{"title":"Woodward","description":"\u003cp\u003e\u003cspan\u003eWoodward is the industry standard for precision energy control and optimization. This collection features specialized governors, actuators, and valves designed for power generation, marine propulsion, and industrial engine management. Known for their world-class governing algorithms and rugged mechanical design, Woodward components help plants achieve tighter fuel control and lower emissions. We supply both current-generation digital controls and legacy replacement parts to keep your turbines and engines running at peak thermal efficiency.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"9907-164-woodward-505-series-digital-governor-control-unit","title":"9907-164 Woodward 505 Series Digital Governor Control Unit","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Woodward 9907-164 (Part Number 9907-164) is a high-precision microprocessor-based control system engineered for steam turbine management. Part of the globally recognized 505 digital governor family, this unit provides specialized algorithms to regulate single-extraction or admission steam turbines. By utilizing split-stage actuators, the 9907-164 ensures stable inlet valve positioning, optimizing thermodynamic efficiency and operational safety in power generation and mechanical drive applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Identifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9907-164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e505 Digital Governor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-based PID control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUser Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel integrated 2-line LCD (24 characters per line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-programmable menu-driven software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInputs\/Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDiscrete and analog I\/O for steam valve actuation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Features and Application\u003c\/h3\u003e\n\u003cp\u003eThe 9907-164 is designed for versatility in industrial environments, capable of controlling turbogenerators and turboexpander modules. Operators can perform real-time adjustments via the integrated control panel, allowing for seamless site-specific calibration without requiring external handheld programmers. Its robust architecture handles complex steam management tasks, including the precise modulation of extraction steam for process heating while maintaining turbine speed and load stability.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eWhat is the primary difference between the 505 and 505E models?\u003c\/h4\u003e\n\u003cp\u003eThe standard 505, such as the 9907-164, focuses on speed and load control for single-valve turbines, whereas the 505E variant includes expanded logic for extraction steam turbines requiring complex pressure header control.\u003c\/p\u003e\n\u003ch4\u003eCan this unit be configured while the turbine is running?\u003c\/h4\u003e\n\u003cp\u003eWhile certain monitoring parameters are accessible, core configuration should be performed during commissioning or controlled shutdown to ensure system stability.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746716659964,"sku":"9907-164","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-164.jpg?v=1773818170"},{"product_id":"woodward-micronet-plus-5466-1000-digital-control-cpu-module","title":"Woodward MicroNet Plus 5466-1000 Digital Control CPU Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-1000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward MicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform, designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprime mover applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as hydro, gas, and steam turbines, as well as diesel and gas engines. SIL-approved, it ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh availability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault tolerance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor safety-instrumented systems.\u003c\/p\u003e\n\u003cp\u003eFeaturing a robust hardware interface with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethree RS-485 serial ports\u003c\/strong\u003e, the module supports flexible peripheral communication.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eReal-time diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ered LED fault indicator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealert technicians to I\/O lock or internal failures. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoptimized power-management circuit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eguarantees stable performance in centralized control chassis environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5466-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet Plus Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVME-based Digital Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL Approved (with safety kits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (LVD and UL Compliant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTypical Power Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Power Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3x RS-485 Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVisual Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRed Fault LED Indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-1000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex power generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive facilities\u003c\/strong\u003e, particularly in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehydroelectric plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecombined-cycle gas turbine (CCGT)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estations, where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esub-millisecond response times\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor fuel control and load sharing are essential for grid stability and equipment safety.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the fault indicator assist in troubleshooting?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ered LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eon the front faceplate illuminates during an I\/O lock, helping technicians quickly isolate communication or hardware failures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 5466-1000 hot-swappable?\u003c\/strong\u003e\u003cbr\u003eIt is recommended to disconnect all power sources before installation or removal to prevent electrical arcing and ensure proper alignment with chassis guides.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module handle multiple turbine types?\u003c\/strong\u003e\u003cbr\u003eYes, it is fully programmable and can execute control software for steam, gas, and hydro turbines, as well as industrial engine governors.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746716692732,"sku":"5466-1000","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5501-471.jpg?v=1773816255"},{"product_id":"digital-steam-turbine-governor-woodward-9907-167","title":"Digital Steam Turbine Governor Woodward 9907-167","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-167\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esecond-generation 505E digital governor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eby\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e, designed for precise\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eextraction\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadmission\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications. It enables efficient speed and load regulation, maximizing turbine efficiency while maintaining stable header pressures and electrical frequency. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-167\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ereplaces older analog or first-gen digital systems with a robust, menu-driven interface.\u003c\/p\u003e\n\u003cp\u003eThis high-reliability digital governor ensures precise control of steam valves and smooth transitions between operating modes. Built for durability in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial mechanical drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments, the module features rugged hardware capable of withstanding extreme thermal cycles.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9907-167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Steam Turbine Governor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 VDC to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 Hz to 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustable Output Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 400 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Operating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogic Solver Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed PID loops for speed and extraction control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-167\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecombined heat and power (CHP) plants\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epaper mills\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esugar refineries\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere steam turbines generate electricity and supply process steam. It is ideal for turbines requiring complex\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure-controlled extraction\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epoints for downstream industrial processes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 9907-167 support remote monitoring?\u003c\/strong\u003e\u003cbr\u003eYes, it integrates with plant-wide DCS or SCADA systems via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor real-time monitoring and remote adjustments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 505E handle over-speed conditions?\u003c\/strong\u003e\u003cbr\u003eIt includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated hardware and software trip logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat monitors speed sensors and can command valve closure if safety limits are exceeded.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module a direct replacement for older 505 versions?\u003c\/strong\u003e\u003cbr\u003eWhile the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-167\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers enhanced functionality, field wiring and software configuration settings should be verified when upgrading from legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e505 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunits.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746716725500,"sku":"9907-167","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-167.jpg?v=1773817664"},{"product_id":"cpu-module-5501-471-woodward-micronet-series","title":"CPU Module 5501-471 Woodward MicroNet Series","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-471\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward MicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems, designed for precise control of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas\/steam turbines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge engines\u003c\/strong\u003e. It ensures low-latency, deterministic execution of control algorithms, critical for prime mover applications. Built for harsh environments, the module offers robust thermal management and reliable communication via integrated Ethernet and serial ports.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5501-471\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Platform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet \/ MicroNet Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral Processing Unit (CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eArchitecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVME-based Real-Time Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 cm x 25.4 cm x 22.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.9 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEthernet, Serial Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex or Redundant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDerived from MicroNet power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eCommonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoffshore platforms\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower plants\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompressor stations\u003c\/strong\u003e, where high-frequency PID loops are crucial for fuel valve and actuator control.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5501-471 be hot-swapped?\u003c\/strong\u003e\u003cbr\u003eIt's recommended to follow shutdown or redundancy procedures to maintain system stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with older MicroNet Simplex systems?\u003c\/strong\u003e\u003cbr\u003eYes, but firmware synchronization with existing I\/O cards is necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCooling requirement?\u003c\/strong\u003e\u003cbr\u003eIt uses forced-air cooling from the Woodward chassis; maintain fan trays and clean filters for proper cooling.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746716856572,"sku":"5501-471","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5501-4712.jpg?v=1773816256"},{"product_id":"5466-258-woodward-discrete-i-o-module","title":"5466-258 Woodward Discrete I\/O Module","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-258\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density discrete I\/O module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward MicroNet and MicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol systems. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSimplex module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a critical interface for turbine and industrial engine control, monitoring field switches and commanding discrete actuators.\u003c\/p\u003e\n\u003cp\u003eIntegrated into the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet VME backplane\u003c\/strong\u003e, it delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esub-millisecond deterministic performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-speed digital state processing.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5466-258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet \/ MicroNet Plus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimplex Discrete I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e48 Discrete Inputs (24 Vdc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 Discrete Outputs (High-side switches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 mA per channel (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVMEbus compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4 × 24.6 × 26.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.86 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Logic and System Utility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-258\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehandles the strict timing requirements of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation and mechanical drive systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e48 discrete points for limit switches, pressure switches, and operator commands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutputs:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24 channels to drive relays or solenoid valves.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSimplex module\u003c\/strong\u003e, it provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecost-effective non-redundant control path\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhile maintaining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh reliability and diagnostic coverage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econsistent with the Woodward MicroNet family.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 5466-258 and a redundant TMR module?\u003c\/strong\u003e\u003cbr\u003eA: The 5466-258 is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSimplex\u003c\/strong\u003e, operating as a single I\/O path.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTMR modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euse three redundant paths with voting logic for higher fault tolerance in mission-critical safety functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 5466-258 require a separate FTM (Field Terminal Module)?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it typically connects to a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward FTM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia high-density molded cable for organized field wiring and additional circuit protection.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746716954876,"sku":"5466-258","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5466-2582.jpg?v=1773730455"},{"product_id":"woodward-8440-1750-turbine-control-panel","title":"Woodward 8440-1750 Turbine Control Panel","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-1750\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine control module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e, designed for high-reliability industrial environments. It provides precise control over\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine performance\u003c\/strong\u003e, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel regulation, speed control, and safety sequences\u003c\/strong\u003e, making it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation and mechanical drive systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat demand sub-millisecond response times for stable operation.\u003c\/p\u003e\n\u003cp\u003eBuilt for durability, the 8440-1750 integrates seamlessly into complex turbine control architectures, ensuring consistent performance in harsh operating conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8440-1750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTurbine Control Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 mm × 200 mm × 36 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePanel-mount for standard industrial enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-1750\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eheavy-duty gas and steam turbines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e. It governs turbine output, manages synchronization, and executes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eemergency shutdown sequences\u003c\/strong\u003e. Its robust design minimizes signal noise and prolongs the life of turbine governing hardware, making it ideal for demanding industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit support remote monitoring and diagnostics?\u003c\/strong\u003e\u003cbr\u003eYes. The module includes communication ports compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDCS or SCADA systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor real-time monitoring and diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this model suitable for both gas and steam turbines?\u003c\/strong\u003e\u003cbr\u003eYes, but configuration parameters must be adjusted through\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward service software\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto match the dynamic characteristics of each turbine type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 8440-1750 differ from legacy Woodward modules?\u003c\/strong\u003e\u003cbr\u003eIt offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eenhanced processing and fault tolerance\u003c\/strong\u003e, providing more precise\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel throttling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompared to older analog versions.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746729832700,"sku":"8440-1750","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8440-1750.jpg?v=1773301833"},{"product_id":"analog-output-module-5464-648-woodward","title":"Analog Output Module 5464-648 Woodward","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-648\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, precision 8-channel analog output module from Woodward, Inc., designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eturbine control platform. It provides eight fully isolated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA DC output channels\u003c\/strong\u003e, acting as the interface between digital control algorithms and field actuators such as fuel valves and positioners.\u003c\/p\u003e\n\u003cp\u003eUsing high-resolution digital-to-analog conversion (minimum 12-bit), the module delivers smooth, stable control signals essential for maintaining tight turbine speed and fuel flow tolerances.\u003c\/p\u003e\n\u003cp\u003eEngineered for harsh power generation environments, the 5464-648 supports an extended operating range from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40°C to +70°C\u003c\/strong\u003e. Each channel includes individual fault detection for open-loop and wiring diagnostics, enabling real-time monitoring by the main controller. Its compact footprint and efficient power profile make it ideal for expanding I\/O capacity in MicroNet and MicroNet Plus systems without increasing cabinet space or cooling demand.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5464-648\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMicroNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output, 8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 isolated outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% FS (at 25°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Resistance\u003c\/td\u003e\n\u003ctd\u003e600 Ω per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms (CPU synchronized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V DC (Channel-to-Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 × 160 × 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 5464-648 is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine governor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine control racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFuel valve and actuator positioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVariable Inlet Guide Vane (VIGV) control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater injection and auxiliary flow regulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts wide temperature tolerance and channel-level isolation make it suitable for both control room installations and outdoor-mounted enclosures in power plants and heavy industrial sites.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the 5464-648 support 0–20 mA or voltage outputs?