{"title":"Yokogawa CPU Module","description":"\u003cp\u003eThe CPU module is the intelligence behind the Yokogawa Field Control Station (FCS). Our inventory focuses on the high-performance processor modules required for real-time control and logic execution in CENTUM platforms. This includes various generations of controller cards, such as the CP451, CP461, and the more modern C300-series equivalents. These modules are critical for maintaining the redundancy and fast cycle times required by complex process loops. Every CPU we provide is verified to meet the technical demands of industrial logic processing, ensuring your plant’s control layer remains responsive and reliable.\u003c\/p\u003e","products":[{"product_id":"cp451-10-processor-module-yokogawa","title":"CP451-10 Processor Module Yokogawa","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance processor module serving as the central computational unit for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eField Control Stations (FCS). This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-bit controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis engineered to execute complex regulatory control, sequence logic, and high-speed data acquisition.\u003c\/p\u003e\n\u003cp\u003eRenowned for its reliability in mission-critical environments, the CP451-10 manages communication between the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP or Vnet control network\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand various I\/O subsystems, ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estable automation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic response times\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP451-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEquipment Type\u003c\/td\u003e\n\u003ctd\u003eMain Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Speed\u003c\/td\u003e\n\u003ctd\u003e400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB (Standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Compatibility\u003c\/td\u003e\n\u003ctd\u003eAFV10S \/ AFV10D Control Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Logic and Scalability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary intelligence unit\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the Field Control Station. It enables seamless communication with distributed I\/O modules via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eESB bus or ER bus\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIn a redundant configuration:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTwo modules operate in parallel with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esynchronized memory\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe system supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003einstantaneous, bumpless transfer\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eupon failure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous process operation is maintained without disruption\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis makes the CP451-10 highly suitable for industries such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erefining, petrochemicals, and power generation\u003c\/strong\u003e, where uptime is critical.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the CP451-10 differ from the newer CP451-11?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an earlier revision. While similar in control functionality, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically incorporates\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eupdated internal components\u003c\/strong\u003e, improved lifecycle support, and compatibility with newer firmware versions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the recommended maintenance cycle for this processor?\u003c\/strong\u003e\u003cbr\u003eA: The CP451-10 is designed for long-term continuous operation. Routine maintenance involves monitoring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estatus LEDs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand system diagnostics via the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHIS (Human Interface Station)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto detect\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eECC memory alerts\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor environmental stress conditions.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746717970684,"sku":"CP451-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP451-10_S2.jpg?v=1773645566"},{"product_id":"yokogawa-cp461-processor-module","title":"Yokogawa CP461 Processor Module","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability central processing module engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa Field Control Units\u003c\/strong\u003e, specifically the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV400\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. Serving as the primary logic execution engine, this module is designed to manage\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex control algorithms\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed data communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe CP461 is the functional successor to the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-10\u003c\/strong\u003e, offering a modernized hardware platform while maintaining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efull backward compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith existing Field Control Station backplanes.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Series\u003c\/td\u003e\n\u003ctd\u003eCP461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Compatibility\u003c\/td\u003e\n\u003ctd\u003eAFV300 \/ AFV400 Controller Racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLegacy Support\u003c\/td\u003e\n\u003ctd\u003eReplacement for CP461-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eStandard type (Suffix Code 5), non-explosion proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eBasic type (Suffix Code 0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 non-standard I\/O modules per node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 cm × 5.1 cm × 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Redundancy and Reliability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere continuous operation is essential. In a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant configuration\u003c\/strong\u003e, two modules operate in parallel, with the secondary unit maintaining a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emirrored copy of memory and control logic\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIn the event of a failure:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThe system performs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eseamless switchover\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo interruption to control signals occurs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess stability is maintained\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis level of robustness makes the CP461 ideal for industries such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil \u0026amp; gas, chemical processing, and power generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperating within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystem.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CP461 compatible with Vnet\/IP communication?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when installed in an appropriate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV-series control unit\u003c\/strong\u003e, the CP461 interfaces with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa Vnet\/IP networks\u003c\/strong\u003e, ensuring high-speed and synchronized data exchange.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I mix a CP461 with an older CP461-10 in a redundant pair?\u003c\/strong\u003e\u003cbr\u003eA: While the CP461 is designed as a replacement for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-10\u003c\/strong\u003e, it is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erecommended to use identical modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein redundant configurations to ensure optimal synchronization and system stability.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746718036220,"sku":"CP461","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-502.jpg?v=1773730450"},{"product_id":"processor-module-yokogawa-cp461-50","title":"Processor Module Yokogawa CP461-50","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance central processing unit specifically engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa Field Control Units\u003c\/strong\u003e, including the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV300\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV400\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. Designed as a direct technical replacement for the legacy\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-10\u003c\/strong\u003e, this module delivers the computational power required for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time process control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments.\u003c\/p\u003e\n\u003cp\u003eIt is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability architectures\u003c\/strong\u003e, supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhere two CP461-50 units operate in parallel to ensure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ezero-downtime\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eduring hardware failovers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP461-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLegacy Compatibility\u003c\/td\u003e\n\u003ctd\u003eDirect replacement for CP461-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Application\u003c\/td\u003e\n\u003ctd\u003eAFV300 \/ AFV400 Field Control Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eStandard (Non-Explosion Protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Mode\u003c\/td\u003e\n\u003ctd\u003eSingle or dual-redundant configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 non-standard I\/O modules per node\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 cm × 5.1 cm × 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFunctional Features and Performance\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecore processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e. It executes complex control logic, manages communication with distributed I\/O modules, and interfaces with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP control network\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBy deploying the CP461-50, operators benefit from:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced system reliability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough redundancy support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLong-term lifecycle compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin CENTUM VP systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable real-time performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor critical process loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBuilt with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial-grade components\u003c\/strong\u003e, the module is designed for continuous operation in controlled cabinet environments, ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecise timing and synchronization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross the control system.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CP461-50 hot-swappable in a redundant setup?\u003c\/strong\u003e\u003cbr\u003eA: Yes, in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant configuration\u003c\/strong\u003e, one CP461-50 module can be replaced while the paired unit remains active, allowing uninterrupted process operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the key differences between the CP461-50 and the older CP461-10?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a modernized version offering improved\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomponent longevity and long-term support\u003c\/strong\u003e, while maintaining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efull backward compatibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith existing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAFV300\/AFV400 backplanes\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746718691580,"sku":"CP461-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-502.jpg?v=1773730450"},{"product_id":"processor-unit-yokogawa-cp451-11","title":"Processor Unit Yokogawa CP451-11","description":"\u003ch3\u003eTechnical Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core processing engine for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control systems. This 32-bit module is engineered to handle complex logic execution and real-time data processing for large-scale industrial automation. As a critical component of the CP451 series, the CP451-11 ensures seamless integration between control station software and field instrumentation, maintaining high-speed computational performance and system-wide synchronization.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003e32-bit High-Performance Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Speed\u003c\/td\u003e\n\u003ctd\u003e400 MHz Clock Rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Capacity\u003c\/td\u003e\n\u003ctd\u003e128 MB Standard (Expandable up to 512 MB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Connectivity\u003c\/td\u003e\n\u003ctd\u003e32 Serial Ports for peripheral integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParallel Connectivity\u003c\/td\u003e\n\u003ctd\u003e16 Parallel Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated Analog Interface\u003c\/td\u003e\n\u003ctd\u003e8 Analog Inputs \/ 8 Analog Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Limits\u003c\/td\u003e\n\u003ctd\u003e-20°C to 60°C (-4°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSystem Performance and Scalability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for rugged industrial environments where process uptime is non-negotiable. Its architecture supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodular expansion\u003c\/strong\u003e, allowing for memory upgrades to meet increasing data demands in evolving DCS networks. The high channel density of integrated I\/O ports reduces reliance on external interface modules, simplifying cabinet design and maintenance. This processor is particularly effective in applications requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edense serial communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprecise analog control loops\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which control systems support the CP451-11?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis natively compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM CS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitectures, functioning as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the memory on the CP451-11 user-upgradeable?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the base memory of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e128 MB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be expanded to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e512 MB\u003c\/strong\u003e, enabling support for more complex control strategies and larger process databases.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746718789884,"sku":"CP451-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP451-11.jpg?v=1773731798"},{"product_id":"yokogawa-cp701-s1-processor-module","title":"Yokogawa CP701 S1 Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP701 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CP701 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance field control processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor Yokogawa’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM series distributed control systems (DCS)\u003c\/strong\u003e. It delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic control logic execution, real-time data acquisition\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erobust plant-wide communication\u003c\/strong\u003e, ensuring high availability in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical industrial environments\u003c\/strong\u003e. Its rugged design withstands the thermal and electrical stresses of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eenergy generation, petrochemical, and large-scale chemical processing\u003c\/strong\u003e, while maintaining precise\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess synchronization\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand system reliability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eCP701 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eField Control Processor (FCP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM Series DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Focus\u003c\/td\u003e\n\u003ctd\u003eReal-time logic execution, loop control, data throughput\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegration\u003c\/td\u003e\n\u003ctd\u003eOptimized for Field Control Station (FCS) base unit mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Status\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade, high-reliability automation component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance and Reliability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP701 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-uptime applications\u003c\/strong\u003e, reducing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elatency in critical control loops\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata integrity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom field instrumentation to operator consoles. It supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ediscrete sequence management\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous analog regulation\u003c\/strong\u003e, providing deterministic performance for complex automation processes. Its modular architecture enables\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estreamlined maintenance, rapid system scaling\u003c\/strong\u003e, and robust reliability in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CP701 S1 compatible with both CENTUM VP and older CENTUM platforms?