be extended beyond the standard 5-meter length?\u003c\/p\u003e\n\u003cp\u003eA: Extending the cable length increases signal attenuation and potential noise susceptibility for high-impedance sensor inputs. If additional length is required, consult the sensor technical documentation to ensure the signal-to-noise ratio remains within the transmitter's specified operational window.\u003c\/p\u003e\n\u003cp\u003eQ: Is the Variopin connector compatible with standard BNC connections?\u003c\/p\u003e\n\u003cp\u003eA: No, the Variopin connector is a proprietary interface designed specifically for Yokogawa analytical sensors. It includes dedicated pin assignments for signal, reference, and temperature compensation that are not compatible with standard BNC or other generic RF connector interfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRoute the cable through dedicated conduit or cable trays, ensuring separation from high-voltage AC lines to prevent induced noise.\u003c\/li\u003e\n\u003cli\u003eEnsure the Variopin connector is aligned correctly with the sensor receptacle; press and rotate to lock, ensuring the sealing o-ring is seated to maintain IP-rated ingress protection.\u003c\/li\u003e\n\u003cli\u003eDo not subject the cable to sharp bends or mechanical tension; adhere to the minimum bend radius specifications to avoid damaging the internal coaxial dielectric and shield.\u003c\/li\u003e\n\u003cli\u003eClean the connector contacts with a dry, lint-free cloth if exposed to process environment moisture or contaminants before installation.\u003c\/li\u003e\n\u003cli\u003eSecure the cable with strain relief clamps at both the sensor and transmitter ends to prevent vibration-induced intermittent connectivity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49219734569212,"sku":"WU10-V-S-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/WU10-V-S-05.jpg?v=1782177848"},{"product_id":"yokogawa-fu20-05-t1-npt-wide-body-sensor","title":"Yokogawa FU20-05-T1-NPT Wide Body Sensor","description":"\u003cp\u003eConfigured for continuous analytical measurement in liquid process streams, the \u003cstrong\u003eYokogawa FU20-05-T1-NPT\u003c\/strong\u003e (\u003cstrong\u003eFU20-05-T1-NPT\u003c\/strong\u003e Wide Body Sensor) provides direct physical contact for pH and ORP potential detection within industrial pipework or bypass loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFU20: Base wide-body sensor model identifier.\u003c\/li\u003e\n\u003cli\u003e05: Defined cable length of 5 meters.\u003c\/li\u003e\n\u003cli\u003eT1: Integrated temperature sensor (Pt1000) for compensation.\u003c\/li\u003e\n\u003cli\u003eNPT: Standardized NPT process connection threading.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFU20-05-T1-NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e27 mm (Diameter) x 165 mm (Length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess Connection\u003c\/td\u003e\n\u003ctd\u003e3\/4 inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eCombined pH\/ORP and Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eElectrode Scaling and Potentiometric Performance\u003c\/h3\u003e\n\u003cp\u003eThe FU20-05-T1-NPT sensor assembly utilizes a solid-state electrolyte junction to minimize fouling and reference poisoning in high-particulate process media. The potentiometric output requires high-impedance amplification, facilitated by the integrated Pt1000 temperature element which provides real-time slope compensation. This integration suppresses measurement drift and maintains Nernstian response stability in variable-temperature streams.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the internal Pt1000 sensor compatible with non-Yokogawa transmitters?\u003c\/p\u003e\n\u003cp\u003eA: The Pt1000 element follows standard resistance-temperature characteristics (IEC 60751). It is electrically compatible with any process transmitter capable of accepting a 2-wire Pt1000 input; ensure the transmitter is correctly configured for the specific resistance range and cable impedance.\u003c\/p\u003e\n\u003cp\u003eQ: Can the NPT threads be used for submersion applications?\u003c\/p\u003e\n\u003cp\u003eA: While the NPT threads provide a secure mechanical mount for pipe installation, submersion requires additional protection for the cable entry point. Ensure the sensor is installed with a dedicated submersion assembly to prevent moisture ingress at the cable-to-sensor junction.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePerform a multi-point buffer calibration before installation to verify electrode slope and offset consistency.\u003c\/li\u003e\n\u003cli\u003eInstall the sensor in a vertical or inclined position (at least 15 degrees above the horizontal) to ensure the internal reference electrode remains in contact with the electrolyte gel.\u003c\/li\u003e\n\u003cli\u003eApply Teflon-based thread sealant to the 3\/4 inch NPT threads, ensuring the sensor is hand-tightened followed by a quarter-turn with a wrench; do not over-torque to avoid damaging the sensor body.\u003c\/li\u003e\n\u003cli\u003eRoute the 5-meter cable through flexible, liquid-tight conduit to protect it from mechanical abrasion and process chemical exposure.\u003c\/li\u003e\n\u003cli\u003eIn high-flow environments, verify that the sensor is not placed in a location subject to excessive turbulence, which could induce measurement noise and physical vibration fatigue.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49219735355644,"sku":"FU20-05-T1-NPT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FU20-05-T1-NPT2.jpg?v=1782177845"},{"product_id":"yokogawa-fp101-m31-cn0a-b-pressure-sensor","title":"Yokogawa FP101-M31-CN0A*B Pressure Sensor","description":"\u003cp\u003eConfigured for precision pressure monitoring in industrial automation systems, the \u003cstrong\u003eYokogawa FP101-M31-CN0A*B\u003c\/strong\u003e (\u003cstrong\u003eFP101-M31-CN0A*B\u003c\/strong\u003e Pressure Sensor) provides direct physical signal execution via an analog loop.