{"title":"Yokogawa I\/O Modules","description":"\u003cp\u003ePrecision in signal acquisition is the foundation of any Yokogawa control environment. This category features a full range of I\/O modules compatible with RIO, FIO, and N-IO architectures. From high-accuracy analog inputs (AAI series) to versatile digital signal processors (ADV series), these modules are built to withstand harsh industrial electrical environments while maintaining signal integrity. Whether you are replacing a single faulty point or expanding your field instrumentation capacity, these authentic Yokogawa I\/O components ensure seamless integration with your existing Field Control Stations (FCS).\u003c\/p\u003e","products":[{"product_id":"cp345-s1-processor-module-yokogawa","title":"CP345 S1 Processor Module Yokogawa","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP345 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessor module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa CENTUM Series DCS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eenvironments. Serving as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomputational core\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Control Stations (FCS)\u003c\/strong\u003e, it delivers\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edeterministic logic execution, high-speed data processing, and reliable communication management\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eEngineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical applications\u003c\/strong\u003e—including\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eenergy production, petrochemical refining, and continuous chemical processing\u003c\/strong\u003e—the CP345 S1 ensures\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoperational stability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emaximizes system uptime\u003c\/strong\u003e. Its\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact, rugged architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eallows dense installation in control cabinets, ideal for both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enew system deployments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emodernization of existing DCS infrastructures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Reference\u003c\/td\u003e\n\u003ctd\u003eCP345 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Category\u003c\/td\u003e\n\u003ctd\u003eProcessor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform Compatibility\u003c\/td\u003e\n\u003ctd\u003eYokogawa CENTUM Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e6.1 cm × 25.0 cm × 26.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePerformance and Integration\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCP345 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocessing power\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequired for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecomplex control strategies\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emulti-loop automation\u003c\/strong\u003e. By efficiently managing the interface between\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eremote field instruments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecentral operator station\u003c\/strong\u003e, it maintains\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprocess integrity\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand minimizes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003elatency in safety-critical loops\u003c\/strong\u003e. Its durable design simplifies maintenance, allowing seamless integration into existing FCS racks while supporting\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eplant-wide asset management\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the CP345 S1 compatible with existing CENTUM system firmware?\u003c\/strong\u003e\u003cbr\u003eA: Yes. It is intended for specific CENTUM series architectures. Verify your\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFCS firmware version\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand base unit compatibility for seamless operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does this module support redundant configurations?\u003c\/strong\u003e\u003cbr\u003eA: Yes. The CP345 S1 supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-availability dual-redundant processor setups\u003c\/strong\u003e, preventing system downtime in continuous manufacturing processes.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746719183100,"sku":"CP345 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP345_S1.jpg?v=1773650029"},{"product_id":"analog-input-module-yokogawa-aai143-s00","title":"Analog Input Module Yokogawa AAI143-S00","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI143-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel analog input module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eengineered for precise\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecurrent signal acquisition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein distributed control systems. It is designed to interface seamlessly with both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-wire transmitters\u003c\/strong\u003e, offering channel-level flexibility through pin-based configuration. With its robust\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egalvanic isolation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand high-speed data update period, this module ensures accurate process monitoring in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical automation environments\u003c\/strong\u003e. The unit includes an\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated transmitter power supply\u003c\/strong\u003e, simplifying field wiring while maintaining strict adherence to industrial signal integrity standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAI143-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAllowable Input Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Update Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19.0 V (at 20 mA) to 25.5 V (at 0 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Resistance (Power ON)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e270 Ω (20 mA) to 350 Ω (4 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute (Input to System)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e230 mA (5 V DC) and 540 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 μA per 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13 cm x 3 cm x 13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Advantages\u003c\/h3\u003e\n\u003cp\u003eDesigned for versatile field integration, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI143-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports selectable\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2-wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eor\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e4-wire\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etransmitter setups for each individual channel. This granular control allows for complex instrumentation layouts within a single module rack. Its high input impedance when powered off (500 kΩ or larger) protects the internal circuitry from accidental damage during maintenance, while the internal current limit of\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides essential loop protection against short-circuit conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: How do I configure the channel for a 2-wire vs 4-wire transmitter?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: The configuration is performed using physical settings on the module's pins for each individual channel, allowing for mixed-signal setups within the same unit.\u003c\/p\u003e\n\u003ch4\u003eQ: Does the module provide power to field transmitters?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, it includes an integrated\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etransmitter power supply\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edesigned to provide up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e25 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutput current, sufficient for standard loop-powered field instruments.