\u003c\/strong\u003e\u003cbr\u003eNo. This model is hardware-optimized for 4–20 mA current loops. Voltage output requires a different module variant or an external signal converter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is it compatible with MicroNet Plus (TMR) systems?\u003c\/strong\u003e\u003cbr\u003eYes. The module can be used in various MicroNet and MicroNet Plus chassis configurations, provided the application software is configured for 8-channel analog output.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What happens during a Loss of Communication event?\u003c\/strong\u003e\u003cbr\u003eThrough GAP configuration, the module can either hold the last valid output value or transition to a predefined safe state (e.g., 0 mA or 4 mA) if CPU communication is lost.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746747265276,"sku":"5464-648","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5466-2532.jpg?v=1772610734"},{"product_id":"woodward-5466-253-micronet-tmr-high-density-analog-combo-i-o-module","title":"Woodward 5466-253 MicroNet TMR High-Density Analog Combo I\/O Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-253\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a High-Density (HD) Analog Combo Module from Woodward, Inc., designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet TMR (Triple Modular Redundant)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platform. It is engineered for mission-critical\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine and industrial engine control\u003c\/strong\u003e, consolidating multiple analog I\/O and actuator control functions into a single module.\u003c\/p\u003e\n\u003cp\u003eThis “Combo” architecture allows simultaneous handling of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed sensing, process variable acquisition, and proportional valve actuation\u003c\/strong\u003e, making it ideal for high-performance governor systems. The module supports both standard 4–20 mA signaling and direct actuator drive outputs.\u003c\/p\u003e\n\u003cp\u003eA key feature is the integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esoftware-configurable 25 Hz dither signal\u003c\/strong\u003e, which reduces mechanical stiction in hydraulic or linear actuators, ensuring smooth and precise valve positioning. With a fast\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 ms system-wide update rate\u003c\/strong\u003e, high common-mode rejection, and robust electrical isolation, the 5466-253 delivers deterministic control performance in oil \u0026amp; gas and power generation applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5466-253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eMicroNet TMR \/ 505E Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Inputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (MPU or proximity probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e8 channels (4–20 mA or 0–5 V DC, software selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (4–20 mA, max 600 Ω load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Drivers\u003c\/td\u003e\n\u003ctd\u003e2 configurable outputs (4–20 mA or 20–160 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e5 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e200 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e200 Ω (internal resistors for current inputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 V DC (Power to I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.84 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 5466-253 is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine governor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge turbogenerators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtraction\/Admission steam control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety-critical overspeed protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is particularly effective in applications where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emultiple control valves must operate in synchronized response\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto speed, load, and pressure changes. The TMR architecture ensures continued operation even if one channel experiences a fault, making it suitable for high-availability turbine installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the 5466-253 compatible with MicroNet Plus systems?\u003c\/strong\u003e\u003cbr\u003eYes. It is often designated as a preferred module for MicroNet platforms when using Coder version 5.03 or later.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Are external resistors required for 4–20 mA inputs?\u003c\/strong\u003e\u003cbr\u003eNo. The module includes onboard 200 Ω precision resistors for current loop measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Why is the 5 ms update time important?\u003c\/strong\u003e\u003cbr\u003eThe fast update rate enables near-instantaneous turbine response to load or speed changes, supporting grid frequency stability and preventing overspeed conditions.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746747527420,"sku":"5466-253","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5466-2532.jpg?v=1772610734"},{"product_id":"9905-969-woodward-analog-input-module","title":"9905-969 Woodward Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-969\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rugged\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLinkNet 6-Channel Analog Input Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by Woodward, Inc. for high-accuracy data acquisition in turbine and engine control systems. It functions as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed I\/O node\u003c\/strong\u003e, converting field analog signals (temperature, pressure, flow) into digital data transmitted over the LinkNet network to the main controller.\u003c\/p\u003e\n\u003cp\u003eBy digitizing signals close to the source, the 9905-969 reduces field wiring complexity, improves noise immunity, and enhances overall signal integrity. It is widely deployed in gas and steam turbine control panels where reliable analog monitoring is essential.\u003c\/p\u003e\n\u003cp\u003eThe module includes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-line × 24-character LCD display\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e30-key multifunction keypad\u003c\/strong\u003e, enabling local diagnostics, monitoring, and address configuration without external tools. High dielectric isolation (up to 500 VDC between power and I\/O) prevents field faults from propagating to the control network, ensuring system stability in harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eDesigned for extreme conditions, the 9905-969 supports wide temperature and humidity ranges, making it suitable for power generation, marine propulsion, and heavy industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9905-969\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Channels\u003c\/td\u003e\n\u003ctd\u003e6 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eLinkNet Distributed I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e18–32 V DC (Nominal 24 V DC @ 1 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Interface\u003c\/td\u003e\n\u003ctd\u003e2-line × 24-character LCD + 30-key keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% full scale at 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (I\/O to Network)\u003c\/td\u003e\n\u003ctd\u003e277 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Power to I\/O)\u003c\/td\u003e\n\u003ctd\u003e500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14\" W × 11\" H × 4\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 9905-969 is commonly used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine monitoring panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine propulsion control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial engine management systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical field inputs include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4–20 mA transmitters\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e0–5 V DC analog sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermocouples (via appropriate signal conditioning)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure and flow transducers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts local display allows maintenance personnel to quickly verify sensor status and system diagnostics directly at the panel.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the module support 4–20 mA inputs?\u003c\/strong\u003e\u003cbr\u003eYes. The six analog channels are configurable for standard industrial signal ranges such as 4–20 mA and 0–5 V DC (configuration via Woodward control software).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eIt is recommended to isolate or power down the 24 V DC supply before removal to avoid communication disturbances on the LinkNet bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can the keypad perform calibration?\u003c\/strong\u003e\u003cbr\u003eThe keypad is primarily used for monitoring, addressing, and diagnostics. Calibration is typically performed through the master controller engineering workstation (e.g., GAP or MicroNet systems).\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746747592956,"sku":"9905-969","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9905-969_1.jpg?v=1772610735"},{"product_id":"9905-970-woodward-linknet-distributed-i-o-module","title":"9905-970 Woodward LinkNet Distributed I\/O Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-970\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed I\/O interface node\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward LinkNet automation ecosystem\u003c\/strong\u003e. It is designed to provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed data acquisition and control signal distribution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor turbine and engine governing systems.\u003c\/p\u003e\n\u003cp\u003eThe module functions as a localized control node that connects field sensors and actuators to a central controller via a proprietary serial communication network. By decentralizing I\/O processing, the 9905-970 reduces cable runs, improves signal reliability, and supports deterministic control performance in mission-critical industrial applications.\u003c\/p\u003e\n\u003cp\u003eBuilt with ruggedized industrial components, the module is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation, offshore energy, and heavy mechanical drive systems\u003c\/strong\u003e, where environmental stress and vibration resistance are critical design requirements.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eLinkNet I\/O Platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Model\u003c\/td\u003e\n\u003ctd\u003e9905-970\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eProprietary LinkNet Serial Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e29 cm × 18.7 cm × 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or LinkNet carrier panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eNetwork \u0026amp; module health LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Architecture\u003c\/td\u003e\n\u003ctd\u003eDistributed node I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation for surge protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Design\u003c\/td\u003e\n\u003ctd\u003eHigh-vibration industrial environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe 9905-970 is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine governing architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical drive power plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffshore oil and gas installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is typically installed in local junction enclosures near the prime mover to collect field signals such as:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eValve position feedback\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature monitoring signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure and process status inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese signals are aggregated and transmitted to central controllers such as MicroNet-based control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the benefit of LinkNet architecture?\u003c\/strong\u003e\u003cbr\u003eThe LinkNet network allows multiple distributed I\/O nodes to be connected using a single twisted-pair cable in a daisy-chain topology, significantly simplifying installation complexity and reducing wiring costs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 9905-970 operate in redundant control systems?\u003c\/strong\u003e\u003cbr\u003eYes. The module is commonly deployed in redundant configurations to improve system availability and prevent single-point failures from causing turbine shutdowns.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746747953404,"sku":"9905-970","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9905-9701.jpg?v=1772521831"},{"product_id":"woodward-9905-971-discrete-input-module","title":"Woodward 9905-971 Discrete Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-971\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability distributed I\/O module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward Inc.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLinkNet Distributed Control Architecture\u003c\/strong\u003e. This module provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 discrete digital input channels\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor monitoring field device status in industrial automation systems.\u003c\/p\u003e\n\u003cp\u003eDesigned for mission-critical environments such as turbine control and power generation, the 9905-971 enables decentralized signal acquisition by moving field wiring closer to process equipment. The module communicates with the main controller via a proprietary high-speed serial LinkNet bus, significantly reducing installation complexity and improving system scalability.\u003c\/p\u003e\n\u003cp\u003eThe module also includes advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elatent fault detection\u003c\/strong\u003e, allowing continuous internal self-diagnostics to detect hidden electrical or logic failures before they impact control performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eLinkNet Distributed I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Model\u003c\/td\u003e\n\u003ctd\u003e9905-971\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 Discrete Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eLinkNet Proprietary Serial Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation for network protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Features\u003c\/td\u003e\n\u003ctd\u003eLatent fault detection + internal health monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or panel mount carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eRuggedized industrial-grade enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication Scenarios\u003c\/h2\u003e\n\u003cp\u003eThe 9905-971 is commonly used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and steam turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDistributed process automation networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy system modernization projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is especially useful in facilities requiring plant-wide digital signal monitoring without rewiring centralized control cabinets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHow does latent fault detection improve reliability?\u003c\/strong\u003e\u003cbr\u003eThe module performs internal self-tests to ensure input detection circuits are functioning correctly, helping prevent dangerous fail-to-detect failures in safety-critical systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes, but maintenance should follow\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLinkNet carrier and power supply service procedures to avoid serial bus communication interruptions during replacement.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746748084476,"sku":"9905-971","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9905-9712.jpg?v=1772521831"},{"product_id":"5453-754-woodward-micronet-ethernet-interface-module","title":"5453-754 Woodward MicroNet Ethernet Interface Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-754\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed industrial networking interface developed by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward Inc.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward MicroNet Control System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitectures. This Ethernet Network Interface (ENI) module enables secure and deterministic communication between turbine control processors and external supervisory systems such as SCADA, HMI, and DCS platforms.\u003c\/p\u003e\n\u003cp\u003eBy offloading network processing tasks from the main controller CPU, the 5453-754 improves overall system performance and supports high-volume data exchange for remote monitoring, diagnostics, and distributed control synchronization in power generation environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Model\u003c\/td\u003e\n\u003ctd\u003e5453-754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eEthernet Network Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Speed\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Auto-negotiation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interfaces\u003c\/td\u003e\n\u003ctd\u003eDual RJ45 or Fiber Optic (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP, Ethernet\/IP, UDP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Compatibility\u003c\/td\u003e\n\u003ctd\u003eVME-based MicroNet racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eBackplane-powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eLink, Activity, Speed, Status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation for EMI protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eGAP Programming Environment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 5453-754 is commonly used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and steam turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower plant distributed control networking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote turbine diagnostics and condition monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-rack synchronized control architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is especially important in modernizing legacy turbine control systems by enabling secure plant-wide data connectivity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 5453-754 support redundant networking?\u003c\/strong\u003e\u003cbr\u003eYes. When deployed in redundant CPU configurations within MicroNet Plus systems, the module can be configured for fault-tolerant network communication to maintain continuous connectivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan firmware be updated remotely?\u003c\/strong\u003e\u003cbr\u003eYes. Firmware and configuration updates are typically performed using Woodward service and engineering tools via the Ethernet interface.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746750443772,"sku":"5453-754","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5453-754.jpg?v=1772521831"},{"product_id":"woodward-8440-1831-easygen-remote-operator-interface-panel","title":"Woodward 8440-1831 easYgen Remote Operator Interface Panel","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-1831\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a remote operator interface terminal developed by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward easYgen-3000 Series\u003c\/strong\u003e. This industrial HMI terminal provides remote access to generator controller functions, allowing operators to monitor engine and electrical parameters, acknowledge alarms, and perform basic control actions without direct access to switchgear-mounted controllers.\u003c\/p\u003e\n\u003cp\u003eThe device communicates with the main controller via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCANbus\u003c\/strong\u003e, enabling real-time data synchronization between the operator terminal and the genset control system. Designed for power generation and heavy industrial environments, the 8440-1831 features a rugged front panel, high-contrast display, and membrane keypad for reliable operation under harsh lighting and vibration conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eeasYgen Accessories\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8440-1831\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eRemote Operator Interface (HMI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eCANbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e8 – 40 VDC (12\/24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eBacklit graphical LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eTactile membrane keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Connection\u003c\/td\u003e\n\u003ctd\u003ePlug-in terminal blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Compatibility\u003c\/td\u003e\n\u003ctd\u003eeasYgen-3100 \/ 3200 \/ 3400 \/ 3500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 8440-1831 is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency standby power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombined heat and power (CHP) plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine and offshore drilling power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData center backup generator installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is commonly installed in control cabinets with through-door mounting to allow safe operator interaction without exposing personnel to high-voltage equipment.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8440-1831 be used to configure the main controller?\u003c\/strong\u003e\u003cbr\u003eYes. The interface provides a mirrored control menu structure, allowing authorized users to adjust controller parameters and perform system configuration tasks directly from the HMI panel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the maximum CANbus communication distance?\u003c\/strong\u003e\u003cbr\u003eTypically up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e250 meters\u003c\/strong\u003e, depending on baud rate, cable shielding quality, and proper termination resistor placement.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746750542076,"sku":"8440-1831","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8440-1831.jpg?v=1772521831"},{"product_id":"8405-009-woodward-proact-75-electric-actuator-module","title":"8405-009 Woodward ProAct 75 Electric Actuator Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8405-009\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance actuator processor module developed by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProAct 75 Electric Actuator Series\u003c\/strong\u003e. This module functions as the intelligent control core of electric actuator systems, translating digital control signals into precise mechanical positioning for fuel racks, butterfly valves, and other flow control mechanisms used in turbines and industrial engines.