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFP101\u003c\/td\u003e\n\u003ctd\u003eBase Pressure Sensor series (Silicon Micromachining)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-M31-CN0A*B\u003c\/td\u003e\n\u003ctd\u003eSpecific configuration for process connection and electrical output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFP101-M31-CN0A*B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard industrial sensor profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e0-10 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.25% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Connectivity and Integration\u003c\/h3\u003e\n\u003cp\u003eThe FP101-M31-CN0A*B utilizes silicon micromachining technology to provide stable pressure data within process control architectures. The sensor electronics are engineered to support the 4-20 mA HART loop protocol integration, ensuring that accurate process variables are transmitted with digital diagnostic capability. The internal transducer design features channel-to-channel isolation from the process environment, protecting the gauge from thermal drift and pressure spikes. Furthermore, the unit incorporates cold junction compensation mechanisms where necessary to maintain precision across the entire operating temperature range, ensuring high stability in demanding field instrumentation environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FP101-M31-CN0A*B be used in explosive atmospheres?\u003c\/p\u003e\n\u003cp\u003eA: Verification of the specific unit's certification label is required. Standard models are typically designed for general industrial use; ensure compliance with local hazardous area zoning requirements before installation.\u003c\/p\u003e\n\u003cp\u003eQ: How is the zero-point calibration maintained in this pressure sensor?\u003c\/p\u003e\n\u003cp\u003eA: The sensor employs an internal resonant silicon design that minimizes long-term drift. Periodic calibration checks should be performed using a certified pressure calibrator to verify the output against the 4-20 mA baseline.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the process connection is free of debris or contaminants before mounting the sensor to prevent clogging of the pressure port.\u003c\/li\u003e\n\u003cli\u003eUtilize appropriate thread sealant or gaskets compatible with the process fluid to ensure a leak-proof connection at the rated pressure range.\u003c\/li\u003e\n\u003cli\u003eTerminate the 4-20 mA output signal using shielded twisted-pair cabling; connect the shield to a single, common earth point to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the ambient temperature at the installation site does not exceed the -40 deg C to +85 deg C operating limit.\u003c\/li\u003e\n\u003cli\u003eSecure the unit using the designated process mounting points to prevent mechanical vibration from affecting the integrity of the pressure measurement.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49245952868604,"sku":"FP101-M31-CN0A*B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FP101-M31-CN0AB.jpg?v=1783043696"},{"product_id":"ph-orp-sensor-yokogawa-fu20-10-t1-npt","title":"pH\/ORP Sensor YOKOGAWA FU20-10-T1-NPT","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA FU20-10-T1-NPT\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eFU20\u003c\/strong\u003e pH\/ORP combination sensor, operates as a dedicated hardware component for multi-parameter electrochemical liquid analysis within industrial process pipelines.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFU20-10-T1-NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.90 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWide-body form factor (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eN\/A (Passive sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement\u003c\/td\u003e\n\u003ctd\u003epH, ORP, Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003eDouble junction (KCl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003ePt1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Type\u003c\/td\u003e\n\u003ctd\u003e3\/4 inch NPT (Tapered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe FU20-10-T1-NPT utilizes a polymerized saturated KCl reference system, which maintains signal stability in applications prone to reference electrode poisoning. This architecture facilitates integration with 4-20 mA HART loop protocol transmitters by providing distinct analog voltage signals for pH and ORP values. The internal Pt1000 temperature element allows the host transmitter to perform real-time Nernstian slope correction, ensuring measurement accuracy across variable process temperatures. The double junction design provides an effective barrier against electrolyte contamination, extending sensor longevity in harsh process fluids.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 3\/4 inch NPT connection require specific sealant for process isolation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, use an industry-standard PTFE thread tape or compatible liquid sealant suitable for the process chemistry. Ensure that only the threaded portion is exposed to the process, avoiding excessive torque that could compromise the wide-body casing.\u003c\/p\u003e\n\u003cp\u003eQ: How can the reference junction be validated for functionality?\u003c\/p\u003e\n\u003cp\u003eA: Periodic calibration against certified buffer solutions (pH 4.01, 7.00, 10.01) is required. If the slope deviates beyond the transmitter’s allowable window or the response time exceeds 30 seconds for a full-scale change, the sensor or the reference junction may require cleaning or replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the sensor orientation is within 45 degrees of vertical to maintain internal electrolyte contact with the junction.\u003c\/li\u003e\n\u003cli\u003eIf installing in-line, verify that the flow velocity is sufficient to prevent solids accumulation on the membrane, but not high enough to induce mechanical vibration or erosion.\u003c\/li\u003e\n\u003cli\u003eUtilize the integrated 3\/4 inch NPT thread for direct mounting, ensuring 5 full turns of thread engagement to guarantee pressure-tight sealing.\u003c\/li\u003e\n\u003cli\u003eConnect the cable via the variopin interface, ensuring the connector O-ring is seated correctly to prevent moisture ingress at the electrical junction.\u003c\/li\u003e\n\u003cli\u003ePerform a sensor-to-transmitter offset calibration immediately after installation to account for unique field conditions and cable impedance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49260482363644,"sku":"FU20-10-T1-NPT","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FU20-10-T1-NPT2.jpg?v=1783474799"}],"url":"https:\/\/www.electronicplc.com\/collections\/sensors.oembed?page=2","provider":"Electronic PLC","version":"1.0","type":"link"}