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746737205500,"sku":"AAI143-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AAI143-S00.jpg?v=1773042241"},{"product_id":"yokogawa-aai543-s00-analog-output-module","title":"Yokogawa AAI543-S00 Analog Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI543-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 16-channel analog output module engineered for reliable process control within the CENTUM VP and ProSafe-RS environments. This module provides precise, galvanically isolated 4 to 20 mA signals, ensuring high signal integrity for actuators and control valves. It is specifically designed for high-availability applications, supporting redundant configurations to maintain continuous operation during maintenance or module failure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAI543-S00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 channels, fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstanding Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoad Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 750 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit-Open Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDetects currents below 0.65 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±48 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Update Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 μA per 10 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eReliability and Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI543-S00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures superior process stability through its robust isolation design, protecting sensitive control loops from common-mode noise and surges. It is fully compatible with standard Yokogawa I\/O racks, facilitating straightforward installation in existing infrastructure. Its support for redundant pairings makes it a cornerstone component for critical safety and control loops where downtime must be minimized.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Can the AAI543-S00 perform circuit-open detection?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, the module includes integrated detection circuitry that triggers an alarm when the output loop current drops below 0.65 mA, indicating a potential open circuit.\u003c\/p\u003e\n\u003ch4\u003eQ: Does this module require external power for the output loop?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: No, the module provides the loop current internally, though the power consumption requirements (5 V and 24 V DC) must be met by the system bus.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746738188540,"sku":"AAI543-S00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AAI143-S001.jpg?v=1773042241"},{"product_id":"aai543-h00-yokogawa-hart-analog-output-module","title":"AAI543-H00  Yokogawa HART Analog Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa AAI543-H00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density, 16-channel analog output module engineered for the CENTUM VP and ProSafe-RS distributed control systems. This module provides isolated 4 to 20 mA DC signals and integrates digital HART protocol communication, enabling seamless configuration and diagnostics for connected field instruments. Designed for critical process automation, it supports standard switch-over response times in redundant configurations to ensure high availability and operational stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth class=\"\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog Output Module (Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAAI543-H00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 channels, fully isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital communication via HART protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports standard switch-over response\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±16 μA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between channels and internal circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTypical Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThis module is widely utilized in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eoil and gas refineries\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical plants\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation facilities\u003c\/strong\u003e. It is primarily used for controlling actuators, positioners, and frequency converters that require precise mA current loop signaling and HART-based asset management.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eQ: Does the AAI543-H00 support non-HART devices?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, it is fully backward compatible with standard 4 to 20 mA devices, even if HART functionality is not required.\u003c\/p\u003e\n\u003ch4\u003eQ: Can this module be hot-swapped in a redundant configuration?\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, it is designed for ease of maintenance within Yokogawa I\/O racks, supporting online replacement during system operation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746738450684,"sku":"AAI543-H00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AAI543-H00.jpg?v=1773039116"},{"product_id":"yokogawa-aai543-h50-k4a00-analog-output-module","title":"Yokogawa AAI543-H50\/K4A00 Analog Output Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAI543-H50\/K4A00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel analog output module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by Yokogawa Electric Corporation for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control systems. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eisolated 4–20 mA DC output signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eintegrated HART communication support\u003c\/strong\u003e, enabling advanced field device diagnostics and bidirectional communication with intelligent instrumentation.\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eK4A00 configuration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincludes the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATK4A-00 KS cable interface adapter\u003c\/strong\u003e, allowing direct connection to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D terminal boards\u003c\/strong\u003e. This design simplifies field wiring, improves mechanical stability, and maintains signal integrity in high-density control cabinet installations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAI543-H50\/K4A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4–20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHART Protocol\u003c\/td\u003e\n\u003ctd\u003eFully supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±48 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003e0 – 750 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"selectTdClass\"\u003eTemperature Drift\u003c\/td\u003e\n\u003ctd class=\"selectTdClass\"\u003e±16 µA \/ 10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"selectTdClass\"\u003eOpen Circuit Detection\u003c\/td\u003e\n\u003ctd class=\"selectTdClass\"\u003e\u0026lt; 0.65 mA trigger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"selectTdClass\"\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd class=\"selectTdClass\"\u003e1500V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"selectTdClass\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd class=\"selectTdClass\"\u003e230 mA @ 5V DC; 540 mA @ 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Reliability\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFully isolated output architecture prevents ground loop interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eredundant control configurations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith hot-standby switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKS cable interface ensures secure, organized high-speed signal wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical process industries\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as power, petrochemical, and chemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the module operate without redundancy?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esingle and redundant system architectures\u003c\/strong\u003e. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eH50 designation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eindicates support for redundant switch-over operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the function of the K4A00 \/ ATK4A-00 adapter?\u003c\/strong\u003e\u003cbr\u003eThe adapter provides a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS cable interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebetween the module and AEA4D terminal boards, ensuring secure and isolated 16-channel signal wiring.