\u003c\/p\u003e\n\u003cp\u003eBy processing speed and load control signals in real time, the 8405-009 enables high-accuracy combustion optimization and stable mechanical drive response. It is commonly deployed in modernized turbine and engine control systems where electric actuation replaces hydraulic control mechanisms.\u003c\/p\u003e\n\u003cp\u003eDesigned for industrial durability, the module supports fast load transient response and maintains stable operation across a wide range of electrical and environmental conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eProAct Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuator Model\u003c\/td\u003e\n\u003ctd\u003eProAct 75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Model\u003c\/td\u003e\n\u003ctd\u003e8405-009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Category\u003c\/td\u003e\n\u003ctd\u003eElectric actuator control processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque Control\u003c\/td\u003e\n\u003ctd\u003eHigh-force actuator drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Speed\u003c\/td\u003e\n\u003ctd\u003eMillisecond-level control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eRuggedized industrial enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Compatibility\u003c\/td\u003e\n\u003ctd\u003eWoodward governor and PLC control interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Protection\u003c\/td\u003e\n\u003ctd\u003eIntegrated electronic temperature monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 8405-009 is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine fuel control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge diesel engine governing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine propulsion engines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePipeline compressor stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRemote offshore power installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is especially advantageous in environments where oil-free actuation is preferred, helping reduce maintenance complexity and environmental risk.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the main advantage of the ProAct 75 electric actuator system?\u003c\/strong\u003e\u003cbr\u003eThe ProAct 75 series eliminates hydraulic oil systems, reducing maintenance requirements, improving cold-start reliability, and minimizing leak risks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8405-009 support position feedback control?\u003c\/strong\u003e\u003cbr\u003eYes. The module operates in a closed-loop control architecture, continuously monitoring actuator shaft position to ensure accurate response to governor command signals.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746750607612,"sku":"8405-009","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8405-0092.jpg?v=1772521831"},{"product_id":"woodward-9907-014-low-voltage-speed-control-module","title":"Woodward 9907-014 Low Voltage Speed Control Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-014\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized electronic speed governor from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2301A Speed Control Series\u003c\/strong\u003e. It is engineered for precise engine and turbine speed regulation in diesel engines, gas engines, and steam turbine applications.\u003c\/p\u003e\n\u003cp\u003eThis module functions as a dedicated speed control system, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eisochronous speed regulation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor constant RPM operation or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edroop control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor systems where load sharing is handled by external power management equipment.\u003c\/p\u003e\n\u003cp\u003eDesigned for harsh industrial and mobile environments, the 9907-014 features a rugged metal enclosure and supports wide temperature operation, making it suitable for marine engines, generator sets, and mechanical drive systems operating under continuous duty conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e2301A Speed Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e9907-014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e20 – 40 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e≤ 15 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Modes\u003c\/td\u003e\n\u003ctd\u003eIsochronous \/ Droop Speed Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003eMagnetic Pickup (MPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Construction\u003c\/td\u003e\n\u003ctd\u003eSheet metal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.625\" × 7.25\" × 2.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.13 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 9907-014 is commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eStandalone generator speed control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump and compressor drive systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine auxiliary propulsion engines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSmall to medium power generation sets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is best suited for applications requiring reliable constant-speed regulation without integrated load-sharing logic.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 9907-014 perform automatic load sharing?\u003c\/strong\u003e\u003cbr\u003eNo. This model is strictly a speed control governor. Load sharing must be handled by external modules such as advanced 2301A variants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the advantage of the metal chassis?\u003c\/strong\u003e\u003cbr\u003eThe sheet metal housing provides enhanced protection against electromagnetic interference (EMI), vibration stress, and mechanical shock, helping maintain stable control performance in engine room environments.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746750836988,"sku":"9907-014","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-014.jpg?v=1772521831"},{"product_id":"woodward-9905-387-proact-digital-actuator-driver-module","title":"Woodward 9905-387 ProAct Digital Actuator Driver Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-387\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision digital driver module within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProAct control family. It is engineered for advanced speed governing, load sharing, and actuator positioning control in industrial engine and turbine applications.\u003c\/p\u003e\n\u003cp\u003eThis module functions as the interface between electronic control logic and the ProAct actuator, converting low-level control signals into precise mechanical positioning commands for fuel management systems. The 9905-387 supports droop load sharing and synchronized power control, making it suitable for modern distributed generation and propulsion systems.\u003c\/p\u003e\n\u003cp\u003eBuilt for high reliability, the module includes onboard diagnostic data logging to help maintenance engineers analyze transient events, fault conditions, and system performance trends.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e9905-387\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital ProAct Driver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18 – 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003ePanel or cabinet mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 9905-387 is widely deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and diesel engine power generation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine propulsion control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMicrogrid power synchronization stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency standby generator controls\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial mechanical drive governing systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is commonly used in applications requiring fast load response and stable grid synchronization.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 9905-387 be used with non-Woodward actuators?\u003c\/strong\u003e\u003cbr\u003eThe module is specifically tuned for ProAct actuator electrical and mechanical characteristics. Using non-compatible actuators may result in unstable control performance or equipment damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the fault logging feature help maintenance?\u003c\/strong\u003e\u003cbr\u003eThe module stores internal fault and event data, helping technicians identify whether system trips were caused by signal loss, voltage instability, or internal hardware errors without requiring external monitoring tools.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746750869756,"sku":"9905-387","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9905-387.jpg?v=1772521831"},{"product_id":"8273-140-woodward-electronic-speed-control-module","title":"8273-140 Woodward Electronic Speed Control Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8273-140\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision speed control and monitoring module developed by\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward\u003c\/strong\u003e, designed for governing and protecting industrial prime movers such as turbines and engines. This module functions as a high-resolution interface between speed sensing devices and fuel control systems, enabling stable speed regulation under fluctuating mechanical loads.\u003c\/p\u003e\n\u003cp\u003eThe 8273-140 provides rapid frequency detection and responsive control adjustments to help prevent overspeed events and reduce mechanical stress on rotating equipment. Its ruggedized design ensures reliable operation in high-temperature and electrically noisy industrial environments commonly found in power generation and heavy drive applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e8273-140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eElectronic Speed Sensing and Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eMagnetic Pickup (MPU) or Proximity Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Architecture\u003c\/td\u003e\n\u003ctd\u003eAnalog \/ Digital Hybrid Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable Parameters\u003c\/td\u003e\n\u003ctd\u003eGain, Stability, Rated Speed Trim\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eSurface mount or DIN rail (adapter dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm × 12.4 cm × 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 8273-140 is commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDiesel and gas engine governor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine auxiliary control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGenerator set isochronous speed control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eParallel bus droop control operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLegacy system modernization and PLC integration projects\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is widely used where precise speed stability and fast response to load variations are required.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat sensors are compatible with the 8273-140?\u003c\/strong\u003e\u003cbr\u003eThe module is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etwo-wire magnetic pickup sensors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat generate frequency signals proportional to shaft rotational speed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module provide overspeed protection?\u003c\/strong\u003e\u003cbr\u003eYes. While primarily a governor control module, it can be configured to generate protective output signals or drive fuel actuators to minimum fuel position when overspeed thresholds are exceeded.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746750968060,"sku":"8273-140","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8273-1402.jpg?v=1772521831"},{"product_id":"9905-860-woodward-digital-steam-turbine-control","title":"9905-860 Woodward Digital Steam Turbine Control","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-860\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized digital turbine governor from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward Peak150 Series\u003c\/strong\u003e, designed for precise control of single-valve or split-range steam turbine systems. This microprocessor-based controller replaces legacy mechanical governors with modern digital PID-based regulation for speed and load management.\u003c\/p\u003e\n\u003cp\u003eThe 9905-860 processes high-speed magnetic pickup signals and executes real-time control algorithms to maintain stable turbine RPM under varying mechanical load conditions. It also integrates overspeed protection and diagnostic monitoring, making it suitable for critical power generation and mechanical drive applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003ePeak150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e9905-860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eDigital Microprocessor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Logic\u003c\/td\u003e\n\u003ctd\u003ePID (Proportional-Integral-Derivative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Interface\u003c\/td\u003e\n\u003ctd\u003eDual Magnetic Pickup (MPU) Support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eActuator Driver (4–20 mA or 20–160 mA typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Range\u003c\/td\u003e\n\u003ctd\u003eConfigurable for low and high-speed turbines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Functions\u003c\/td\u003e\n\u003ctd\u003eLost speed signal detection, hardware health monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.2 cm × 12.4 cm × 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe 9905-860 is widely deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine speed and load control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump and compressor constant-speed control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuxiliary power generation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial plants requiring continuous operation during grid transitions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts bumpless transfer capability between speed and load control modes helps maintain process stability during power system fluctuations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 9905-860 support remote setpoint control?\u003c\/strong\u003e\u003cbr\u003eYes. The controller typically accepts external\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA analog signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor remote speed or load setpoint adjustments via DCS or PLC systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the speed signal is lost?\u003c\/strong\u003e\u003cbr\u003eThe controller automatically triggers safety logic that initiates a controlled shutdown or emergency trip to prevent turbine overspeed damage.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751033596,"sku":"9905-860","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9905-860.jpg?v=1772521831"},{"product_id":"woodward-micronet-5441-693-relay-output-i-o-module","title":"Woodward MicroNet 5441-693 Relay Output I\/O Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5441-693\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability relay output module developed by Woodward for the MicroNet control platform. It functions as a discrete dry-contact interface, allowing the control system to actuate high-power field devices such as motor starters, solenoids, breaker coils, and alarm circuits while maintaining full electrical isolation from sensitive logic electronics.\u003c\/p\u003e\n\u003cp\u003eDesigned for synchronization, sequencing, and shutdown logic, the 5441-693 provides fail-safe mechanical contact closure where deterministic and safety-critical operation is required. Its rugged construction ensures stable performance in power plants, turbine control cabinets, and heavy industrial engine rooms, even under frequent switching cycles.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e5441-693\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eRelay Output I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Dry Contact Relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Compatibility\u003c\/td\u003e\n\u003ctd\u003eMicroNet Simplex, Plus, TMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard MicroNet VME-style slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003ePowered via internal backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation (field to control bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e19.1 cm × 2.5 cm × 23.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eThe 5441-693 is widely used in turbine control and heavy machinery governor systems, particularly in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency Shutdown (ESD) logic\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGenerator breaker trip circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAuxiliary pump and lube oil system sequencing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlarm and annunciation outputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSynchronization permissive circuits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is especially suitable for applications requiring mechanical relay outputs for safety compliance, redundancy architectures, or high inductive loads.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5441-693 be used in a TMR (Triple Modular Redundant) system?\u003c\/strong\u003e\u003cbr\u003eYes. The module is fully compatible with MicroNet TMR systems and is commonly used in 2-out-of-3 voting logic for safety-critical relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the module include internal fuse protection?\u003c\/strong\u003e\u003cbr\u003eWhile board-level protection may be present, external fusing of field loads is strongly recommended to protect relay contacts and ensure long-term operational reliability.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751197436,"sku":"5441-693","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5441-6932.jpg?v=1772521831"},{"product_id":"woodward-5464-414-digital-microprocessor-speed-sensor-module","title":"Woodward 5464-414 Digital Microprocessor Speed Sensor Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-414\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance digital speed sensing module developed for the Woodward MicroNet control platform. This microprocessor-based module interfaces with magnetic pickups (MPUs) or active proximity probes to deliver precise rotational speed measurements to the system CPU.\u003c\/p\u003e\n\u003cp\u003eDesigned for critical prime mover applications—including gas turbines, steam turbines, and large reciprocating engines—the 5464-414 uses advanced digital signal processing and high-resolution pulse counting to ensure accurate and stable RPM detection. Its onboard microprocessor performs independent signal validation and filtering, enhancing reliability in high-vibration and high-EMI industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe module is housed in a rugged plug-in chassis format compatible with MicroNet Simplex and Triple Modular Redundant (TMR) systems. Software-configurable speed ranges and alarm setpoints allow flexible deployment for overspeed protection, governor control, and safety-instrumented functions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e5464-414\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eMicroNet Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eDigital microprocessor-based speed sensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Type\u003c\/td\u003e\n\u003ctd\u003eMagnetic Pickup (MPU) or active proximity probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003eUp to 25 kHz+ (turbine applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Method\u003c\/td\u003e\n\u003ctd\u003eOnboard microprocessor with digital filtering\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution digital pulse counting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eMicroNet Simplex and TMR chassis compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.6 cm × 24.8 cm × 26.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 0.96 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eThe 5464-414 is widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine speed monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine overspeed protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge reciprocating engine governor control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCombined-cycle power plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffshore oil and gas platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety Instrumented Systems (SIS) requiring redundant speed signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is especially suited for overspeed protection racks where independent, hardware-based RPM verification is required for safety compliance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5464-414 detect low-speed conditions?\u003c\/strong\u003e\u003cbr\u003eYes. The digital microprocessor design allows accurate tracking of very low frequencies during turbine startup, turning gear operation, and coast-down phases, offering a wide dynamic measurement range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 5464-414 compatible with TMR systems?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports MicroNet Triple Modular Redundant (TMR) configurations, enabling 2-out-of-3 voting logic for safety-critical speed monitoring applications.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751328508,"sku":"5464-414","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-414.jpg?v=1772521830"},{"product_id":"5466-353-transceiver-interface-module-woodward","title":"5466-353 Transceiver Interface Module Woodward","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-353\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed Main Transceiver Interface module designed for the Woodward MicroNet control platform. It functions as a communication bridge between the central processor and distributed remote I\/O nodes, ensuring deterministic and synchronized data exchange across the control network.\u003c\/p\u003e\n\u003cp\u003eEngineered for demanding turbine and power generation environments, the 5466-353 provides robust signal integrity and stable high-speed communication over Woodward’s proprietary MicroNet backplane bus. The module is optimized for applications where millisecond-level response and system coordination are critical, such as gas and steam turbine control systems.