\u003c\/strong\u003e\u003cbr\u003eA: The CP701 S1 is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especific CENTUM series architectures\u003c\/strong\u003e. Verify your FCS base unit hardware revision and firmware version for full compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support redundant processor pairings?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant control pairs\u003c\/strong\u003e, ensuring zero-failover impact during maintenance or unexpected faults.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746718920956,"sku":"CP701 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP701_S12.jpg?v=1773645566"},{"product_id":"cp345-s1-processor-module-yokogawa","title":"CP345 S1 Processor Module Yokogawa","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP345 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM Series DCS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments. Serving as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomputational core\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Stations (FCS)\u003c\/strong\u003e, it delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic logic execution, high-speed data processing, and reliable communication management\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEngineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical applications\u003c\/strong\u003e—including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eenergy production, petrochemical refining, and continuous chemical processing\u003c\/strong\u003e—the CP345 S1 ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoperational stability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaximizes system uptime\u003c\/strong\u003e. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact, rugged architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows dense installation in control cabinets, ideal for both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enew system deployments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodernization of existing DCS infrastructures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eCP345 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e6.1 cm × 25.0 cm × 26.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance and Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP345 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessing power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex control strategies\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-loop automation\u003c\/strong\u003e. By efficiently managing the interface between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote field instruments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral operator station\u003c\/strong\u003e, it maintains\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess integrity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand minimizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elatency in safety-critical loops\u003c\/strong\u003e. Its durable design simplifies maintenance, allowing seamless integration into existing FCS racks while supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eplant-wide asset management\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CP345 S1 compatible with existing CENTUM system firmware?\u003c\/strong\u003e\u003cbr\u003eA: Yes. It is intended for specific CENTUM series architectures. Verify your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCS firmware version\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand base unit compatibility for seamless operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support redundant configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The CP345 S1 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability dual-redundant processor setups\u003c\/strong\u003e, preventing system downtime in continuous manufacturing processes.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746719183100,"sku":"CP345 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP345_S1.jpg?v=1773650029"},{"product_id":"yokogawa-scp461-11-s1-processor-module","title":"Yokogawa SCP461-11 S1 Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-11 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM Series DCS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments. It serves as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomputational engine\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanaging\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time control logic\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edata communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween field instrumentation and the primary control network.\u003c\/p\u003e\n\u003cp\u003eEngineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed process synchronization\u003c\/strong\u003e, this module is critical for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elarge-scale industrial operations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein sectors such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical processing, energy generation, and continuous manufacturing\u003c\/strong\u003e. Its compact, modular form factor ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh availability\u003c\/strong\u003e, reliable performance, and straightforward integration into standard\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecabinet configurations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eSCP461-11 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM Series DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Focus\u003c\/td\u003e\n\u003ctd\u003eReal-time logic execution and deterministic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eCompatible with FCS base units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Status\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade, high-reliability hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeployment and Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-11 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edemanding industrial environments\u003c\/strong\u003e, providing stable operation while managing distributed control loops. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow-latency architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports stringent safety-instrumented system requirements and complex automated process control. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodular design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates rapid deployment or upgrades, allowing maintenance engineers to maximize control efficiency with minimal downtime during hardware refreshes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the SCP461-11 S1 designed for redundant control pairs?\u003c\/strong\u003e\u003cbr\u003eA: Yes. This processor supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability dual-redundant configurations\u003c\/strong\u003e, enabling seamless synchronization and failover within CENTUM systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use this module to replace a legacy processor?\u003c\/strong\u003e\u003cbr\u003eA: The SCP461-11 S1 is intended for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especific CENTUM environments\u003c\/strong\u003e. Verify your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCS base unit firmware and hardware revision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure compatibility before installation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746719379708,"sku":"SCP461-11 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP461-11_S1.jpg?v=1773645565"},{"product_id":"yokogawa-cp451-10-s2-processor-module","title":"Yokogawa CP451-10 S2 Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-10 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for demanding industrial automation environments. As a key component in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM Series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitectures, it executes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex logic, manages high-speed control loops\u003c\/strong\u003e, and delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor mission-critical applications.\u003c\/p\u003e\n\u003cp\u003eIts robust design is ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability industries\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation, chemical processing, and large-scale manufacturing\u003c\/strong\u003e, where precise control and system reliability are essential for maintaining continuous operation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eCP451-10 S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eAdvanced Industrial Automation \u0026amp; CENTUM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 cm × 5.1 cm × 20.3 cm (6.0 × 2.0 × 8.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance and Reliability\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-10 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eminimal downtime and high-speed computation\u003c\/strong\u003e. It can manage multiple control loops simultaneously, reducing latency in critical control and safety operations. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact, modular form factor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows for high-density mounting in standard control cabinets, simplifying Field Control Station (FCS) layouts while ensuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elong-term durability in rugged industrial conditions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CP451-10 S2 compatible with existing CENTUM DCS hardware?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module is designed for integration into standard Yokogawa control platforms. Verify your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecabinet wiring and firmware\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure full compatibility with existing FCS base units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this processor support hot-swapping or redundancy?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-10 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant processor configurations\u003c\/strong\u003e, enabling seamless failover in high-uptime environments where the control architecture accommodates dual-processor synchronization.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746719412476,"sku":"CP451-10 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP451-10_S2.jpg?v=1773645566"},{"product_id":"cp401-10-processor-module-yokogawa","title":"CP401-10 Processor Module Yokogawa","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance processor module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM Distributed Control System\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eseries. It acts as a core processing unit responsible for executing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex control logic, high-speed calculations, and real-time data handling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin distributed automation environments.\u003c\/p\u003e\n\u003cp\u003eEngineered for stability and continuous-duty operation, the CP401-10 ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereliable communication between field instrumentation and the central control network\u003c\/strong\u003e. Its compact design supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density installation in industrial control cabinets\u003c\/strong\u003e, making it well suited for facilities that require robust and scalable process automation systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eCP401-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm × 20.3 cm × 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeployment and Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a fundamental building block for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eplant-wide distributed control strategies\u003c\/strong\u003e, coordinating communication and logic execution across multiple control loops. Designed for the rigorous requirements of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical processing plants, petroleum refineries, and power generation facilities\u003c\/strong\u003e, the module delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic and stable performance\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor critical automation tasks.\u003c\/p\u003e\n\u003cp\u003eIts architecture emphasizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem longevity and maintainability\u003c\/strong\u003e, allowing engineers to integrate the processor seamlessly into existing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments while minimizing operational disruption during upgrades or replacements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CP401-10 compatible with existing CENTUM systems?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for specific CENTUM series platforms. It is recommended to verify your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esystem firmware revision and FCS base unit model\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure full compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used in a redundant processor setup?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability configurations\u003c\/strong\u003e, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant processor deployments\u003c\/strong\u003e, ensuring that control operations continue uninterrupted in the event of a processor fault.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746719543548,"sku":"CP401-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP401-10.jpg?v=1773645565"},{"product_id":"yokogawa-nfcp100-s00-cpu-module-centum-vp-processor","title":"Yokogawa NFCP100-S00 CPU Module CENTUM VP Processor","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFCP100-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance processor module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform. It functions as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary control engine within a Field Control Station (FCS)\u003c\/strong\u003e, responsible for executing control logic, managing loop control, and processing real-time operational data.\u003c\/p\u003e\n\u003cp\u003eDesigned with a focus on\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estability, deterministic performance, and high availability\u003c\/strong\u003e, the NFCP100-S00 ensures reliable operation in complex industrial automation environments. Its compact form factor allows efficient installation within standard control cabinets, making it well suited for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous-duty applications where system uptime is critical\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eNFCP100-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.6 cm × 12.7 cm × 12.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Status\u003c\/td\u003e\n\u003ctd\u003eReliable high-speed processing for FCS base units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeployment and Integration\u003c\/h3\u003e\n\u003cp\u003eThe NFCP100-S00 plays a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral role in plant-wide automation strategies\u003c\/strong\u003e, coordinating communication between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield instrumentation and supervisory control networks\u003c\/strong\u003e. Its architecture is optimized for the demanding requirements of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodern manufacturing facilities, petrochemical refineries, and power generation infrastructure\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEngineered for straightforward installation, the module allows maintenance engineers to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereplace or upgrade processing hardware within an existing FCS architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith minimal disruption to ongoing operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the NFCP100-S00 compatible with legacy Yokogawa CENTUM systems?\u003c\/strong\u003e\u003cbr\u003eA: The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFCP100-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed primarily for the CENTUM VP platform. It is recommended to verify your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCS firmware version and cabinet hardware configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure full compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this unit support redundant processor configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant processor configurations\u003c\/strong\u003e, allowing deployment in dual-processor setups to meet the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability and safety requirements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypical of critical distributed control system environments.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746719674620,"sku":"NFCP100-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NFCP100-S00.jpg?v=1773645566"},{"product_id":"yokogawa-cp333d-processor-module","title":"Yokogawa CP333D Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP333D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance computational engine within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM CS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003earchitectures. Built on a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-bit RISC processor architecture\u003c\/strong\u003e, this module delivers the deterministic processing speed and reliability required for mission-critical industrial automation.\u003c\/p\u003e\n\u003cp\u003eThe CP333D is engineered to execute\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex control logic, high-speed data acquisition, and network communication\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eacross distributed control nodes. With optimized memory capacity and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual Ethernet connectivity\u003c\/strong\u003e, the module ensures seamless integration and responsive operation within demanding environments such as manufacturing plants, refineries, and power generation facilities.