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746738745596,"sku":"AAI543-H50\/K4A00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/CP461-E1.jpg?v=1772786353"},{"product_id":"yokogawa-ata4d-00-redundant-pressure-clamp-terminal-block","title":"Yokogawa ATA4D-00 Redundant Pressure Clamp Terminal Block","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATA4D-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant pressure clamp terminal interface\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by Yokogawa Electric Corporation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Instrument Platform (FIO)\u003c\/strong\u003e. It is engineered for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability process control systems\u003c\/strong\u003e, providing vibration-resistant and stable electrical termination for critical control loops.\u003c\/p\u003e\n\u003cp\u003eThe module’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-redundant connection architecture\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eensures continuous signal transmission. If one wiring path fails, the secondary path maintains communication integrity, making it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical industrial automation environments\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as power generation and petrochemical plants.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATA4D-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eDual-redundant pressure clamp terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eFIO system signal termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 × 20.3 × 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDual-redundant wiring paths improve\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efault tolerance and system availability\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure clamp design maintains\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003egas-tight, vibration-resistant connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReduces maintenance requirements compared to traditional screw terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density cabinet wiring configurations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does dual-redundancy work?\u003c\/strong\u003e\u003cbr\u003eThe terminal block provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eduplicated signal pathways\u003c\/strong\u003e, allowing backup wiring configurations so that signal acquisition continues if one path is mechanically compromised.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it suitable for high-density wiring?\u003c\/strong\u003e\u003cbr\u003eYes. The compact design allows dense wiring layouts while maintaining\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eproper thermal management and accessibility\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einside FIO cabinets.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746739892476,"sku":"ATA4D-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ATA4D-001.jpg?v=1772780844"},{"product_id":"yokogawa-ata4s-00-pressure-clamp-terminal-block","title":"Yokogawa ATA4S-00 Pressure Clamp Terminal Block","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATA4S-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure clamp terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by Yokogawa Electric Corporation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Instrument Platform (FIO)\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esecure and vibration-resistant electrical termination\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor field signal wiring in industrial control systems.\u003c\/p\u003e\n\u003cp\u003eThe module uses a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003espring-loaded pressure clamp mechanism\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain constant contact force on conductors, ensuring stable signal transmission even under\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal cycling and mechanical vibration\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econditions. It is commonly used to improve wiring reliability and reduce maintenance requirements in industrial automation cabinets.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATA4S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eIndustrial signal wiring clamp mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm × 20.3 cm × 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication and Installation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUsed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtrol cabinet signal termination\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor field instrumentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003etool-assisted rapid wiring\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor faster commissioning\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequires\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eproper wire gauge matching\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto maintain electrical and mechanical reliability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does pressure clamp wiring improve reliability?\u003c\/strong\u003e\u003cbr\u003ePressure clamps maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econstant spring force\u003c\/strong\u003e, reducing issues caused by vibration or thermal expansion compared to screw terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all FIO modules?\u003c\/strong\u003e\u003cbr\u003eNo. It is designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003especific Yokogawa FIO platform applications\u003c\/strong\u003e. Always verify compatibility with your specific I\/O module.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746740285692,"sku":"ATA4S-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ATA4S-00-S2.jpg?v=1772785277"},{"product_id":"yokogawa-atr8d-00-pressure-clamp-terminal-block","title":"Yokogawa ATR8D-00 Pressure Clamp Terminal Block","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATR8D-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edual-row pressure clamp terminal block\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edeveloped by Yokogawa Electric Corporation for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Instrument Platform (FIO)\u003c\/strong\u003e. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e12 isolated RTD signal channels\u003c\/strong\u003e, delivering stable and vibration-resistant wiring connections between field sensors and control system input modules.\u003c\/p\u003e\n\u003cp\u003eThe module is optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-density control cabinet installations\u003c\/strong\u003e, helping maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esignal accuracy and long-term connection stability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor temperature measurement applications. It is typically used with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAAR181 RTD input modules\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto simplify field wiring architecture.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATR8D-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Module\u003c\/td\u003e\n\u003ctd\u003eAAR181 RTD Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e12 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eDual-row pressure clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e65.6 mm × 72 mm × 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication and Integration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTD temperature measurement loops\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure clamp design prevents wire loosening due to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal expansion or vibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides reliable signal transmission in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial process control environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan ATR8D-00 be used for non-RTD signals?\u003c\/strong\u003e\u003cbr\u003eNo. The module is optimized specifically for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTD input wiring\u003c\/strong\u003e. Using it with incompatible signal types may cause measurement errors or hardware damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between -0 and -1 variants?