\u003c\/p\u003e\n\u003cp\u003eDesigned as a plug-in module for MicroNet VME-based chassis architectures, it offers a compact footprint while maintaining high reliability for continuous industrial operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e5466-353\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eMain Transceiver Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eWoodward MicroNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eProprietary MicroNet high-speed bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003ePlug-in module (VME-based chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eBackplane powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e191 mm × 25 mm × 235 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eThe 5466-353 is typically deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMicroNet Simplex control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTriple Modular Redundant (TMR) architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine sequencing control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine governor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor anti-surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt acts as the physical communication layer within Woodward’s distributed control topology, ensuring stable and deterministic data transfer between CPUs and field I\/O modules.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnical FAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 5466-353 hot-swappable?\u003c\/strong\u003e\u003cbr\u003eAlthough MicroNet systems support modular architectures, it is recommended to follow Woodward’s official shutdown and replacement procedures before removing or installing the module to prevent communication bus disturbances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow can module health be verified?\u003c\/strong\u003e\u003cbr\u003eThe front panel typically includes diagnostic status LEDs indicating communication activity and internal hardware status, allowing quick visual confirmation of operational integrity.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751492348,"sku":"5466-353","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-414.jpg?v=1772521830"},{"product_id":"operator-interface-panel-woodward-series-5453-203","title":"Operator Interface Panel Woodward Series 5453-203","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a ruggedized human-machine interface (HMI) developed by Woodward for use with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet and MicroNet Plus control platforms\u003c\/strong\u003e. This 2-line alphanumeric display panel provides operators with direct access to critical turbine and engine control data, including speed, load, and diagnostic fault codes, without requiring a remote engineering workstation.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for harsh industrial environments such as turbine control rooms, offshore engine rooms, and power plant control cabinets. The high-contrast display ensures visibility under varying lighting conditions, while the durable tactile keypad allows operation even when wearing protective industrial gloves.\u003c\/p\u003e\n\u003cp\u003eThis HMI serves as a local operator interface for monitoring system health and performing basic control interactions during commissioning, troubleshooting, and routine maintenance activities. It communicates directly with the MicroNet CPU through dedicated serial or Ethernet links (configuration dependent).\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e5453-203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eMicroNet Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e2-Line Alphanumeric Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eReal-time monitoring and alarm acknowledgment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eMicroNet serial or Ethernet (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003eIndustrial tactile membrane keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e305 mm × 356 mm × 152 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.82 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine governor control panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge reciprocating engine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation plant operator panels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical functions include monitoring lubrication pressure, turbine speed, load sharing status, and synchronization parameters.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5453-203 be used to modify PID tuning parameters?\u003c\/strong\u003e\u003cbr\u003eYes. If permitted by security settings in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward GAP (Graphical Application Programmer)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware, authorized operators can adjust control setpoints and tuning parameters directly from the keypad interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this display compatible with Netcon 5000 systems?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for MicroNet architecture. Communication protocols and mounting designs differ from older Netcon platforms, so compatibility must be verified before retrofitting.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751557884,"sku":"5453-203","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5453-203.jpg?v=1772435089"},{"product_id":"woodward-8200-226-servo-position-controller","title":"Woodward 8200-226 Servo Position Controller","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8200-226\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision digital servo position controller developed by Woodward for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNetcon\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol system architectures. This module provides closed-loop servo positioning control for hydraulic or pneumatic actuators used in turbine fuel systems and steam valve control applications.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8200-226\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocesses high-resolution feedback signals from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLVDT (Linear Variable Differential Transformer)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRVDT (Rotary Variable Differential Transformer)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esensors, ensuring accurate actuator positioning relative to CPU command signals. This level of precision is essential for stable turbine operation, fuel efficiency optimization, and grid frequency stability.\u003c\/p\u003e\n\u003cp\u003eThe module incorporates advanced deterministic PID control algorithms optimized for fast actuator response. It also supports automatic calibration functions such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enull-seeking\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espan adjustment\u003c\/strong\u003e, significantly reducing commissioning time during plant startup or maintenance activities. Its ruggedized design enables reliable operation in high-vibration and high-temperature environments commonly found in power generation facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e8200-226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Architecture\u003c\/td\u003e\n\u003ctd\u003eClosed-loop digital servo control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback Compatibility\u003c\/td\u003e\n\u003ctd\u003eLVDT, RVDT, 4–20 mA position feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Drive\u003c\/td\u003e\n\u003ctd\u003eConfigurable current output for servo valves\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Interface\u003c\/td\u003e\n\u003ctd\u003eMicroNet \/ Netcon VME backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics\u003c\/td\u003e\n\u003ctd\u003eReal-time feedback integrity and coil resistance monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e32.9 cm × 20.3 cm × 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8200-226\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine governor control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam turbine valve positioning control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFuel rack positioning systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial mechanical drive actuator control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module is critical for maintaining precise combustion control and mechanical stability in high-value rotating machinery.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 8200-226 support redundant feedback?\u003c\/strong\u003e\u003cbr\u003eYes. The module can monitor dual-redundant LVDT sensors. If a large deviation between sensors is detected, the system can automatically switch to the healthy sensor or generate a fault condition for safety protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is the module calibrated?\u003c\/strong\u003e\u003cbr\u003eCalibration is typically performed using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward GAP (Graphical Application Programmer)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware or dedicated handheld programming tools, allowing engineers to electronically define actuator mechanical limits and control parameters.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751623420,"sku":"8200-226","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8200-2261.jpg?v=1772435089"},{"product_id":"8901-037-woodward-booster-servo-motor","title":"8901-037  Woodward Booster Servo Motor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8901-037\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance booster servo actuator manufactured by Woodward for precision mechanical actuation in industrial control systems. This servo motor is designed to convert low-power electronic control signals into high-force mechanical motion, enabling accurate positioning of fuel control valves, steam admission valves, and mechanical linkage assemblies.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8901-037\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in prime mover control systems, including turbine and engine governor applications, where deterministic response and low hysteresis are critical. Its rugged construction allows reliable operation in harsh industrial environments such as turbine enclosures and engine rooms.\u003c\/p\u003e\n\u003cp\u003eEngineered for thermal and mechanical stability, the servo maintains consistent torque output across a wide temperature range. Precision internal components and high-quality winding materials ensure long operational life with reduced maintenance requirements while maintaining accurate actuator positioning in dynamic load conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003e8901-037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003eBooster Servo Motor \/ Hydraulic-Mechanical Actuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque \/ Output Force\u003c\/td\u003e\n\u003ctd\u003eHigh-inertia valve positioning optimized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +90°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eCorrosion-resistant industrial alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty Cycle\u003c\/td\u003e\n\u003ctd\u003eContinuous 24\/7 operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35 mm × 7.5 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8901-037\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine and steam turbine governor control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiesel engine speed and load regulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation frequency stabilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor and mechanical drive actuator positioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is particularly important in applications requiring precise fuel rack synchronization and steam flow control to maintain stable grid frequency and system pressure balance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 8901-037 be used in hazardous locations?\u003c\/strong\u003e\u003cbr\u003eYes. The servo is typically installed inside protective control enclosures. Hazardous area suitability depends on the specific certification listed on the product nameplate (such as Class I, Division 2 environments).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this motor compatible with 2301A or 723 Plus governors?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8901-037\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to interface with a wide range of Woodward governor systems. However, depending on governor output characteristics, an intermediate driver amplifier may be required to achieve full torque performance.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751721724,"sku":"8901-037","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8901-037.jpg?v=1772439701"},{"product_id":"5437-672-woodward-field-terminal-module-ftm","title":"5437-672 Woodward Field Terminal Module FTM","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5437-672\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a Field Terminal Module (FTM) developed by Woodward for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNetcon control system architecture\u003c\/strong\u003e. This module serves as the physical termination and routing interface between field instrumentation and high-speed control electronics inside the control rack.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5437-672\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenables organized and reliable termination of industrial I\/O wiring, ensuring that sensor and actuator signals are transmitted through shielded multi-pin cabling to the appropriate Netcon I\/O processing modules.\u003c\/p\u003e\n\u003cp\u003eDesigned for turbine control and power generation environments, the module emphasizes long-term electrical stability, vibration resistance, and thermal durability. By separating field wiring from active control electronics, it allows technicians to replace electronic modules without disturbing permanent plant wiring infrastructure, significantly improving maintenance efficiency and plant uptime.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e5437-672\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eNetcon 5000 \/ Netcon Control Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eField wiring termination and signal routing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Side Connection\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty screw terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Side Connection\u003c\/td\u003e\n\u003ctd\u003eMulti-pin industrial header\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or bulkhead mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.9 cm × 8.9 cm × 6.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5437-672\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas and steam turbine control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReciprocating engine control platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation and marine propulsion control cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical uses include termination of:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFuel valve control signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTemperature monitoring loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure transmitter wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiscrete control signals for auxiliary machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 5437-672 contain active electronic components?\u003c\/strong\u003e\u003cbr\u003eNo. The module is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epassive termination device\u003c\/strong\u003e, which improves reliability by eliminating active electronic failure points between field devices and the controller.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable is required to connect this FTM to the Netcon rack?\u003c\/strong\u003e\u003cbr\u003eThe module typically uses a proprietary shielded multi-core cable supplied by Woodward. Cable length and connector selection depend on the physical distance between the termination cabinet and the main CPU rack.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751820028,"sku":"5437-672","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5437-6722.jpg?v=1772435090"},{"product_id":"woodward-9907-175-load-sharing-speed-control-module","title":"Woodward 9907-175 Load Sharing Speed Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog load sharing control module developed by Woodward for synchronized power generation and prime mover control systems. This module is widely used in parallel generator applications to ensure balanced real-power distribution across multiple generator sets operating on a shared electrical bus.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einterfaces directly with electronic speed governors to regulate engine speed based on load demand. By continuously monitoring generator real power output, the module adjusts prime mover speed bias signals to maintain stable load sharing. This prevents conditions such as generator motoring or overload stress on individual units.\u003c\/p\u003e\n\u003cp\u003eDesigned for mission-critical power infrastructure, the module supports both diesel and gas engine-driven generator systems. Its analog control architecture delivers deterministic real-time response for legacy and modern power plants where synchronization stability and frequency control are essential.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e9907-175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Type\u003c\/td\u003e\n\u003ctd\u003eAnalog proportional load sharing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eVoltage bias signal for governor interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e24 Vdc (isolated \/ non-isolated variants available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Operation\u003c\/td\u003e\n\u003ctd\u003eSupports multiple generators on common load-sharing bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment Controls\u003c\/td\u003e\n\u003ctd\u003eExternal potentiometers for Gain, Stability, Load Balance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e27.4 cm × 21.3 cm × 6.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-175\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEmergency standby power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine propulsion generator control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eData center backup power synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas offshore platform power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIslanded microgrid power networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is especially critical in facilities requiring stable 50\/60 Hz frequency regulation under dynamic load conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 9907-175 be used with non-Woodward governors?\u003c\/strong\u003e\u003cbr\u003eYes. The module provides flexible voltage bias outputs compatible with most major electronic governor brands, provided input impedance and signal range requirements are matched.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle Droop vs Isochronous load sharing?\u003c\/strong\u003e\u003cbr\u003eThe module is primarily designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIsochronous load sharing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing load-sharing lines to maintain constant frequency. However, it can also support\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDroop mode\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigurations for grid-connected or utility-scale power systems.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746751885564,"sku":"9907-175","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-1751.jpg?v=1772435090"},{"product_id":"remote-chassis-transceiver-woodward-5466-355","title":"Remote Chassis Transceiver Woodward 5466-355","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-355\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-speed bus extension interface developed by Woodward for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet VME control system architecture\u003c\/strong\u003e. This Remote Chassis Transceiver (XCvR) is designed to extend communication between the primary control rack and expansion chassis, enabling distributed control hardware to function as a unified deterministic control platform.\u003c\/p\u003e\n\u003cp\u003eSpecifically optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU 68040-based MicroNet systems\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-355\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides transparent VME bus extension, allowing control logic, memory addressing, and process data to be synchronized across multiple chassis with minimal communication latency.\u003c\/p\u003e\n\u003cp\u003eThe module operates using high-speed differential parallel bus signaling with advanced line drivers to maintain signal integrity across long cable runs. Daisy-chain topology is used for multi-chassis deployments, with termination resistors required at the final node to prevent signal reflections and bus instability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003e5466-355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eMicroNet VME (CPU 68040 compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003eDedicated Slot 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eDual 100-pin Micro-D connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Protocol\u003c\/td\u003e\n\u003ctd\u003eHigh-speed differential parallel bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermination Options\u003c\/td\u003e\n\u003ctd\u003eNon-terminated (intermediate) \/ Terminated (end-of-line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.86 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-355\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be installed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSlot 11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof each expansion chassis for proper bus communication.\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIntermediate chassis in a multi-rack system should use non-terminated modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe final chassis in the communication chain must use a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eterminated variant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith internal termination resistors to maintain signal stability and prevent data reflection on the VME bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy does the module have no LED indicators?