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP333D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing Frequency\u003c\/td\u003e\n\u003ctd\u003e400 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 256 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Connectivity\u003c\/td\u003e\n\u003ctd\u003eDual Ethernet Ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS and CENTUM VP Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Support\u003c\/td\u003e\n\u003ctd\u003eUp to 16 Slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.3 cm × 5.1 cm × 25.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance Overview\u003c\/h3\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability distributed control systems\u003c\/strong\u003e, the CP333D manages communication between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield instrumentation and the centralized control platform\u003c\/strong\u003e. Its architecture minimizes latency in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereal-time control loops\u003c\/strong\u003e, making it particularly suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erefineries, chemical processing plants, and power generation facilities\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat depend on stable and deterministic automation systems.\u003c\/p\u003e\n\u003cp\u003eThe module is also engineered to withstand variable industrial thermal conditions, ensuring reliable performance in both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtrolled control-room environments and more demanding operational areas\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this processor compatible with both CENTUM CS and CENTUM VP systems?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP333D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis specifically designed for interoperability with both CENTUM CS and CENTUM VP distributed control platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support hot-swapping or redundant configuration?\u003c\/strong\u003e\u003cbr\u003eA: The module is designed for the rigorous requirements of DCS architectures. For redundancy support and maintenance procedures, consult the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Station (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edocumentation corresponding to your system revision.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746720493820,"sku":"CP333D","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP333D1.jpg?v=1773645565"},{"product_id":"yokogawa-cp133e-64-s3-processor-module","title":"Yokogawa CP133E-64 S3 Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP133E-64 S3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core processing engine within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control system architecture. This module is engineered to handle complex control logic execution and seamless data exchange between field instrumentation and the primary control network. By leveraging advanced\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP communication protocols\u003c\/strong\u003e, the module ensures robust, real-time data integrity for mission-critical industrial processes. Designed for high availability, this unit fully supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant configurations\u003c\/strong\u003e, making it an essential component for sustaining continuous plant operations.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eCP133E-64 S3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Protocol\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eFull support for dual-redundant deployment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eCompatible with Field Control Station (FCS) base units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Status\u003c\/td\u003e\n\u003ctd\u003eFactory new, original hardware\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeployment and Integration\u003c\/h3\u003e\n\u003cp\u003eThis processor module is utilized in large-scale production facilities such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erefineries, chemical plants, and power generation stations\u003c\/strong\u003e. It is specifically designed to fit into standard Yokogawa base units, facilitating rapid deployment in environments requiring high-speed computational power and stable, deterministic control. Engineers should ensure that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ebase unit firmware is compatible with the S3 revision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain optimal system performance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module compatible with existing CENTUM VP systems using older processors?\u003c\/strong\u003e\u003cbr\u003eA: The CP133E-64 S3 is designed for specific CENTUM VP environments. We recommend verifying your existing hardware revision and FCS base unit specifications to ensure seamless integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this unit support hot-swapping in a redundant pair?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when configured in a dual-redundant architecture, the system is designed to allow for module maintenance without disrupting primary control operations.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746720657660,"sku":"CP133E-64 S3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP133E-64_S31.jpg?v=1773645565"},{"product_id":"cp334d-s3-yokogawa-centum-vp-processor-module","title":"CP334D S3 Yokogawa CENTUM VP Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP334D S3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance central processor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control Systems (DCS)\u003c\/strong\u003e. It serves as the primary control engine for a control node, managing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex process loops, sequence logic, and supervisory data acquisition\u003c\/strong\u003e. Built on a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e32-bit RISC architecture\u003c\/strong\u003e, the module provides deterministic, high-speed processing for demanding industrial environments, including water treatment, chemical plants, and petrochemical refineries. Its design supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault-tolerant operation and scalable system architecture\u003c\/strong\u003e, enabling precise control across multiple I\/O points.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Identification\u003c\/td\u003e\n\u003ctd\u003eCP334D S3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Architecture\u003c\/td\u003e\n\u003ctd\u003e32-bit RISC processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Configuration\u003c\/td\u003e\n\u003ctd\u003e2 MB RAM \/ 2 MB Flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 256 physical\/logical I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-232, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003eCompatible with CENTUM VP DCS platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Tolerance\u003c\/td\u003e\n\u003ctd\u003eHigh-availability control node configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eField Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP334D S3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis used in industrial automation where reliable, high-speed control is required:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProcess Control\u003c\/strong\u003e: Managing PID loops for flow, pressure, and temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupervisory Control\u003c\/strong\u003e: Bridging SCADA systems with field instrumentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Acquisition\u003c\/strong\u003e: Aggregating data from remote terminal units (RTUs) or smart sensors via integrated communication ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the 256 I\/O point limit affect system design?\u003c\/strong\u003e\u003cbr\u003eThis limit represents the number of I\/O points a single CP334D S3 module can manage within its control node. For larger systems, additional nodes or processor modules can be added to distribute the control load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CP334D S3 suitable for mission-critical safety applications?\u003c\/strong\u003e\u003cbr\u003eNo. While highly reliable for standard DCS operations, mission-critical safety loops require\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety-rated hardware\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eplatform, which meets specific SIL requirements. Always verify the required SIL for your application.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746720723196,"sku":"CP334D S3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP334D_S3.jpg?v=1773645565"},{"product_id":"yokogawa-cp451-50-industrial-processor-module","title":"Yokogawa CP451-50 Industrial Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral processor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa distributed control systems (DCS)\u003c\/strong\u003e, designed to handle high-speed logic execution, regulatory control, and real-time process data management. Serving as the intelligence hub for its control node, it ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic and precise loop control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor temperature, pressure, motion, and other process variables. Its compact form factor allows\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density integration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin Yokogawa control racks, making it ideal for both new installations and upgrades of existing systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Identification\u003c\/td\u003e\n\u003ctd\u003eCP451-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCentral Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Focus\u003c\/td\u003e\n\u003ctd\u003eSequence control, regulatory loop management, process data processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm × 20.3 cm × 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Environment\u003c\/td\u003e\n\u003ctd\u003e0°C to 55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eField Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP451-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis suited for continuous, high-uptime industrial control:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing Automation\u003c\/strong\u003e: Logic control for assembly lines and robotics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical Processing\u003c\/strong\u003e: Sequence logic and safety interlocks for fluid handling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation\u003c\/strong\u003e: Coordination of auxiliary plant equipment and operational monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Handling\u003c\/strong\u003e: Fast, reliable control for high-speed sorting and distribution systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CP451-50 compatible with all Yokogawa control software?\u003c\/strong\u003e\u003cbr\u003eCompatibility depends on the firmware version of your existing rack and the specific control software (e.g., CENTUM VP or ProSafe-RS). Always verify against the system’s hardware compatibility matrix before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be replaced while the system is powered?\u003c\/strong\u003e\u003cbr\u003eSwapping the CP451-50 generally requires shutting down the node. If the system is configured with dual-redundant CPUs, follow the specific hot-swap procedures outlined in the maintenance manual to avoid process disruption.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746720788732,"sku":"CP451-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP451-501.jpg?v=1773645565"},{"product_id":"scp451-11-processor-module-yokogawa","title":"SCP451-11 Processor Module Yokogawa","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP451-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-performance central processor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for integration into\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa distributed control systems (DCS)\u003c\/strong\u003e. Acting as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecore computation engine\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eof its control node, it executes complex logic loops, manages real-time data processing, and coordinates communication between field devices and the main control network. Engineered in Japan, it delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic, high-speed control\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith long-term reliability for mission-critical industrial applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Identification\u003c\/td\u003e\n\u003ctd\u003eSCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCentral Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm × 20.3 cm × 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Focus\u003c\/td\u003e\n\u003ctd\u003eHigh-speed sequence and regulatory control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Integration\u003c\/td\u003e\n\u003ctd\u003eCompatible with Yokogawa control racks and backplanes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Environment\u003c\/td\u003e\n\u003ctd\u003eStandard industrial control room conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eField Applications\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP451-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-speed localized process logic\u003c\/strong\u003e, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated assembly line control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical process regulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower distribution and monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBy processing intensive calculations locally, it\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereduces communication load on the main processor\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esub-millisecond stability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor critical control loops such as motor speed regulation, flow control, and pressure regulation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SCP451-11 compatible with older Yokogawa control software?\u003c\/strong\u003e\u003cbr\u003eCompatibility depends on the control rack’s firmware version and system revision. Always verify against the official\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompatibility matrix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebefore replacing modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a battery backup for memory retention?\u003c\/strong\u003e\u003cbr\u003eSome versions use\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enon-volatile memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efield-replaceable battery\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto retain logic programs during power interruptions. Refer to the system maintenance manual for battery replacement schedules and procedures.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746721116412,"sku":"SCP451-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP451-11_61778cb4-4133-423f-a630-f314ea434be2.jpg?v=1773645565"},{"product_id":"yokogawa-scp451-51-central-processor-module","title":"Yokogawa SCP451-51 Central Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SCP451-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-availability\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral processor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered specifically for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS Safety Instrumented System (SIS)\u003c\/strong\u003e. As a core component of safety-critical automation, this processor ensures deterministic logic execution and high-speed communication required for emergency shutdown and fire and gas detection applications. Its robust architecture is built to support the stringent demands of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3-rated environments\u003c\/strong\u003e, providing the reliability necessary for protecting personnel and equipment in hazardous industrial processes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP451-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilitates seamless integration into safety controller racks, maintaining integrity through rigorous diagnostic self-checks and optimized scan cycles.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCP451-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS Safety Instrumented Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed safety-rated CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated safety bus connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated for industrial environmental extremes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliability Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated self-diagnostics and fail-safe monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP451-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-density safety logic management. By minimizing loop latency and providing advanced error-detection capabilities, the module ensures that safety functions are executed reliably without compromising plant throughput. Its modular construction simplifies system maintenance, allowing for rapid replacement in the event of hardware anomalies while ensuring that the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esafety instrumented function (SIF)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis restored with minimal downtime.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Is the SCP451-51 compatible with earlier versions of the ProSafe-RS system?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Compatibility is firmware and hardware revision dependent. Please verify the compatibility matrix of your current\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtroller rack before replacing or upgrading modules.\u003c\/p\u003e\n\u003ch4\u003eQ: Does this module support redundant controller configurations?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP451-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to operate in redundant pairs within a safety controller chassis to ensure continuous operation in the event of a primary module fault.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746737336572,"sku":"SCP451-51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP451-51.jpg?v=1773039116"},{"product_id":"cp330d-s3-yokogawa-industrial-plc-processor-module","title":"CP330D S3 Yokogawa Industrial PLC Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CP333D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a robust and highly reliable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePLC processor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for mission-critical industrial control environments. Engineered to serve as the central computational engine for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa control systems\u003c\/strong\u003e, it handles complex logic execution, high-speed data processing, and seamless I\/O communication. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP333D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for stability in demanding applications such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil and gas processing\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewater treatment\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emanufacturing\u003c\/strong\u003e, ensuring deterministic performance and minimal latency in real-time control loops. Its modular and compact architecture allows for straightforward integration into existing control racks, providing an efficient path for system upgrades or maintenance replacements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP333D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePLC Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral logic and communication processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed industrial-grade CPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated bus connectivity for Yokogawa I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with standard 24 V DC system power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReliability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesigned for continuous operation in high-stress industrial environments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRated for standard industrial control cabinets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRack-mountable for system backplane integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP333D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocessor provides superior cycle time efficiency, allowing for the precise management of multiple control loops simultaneously. Its design prioritizes operational availability, ensuring that critical safety and process functions remain uninterrupted. Furthermore, the module includes comprehensive built-in diagnostics to assist in system health monitoring, reducing troubleshooting time and enhancing overall plant visibility.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Is the CP333D compatible with older versions of Yokogawa control software?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Compatibility depends on the specific firmware version and system generation. We recommend cross-referencing your system's current software version with the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP333D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ehardware revision before installation.\u003c\/p\u003e\n\u003ch4\u003eQ: Can this module be used in a redundant processor setup?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP333D\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to support redundant configurations within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa controller rack\u003c\/strong\u003e, enabling seamless failover to ensure maximum system uptime.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746737369340,"sku":"CP330D S3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AAI143-S00.jpg?v=1773042241"},{"product_id":"central-processor-module-yokogawa-cp461-50-s2","title":"Central Processor Module Yokogawa CP461-50 S2","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CP461-50 (S2)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance central processor module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP distributed control system (DCS)\u003c\/strong\u003e. Engineered to manage complex control strategies with high reliability, this module provides the computational power required for large-scale industrial automation. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS2 revision\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoffers optimized instruction execution and enhanced communication capabilities to ensure seamless data synchronization between controllers and field I\/O. Its rugged architecture is built to support\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24\/7 continuous operation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein mission-critical environments, providing stability and precision for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocesses.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCP461-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRevision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCentral Processor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Function\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-speed execution of control and calculation blocks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDedicated V-net\/IP integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC system supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa CP series form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Performance Benefits\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-50 S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a cornerstone of the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP architecture\u003c\/strong\u003e, designed to minimize scan times for complex control loops. Its advanced internal diagnostics allow for early detection of module health issues, ensuring that the control system remains predictable and secure. By facilitating high-density data exchange across the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eV-net\/IP network\u003c\/strong\u003e, it enables operators to manage plant-wide operations with high visibility and minimal latency.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What does the \"S2\" designation signify in the CP461-50 model?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: The \"S2\" indicates an updated hardware revision of the module, typically featuring improved reliability, optimized components, or refined firmware compatibility compared to the original release.\u003c\/p\u003e\n\u003ch4\u003eQ: Can the CP461-50 be used in a redundant control configuration?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, this processor is designed to support dual-redundant setups, allowing for automatic, bumpless switch-over between modules in the event of a primary processor failure.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746737402108,"sku":"CP461-50 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-50_S2.jpg?v=1773040915"},{"product_id":"scp451-53-yokogawa-central-processor-module","title":"SCP451-53  Yokogawa Central Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SCP451-53\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance central processor module engineered specifically for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS Safety Instrumented System (SIS)\u003c\/strong\u003e. This critical component is designed to meet stringent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 safety requirements\u003c\/strong\u003e, providing the computational reliability necessary for emergency shutdown systems and fire and gas protection. By utilizing a high-efficiency\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eARM-based dual-core architecture\u003c\/strong\u003e, the SCP451-53 ensures deterministic execution of safety logic, minimizing response times during process upsets. Its robust design allows for stable operation in demanding environments, ensuring consistent safety oversight in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erefineries\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical plants\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation facilities\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCP451-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProcessor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDual-core ARM Cortex-A9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 GB DDR3 SDRAM, 8 GB NAND Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x Ethernet, 2x USB, 1x RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 mm x 120 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Advantages\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP451-53\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esimplifies safety system maintenance through its integrated diagnostic capabilities and high-speed communication interfaces. With dual-core processing, it provides a layer of redundancy that is essential for fail-safe operations. The inclusion of versatile I\/O ports allows for flexible connectivity to engineering workstations and supervisory systems, facilitating seamless status monitoring and periodic safety logic validation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Is the SCP451-53 suitable for direct process control, or only for safety functions?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: This module is specifically optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS safety systems\u003c\/strong\u003e. While it integrates with the wider plant control network, its primary application is the execution of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL-rated safety instrumented functions\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4\u003eQ: Does this processor support hot-swapping in a safety cabinet?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSafe-RS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesign allows for modular replacement to ensure that safety integrity is maintained with minimal impact on process availability during maintenance windows.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746737434876,"sku":"SCP451-53","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP401-11.jpg?v=1773039116"},{"product_id":"yokogawa-scp401-11-processor-module","title":"Yokogawa SCP401-11 Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa SCP401-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized processor module designed to serve as the computational backbone for demanding industrial control applications. Built for high-speed data processing and reliable system execution, this module is an essential component for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed control systems (DCS)\u003c\/strong\u003e. It excels in environments requiring precise, real-time logic processing and stable communication between system-level controllers and field instrumentation. Its compact and ruggedized design ensures high availability, making it suitable for mission-critical operations where reliability is non-negotiable.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSCP401-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.4 cm x 10.2 cm x 10.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa control system racks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBuild Standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-durability industrial grade\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Highlights\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP401-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for high-efficiency instruction cycles, ensuring that complex control loops and safety logic are managed with minimal latency. Designed to be a core processing node, it facilitates seamless interaction with associated I\/O modules, maintaining synchronization across the control network. Its architecture is specifically engineered to handle the thermal and physical stresses typical of industrial server rooms and field cabinets, ensuring long-term operational success.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: What is the primary role of the SCP401-11 in a control rack?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: This module functions as the central processor for executing logic and managing communications for the I\/O modules connected to the control bus.\u003c\/p\u003e\n\u003ch4\u003eQ: Does the SCP401-11 require specific firmware versions?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, as with most Yokogawa processor modules, compatibility depends on the system's current firmware. It is recommended to verify the specific revision number of your existing system before final installation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746737467644,"sku":"SCP401-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP401-11.jpg?v=1773039116"},{"product_id":"main-processor-module-yokogawa-cp401-11","title":"Main Processor Module Yokogawa CP401-11","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP401-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability processor module engineered for the CENTUM CS 3000 Distributed Control System (DCS). It functions as the primary intelligence of the Field Control Station (FCS), executing complex control logic and managing real-time communication between I\/O modules and the upper-level bus network.\u003c\/p\u003e\n\u003cp\u003eDesigned for long-term operational stability, the CP401-11 ensures continuous and deterministic process control in harsh industrial environments, minimizing logic drift and performance degradation over time.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Identification\u003c\/td\u003e\n\u003ctd\u003eCP401-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 3000 \/ CENTUM CS 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eV net \/ VL net support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e81 mm × 103 mm × 146 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Protection\u003c\/td\u003e\n\u003ctd\u003eECC (Error-Correcting Code) technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow power architecture with reduced thermal footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eFully compatible with dual-redundant FCS configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe CP401-11 is widely deployed in high-stakes industrial sectors, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eChemical manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLNG processing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePharmaceutical production plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt delivers deterministic timing performance required for advanced regulatory control, sequence management, and safety-related process execution within complex automation architectures.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Technical Inquiry\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the primary difference between the CP401-11 and earlier versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CP401-11 provides enhanced processing throughput and improved thermal management compared to legacy models. These upgrades make it a preferred replacement for aging CENTUM CS 3000 hardware, improving long-term system reliability and operational stability.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745200892,"sku":"CP401-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-E1.jpg?v=1772786353"},{"product_id":"cp345-processor-card-module-yokogawa","title":"CP345 Processor Card Module Yokogawa","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP345\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a core computational unit within the CENTUM CS 3000 Distributed Control System (DCS). This high-performance processor card is specifically engineered to execute complex control algorithms and advanced sequence control tasks for Field Control Stations (FCS).\u003c\/p\u003e\n\u003cp\u003eDesigned for maximum system availability, the CP345 delivers high-speed data processing and deterministic control performance, ensuring stable plant operations in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Identifier\u003c\/td\u003e\n\u003ctd\u003eCP345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOriginal Manufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 3000 \/ CENTUM CS 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Function\u003c\/td\u003e\n\u003ctd\u003eMain Processor Unit for Field Control Stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eV net \/ VL net compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e270 mm × 250 mm × 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMass\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Capability\u003c\/td\u003e\n\u003ctd\u003eFull dual-redundant (duplex) support\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePassive cooling for rack-mounted enclosures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe CP345 is widely deployed in heavy industrial sectors, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil and gas refining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale power generation facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWithin the control architecture, it functions as the central processing engine of the Field Control Station, interpreting field input signals, executing PID and sequence logic, and issuing output commands to maintain process safety, reliability, and operational efficiency.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CP345 be swapped while the system is live?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. When installed in a duplexed Field Control Station, the CP345 supports online replacement. The standby processor automatically assumes control responsibilities, ensuring uninterrupted operation during maintenance procedures.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745233660,"sku":"CP345","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP7012.jpg?v=1772610735"},{"product_id":"cp701-yokogawa-field-control-station-cpu","title":"CP701 Yokogawa Field Control Station CPU","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP701\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the primary central processing module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM CS 1000 Distributed Control System (DCS)\u003c\/strong\u003e. Designed as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“Basic System” model\u003c\/strong\u003e, the CP701 provides cost-effective and reliable logic execution for small to medium-scale industrial processes. It utilizes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eR4300 microprocessor architecture\u003c\/strong\u003e, which was one of the earliest CPUs integrated into Yokogawa’s control system lineup, delivering a balance between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elow power consumption\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e75 MHz internal processing speed\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eTo ensure mission-critical reliability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP701\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eError-Correction Code (ECC) memory\u003c\/strong\u003e, which automatically detects and corrects bit errors to prevent system crashes during continuous plant operation. Its modular design allows installation in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Stations (FCS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor managing I\/O processing, PID control loops, and sequence logic execution.