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-355\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed as a transparent high-speed communication bridge. System diagnostics are performed by the main XCvR module and CPU software, which monitor bus performance and report errors via control system diagnostics interfaces.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module compatible with newer MicroNet Plus CPU systems?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-355\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewas specifically designed for 68040 VME bus timing. Compatibility with newer CPU architectures must be verified, as bus timing mismatches can lead to communication errors or data corruption.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746754146556,"sku":"5466-355","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5466-257.jpg?v=1772435089"},{"product_id":"woodward-5466-257-analog-i-o-module","title":"Woodward 5466-257 Analog I\/O Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-257\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog I\/O expansion module engineered by Woodward for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet control platforms\u003c\/strong\u003e, including TMR and Simplex architectures. This module is designed for high-speed deterministic control of large prime movers such as steam and gas turbines.\u003c\/p\u003e\n\u003cp\u003eThe module provides a centralized interface for multiple analog process signals, converting field sensor data into digital control information with minimal latency. It is optimized for turbine control loops where precise fuel, actuator, and process regulation is required.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-257\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for high-density control cabinets and supports multiple control loops from a single chassis slot. Integrated onboard diagnostics continuously monitor A\/D and D\/A conversion integrity as well as output driver health, helping prevent control drift that could lead to combustion inefficiency or mechanical stress in rotating machinery systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e5466-257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eMicroNet Simplex, MicroNet Plus, MicroNet TMR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8–16 configurable (hardware dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit A\/D and D\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e5 ms or 10 ms MicroNet control cycle synchronized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 Vrms galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W @ 24 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-257\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGas turbine fuel valve control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eServo actuator positioning loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLube oil pressure monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCooling water and auxiliary process control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIts rugged design allows installation in turbine control cabinets, offshore platform engine rooms, and other harsh industrial environments where vibration and thermal cycling are common.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the 5466-257 be used in TMR configurations?\u003c\/strong\u003e\u003cbr\u003eYes. The module is fully compatible with MicroNet TMR architectures, where three redundant control channels operate using voting logic to prevent single-point failures from causing turbine shutdowns.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support HART communication?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-257\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for high-speed analog signaling only. Applications requiring HART over 4–20 mA communication should use a dedicated HART-capable I\/O module from the MicroNet ecosystem.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746754212092,"sku":"5466-257","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5466-257.jpg?v=1772435089"},{"product_id":"power-supply-module-woodward-5466-318","title":"Power Supply Module Woodward 5466-318","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5466-318\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKernel Power Supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet TMR (Triple Modular Redundant)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5 VDC regulated power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto core processing hardware, including the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTMR040 CPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand backplane logic, by converting a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindustrial feed. The module ensures high availability and system stability by preventing power fluctuations from causing system reboots or processor halts. Its rugged design meets\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCE\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003estandards, making it suitable for hazardous locations.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5466-318\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet TMR Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAssociated CPU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTMR040 Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 VDC (Nominal ±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC (Regulated ±5%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-frequency switching design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between inputs\/outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOver-voltage, short-circuit, thermal shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel LED indicator (Power Supply Health)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5466-318\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis critical in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTriple Modular Redundant (TMR)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems for high-stakes applications like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine control\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enuclear power plants\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical compressors\u003c\/strong\u003e, where control failure could lead to significant safety risks.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be hot-swapped in a running TMR rack?\u003c\/strong\u003e\u003cbr\u003eYes, it can be hot-swapped without shutting down the system in a redundant TMR configuration, as long as the remaining modules handle the current load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module provide power for field I\/O devices?\u003c\/strong\u003e\u003cbr\u003eNo, it only provides power to the internal logic of CPUs and backplanes. Field I\/O devices require separate power sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does a flashing or dark LED indicator signify?\u003c\/strong\u003e\u003cbr\u003eA\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edark LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eloss of input power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecatastrophic internal failure\u003c\/strong\u003e. A\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eflashing or amber LED\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignals that the output voltage is outside the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±5% tolerance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746762043644,"sku":"5466-318","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/121._7db2b3ed-4548-44aa-9991-c8eb1ca71f12.jpg?v=1770264997"},{"product_id":"woodward-5464-013-rtd-input-driver-module","title":"Woodward 5464-013 RTD Input Driver Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5464-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-precision RTD interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. It enables accurate thermal monitoring of critical turbine and engine components like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebearing temperatures\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewinding temperatures\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elube oil systems\u003c\/strong\u003e. By converting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow-level resistance signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100-ohm platinum RTDs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto digital data, it ensures reliable thermal protection logic and minimal signal drift.\u003c\/p\u003e\n\u003cp\u003eThis module features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eeight independent channels\u003c\/strong\u003e, each with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eadvanced filtering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto reject\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMI\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eline noise\u003c\/strong\u003e, ensuring accuracy in high-voltage environments. It also has built-in diagnostic capabilities to detect sensor faults, like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen circuits\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshorted wiring\u003c\/strong\u003e, for proactive protection.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5464-013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRTD Input Interface (Analog)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Independent Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100-ohm Platinum RTDs (European or American Curves)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.1°C (at 25°C ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit to 14-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExcitation Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 mA (internally provided)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-to-Logic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic sensing for open\/short sensor conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Tracking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLinearized data transmission to CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +60°C (Internal rack ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.4kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eCommonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor monitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egenerator stator windings\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethrust bearing temperatures\u003c\/strong\u003e, and in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompressor stations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor monitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einterstage gas temperatures\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elubricant thermal stability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support 3-wire or 4-wire RTD configurations?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-013\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3-wire RTD configurations\u003c\/strong\u003e, ensuring accuracy over long distances by compensating for lead-wire resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I mix different RTD types on a single module?\u003c\/strong\u003e\u003cbr\u003eThe module is configured for a specific\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTD curve\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward GAP® software\u003c\/strong\u003e. Although individual channel ranges can be defined, the same RTD material (e.g., Pt100) should be used across all channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module handle high-frequency vibration on the sensor lines?\u003c\/strong\u003e\u003cbr\u003eThe module includes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog and digital filtering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto suppress high-frequency\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enoise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecommonly found in industrial machinery environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746762174716,"sku":"5464-013","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-0132.jpg?v=1772175919"},{"product_id":"5501-214-woodward-micronet-digital-governor-module","title":"5501-214 Woodward MicroNet Digital Governor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5501-214\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital control module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbo-generators\u003c\/strong\u003e, designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eload\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure regulation\u003c\/strong\u003e. It integrates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-channel I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure efficient operation and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal stability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein harsh environments (-40°C to 85°C). It connects field instrumentation to the control network using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCANopen\u003c\/strong\u003e, ensuring fast, deterministic response times for safety-critical applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24–30 VDC (Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 Channels (Configurable 4–20 mA or 0–5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Channels (Actuator drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 Inputs \/ 8 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Communications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, CANopen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet Chassis Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetroleum refineries\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine control\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel modulation\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evalve sequencing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStandalone Operation\u003c\/strong\u003e: Typically operates with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet CPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebut can work independently with local logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Communications\u003c\/strong\u003e: Supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant paths\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCANopen\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDriving Large Actuators\u003c\/strong\u003e: Standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutputs; for high-current actuators, a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econverter is required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746762305788,"sku":"5501-214","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5501-2142.jpg?v=1772175918"},{"product_id":"5501-365-woodward-analog-input-output-module","title":"5501-365 Woodward Analog Input\/Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density Analog Input\/Output (I\/O)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. It acts as the primary interface between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand field instrumentation in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial turbine\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eengine control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. The module manages the acquisition of critical sensor data (such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressures\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etemperatures\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epositions\u003c\/strong\u003e) while simultaneously driving\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eproportional actuators\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evalves\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike end-element converters, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erack-mounted electronic PCB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat provides the necessary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal conditioning\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor precise\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGovernor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel control loops\u003c\/strong\u003e. It features high-speed sampling rates and sophisticated on-board diagnostics to monitor for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen circuits\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal out-of-range\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efaults, ensuring the highest levels of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem integrity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5501-365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet \/ MicroNet Plus \/ MicroNet Simplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input and Output (Combined I\/O)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channel Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range (I\/O)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSoftware-configurable 4–20 mA or 0–5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal 24 VDC (via backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed parallel backplane bus (RS-485 for specialized diagnostics)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14-bit or 16-bit A\/D and D\/A converters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 Vrms (Field-to-Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronized with CPU task rate (as fast as 5 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +60°C (Internal rack ambient)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mm x 50 mm x 30 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas turbine control systems\u003c\/strong\u003e, where it monitors parameters such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emanifold pressure\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexhaust temperature\u003c\/strong\u003e, while simultaneously controlling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel valve position\u003c\/strong\u003e. Its ability to handle both inputs and outputs on a single card makes it an efficient solution for reducing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echassis space\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein mid-sized control architectures.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan I mix 4-20 mA and 0-5V signals on the same module?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindependent channel configuration\u003c\/strong\u003e, allowing you to mix signal types as required by your specific instrumentation setup.\u003c\/p\u003e\n\u003ch4\u003eIs this module hot-swappable?\u003c\/h4\u003e\n\u003cp\u003eWhen used in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith the appropriate software version, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-replacement\u003c\/strong\u003e. However, standard safety procedures should always be followed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine control systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eHow does the module handle sensor failure?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-365\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eloop monitoring\u003c\/strong\u003e. If a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4–20 mA signal\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edrops below\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(indicating a wire break), the module flags a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault bit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU\u003c\/strong\u003e, allowing the system to initiate a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafe shutdown\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor switch to a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant sensor\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746762436860,"sku":"5501-365","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5501-3651.jpg?v=1772175918"},{"product_id":"5501-367-woodward-analog-i-o-control-module","title":"5501-367 Woodward Analog I\/O Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision analog interface module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. This module acts as a critical bridge between the digital processing core and field instrumentation, enabling the acquisition of sensor data and execution of actuator commands simultaneously. It is specifically engineered for high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eturbine control loops\u003c\/strong\u003e, where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal latency\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eresolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare crucial for system stability and fuel efficiency.\u003c\/p\u003e\n\u003cp\u003eUnlike standard industrial I\/O modules, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efiltering\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto eliminate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eground loop interference\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein complex power generation environments. Each channel is individually calibrated to maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh linearity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross the entire signal range, supporting a variety of current-loop and voltage-based transducers. The module is optimized for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet backplane\u003c\/strong\u003e, allowing for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseamless hot-swapping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring system maintenance.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5501-367\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Input\/Output (I\/O) Expansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple 4–20 mA or 0–5 VDC configurable inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA proportional outputs for actuator and valve control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit to 16-bit (Configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-to-Logic isolation rated for 500 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSynchronized with MicroNet CPU task cycles (typically 5ms to 10ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-board Diagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContinuous monitoring for open loops and out-of-range signals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2 cm x 12.4 cm x 12.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine management systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere it monitors critical parameters like\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eexhaust temperatures\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel pressures\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evalve positions\u003c\/strong\u003e. It is also frequently used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge-scale compressor control trains\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto manage\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanti-surge valve modulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eDoes this module support both current and voltage signals?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis versatile and can support both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage signals\u003c\/strong\u003e. Specific channel types are determined by jumper settings on the module or software configuration in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward GAP®\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironment.\u003c\/p\u003e\n\u003ch4\u003eIs this compatible with the MicroNet Plus redundant chassis?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-367\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis fully compatible with both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSimplex\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePlus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echassis architectures, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant I\/O configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-reliability applications.\u003c\/p\u003e\n\u003ch4\u003eWhat diagnostic feedback does the module provide?\u003c\/h4\u003e\n\u003cp\u003eThe module reports status bits to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor every channel, identifying fault conditions such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent loop breaks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(4mA underflow) or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esensor saturation\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746762502396,"sku":"5501-367","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5501-3671.jpg?v=1772175918"},{"product_id":"cpu-controller-module-woodward-5501-470","title":"CPU Controller Module Woodward 5501-470","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5501-470\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral processing unit (CPU)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Simplex\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. Built on the robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMotorola MPC5200\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitecture, this module is the primary intelligence for large-scale turbine and engine management systems. It handles complex, high-speed control algorithms and sequence logic with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic execution\u003c\/strong\u003e, ensuring critical industrial processes remain stable and responsive.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-470\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures an integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eReal-Time Operating System (RTOS)\u003c\/strong\u003e, facilitating high-speed data exchange across the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet backplane\u003c\/strong\u003e. With dual\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet ports\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor redundant networking and serial ports for diagnostics or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus integration\u003c\/strong\u003e, this module is built for reliability in high-vibration and thermally volatile environments typical of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilities.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5501-470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMotorola MPC5200 (PowerPC core)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Clock Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating System Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVxWorks® based Real-Time OS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOn-board Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 MB DDR RAM \/ 32 MB Flash Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x 10\/100 Base-TX Ethernet (RJ45), 1 x RS-232 Serial (9-pin D-sub), 1 x CAN interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMicroNet Plus 14-slot and 6-slot chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel LED indicators for CPU health, Ethernet link, and system faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with redundant CPU tracking for high-availability systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 15 W via the backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-470\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrolling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-spool gas turbines\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge steam turbines\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompressor sets\u003c\/strong\u003e. It is also frequently deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"Hot-Replacement\" redundant configurations\u003c\/strong\u003e, where a secondary CPU automatically takes over control within milliseconds if the primary unit fails.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eDoes the 5501-470 require an external power supply?\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-470\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edraws its operating power directly from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus chassis backplane\u003c\/strong\u003e, which is powered by the system's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant power supply modules\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eCan I upgrade an older 586-based CPU with this module?\u003c\/h4\u003e\n\u003cp\u003eUpgrading from an older\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e586-based CPU\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emay require migration of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGAP® (Graphical Application Programmer)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware and potentially a revision of the backplane, as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5501-470\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers superior processing power.\u003c\/p\u003e\n\u003ch4\u003eHow is the firmware updated on this unit?\u003c\/h4\u003e\n\u003cp\u003eFirmware and application code are typically loaded through the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet port\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing Woodward's proprietary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAppManager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esoftware tools.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746763223292,"sku":"5501-470","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-0132.jpg?v=1772175919"},{"product_id":"5503-198b-woodward-industrial-control-module","title":"5503-198B Woodward Industrial Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5503-198B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a ruggedized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial computing node\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for complex logic execution and data gateway functions in harsh field environments. It utilizes a high-efficiency\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-bit RISC architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eclocked at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100 MHz\u003c\/strong\u003e, offering deterministic performance for real-time industrial monitoring and subsystem coordination.\u003c\/p\u003e\n\u003cp\u003eWith an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP65-rated housing\u003c\/strong\u003e, the 5503-198B is built to withstand dust ingress and low-pressure water exposure, allowing it to be mounted outside traditional control rooms. It features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ededicated Ethernet stack\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor high-level networking and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual serial interfaces\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor legacy device integration, making it a perfect solution for decentralized control architectures.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5503-198B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCore Processor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC CPU (100 MHz clock speed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolatile Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e512 KB High-speed RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNon-Volatile Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 MB Flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Base-T Ethernet Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Communication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x RS-232\/485 configurable serial ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Operating Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +60°C (-4°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.4 cm x 8.5 cm x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5503-198B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed energy management\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote telemetry units (RTUs)\u003c\/strong\u003e, and as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elocalized communication concentrator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein turbine auxiliary systems. Its rugged design makes it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eskid-mounted equipment\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexposed to ambient industrial contaminants.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eDoes the 5503-198B support Power over Ethernet (PoE)?\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5503-198B\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically requires a dedicated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC power input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor logic stability, as the Ethernet port is used solely for high-speed data transmission.\u003c\/p\u003e\n\u003ch4\u003eIs the memory expandable for data logging?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2 MB Flash\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e512 KB RAM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare fixed resources optimized for code execution. For extensive data logging, the data is typically sent via Ethernet to a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentralized SCADA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehistorian\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746763321596,"sku":"5503-198","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-0132.jpg?v=1772175919"},{"product_id":"5464-658-woodward-digital-speed-sensor-module","title":"5464-658 Woodward Digital Speed Sensor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 5464-658\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed acquisition interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol platforms. This module efficiently tracks rotating machinery velocity by converting raw pulses from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emagnetic pickups (MPUs)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eproximity probes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto precise digital data. By offloading the frequency-to-digital conversion from the main CPU, the 5464-658 ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero-lag speed sensing\u003c\/strong\u003e, even during rapid turbine acceleration or load shedding events.\u003c\/p\u003e\n\u003cp\u003eUnlike standard analog speed converters, this\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003euses high-speed internal counters to maintain a minimum\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12-bit resolution\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross a broad frequency spectrum. Engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efail-safe operation\u003c\/strong\u003e, it continuously monitors input signal health, instantly detecting open circuits or shorted sensors to prevent overspeed conditions.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5464-658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Frequency Spectrum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 Hz to 25,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Acquisition Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.03% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12-bit minimum (High-precision counter-based)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Sensor Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePassive MPUs, Active Proximity Probes, Eddy Current Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 VDC to 32 VDC (Amplitude range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 mA maximum at 12\/24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 mA fuse per speed channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Dynamics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelectable filter time constants (8 ms or 16 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEvent Tracking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 ms resolution for SOE (Sequence-of-Events) logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Threshold\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDetects speeds as low as 0.5 Hz (for barring\/turning gear monitoring)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eField-to-logic isolation for noise immunity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-658\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine control systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed governing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis safety-critical. It is commonly deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egrid synchronization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(e.g., large compressor trains) to monitor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eshaft speed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring startup and shutdown sequences.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan this module power an active proximity probe?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5464-658\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan interface with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eactive sensors\u003c\/strong\u003e, provided the external power supply is shared or appropriately grounded to ensure signal integrity within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3.5–32 VDC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewindow.\u003c\/p\u003e\n\u003ch4\u003eHow does it prevent \"ghost\" speed readings?\u003c\/h4\u003e\n\u003cp\u003eThe module uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprogrammable software filters\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(8 ms\/16 ms) and a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehardware-level minimum frequency threshold\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 Hz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto filter out electrical noise and low-amplitude vibration that could otherwise be misinterpreted as rotation.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746763583740,"sku":"5464-658","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-658.jpg?v=1772175918"},{"product_id":"woodward-9907-023-load-sharing-and-speed-control-module","title":"Woodward 9907-023 Load Sharing and Speed Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 9907-023\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectronic control module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2301A series\u003c\/strong\u003e, designed for the management of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediesel engines\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas engines\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbines\u003c\/strong\u003e. This unit provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision speed governing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic load sharing\u003c\/strong\u003e. By monitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egenerator output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eengine speed\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia a magnetic pickup (MPU), the 9907-023 ensures multiple prime movers operate in parallel, distributing the total electrical load evenly across all units, thus preventing system instability.\u003c\/p\u003e\n\u003cp\u003eThe 9907-023 is ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-voltage applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(115 or 230 VAC input) and is housed in a rugged\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eopen-chassis frame\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor installation within a control cabinet. Using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog circuitry\u003c\/strong\u003e, it offers fast response times to load changes, making it vital for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicrogrids\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emarine vessels\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial power plants\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring seamless synchronization and grid stability.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Designation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9907-023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2301A Load Sharing and Speed Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e115\/230 VAC (Switch-selectable or hard-wired)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed Sensing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-impedance Magnetic Pickup (MPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Sharing Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–3 VDC load sharing lines\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActuator Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0–200 mA (For Woodward proportional actuators)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsochronous and Droop speed control modes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAdjustments\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePotentiometers for Gain, Stability, Low Idle, and Rated Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Construction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHeavy-duty aluminum base for thermal dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.1 cm x 17 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-023\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote power stations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor paralleling multi-engine generator sets. It is frequently employed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emarine propulsion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eauxiliary power systems\u003c\/strong\u003e, where engines must share the load to avoid\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"reverse power\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econditions that could trip circuit breakers.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan this module be used in a single-engine (isochronous) application?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-023\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan operate as a standalone\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed governor\u003c\/strong\u003e, maintaining a constant frequency regardless of load variations on the engine.\u003c\/p\u003e\n\u003ch4\u003eIs this compatible with 24V DC systems?\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-023\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAC-powered\u003c\/strong\u003e. For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems, a different part number from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2301A Low Voltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries would be needed.\u003c\/p\u003e\n\u003ch4\u003eHow does it handle \"Droop\" operation?\u003c\/h4\u003e\n\u003cp\u003eWhen the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"Droop\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtact is closed, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-023\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the speed to decrease slightly as the load increases. This is essential when paralleling with an infinite utility grid to ensure stable operation.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746763714812,"sku":"9907-023","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-023.jpg?v=1772175918"},{"product_id":"woodward-9907-162-digital-steam-turbine-controller","title":"Woodward 9907-162 Digital Steam Turbine Controller","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 9907-162\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital control unit from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePeak 150\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries, designed for precise governing of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econstant-speed steam turbines\u003c\/strong\u003e. This microprocessor-based controller replaces obsolete mechanical-hydraulic governors and is tailored for turbines driving\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentrifugal pumps\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efans\u003c\/strong\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompressors\u003c\/strong\u003e. By processing high-speed magnetic pickup signals, the 9907-162 ensures accurate speed control and rapid response to load changes.\u003c\/p\u003e\n\u003cp\u003eBuilt for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield-mounting\u003c\/strong\u003e, the 9907-162 features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEMA 4X rated enclosure\u003c\/strong\u003e, making it resistant to moisture, dust, and corrosive vapors found in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments. The interface allows direct calibration of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePID dynamics\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed setpoints\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoverspeed trip logic\u003c\/strong\u003e, ensuring safe and efficient operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9907-162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle-valve Steam Turbine Governor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSpeed Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Magnetic Pickup (MPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA or 0–200 mA (Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable relay outputs for Alarms and Shutdowns; Contact inputs for Remote Reset\/Start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X (Weatherproof and corrosion-resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS-232 \/ RS-422 Service Port for PC-based configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27 cm x 35 cm x 10 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication \u0026amp; Engineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eCan the 9907-162 be used for generator synchronization?