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicroprocessor\u003c\/td\u003e\n\u003ctd\u003eR4300 MPU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Clock Speed\u003c\/td\u003e\n\u003ctd\u003e75 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Bus Clock\u003c\/td\u003e\n\u003ctd\u003e25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e8 MB (Basic System Model)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Integrity\u003c\/td\u003e\n\u003ctd\u003eECC memory error correction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing Capabilities\u003c\/td\u003e\n\u003ctd\u003eIntegrated MMU for secure data partitioning\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003eOptimized for fanless natural convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features \u0026amp; Comparison\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMemory Architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— The CP701 is fixed at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 MB memory\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eas a basic system model. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP703\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis available for applications requiring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 MB memory capacity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWrite Protection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Provides hardware-level write protection to prevent unauthorized memory writes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e— Supports dual-redundant configurations when paired with another CP701 module on a compatible baseplate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CP701 be upgraded to 16 MB of memory?\u003c\/strong\u003e\u003cbr\u003eNo. The CP701 is hardware-fixed at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 MB\u003c\/strong\u003e. For larger memory requirements, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP703 Enhanced System Model\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eshould be used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CP701 compatible with CENTUM VP?\u003c\/strong\u003e\u003cbr\u003eNo. The CP701 is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 1000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystems. For\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e, newer processors such as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461 or CP471 series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eare typically required.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745299196,"sku":"CP701","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP7011.jpg?v=1772610735"},{"product_id":"yokogawa-cp471-00-centum-vp-processor-module-unit","title":"Yokogawa CP471-00 Centum VP Processor Module Unit","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP471-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a high-performance processing engine designed specifically for the CENTUM VP distributed control system (DCS). This module is engineered to execute complex control logic and manage real-time data communication across the Field Control Station (FCS).\u003c\/p\u003e\n\u003cp\u003eIts compact footprint enables high-density installation within standard I\/O racks while maintaining low power consumption and excellent thermal stability, making it ideal for continuous industrial operation in mission-critical environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP471-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eMain Processing Unit (MPU) for Field Control Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions (W × H × D)\u003c\/td\u003e\n\u003ctd\u003e127 mm × 127 mm × 51 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Memory\u003c\/td\u003e\n\u003ctd\u003eHigh-speed ECC RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant (duplex) configuration capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eThe CP471-00 is typically deployed in large-scale industrial environments such as petrochemical refineries, power generation plants, and water treatment facilities.\u003c\/p\u003e\n\u003cp\u003eIt is responsible for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eStabilizing PID control loops\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManaging sequence and interlock control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExecuting complex real-time control algorithms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoordinating seamless communication between field instruments and HMI\/SCADA systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Technical Inquiry\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the CP471-00 support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eYes. When installed in a duplexed (redundant) Field Control Station, the module supports online replacement (hot-swapping), allowing maintenance without interrupting plant operations and ensuring zero downtime for critical processes.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745331964,"sku":"CP471-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-E1.jpg?v=1772786353"},{"product_id":"yokogawa-scp461-51-s2-processor-module","title":"Yokogawa SCP461-51-S2 Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-51-S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-integrity safety processor module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ProSafe-RS Safety Instrumented System (SIS)\u003c\/strong\u003e. As the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elogic solver\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmergency Shutdown (ESD)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFire and Gas (F\u0026amp;G)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eapplications, this module executes critical safety loops with deterministic precision. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“S2” variant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates a performance or firmware tier optimized for high-speed safety logic execution within the ProSafe-RS ecosystem.\u003c\/p\u003e\n\u003cp\u003eEngineered to meet stringent\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3 safety requirements\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhen deployed in redundant pairs, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-51-S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econtinuously performs internal diagnostics to detect and mitigate potential hardware faults. Its compact, fanless design ensures long operational life in harsh industrial environments such as offshore platforms and chemical refineries. This module acts as the central intelligence of the safety control unit, synchronizing with I\/O modules and reporting system health to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIntegrated Control and Safety System (ICSS)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eSCP461-51-S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS Safety Instrumented System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL3 capable (in redundant configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Type\u003c\/td\u003e\n\u003ctd\u003eReal-time Safety Logic Solver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant pairing supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e3.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Height\u003c\/td\u003e\n\u003ctd\u003e10.7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Depth\u003c\/td\u003e\n\u003ctd\u003e13.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExecuting Emergency Shutdown (ESD) sequences for oil and gas pipelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManaging Burner Management Systems (BMS) in thermal power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoordinating High-Pressure Protection Systems (HIPPS) in subsea installations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between S1 and S2 versions of the SCP461?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-51-S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egenerally provides enhanced memory capacity and optimized firmware support for more complex safety logic compared to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eS1 variant\u003c\/strong\u003e. Always verify software revision compatibility before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module be replaced while the safety system is active?\u003c\/strong\u003e\u003cbr\u003eYes. When used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant ProSafe-RS configurations\u003c\/strong\u003e, one\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-51-S2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule can be hot-swapped while the partner processor maintains active safety control, ensuring zero system downtime.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745430268,"sku":"SCP461-51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP461-51_S2.jpg?v=1772617265"},{"product_id":"central-processing-unit-dcs-module-cp461-10-yokogawa","title":"Central Processing Unit DCS Module CP461-10 Yokogawa","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance central processing unit specifically engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e. Acting as the primary intelligence for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Units (FCU)\u003c\/strong\u003e, this module executes high-level regulatory control and complex sequence logic. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis built for mission-critical industrial environments where deterministic processing and long-term hardware reliability are essential for plant safety and operational efficiency.\u003c\/p\u003e\n\u003cp\u003eEquipped with advanced networking capabilities, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanages seamless data exchange across the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP control bus\u003c\/strong\u003e, coordinating information between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHuman-Machine Interfaces (HMI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand distributed I\/O modules. Its architecture supports real-time interfacing with a wide range of field sensors and actuators, providing a stable foundation for automated process management in large-scale industrial facilities.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP461-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eCentral Processing Unit (CPU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP Distributed Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Bus Support\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP high-speed communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Configuration\u003c\/td\u003e\n\u003ctd\u003eDual-redundant pairing supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Connectivity\u003c\/td\u003e\n\u003ctd\u003eHigh-density digital and analog I\/O integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Execution\u003c\/td\u003e\n\u003ctd\u003eReal-time deterministic PID and sequence control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eNatural convection \/ Fanless design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Width\u003c\/td\u003e\n\u003ctd\u003e4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Height\u003c\/td\u003e\n\u003ctd\u003e15.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Depth\u003c\/td\u003e\n\u003ctd\u003e20.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized process coordination in oil refineries and petrochemical plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManaging complex steam and water cycles in thermal power generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExecuting high-speed batch logic for pharmaceutical and specialty chemical production.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the CP461-10 support hot-swapping during operation?\u003c\/strong\u003e\u003cbr\u003eYes. When installed in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant FCU configuration\u003c\/strong\u003e, one\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be replaced while the partner processor continues operating, ensuring zero process interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the CP461-10 and the newer CP461-51?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-10\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an earlier hardware revision. While functionally similar in logic execution, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically features upgraded processor architecture for higher data throughput and improved computational performance.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745495804,"sku":"CP461-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-E11.jpg?v=1772786353"},{"product_id":"cp461-11-yokogawa-centum-vp-processor-module-cpu","title":"CP461-11 Yokogawa CENTUM VP Processor Module CPU","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-reliability central processing module engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Distributed Control System (DCS)\u003c\/strong\u003e. This module serves as the primary computational engine within a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Unit (FCU)\u003c\/strong\u003e, managing real-time process data, executing complex control algorithms, and coordinating communication across the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP network\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for mission-critical industrial environments where deterministic performance and long-term hardware stability are essential.\u003c\/p\u003e\n\u003cp\u003eManufactured to rigorous Japanese quality standards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efanless, solid-state design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat eliminates mechanical wear points and significantly increases\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMean Time Between Failures (MTBF)\u003c\/strong\u003e. Its architecture supports high-speed logic processing and is fully compatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant configurations\u003c\/strong\u003e, allowing seamless, bumpless failover to a standby processor in the event of hardware fault.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP461-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP Distributed Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Function\u003c\/td\u003e\n\u003ctd\u003eReal-time Logic Solver and Communication Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Support\u003c\/td\u003e\n\u003ctd\u003eDual-redundant configuration supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e8.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Height\u003c\/td\u003e\n\u003ctd\u003e10.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Depth\u003c\/td\u003e\n\u003ctd\u003e14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized regulatory control in upstream oil and gas production facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoordinating steam turbine and boiler logic in large-scale thermal power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManaging complex chemical reactor sequences requiring high-speed data sampling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary difference between the CP461-11 and CP461-51?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-11\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically an earlier hardware revision or regional model variant, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003egenerally features upgraded processor architecture and higher computational performance. Always verify FCU baseplate compatibility before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the CP461-11 be replaced while the plant is running?\u003c\/strong\u003e\u003cbr\u003eYes. If configured in a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant system\u003c\/strong\u003e, one CP461-11 module can be hot-swapped while the secondary processor continues controlling the process without interruption.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745626876,"sku":"CP461-11","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/PW484-512.jpg?v=1772786353"},{"product_id":"cp461-51-yokogawa-central-processor-module","title":"CP461-51 Yokogawa Central Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance central processing unit designed as the primary intelligence module for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Field Control Units (FCU)\u003c\/strong\u003e. Featuring a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-core ARM Cortex-A57 architecture\u003c\/strong\u003e, this module provides the computational power required for real-time process control, complex regulatory loops, and sequence logic execution. With a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.0 GHz clock speed\u003c\/strong\u003e, the CP461-51 delivers near-instantaneous response for industrial automation tasks.\u003c\/p\u003e\n\u003cp\u003eAs a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“Standard Type” (-51) module\u003c\/strong\u003e, it does not include explosion protection and is optimized for installation in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eclimate-controlled control rooms or non-hazardous rack environments\u003c\/strong\u003e. The CP461-51 is engineered for high availability and supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant CPU pairing\u003c\/strong\u003e, ensuring uninterrupted plant operations in the event of hardware failure. Compatibility with industrial real-time operating systems such as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVxWorks\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures deterministic execution for mission-critical automation workloads.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP461-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eDual-core ARM Cortex-A57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClock Speed\u003c\/td\u003e\n\u003ctd\u003e2.0 GHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System Support\u003c\/td\u003e\n\u003ctd\u003eLinux, VxWorks, Yokogawa real-time kernels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP (AFV30 \/ AFV40 series compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Type\u003c\/td\u003e\n\u003ctd\u003eStandard Type (Non-explosion protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy Capabilities\u003c\/td\u003e\n\u003ctd\u003eBumpless failover in dual-redundant configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Width\u003c\/td\u003e\n\u003ctd\u003e6.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Height\u003c\/td\u003e\n\u003ctd\u003e21.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Depth\u003c\/td\u003e\n\u003ctd\u003e16.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized logic control for large-scale oil and gas refinery units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoordinating turbine and boiler safety\/control sequences in power plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed data aggregation for chemical batch manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between CP461-51 and CP461-E1?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the standard industrial version for general use, while the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE1 variant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically includes enhanced compliance certifications or specialized hardware revisions for specific regional or application requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CP461-51 hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes. In dual-redundant FCU configurations, a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-51\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be replaced while the secondary processor continues to control the process without downtime.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745692412,"sku":"CP461-51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-E11.jpg?v=1772786353"},{"product_id":"cp461-e1-yokogawa-centum-vp-processor-module","title":"CP461-E1 Yokogawa CENTUM VP Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-E1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the high-performance central processing unit for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP Field Control Units (FCU)\u003c\/strong\u003e. This module is engineered to execute complex regulatory control, sequence logic, and data computing functions with the high-speed reliability required for large-scale process industries. As an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“E1” variant\u003c\/strong\u003e, it features enhanced communication capabilities and is designed to integrate seamlessly into modern\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEthernet-based control architectures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBuilt to Japanese engineering standards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-E1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emanages synchronization of I\/O modules and maintains real-time communication with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHuman Interface Stations (HIS)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eVnet\/IP control network\u003c\/strong\u003e. Its compact, fanless design minimizes maintenance requirements while providing robust computational power for stable plant operations in oil, gas, and power generation sectors.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eCP461-E1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP Distributed Control System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Architecture\u003c\/td\u003e\n\u003ctd\u003eHigh-speed real-time logic processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Compatibility\u003c\/td\u003e\n\u003ctd\u003eVnet\/IP control communication optimized\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003e8.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Height\u003c\/td\u003e\n\u003ctd\u003e10.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Depth\u003c\/td\u003e\n\u003ctd\u003e14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized process control for petrochemical refinery units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoordinating boiler and turbine logic in thermal power generation plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManaging complex batch processing in pharmaceutical and fine chemical manufacturing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the \"E1\" suffix on this processor?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eE1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuffix typically indicates hardware revision or regional compliance certification (such as CE compliance), ensuring compatibility with international industrial standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the CP461-E1 hot-swappable in a redundant system?\u003c\/strong\u003e\u003cbr\u003eYes. In dual-redundant FCU configurations, a single\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP461-E1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecan be replaced while the partner CPU continues operating, enabling maintenance without process interruption.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745725180,"sku":"CP461-E1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-E1.jpg?v=1772786353"},{"product_id":"yokogawa-scp461-51-s1-processor-module","title":"Yokogawa SCP461-51-S1 Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-51-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance safety processor module designed for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa ProSafe-RS Safety Instrumented System (SIS)\u003c\/strong\u003e. This module functions as the central\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elogic solver\u003c\/strong\u003e, executing critical safety loops and emergency shutdown (ESD) strategies with extreme precision. Engineered for high-integrity environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-51-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures process risks are mitigated through rapid logic execution and comprehensive internal diagnostics.\u003c\/p\u003e\n\u003cp\u003eAs an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e“S1” variant\u003c\/strong\u003e, this module is optimized for single-processor or redundant configurations within a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSafety Control Unit (SCU)\u003c\/strong\u003e. It continuously monitors internal hardware health and communication integrity with I\/O modules, providing a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSIL3-capable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efoundation for industrial safety applications. Its compact, fanless design and high manufacturing standards ensure long-term stability in chemical, oil, and gas industry environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003eSCP461-51-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eProSafe-RS Safety Instrumented System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eReal-time Safety Logic Solver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL3 capable (in redundant configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Suffix\u003c\/td\u003e\n\u003ctd\u003e-51 (Standard Type), -S1 (Standard Logic Support)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Execution Time\u003c\/td\u003e\n\u003ctd\u003eMillisecond-level safety response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Width\u003c\/td\u003e\n\u003ctd\u003e8.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Height\u003c\/td\u003e\n\u003ctd\u003e10.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Depth\u003c\/td\u003e\n\u003ctd\u003e14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eExecuting Emergency Shutdown (ESD) logic in hydrocarbon processing plants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManaging Fire and Gas (F\u0026amp;G) detection and mitigation sequences.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eActing as a High-Pressure Protection System (HIPPS) controller for pipeline integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the SCP461-51-S1 be used in a redundant pair?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-51-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed to work in dual-redundant architectures. If one processor experiences a fault, the standby unit takes over control seamlessly to maintain safety coverage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the SCP461 and SCP451?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSCP461-51-S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etypically provides higher processing capacity and larger memory resources compared to older SCP451 series processors, making it suitable for more complex safety logic and larger I\/O configurations.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745790716,"sku":"SCP461-51 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP461-51_S11.jpg?v=1772610735"},{"product_id":"yokogawa-pw504-power-supply-module","title":"Yokogawa PW504 Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW504\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-capacity\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDC-to-DC power converter module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003especifically engineered for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM VP \/ VE \/ VN distributed control systems (DCS)\u003c\/strong\u003e. Unlike standard AC-input supplies, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW504\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis optimized for industrial facilities that utilize a centralized\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24V DC battery plant\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor bulk DC power distribution network. It serves as a ruggedized power interface, delivering stable regulated voltage to critical system components, including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density I\/O nests and field control processors\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eBuilt for demanding process environments, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW504\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP66-rated enclosure\u003c\/strong\u003e, providing superior protection against dust and moisture ingress. Its high-efficiency thermal design allows consistent performance in extreme temperatures, while its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1200W power rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures that large-scale DCS architectures remain fully energized under peak load conditions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Identification\u003c\/td\u003e\n\u003ctd\u003ePW504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Architecture\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM VP \/ VE \/ VN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 V to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (System Internal Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Rated Power\u003c\/td\u003e\n\u003ctd\u003e1200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Efficiency\u003c\/td\u003e\n\u003ctd\u003e90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-20 °C to +70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e240 mm × 140 mm × 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e5.0 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized DC power management for offshore oil and gas production platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePowering high-availability safety controllers in petrochemical refining.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eField-mounted I\/O stations requiring IP66 protection in water treatment facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the PW504 be used in a redundant power configuration?\u003c\/strong\u003e\u003cbr\u003eYes. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW504\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis typically deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant pairs\u003c\/strong\u003e, ensuring continuous system operation if one module or input feed fails.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat are the advantages of the IP66 rating for this module?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP66 rating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows the PW504 to be installed in environments exposed to hosedown cleaning or heavy particulate contamination, reducing the need for expensive sealed secondary enclosures.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745823484,"sku":"PW504","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/PW5042.jpg?v=1772610735"},{"product_id":"pw484-50-yokogawa-24v-dc-power-supply-module","title":"PW484-50 Yokogawa 24V DC Power Supply Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePW484-50\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized 24 V DC power supply module designed for Yokogawa control systems. It provides regulated DC power to Field Control Units (FCU), FIO Node Units, and Optical ESB Bus Repeater Units, ensuring stable operation of sensitive processors and I\/O modules. The \"50\" suffix denotes a standard configuration for non-hazardous locations, offering a cost-effective solution for secure control environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003ePW484-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Current\u003c\/td\u003e\n\u003ctd\u003e5.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Profile\u003c\/td\u003e\n\u003ctd\u003eRegulated DC via exclusive backplane connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Support\u003c\/td\u003e\n\u003ctd\u003eSingle or Dual-Redundant setup (requires two modules)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eFront-panel LEDs for power health and fault monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eUp to 95% (high-efficiency switching design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C (-4°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e146.5 × 190 × 199.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Redundancy\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstalled in designated power slots (P1 and P2) of Yokogawa base plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDual-redundant configuration allows two modules to share the load; if one fails, the other immediately assumes the full load without system interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe PW484-50 is widely used in industrial process control rooms, distributed control system cabinets, and mission-critical automation installations requiring high-reliability 24 V DC power for FCUs, FIO nodes, and ESB repeaters.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the PW484-50 be used as a standalone 24 V supply?\u003c\/strong\u003e\u003cbr\u003eNo, it requires the exclusive Yokogawa base plate connector and cannot function as a general-purpose power source.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the PW484 differ from the PW482?\u003c\/strong\u003e\u003cbr\u003eThe PW482 is designed for 220–240 V AC mains input, whereas the PW484-50 is tailored for 24 V DC battery or plant power systems.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746745856252,"sku":"PW484-50","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/PW484-50.jpg?v=1770961371"},{"product_id":"scp451-11-s1-yokogawa-processor-module-new-original-stock","title":"SCP451-11 S1 YOKOGAWA Processor Module New \u0026 Original Stock","description":"\u003cp\u003eConfigured for high-speed logic execution and process control in CENTUM VP systems, the \u003cstrong\u003eYOKOGAWA SCP451-11\u003c\/strong\u003e (\u003cstrong\u003eSCP451-11\u003c\/strong\u003e Processor Module) provides direct physical\/electrical execution. This module handles real-time instruction sets and data processing duties, interfacing directly with the control bus to manage I\/O synchronization and regulatory control loops within the DCS architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eSCP451-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eJAPAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2.5 cm x 20.3 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eStandard industrial cabinet range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eDetermined by system backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eProcessor Type\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eS1 Series Logic Processor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe SCP451-11 maintains integration integrity through standard industrial communication protocols. The module architecture supports precise loop control, ensuring high-fidelity signal processing for analog and digital inputs. It utilizes advanced internal circuitry to manage 4-20 mA HART loop protocol data streams, facilitating seamless transmission between field instrumentation and the controller backplane. The hardware is designed to maintain signal isolation, reducing the requirement for external signal conditioning while ensuring process variables are updated at the defined scan rates within the DCS controller environment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the SCP451-11 support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping capabilities are dependent on the specific revision of the backplane and the redundant controller configuration. Consult the system status indicators to ensure the module is not in a primary control state before physical extraction.\u003c\/p\u003e\n\u003cp\u003eQ: What are the requirements for firmware compatibility on this processor?\u003c\/p\u003e\n\u003cp\u003eA: Firmware must match the defined project database version and the specific CENTUM VP software suite installed. Mismatched firmware versions can result in communication errors on the control bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet power is isolated before inserting or removing the module from the rack slot.\u003c\/li\u003e\n\u003cli\u003eVerify the alignment of the module connector pins with the backplane slots to prevent mechanical damage to the interface pins.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the integrated locking levers to ensure proper physical contact and vibration resistance.\u003c\/li\u003e\n\u003cli\u003eProper grounding of the cabinet and shielding of connected I\/O cabling is mandatory to mitigate electromagnetic interference and ensure the stability of the control loops.