\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePeak 150\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(such as pumps and compressors). For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egenerator load sharing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand synchronization, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 505\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2301D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries would be more appropriate.\u003c\/p\u003e\n\u003ch4\u003eWhat happens if the speed signal is lost?\u003c\/h4\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-162\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehas a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLoss of Speed Detection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecircuit that triggers an immediate safety shutdown (trip) to prevent uncontrolled turbine acceleration.\u003c\/p\u003e\n\u003ch4\u003eIs the enclosure suitable for outdoor installation?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEMA 4X\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenclosure is designed for outdoor use, but it is recommended to install a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esunshade\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein high-temperature tropical climates to protect internal components and prolong their lifespan.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746763878652,"sku":"9907-162","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-162.jpg?v=1772175918"},{"product_id":"9907-028-woodward-spm-a-speed-and-phase-synchronizer","title":"9907-028 Woodward SPM-A Speed and Phase Synchronizer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 9907-028\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog-based synchronization module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPM-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eline, designed to provide automatic\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efrequency\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ephase matching\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor engine-generator sets. It generates a corrective bias signal to the speed governor, ensuring that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecircuit breaker\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecloses only when the generator and bus are within safe limits, preventing mechanical stress and electrical surges.\u003c\/p\u003e\n\u003cp\u003eAs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSpeed and Phase Matching (SPM)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-028\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ealigns the temporal relationship of the sine waves between the generator and bus. Known for its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edurability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein extreme environments, it features an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eanalog architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epreferred for its reliability in legacy systems and immunity to digital software complexities.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9907-028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSPM-A (Synchronizer Package – Analog)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-tap 115\/230 VAC RMS (Configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz Compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhase Angle Window\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed\/Adjustable to ±10° for breaker closure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Matching Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNone (Focus on speed and phase only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤5 W (Ultra-low efficiency)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-45°C to +70°C (-49°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChassis Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e273.6 mm x 214.1 mm x 59.2 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.71 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-028\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandby power plants\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emarine auxiliary power systems\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial microgrids\u003c\/strong\u003e. It is the preferred choice for paralleling\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediesel\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas engines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein systems where\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esimple\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efast phase-matching\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis needed without integrated voltage regulation.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eDoes this unit adjust the generator's voltage?\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-028\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eonly matches phase and speed. For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eautomatic voltage matching\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(AVM), a different\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPM-A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evariant or a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edigital SPM-D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eunit is needed.\u003c\/p\u003e\n\u003ch4\u003eCan the phase angle window be adjusted tighter than 10 degrees?\u003c\/h4\u003e\n\u003cp\u003eThe nominal window is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e±10°\u003c\/strong\u003e, but\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einternal potentiometers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallow fine-tuning to match the response time of your specific circuit breaker for seamless contact closure.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746763976956,"sku":"9907-028","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-0282.jpg?v=1772175918"},{"product_id":"8440-2165-woodward-generator-synchronizer","title":"8440-2165 Woodward Generator Synchronizer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 8440-2165\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a microprocessor-based synchronizer from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSPM-D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efamily, designed for seamless synchronization of three-phase AC generators. It ensures safe, transient-free breaker closure by matching the phase angle, frequency, and voltage of the generator to the busbar. This unit is ideal for applications requiring automated synchronization, such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed power systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eemergency standby generators\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 8440-2165 features a high-visibility display for real-time synchronization monitoring and uses PID control for speed and voltage biasing, making it an essential tool for precise power management.\u003c\/p\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8440-2165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSPM-D (Synchronizer Package Microprocessor - Digital)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Measurement Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 VAC (Nominal secondary voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent Measurement Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 A (Secondary current transformer rating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSynchronization Logic\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePhase-match and Slip-frequency synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Matching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated voltage matching for excitation control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable bias signals for speed governors and AVRs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C (Max 100°C for storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2kg\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-2165\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower plants\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecogeneration facilities\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical backup systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as hospitals or data centers. It is ideal for automating the paralleling of a generator to a utility grid or common busbar without manual intervention.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eDoes the 8440-2165 support dead-bus closing?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-2165\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be configured to allow the generator to close onto a de-energized busbar, depending on system requirements.\u003c\/p\u003e\n\u003ch4\u003eCan it interface with non-Woodward governors?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-2165\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutputs standardized analog bias signals (e.g., ±3V or 4-20mA), making it compatible with most third-party governors and Automatic Voltage Regulators (AVRs).\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746764009724,"sku":"8440-2165","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8440-2165.jpg?v=1772177936"},{"product_id":"8200-1302-woodward-digital-governor-control-system","title":"8200-1302 Woodward Digital Governor Control System","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 8200-1302\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital governor designed for precise steam turbine regulation, replacing outdated mechanical or analog systems. It enhances fuel efficiency and stability, ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaritime\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial applications\u003c\/strong\u003e. Built with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP-54 protection\u003c\/strong\u003e, it operates in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePollution Degree 3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments with high-vibration resistance. It also meets\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEMC immunity standards\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto prevent interference from nearby machinery.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8200-1302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital Governing \u0026amp; Steam Turbine Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–36 VDC (Fully Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA channels (Integrated Loop Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP-54 (Dust \u0026amp; splash resistant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eATEX, IACS UR E10 (Maritime)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN 61000-6-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-30°C to 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eUsed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecommercial shipping fleets\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epropulsion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eauxiliary power\u003c\/strong\u003e, as well as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbines\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATEX-certified\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindustrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003ch4\u003eIs the 8200-1302 compatible with redundant power feeds?\u003c\/h4\u003e\n\u003cp\u003eYes, it supports integration into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant DC power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems.\u003c\/p\u003e\n\u003ch4\u003eDoes it require an external cooling fan?\u003c\/h4\u003e\n\u003cp\u003eNo, it uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epassive cooling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin its operating temperature range.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746764370172,"sku":"8200-1302","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8200-1302.jpg?v=1772175918"},{"product_id":"operator-interface-module-woodward-8406-003","title":"Operator Interface Module Woodward 8406-003","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 8406-003\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-integrity Human-Machine Interface (HMI) for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGEN PART 6000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtrol architecture. Designed for high-speed visualization and command execution, this terminal enables plant operators to manage complex compressor and turbine sequences through a centralized, industrial-grade hardware platform. Unlike standard commercial displays, the 8406-003 is built on a hardened micro-kernel architecture to ensure deterministic response times in mission-critical environments.\u003c\/p\u003e\n\u003cp\u003eSafety and cybersecurity are foundational to the design of the 8406-003. Running on a specialized version of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVxWorks® Real-Time Operating System (RTOS)\u003c\/strong\u003e, the module offers a stable environment resistant to common malware and system hangs. It features a comprehensive security suite tailored for utility-scale energy infrastructure, including embedded firewalls and encrypted communication channels.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGEN PART 6000 \/ GAP® Compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8406-003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating System\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVxWorks® RTOS 6.8 (Secure Edition)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCybersecurity Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNERC\/CIP standards-ready\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEncryption Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Secure Shell (SSH) and encrypted protocol tunneling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEmbedded firewall, Authenticated user access, NERC-compliant Password Management\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Redundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFull support for redundant controller configurations with seamless failover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSoftware Integration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGAP® security block update capability for evolving threat landscapes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated for ATEX hazardous zones and Marine-grade deployments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.69 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8406-003\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHMI is used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoffshore oil and gas platforms\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote power generation sites\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaritime propulsion control systems\u003c\/strong\u003e. Its ability to maintain secure communications across wide-area networks makes it the standard for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNERC\/CIP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eregulated utilities requiring remote monitoring and local override capabilities.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003ch4\u003eHow does the 8406-003 handle unauthorized network traffic?\u003c\/h4\u003e\n\u003cp\u003eThe unit features an integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehardware-level firewall\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat filters incoming packets, ensuring only authenticated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward protocol\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etraffic reaches the core processing logic.\u003c\/p\u003e\n\u003ch4\u003eIs the unit field-upgradable for security patches?\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8406-003\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports regular\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etool and protocol updates\u003c\/strong\u003e, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGAP® security blocks\u003c\/strong\u003e, enabling the hardware to adapt to evolving cybersecurity requirements without the need for a complete replacement.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746764763388,"sku":"8406-003","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8406-003.jpg?v=1772175919"},{"product_id":"9907-827-505-woodward-digital-turbine-governor","title":"9907-827 505 Woodward Digital Turbine Governor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-827\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield-proven digital control platform\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 505 series\u003c\/strong\u003e, specifically engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecision management of single-valve steam turbines\u003c\/strong\u003e. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emicroprocessor-based governor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexcels at regulating turbine speed and load, offering a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandalone operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand integration into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eplant networks\u003c\/strong\u003e. Replacing older analog systems, it features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed digital logic core\u003c\/strong\u003e, ensuring tighter frequency control and faster transient response during\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eload rejection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egrid fluctuations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEquipped with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomprehensive graphical LCD\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-827\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows operators to monitor real-time\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePID performance\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ealarm logs\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem diagnostics\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithout the need for external handheld programmers. The unit is designed specifically for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"single-extraction\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\"straight-condensing\"\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eturbine architectures, providing specialized algorithms for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed regulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e18–32 VDC (24 VDC Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpeed Control, Load Sharing, Remote Speed Setpoint, and Extraction Pressure Regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperator Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated Front-Panel Graphical LCD with Tactile Keypad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, ±5 VDC, or ±10 VDC (Configurable for transducers or remote setpoints)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiple 4–20 mA channels for actuators, tachometers, or remote monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiscrete I\/O\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable dry contact inputs and relay outputs for trip\/alarm logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual RS-232 and RS-485 ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNetwork Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU (Slave) for DCS\/SCADA integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eIndustrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-827\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis primarily used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive systems\u003c\/strong\u003e. It is widely deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esugar mills\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epaper plants\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing facilities\u003c\/strong\u003e, where precise\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam extraction\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis critical for balancing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess heat\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectrical output\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eCan this unit handle dual-extraction turbines?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-827\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-valve\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle-extraction steam turbines\u003c\/strong\u003e. For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-extraction\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eturbines, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward 505E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis recommended.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eIs the Modbus communication bi-directional?