\u003c\/li\u003e\n\u003cli\u003eVerify that the internal cooling air path is not obstructed by wiring or cable ducts to maintain the module operating temperature within specified limits.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131365990652,"sku":"SCP451-11 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP451-11_S1.jpg?v=1779673749"},{"product_id":"yokogawa-cp461-10-s1-processor-module-new-original-stock","title":"YOKOGAWA CP461-10 S1 Processor Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP461-10 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP461-10\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for core control processing and communication automation within CENTUM CS3000 and CENTUM VP systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP461-10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eRefer to documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2.5 cm x 20.3 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndustrial environmental standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eProcessor Speed\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e10 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e64 KB RAM, 32 KB EPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e1 Hz to 100 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003e+\/- 0.01 percent FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CP461-10 utilizes established DCS instrumentation standards to maintain loop integrity. The module architecture is designed to support 4-20 mA HART loop protocol integration, enabling real-time transmission of process variables. To ensure signal fidelity across complex control architectures, the design incorporates channel-to-channel isolation, which mitigates ground loop interference and cross-channel electrical noise. This structural approach ensures that high-precision control signals are processed with the required accuracy for regulatory loop stability.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CP461-10 S1 be hot-swapped while the CENTUM controller is in run mode?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is restricted by the specific backplane configuration. Ensure the controller is in a secondary or standby state prior to module extraction to prevent system-wide I\/O communication loss.\u003c\/p\u003e\n\u003cp\u003eQ: How should the communication ports be configured for Modbus RTU integration?\u003c\/p\u003e\n\u003cp\u003eA: Configuration must be defined through the system engineering station. Ensure the baud rate, parity, and stop bit settings match the external slave device requirements to avoid data packet collision on the communication bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the rack slot is free of debris before aligning the module with the backplane connector.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is seated fully and secured using the integrated front-panel locking mechanisms to maintain contact pressure.\u003c\/li\u003e\n\u003cli\u003ePerform cable routing within the cabinet using designated wire ducts to prevent signal attenuation caused by induction from high-voltage power lines.\u003c\/li\u003e\n\u003cli\u003eGround the rack assembly to the cabinet potential equalization bus to ensure compliance with electromagnetic compatibility standards.\u003c\/li\u003e\n\u003cli\u003eConduct a visual inspection of the module status LEDs after power-on to verify successful self-diagnostic execution and communication link synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131416355068,"sku":"CP461-10 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-10_S12.jpg?v=1779673749"},{"product_id":"processor-module-s2cp471-01-yokogawa-new-original-stock","title":"Processor Module S2CP471-01 YOKOGAWA  New \u0026 Original Stock","description":"\u003cp\u003eConfigured for high-speed logic execution in CENTUM VP control environments, the \u003cstrong\u003eYOKOGAWA S2CP471-01\u003c\/strong\u003e (\u003cstrong\u003eS2CP471-01\u003c\/strong\u003e Processor Module) provides direct physical\/electrical execution. This module serves as a central computational unit, managing task scheduling and I\/O data processing across the controller backplane to maintain regulatory loop stability.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eS2CP471-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5.1 cm x 20.3 cm x 14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndustrial rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eBackplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eProcessing Capacity\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eReal-time task execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe S2CP471-01 integrates into the DCS architecture to facilitate precise measurement and control. The module supports standard industrial signal protocols, ensuring compatibility with 4-20 mA HART loop instrumentation. It features robust channel-to-channel isolation circuitry designed to prevent common-mode noise interference during analog data acquisition. By maintaining galvanic separation between field-side signals and the internal processor bus, the module ensures data integrity in environments with high electrical noise profiles or varying ground potentials.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support redundant controller configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the S2CP471-01 is compatible with redundant processor pairings. Ensure that both modules are synchronized via the dedicated communication link before initiating the primary control function.\u003c\/p\u003e\n\u003cp\u003eQ: What are the physical requirements for module replacement?\u003c\/p\u003e\n\u003cp\u003eA: When replacing the module, ensure the cabinet environment is free from particulate contamination. Confirm the locking levers are fully engaged to ensure the backplane connectors are seated to the required depth for signal continuity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate the power supply to the specific controller rack before attempting to install or remove the processor module.\u003c\/li\u003e\n\u003cli\u003eCheck the backplane interface pins for any signs of oxidation or mechanical deformation prior to insertion.\u003c\/li\u003e\n\u003cli\u003eAlign the module along the guide rails to prevent lateral stress on the internal bus connectors.\u003c\/li\u003e\n\u003cli\u003eSecure the front panel fasteners to ensure the assembly maintains proper alignment and vibration resistance during machine operation.\u003c\/li\u003e\n\u003cli\u003eVerify proper shielding and grounding of the I\/O cabling connected to the associated base plates to minimize signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131417829628,"sku":"S2CP471-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/S2CP471-012.jpg?v=1779673749"},{"product_id":"cp451-51-yokogawa-processor-module-new-original-stock","title":"CP451-51 YOKOGAWA Processor Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP451-51\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP451-51\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for centralized logic execution and data processing within CENTUM distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP451-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eJAPAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e10.2 cm x 3.8 cm x 10.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndustrial rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eBackplane load dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eProcessing Function\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eReal-time control execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CP451-51 is engineered to maintain high fidelity in control loop data acquisition and signal processing. It supports integration with standard 4-20 mA HART loop protocol architectures, ensuring consistent communication between field instrumentation and the DCS controller. The module utilizes internal isolation techniques to manage signal integrity, effectively mitigating the risks of ground loops and common-mode interference. This ensures that process variables are relayed to the central processor with the precision required for stable regulatory control in dynamic industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module compatible with existing CENTUM VP backplane configurations?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility depends on the specific revision of the backplane and the control system database configuration. Verify the module part number against the system bill of materials before installation.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific restrictions regarding the removal of this module while the system is under load?\u003c\/p\u003e\n\u003cp\u003eA: Removing the processor module while the system is in an active control state will trigger a fail-safe condition. Ensure the control logic has been transferred to a redundant partner module or the system is in a safe stop state before extraction.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet is de-energized to prevent electrical faults during the seating of the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module along the designated guide rails of the rack to avoid bending the backplane pins during engagement.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the provided locking tabs to ensure constant pressure and vibration resistance.\u003c\/li\u003e\n\u003cli\u003eVerify that all shielded I\/O cabling is properly grounded to the cabinet's common ground bus to maintain the signal-to-noise ratio.\u003c\/li\u003e\n\u003cli\u003eInspect the status indicators after initialization to confirm the processor has successfully passed the power-on self-test (POST).\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131421827324,"sku":"CP451-51","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP451-51.jpg?v=1779673749"},{"product_id":"yokogawa-processor-module-cp451-50-s2-new-original-stock","title":"Yokogawa Processor Module CP451-50 S2 New \u0026 Original Stock","description":"\u003cp data-path-to-node=\"1\"\u003eThe \u003cb data-path-to-node=\"1\" data-index-in-node=\"4\"\u003eYOKOGAWA CP451-50 S2\u003c\/b\u003e, also cataloged as the \u003cb data-path-to-node=\"1\" data-index-in-node=\"48\"\u003eCP451-50\u003c\/b\u003e Processor Module, operates as a dedicated hardware component for real-time logic execution and process data management within CENTUM DCS platforms.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"2\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"3\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,1,1,0\"\u003eCP451-50 S2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,2,1,0\"\u003eYokogawa\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,3,1,0\"\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,4,1,0\"\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,0,0\"\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,5,1,0\"\u003e5.1 cm x 20.3 cm x 15.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,0,0\"\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,6,1,0\"\u003eIndustrial environmental standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,0,0\"\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,7,1,0\"\u003eBackplane bus load dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,0,0\"\u003eProcessing Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"3,8,1,0\"\u003eHigh-speed logic control execution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-path-to-node=\"4\"\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp data-path-to-node=\"5\"\u003eThe CP451-50 S2 integrates into the control network to facilitate reliable instrumentation communication. The module is designed to interface with 4-20 mA HART loop protocol standards, allowing for the transmission of critical process parameters from field devices to the control software. To ensure signal accuracy, the architecture employs channel-to-channel isolation, which mitigates interference from electrical noise and potential differences between field loops. This implementation ensures that analog data streams remain stable, supporting the high-precision requirements of regulatory control loops within the DCS architecture.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"6\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp data-path-to-node=\"7\"\u003eQ: Does the CP451-50 S2 support redundant pairing for continuous control?\u003c\/p\u003e\n\u003cp data-path-to-node=\"7\"\u003eA: The module architecture supports redundant configurations. Ensure that both primary and standby modules share the same hardware revision and database settings to prevent synchronization errors during failover.\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eQ: What is the procedure if the module fails the power-on self-test?\u003c\/p\u003e\n\u003cp data-path-to-node=\"8\"\u003eA: A failed self-test typically indicates a hardware fault or an incomplete connection to the backplane. Inspect the connector pins for damage, verify the backplane power supply, and reseat the module firmly.\u003c\/p\u003e\n\u003ch3 data-path-to-node=\"10\"\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul data-path-to-node=\"11\"\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,0,0\"\u003eIsolate the power supply to the controller rack to prevent accidental electrical contact during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,1,0\"\u003eEnsure that the module is inserted into the correct slot as defined by the system cabinet layout drawings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,2,0\"\u003eAlign the module with the guide rails and apply firm, even pressure until the backplane connectors are fully engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,3,0\"\u003eTighten the front panel locking screws to maintain physical stability and ground continuity with the rack chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp data-path-to-node=\"11,4,0\"\u003eCheck that all external signal cabling is securely shielded and routed away from high-voltage conduits to prevent induced interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131423891708,"sku":"CP451-50 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP451-50_S22.jpg?v=1779673747"},{"product_id":"processor-module-cp471-01-yokogawa-new-original-stock","title":"Processor Module CP471-01 YOKOGAWA New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP471-01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP471-01\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for control logic execution and I\/O communication management within CENTUM VP platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eCP471\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBase Processor Module Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-01\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eStandard Configuration Identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP471-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eRefer to documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e170 mm x 105 mm x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndustrial environmental standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eCENTUM VP R6.01 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eESB bus via EC401 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CP471-01 is engineered to maintain high-precision data flow through the ESB bus architecture. To ensure signal fidelity, the module utilizes internal channel-to-channel isolation when interfacing with field instrumentation. This design effectively suppresses noise and prevents ground loops that typically affect 4-20 mA HART loop communication in dense industrial racks. By managing these signal parameters at the processor level, the module ensures that control loops maintain stability and that process variable data remains accurate during high-speed scanning operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CP471-01 support hot-swapping in a dual-redundant configuration? A: Yes, the module supports hot-swapping, but it must be performed according to the specific rack slot sequence to maintain control continuity. Ensure the partner module is in a primary state before removing the standby unit.\u003c\/p\u003e\n\u003cp\u003eQ: What are the requirements for the ESB bus interface? A: The module requires an EC401 coupler with style code S3 or later to establish communication on the ESB bus. Ensure the bus cabling is properly shielded to meet electromagnetic interference standards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the Field Control Unit (FCU) power is fully isolated before mounting the module into the rack.\u003c\/li\u003e\n\u003cli\u003eAlign the module along the guide rails carefully to avoid damaging the backplane pins or the ESB bus interface connectors.\u003c\/li\u003e\n\u003cli\u003eSecure the front module mounting screws to the rack frame to ensure a rigid electrical ground connection.\u003c\/li\u003e\n\u003cli\u003eRoute all communication cables within the designated cable trays to minimize crosstalk and ensure compliance with electromagnetic compatibility requirements.\u003c\/li\u003e\n\u003cli\u003ePerform a system diagnostic check after installation to verify the module synchronization state within the redundant controller pair.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131500798204,"sku":"CP471-01","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP471-01.jpg?v=1779673748"},{"product_id":"cp461-50-s1-yokogawa-processor-module-new-original-stock","title":"CP461-50 S1 Yokogawa Processor Module New \u0026 Original Stock","description":"\u003cp\u003eConfigured for high-speed logic execution in CENTUM VP control systems, the \u003cstrong\u003eYOKOGAWA CP461-50 S1\u003c\/strong\u003e (\u003cstrong\u003eCP461-50\u003c\/strong\u003e Processor Module) provides direct physical\/electrical execution. This module functions as the core computational unit for process control, managing real-time I\/O data processing and regulatory control loop stability within the Field Control Unit (FCU) architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP461-50 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eRefer to documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2.5 cm x 20.3 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndustrial rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eProcessing Capacity\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eHigh-speed real-time execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CP461-50 S1 utilizes industrial-grade communication pathways to maintain signal integrity between field instrumentation and the DCS controller. The hardware design incorporates channel-to-channel isolation to suppress common-mode electrical noise and prevent ground loops during the acquisition of 4-20 mA HART loop protocol data. This galvanic separation ensures that process variables remain within strict accuracy tolerances, preventing measurement drift or communication errors caused by potential differences across the plant-wide control network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the CP461-50 S1 compatible with redundant controller pairs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, this module supports redundant deployment. Ensure both modules within the pair possess matching hardware and firmware versions to maintain deterministic synchronization and prevent switchover latency.\u003c\/p\u003e\n\u003cp\u003eQ: Can this processor module be integrated with non-Yokogawa field devices?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the field devices adhere to standard 4-20 mA HART signaling requirements. Configuration in the engineering station must accurately reflect the specific device ID and communication parameters.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet is powered down before installation to protect the backplane bus interface from electrical transients.\u003c\/li\u003e\n\u003cli\u003eVerify that the rack slot is clear of mechanical obstructions and that the guide rails are aligned with the module chassis.\u003c\/li\u003e\n\u003cli\u003eInsert the module firmly into the backplane, ensuring the connector pins engage fully without lateral resistance.\u003c\/li\u003e\n\u003cli\u003eSecure the front panel locking mechanisms to maintain contact pressure and provide vibration-resistant mounting.\u003c\/li\u003e\n\u003cli\u003eVerify that all shielded I\/O cabling is properly terminated at the cabinet common ground to mitigate electromagnetic interference before initiating system power-up.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131506598140,"sku":"CP461-50 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-50_S1.jpg?v=1779673748"},{"product_id":"cp471-yokogawa-processor-module-new-original-stock","title":"CP471 YOKOGAWA Processor Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP471\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP471\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for control logic execution and I\/O communication management within CENTUM VP platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP471\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eRefer to documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e170 mm x 105 mm x 32 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndustrial environmental standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCompatibility\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eCENTUM VP R6.01 or later\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003eESB bus via EC401 coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CP471 is engineered to maintain high-precision data flow through the ESB bus architecture. To ensure signal fidelity, the module utilizes internal channel-to-channel isolation when interfacing with field instrumentation. This design effectively suppresses noise and prevents ground loops that typically affect 4-20 mA HART loop communication in dense industrial racks. By managing these signal parameters at the processor level, the module ensures that control loops maintain stability and that process variable data remains accurate during high-speed scanning operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CP471 support hot-swapping in a dual-redundant configuration?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping, but it must be performed according to the specific rack slot sequence to maintain control continuity. Ensure the partner module is in a primary state before removing the standby unit.\u003c\/p\u003e\n\u003cp\u003eQ: What are the requirements for the ESB bus interface?\u003c\/p\u003e\n\u003cp\u003eA: The module requires an EC401 coupler with style code S3 or later to establish communication on the ESB bus. Ensure the bus cabling is properly shielded to meet electromagnetic interference standards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure that the Field Control Unit (FCU) power is fully isolated before mounting the module into the rack.\u003c\/li\u003e\n\u003cli\u003eAlign the module along the guide rails carefully to avoid damaging the backplane pins or the ESB bus interface connectors.\u003c\/li\u003e\n\u003cli\u003eSecure the front module mounting screws to the rack frame to ensure a rigid electrical ground connection.\u003c\/li\u003e\n\u003cli\u003eRoute all communication cables within the designated cable trays to minimize crosstalk and ensure compliance with electromagnetic compatibility requirements.\u003c\/li\u003e\n\u003cli\u003ePerform a system diagnostic check after installation to verify the module synchronization state within the redundant controller pair.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131508400380,"sku":"CP471","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP471.jpg?v=1779673748"},{"product_id":"yokogawa-processor-module-cp461-53-new-original-stock","title":"YOKOGAWA Processor Module CP461-53 New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP461-53\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP461-53\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for centralized logic execution and data processing within distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP461-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eRefer to documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e2.5 cm x 20.3 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eCommunication\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eEthernet, RS-232, RS-485, Modbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CP461-53 is designed to facilitate high-speed communication between the controller and field instrumentation. To ensure data integrity, the module architecture supports channel-to-channel isolation, which is critical for suppressing electromagnetic interference and preventing ground loops in harsh industrial environments. This approach enables stable 4-20 mA HART loop protocol transmission and robust integration with serial communication buses like RS-485. The internal processing logic handles complex control functions, ensuring that real-time process variables are accurately mapped to the control bus for regulatory loop maintenance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CP461-53 support simultaneous multi-protocol communication?\u003c\/p\u003e\n\u003cp\u003eA: The module architecture is designed to handle multiple communication interfaces, including Modbus and Ethernet, concurrently. Ensure the system engineering station is configured to prioritize task execution to avoid bus congestion.\u003c\/p\u003e\n\u003cp\u003eQ: What are the physical mounting requirements for the 24 VDC power connection?\u003c\/p\u003e\n\u003cp\u003eA: The module must be connected to a regulated 24 VDC power source. Ensure the cable gauge is sufficient to minimize voltage drop and that the power supply is isolated from inductive noise sources such as motor drives.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the cabinet power is fully isolated before seating the module to protect against potential short circuits on the backplane.\u003c\/li\u003e\n\u003cli\u003eAlign the module along the internal guide rails and apply firm, steady pressure until the rear connector pins seat securely into the backplane receptacles.\u003c\/li\u003e\n\u003cli\u003eUtilize the integrated front-panel fasteners to lock the module into place, ensuring vibration resistance and electrical contact continuity.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables, particularly RS-232 and RS-485 lines, away from high-voltage power conduits to minimize cross-talk and signal distortion.\u003c\/li\u003e\n\u003cli\u003eVerify that the cabinet temperature remains within the -20 deg C to +60 deg C range to ensure long-term hardware reliability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131512463612,"sku":"CP461-53","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-53.jpg?v=1779673748"},{"product_id":"processor-module-cp401-11-s1-yokogawa-new-original-stock","title":"Processor Module CP401-11 S1 YOKOGAWA New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP401-11 S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP401-11\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for centralized logic execution and I\/O communication management within distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP401-11 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eJAPAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e8.1 cm x 10.3 cm x 14.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndustrial environmental standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eProcessing Capacity\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eReal-time logic control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CP401-11 S1 is engineered to maintain high-fidelity data acquisition within DCS architectures. The module supports seamless integration with standard 4-20 mA HART loop protocol instrumentation, ensuring consistent communication between field devices and the controller backplane. To enhance signal stability, the architecture incorporates channel-to-channel isolation, which mitigates the risk of common-mode interference and ground loop formation. This hardware-level separation ensures that analog process variables remain accurate, facilitating stable regulatory control loops even in environments characterized by high electrical noise.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CP401-11 S1 support hot-swapping on an active control rack?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is subject to system-specific backplane power constraints and redundancy status. Confirm the module is in a standby or redundant-ready state before removal to prevent control logic disruption.\u003c\/p\u003e\n\u003cp\u003eQ: How can I verify the module's communication status after installation?\u003c\/p\u003e\n\u003cp\u003eA: Monitor the status LEDs on the front panel and verify the heartbeat signal through the system engineering station’s diagnostics interface to ensure successful bus synchronization.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet is isolated from power sources prior to module insertion to prevent backplane pin damage from electrical transients.\u003c\/li\u003e\n\u003cli\u003eAlign the module along the internal rack guides to ensure the rear-facing interface connectors engage uniformly with the backplane.\u003c\/li\u003e\n\u003cli\u003eSecure the front locking mechanisms to maintain the required contact pressure and physical vibration resistance.\u003c\/li\u003e\n\u003cli\u003eGround the shield of any attached I\/O cabling to the cabinet's designated potential equalization bus to minimize electromagnetic susceptibility.\u003c\/li\u003e\n\u003cli\u003ePerform a visual inspection of the interface pins after installation to ensure no mechanical deformation occurred during the seating process.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131515707644,"sku":"CP401-11 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP401-11_S11.jpg?v=1779673749"},{"product_id":"scp451-51-s1-yokogawa-processor-module-new-original-stock","title":"SCP451-51-S1 YOKOGAWA Processor Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA SCP451-51-S1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSCP451-51\u003c\/strong\u003e Processor Module, operates as a dedicated hardware component for high-speed logic execution and communication coordination within distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSuffix\/Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eSCP451\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eBase Processor Module Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003e-51\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eStandard configuration with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003e-S1\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eVersion featuring ISA Standard G3 environmental compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eSCP451-51-S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eRefer to documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e16 cm x 6 cm x 21 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eIndustrial environmental standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003eISA Standard G3 compliance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe SCP451-51-S1 is engineered to maintain high-precision data flow and regulatory loop control. It supports integration with standard 4-20 mA HART loop protocol architectures, ensuring consistent communication between field instrumentation and the DCS controller. To ensure signal fidelity across complex control architectures, the design incorporates channel-to-channel isolation, which mitigates ground loop interference and cross-channel electrical noise. This structural approach ensures that process variables are processed with the required accuracy for stable control loop execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What does the ISA Standard G3 compliance signify for this module?\u003c\/p\u003e\n\u003cp\u003eA: ISA Standard G3 compliance indicates that the module's circuitry is treated to resist severe corrosion, making it suitable for deployment in harsh industrial atmospheres where chemical pollutants are present.\u003c\/p\u003e\n\u003cp\u003eQ: Is this processor compatible with third-party Modbus devices?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports communication with external devices via standardized serial or Ethernet protocols, provided they are configured correctly within the DCS engineering environment to match the controller's I\/O mapping.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the control cabinet power is isolated before inserting or removing the module to prevent electrical damage to the backplane pins.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the rack guide rails to ensure the connectors engage evenly and to prevent mechanical stress on the PCB.\u003c\/li\u003e\n\u003cli\u003eSecure the front-panel locking mechanisms to ensure the module maintains a rigid physical and electrical ground connection with the cabinet.\u003c\/li\u003e\n\u003cli\u003eVerify that all shielded I\/O cabling is properly terminated to the system's common ground bus to maintain signal-to-noise performance.\u003c\/li\u003e\n\u003cli\u003eConduct a system-level diagnostic check after installation to confirm that the module is successfully synchronized with the control bus and communicating with connected I\/O sub-systems.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131516756220,"sku":"SCP451-51-S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP451-11_S1.jpg?v=1779673749"},{"product_id":"cp451-51-s2-yokogawa-cpu-module-new-original-stock","title":"CP451-51 S2 YOKOGAWA CPU Module New \u0026 Original Stock","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA CP451-51S2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP451-51\u003c\/strong\u003e CPU Module, operates as a dedicated hardware component for real-time monitoring and control logic execution within distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eCP451-51S2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eRefer to documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e10.2 cm x 3.8 cm x 10.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-25 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e24 VDC (+10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eProcessor Speed\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e20 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMemory\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e32 KB RAM, 16 KB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe CP451-51S2 is engineered to maintain high-fidelity data acquisition and control signal distribution. The module supports RS-485 communication protocols, allowing for reliable serial data exchange between the controller and peripheral field instrumentation. To ensure signal integrity, the architecture employs channel-to-channel isolation, which is critical for suppressing common-mode electromagnetic interference in complex automation networks. By maintaining strict voltage regulation—converting input 24 VDC to internal 5 VDC logic levels—the module ensures stable performance of its integrated processor and memory arrays across fluctuating industrial supply conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swapping during system operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is restricted based on the specific controller rack and backplane power distribution design. Ensure the module is in an offline or standby state before removal to prevent control bus faults.\u003c\/p\u003e\n\u003cp\u003eQ: How should the RS-485 termination be handled?\u003c\/p\u003e\n\u003cp\u003eA: Proper termination is required at the end of the serial bus line to prevent signal reflections. Use an appropriate resistor as specified in the system communication manual to ensure data transmission stability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate the cabinet power supply before installation to protect the module's internal circuitry from electrical surges during pin engagement.\u003c\/li\u003e\n\u003cli\u003eAlign the module chassis precisely with the backplane guide rails to avoid lateral stress on the rear-mounted connectors.\u003c\/li\u003e\n\u003cli\u003eSecure the front locking tabs firmly to ensure the module maintains continuous contact with the backplane grounding system.\u003c\/li\u003e\n\u003cli\u003eMaintain appropriate cable routing, keeping RS-485 data lines physically separated from high-current power conduits to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that ambient cabinet temperature does not exceed the specified operating range of +70 deg C to prevent processor thermal throttling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49131533664508,"sku":"SCP451-51 S2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SCP451-11_S1.jpg?v=1779673749"}],"url":"https:\/\/www.electronicplc.com\/collections\/yokogawa-cpu-module.oembed?page=3","provider":"Electronic PLC","version":"1.0","type":"link"}