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus RTU protocol\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eboth data monitoring (reads)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote setpoint adjustments (writes)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom a central\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaster station\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746764828924,"sku":"9907-827","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-8272.jpg?v=1772176146"},{"product_id":"woodward-micronet-plus-14-slot-chassis-5453-759-control-system-platform","title":"Woodward MicroNet Plus 14-Slot Chassis 5453-759 Control System Platform","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus 5453-759\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e14-slot chassis\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat serves as the primary structural and electrical foundation for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward’s high-performance control systems\u003c\/strong\u003e. Specifically engineered for demanding\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas turbine management\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge-scale industrial engine control\u003c\/strong\u003e, the chassis utilizes a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodular backplane\u003c\/strong\u003e, facilitating\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed data transfer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPU modules\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower supplies\u003c\/strong\u003e, and various\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eI\/O conditioning cards\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-759\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem availability\u003c\/strong\u003e. It supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehardware redundancy\u003c\/strong\u003e, enabling the configuration of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual power supplies\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emirrored control modules\u003c\/strong\u003e, effectively eliminating\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle points of failure\u003c\/strong\u003e. Its physical construction is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecabinet mounting\u003c\/strong\u003e, featuring a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erugged metallic frame\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectromagnetic interference (EMI) shielding\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal dissipation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the internal components, ensuring reliable operation in harsh industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5453-759\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14 Total Slots (Supporting CPU, I\/O, and Communication modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication Focus\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGas Turbine Control, Steam Turbine Sequencing, Compressor Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Rack\/Panel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated backplane for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSerial\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFieldbus\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eexpansion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 cm x 16 cm x 12 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Integrity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh vibration resistance and wide temperature tolerance for turbine deck environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus 5453-759\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003echassis is primarily used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation facilities\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emechanical drive applications\u003c\/strong\u003e. It is the preferred choice for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eretrofitting legacy turbine controllers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density I\/O\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erapid processing cycles\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare critical for functions such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esurge protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efuel valve modulation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003e\u003cstrong\u003eCommon Engineering FAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eDoes this chassis include the power supply?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eNo, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e5453-759\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebare chassis\u003c\/strong\u003e.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePower supply modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emust be sourced separately, based on your specific\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundancy requirements\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eCan I mix different I\/O types in the 14 slots?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMicroNet Plus backplane\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for flexible\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodule placement\u003c\/strong\u003e. However, specific slot assignments for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCPUs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare typically required according to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward's logic mapping\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746764894460,"sku":"5453-759","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5453-759.jpg?v=1772175983"},{"product_id":"woodward-9907-031-digital-speed-control-module","title":"Woodward 9907-031 Digital Speed Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-031\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital control module from Woodward Inc.’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2301D series\u003c\/strong\u003e, designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espeed governing, load sharing, and synchronization control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof reciprocating engines (diesel, gas, or gasoline).\u003c\/p\u003e\n\u003cp\u003eAs the digital successor to the 2301A analog governor, it provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esoftware-configurable control logic\u003c\/strong\u003e, improved stability, and higher precision engine dynamics management. The module is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical power generation\u003c\/strong\u003e, marine propulsion, and standby power systems.\u003c\/p\u003e\n\u003cp\u003eThe controller supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-speed sensing inputs\u003c\/strong\u003e, enabling redundant safety monitoring and improved overspeed protection reliability.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9907-031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e2301D Digital Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eEngine speed, load sharing, synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Inputs\u003c\/td\u003e\n\u003ctd\u003eDual MPU or proximity switch inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e40 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O\u003c\/td\u003e\n\u003ctd\u003eConfigurable discrete inputs\/outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O\u003c\/td\u003e\n\u003ctd\u003eRemote setpoint and fuel control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eCore Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic load sharing between generator sets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBumpless synchronization with live electrical bus systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable start\/stop and safety interlock logic using LogicsManager\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-speed input redundancy for improved safety reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it replace the 2301A analog governor?\u003c\/strong\u003e\u003cbr\u003eYes, but configuration must be performed using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWoodward Watch Window software\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto tune PID parameters for specific engine applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy use dual-speed inputs?\u003c\/strong\u003e\u003cbr\u003eDual inputs provide\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundancy and cross-check validation\u003c\/strong\u003e, improving overspeed protection and system reliability.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746764992764,"sku":"9907-031","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-031.jpg?v=1772090728"},{"product_id":"woodward-8400-016-digital-speed-controller","title":"Woodward 8400-016 Digital Speed Controller","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8400-016\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance digital governor module from Woodward Inc., designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eengine and turbine speed control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications. It provides precise governing between speed sensing devices (such as magnetic pickups) and fuel or throttle actuation systems.\u003c\/p\u003e\n\u003cp\u003eThe module maintains stable rotational speed under varying load conditions using advanced digital PID control algorithms, making it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation, marine propulsion, and industrial prime mover control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications. Its compact, ruggedized design reduces cabinet space while maintaining high resistance to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evibration and electromagnetic interference (EMI)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8400-016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eDigital Turbine\/Engine Governor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e18 – 32 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Compatibility\u003c\/td\u003e\n\u003ctd\u003ePassive and active MPU sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Algorithm\u003c\/td\u003e\n\u003ctd\u003ePID control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Stability\u003c\/td\u003e\n\u003ctd\u003e±0.25% of rated speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C – 70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e35.5 × 20.0 × 19.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eCore Functions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIsochronous speed control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDroop load sharing for parallel generator operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFast transient response for load rejection protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFuel and throttle actuator positioning control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used for parallel generator operation?\u003c\/strong\u003e\u003cbr\u003eYes. Droop control settings allow load sharing between multiple generator sets on a common electrical bus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat actuators are compatible?\u003c\/strong\u003e\u003cbr\u003eIt supports most standard Woodward proportional actuators using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePWM or analog current output signals\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746765025532,"sku":"8400-016","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8400-0161.jpg?v=1772090728"},{"product_id":"woodward-8405-809-electric-valve-actuator","title":"Woodward 8405-809 Electric Valve Actuator","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8405-809\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProAct 75 electric actuator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by Woodward Inc. for high-precision valve and linkage control in industrial turbine and engine systems.\u003c\/p\u003e\n\u003cp\u003eThis all-electric actuator replaces pneumatic or hydraulic actuation with a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebrushless DC motor-driven mechanism\u003c\/strong\u003e, providing faster response, higher positioning accuracy, and reduced maintenance requirements. It is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine bypass systems, engine governing, and critical process valve control\u003c\/strong\u003e, especially where high vibration and temperature exposure are expected.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8405-809\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eProAct 75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Torque\u003c\/td\u003e\n\u003ctd\u003e75 lb-ft (102 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStroke Range\u003c\/td\u003e\n\u003ctd\u003e4 – 6 inches (102 – 152 mm) adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActuation Speed\u003c\/td\u003e\n\u003ctd\u003e2 inches\/sec (51 mm\/sec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Type\u003c\/td\u003e\n\u003ctd\u003eBrushless DC with integrated feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 4 \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Verticals\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation turbine control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas flow and wellhead automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical plant process valve regulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSteam bypass and feedwater control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this actuator replace hydraulic actuators?\u003c\/strong\u003e\u003cbr\u003eYes. It is commonly used in electric conversion projects, providing comparable force without hydraulic fluid maintenance or leakage risks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the stroke length adjustable?\u003c\/strong\u003e\u003cbr\u003eYes. Stroke can be field-configured between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4 and 6 inches\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edepending on valve or fuel rack travel requirements.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746768040188,"sku":"8405-809","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8405-809.jpg?v=1772090728"},{"product_id":"overspeed-protection-module-woodward-9907-147","title":"Overspeed Protection Module Woodward 9907-147","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9907-147\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a safety protection module from Woodward Inc.’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProTech 203\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esafety system. It is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoverspeed protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof turbines, engines, and other rotating machinery.\u003c\/p\u003e\n\u003cp\u003eThe module continuously monitors\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emagnetic pickup (MPU) speed signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand triggers emergency shutdown actions when overspeed or abnormal speed conditions are detected. Operating independently from the main governor control, it provides an additional layer of safety protection for high-inertia rotating equipment.\u003c\/p\u003e\n\u003cp\u003eThe ProTech 203 architecture supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etriple-redundant logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econfigurations, enabling rapid protection response times typically under\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e40 ms\u003c\/strong\u003e, which is critical for preventing mechanical failure during sudden load rejection events.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9907-147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eProTech 203 Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e18 – 32 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Input\u003c\/td\u003e\n\u003ctd\u003ePassive or active MPU sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e1 Hz – 25 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Output\u003c\/td\u003e\n\u003ctd\u003eFailsafe trip relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 40 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C – 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eMachinery Protection Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2oo3 voting safety architecture support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMPU signal monitoring with noise filtering\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoss-of-speed detection with configurable alarm or trip action\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDirect interface to emergency trip valves and fuel shutoff systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it work with any magnetic pickup?\u003c\/strong\u003e\u003cbr\u003eYes, most MPU sensors are supported if they provide at least\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1.0 Vrms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat minimum monitored speed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if speed signal is lost?\u003c\/strong\u003e\u003cbr\u003eThe module can be configured to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ealarm or initiate a trip\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edepending on plant safety requirements.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746768072956,"sku":"9907-147","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-147.jpg?v=1772094772"},{"product_id":"woodward-9905-463-digital-speed-control-module","title":"Woodward 9905-463 Digital Speed Control Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e9905-463\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a digital turbine governor from Woodward Inc.’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e505 series\u003c\/strong\u003e. It is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esteam turbine speed control, admission control, and protection functions\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial power generation systems.\u003c\/p\u003e\n\u003cp\u003eUsing advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePID control algorithms\u003c\/strong\u003e, the module maintains stable turbine operation under varying load conditions, helping reduce mechanical stress and improve steam efficiency. The controller supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandalone speed control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eload-sharing operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor multi-generator power systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9905-463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eSteam turbine digital speed governor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e18 – 32 VDC (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Output\u003c\/td\u003e\n\u003ctd\u003e0–10 VDC or 4–20 mA configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Drive Capability\u003c\/td\u003e\n\u003ctd\u003e0–200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit high-speed digital controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eModbus RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Logic\u003c\/td\u003e\n\u003ctd\u003eOverspeed, underspeed, and trip protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eProtection \u0026amp; Control Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndependent overspeed shutdown protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLoad sharing via droop or isochronous control modes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports grid-parallel turbine operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time safety monitoring independent of main control loop\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used for gas engines?\u003c\/strong\u003e\u003cbr\u003eYes, but only in compatible high-inertia engine systems requiring 0–200 mA actuator signals and proper firmware configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow is programming performed?\u003c\/strong\u003e\u003cbr\u003eThe front-panel display and keypad allow on-site configuration of PID parameters, setpoints, and alarm limits without external programming tools for basic setup.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746768105724,"sku":"9905-463","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9905-463.jpg?v=1772090728"},{"product_id":"8440-2150-circuit-breaker-controller-woodward","title":"8440-2150 Circuit Breaker Controller Woodward","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8440-2150\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an LS-5 V2 series synchronization and protection controller from Woodward Inc.. It is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egenerator and utility breaker synchronization\u003c\/strong\u003e, supporting seamless power source transitions and grid protection in critical energy systems.\u003c\/p\u003e\n\u003cp\u003eThe controller uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLogicsManager\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etechnology to enable customizable Boolean control sequences, allowing site-specific synchronization and protection logic without additional external hardware.\u003c\/p\u003e\n\u003cp\u003eIt also provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTrue RMS sensing\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor accurate electrical monitoring and can coordinate multiple LS-5 controllers in complex power distribution networks.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8440-2150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003eLS-5 V2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Power Input\u003c\/td\u003e\n\u003ctd\u003e8 – 40 Vdc (12\/24 Vdc nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Capability\u003c\/td\u003e\n\u003ctd\u003eUp to 1.25 × Vrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eCAN + RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Configuration\u003c\/td\u003e\n\u003ctd\u003eProgrammable discrete I\/O logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensing Technology\u003c\/td\u003e\n\u003ctd\u003eTrue RMS voltage and frequency monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Modes\u003c\/td\u003e\n\u003ctd\u003eAutomatic \/ Manual \/ Stand-alone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eMetal enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail or flush mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFast synchronization response reduces breaker mechanical wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports up to 32 bus segments in distributed power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for microgrids, hospitals, and data center backup power systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides secure mains decoupling during grid instability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between LS-5 V2 and original LS-5?\u003c\/strong\u003e\u003cbr\u003eThe V2 version offers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efaster processing\u003c\/strong\u003e, enhanced LogicsManager flexibility, and improved communication stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate on both 12V and 24V systems?\u003c\/strong\u003e\u003cbr\u003eYes. The wide input range (8–40 Vdc) allows stable operation across typical industrial battery systems.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":48746768204028,"sku":"8440-2150","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8440-2150.jpg?v=1772094524"}],"url":"https:\/\/www.electronicplc.com\/collections\/woodward.oembed?page=5","provider":"Electronic PLC","version":"1.0","type":"link"}