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-0\u003c\/strong\u003e: Standard version without surge protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e-1\u003c\/strong\u003e: Includes integrated surge protection to guard against transient voltage spikes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746740383996,"sku":"ATR8D-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ATA4D-001.jpg?v=1772780844"},{"product_id":"yokogawa-atr8s-00-rtd-input-terminal-block","title":"Yokogawa ATR8S-00 RTD Input Terminal Block","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATR8S-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision terminal block interface developed by Yokogawa Electric Corporation for use within the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eField Instrument Platform (FIO)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eecosystem. It is specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eRTD sensor signal wiring\u003c\/strong\u003e, providing stable and vibration-resistant electrical connections between field instruments and control system input modules.\u003c\/p\u003e\n\u003cp\u003eThe module uses\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epressure clamp connection technology\u003c\/strong\u003e, which improves long-term signal stability by reducing the risk of wire loosening caused by vibration or thermal expansion. This makes it suitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecritical temperature monitoring applications\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein industrial process control environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATR8S-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Capacity\u003c\/td\u003e\n\u003ctd\u003e8 RTD input terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003ePolyamide 6 (PA6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eHigh-density panel installation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiring Marking\u003c\/td\u003e\n\u003ctd\u003eIntegrated terminal identification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Reliability\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePressure clamp design prevents terminal loosening in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-vibration industrial environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintains stable RTD loop resistance to reduce temperature measurement drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous process control systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring high signal accuracy\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the ATR8S-00 suitable for high-vibration installations?\u003c\/strong\u003e\u003cbr\u003eYes. The pressure clamp mechanism provides stronger mechanical stability than traditional screw terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat wire sizes are supported?\u003c\/strong\u003e\u003cbr\u003eThe terminal block supports standard RTD wiring gauges. Always verify wiring diagrams for specific project requirements.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746740646140,"sku":"ATR8S-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ATR8S-00.jpg?v=1772780842"},{"product_id":"atk4a-00-s1-yokogawa-ks-cable-interface-adapter","title":"ATK4A-00 S1 Yokogawa KS Cable Interface Adapter","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATK4A-00 S1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a signal interface adapter developed by Yokogawa Electric Corporation. It is designed to bridge connections between control system output modules and field terminal boards using\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKS cable wiring\u003c\/strong\u003e, enabling fast and reliable signal transmission in industrial process control systems.\u003c\/p\u003e\n\u003cp\u003eThis adapter is primarily used to connect to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D terminal boards\u003c\/strong\u003e, helping reduce wiring complexity while maintaining high signal integrity. It is commonly deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART-compatible analog output systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewithin high-availability process control environments such as petrochemical and power plant automation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATK4A-00 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Type\u003c\/td\u003e\n\u003ctd\u003eKS Cable Terminal Block Adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Board\u003c\/td\u003e\n\u003ctd\u003eAEA4D Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAnalog output signal distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Role\u003c\/td\u003e\n\u003ctd\u003ePassive signal interface adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSimplifies wiring between controller outputs and field terminals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImproves mechanical stability of signal connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports high-reliability process control architectures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHART-enabled analog instrumentation systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the ATK4A-00 S1 provide analog output signals directly?\u003c\/strong\u003e\u003cbr\u003eNo. It is a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epassive interface adapter\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethat transfers signals from output modules to terminal boards via KS cabling.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with all Yokogawa terminal boards?\u003c\/strong\u003e\u003cbr\u003eNo. It is specifically designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAEA4D terminal board series\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eintegration. Always verify wiring diagrams before installation.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746741170428,"sku":"ATK4A-00 S1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ATK4A-00_S11.jpg?v=1772780843"},{"product_id":"yokogawa-sai143-h03-analog-input-module","title":"Yokogawa SAI143-H03 Analog Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSAI143-H03\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-precision analog input module developed by Yokogawa Electric Corporation for use in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edistributed control systems. It is designed to accurately convert analog field signals into digital data for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh-reliability process automation and control applications\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe module features a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ecompact industrial design\u003c\/strong\u003e, optimizing control cabinet space while maintaining high signal integrity and stable performance. It is commonly used in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical industrial sectors\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esuch as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epetrochemical processing, power generation, and water treatment control systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSAI143-H03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Systems\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP, CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm × 20.3 cm × 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Reliability\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emission-critical process control environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehigh noise immunity and stable signal acquisition\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003econtinuous industrial operations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequiring high availability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the SAI143-H03 hot-swappable?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eonline replacement\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewhen installed in a compatible Yokogawa node, allowing maintenance without shutting down the control process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input signals does it support?\u003c\/strong\u003e\u003cbr\u003eThe module is designed to connect with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estandard analog field transmitters\u003c\/strong\u003e. Specific current or voltage ranges depend on system configuration and hardware revision.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746741563644,"sku":"SAI143-H03","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SAI143-H03.jpg?v=1772783917"},{"product_id":"yokogawa-amm32-digital-input-module","title":"Yokogawa AMM32 Digital Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM32 (AMM32 S3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance digital input interface module developed by Yokogawa Electric Corporation for integration within industrial automation and distributed I\/O architectures. It is designed to acquire and monitor discrete (binary) field signals from devices such as limit switches, proximity sensors, push buttons, and auxiliary contact outputs.\u003c\/p\u003e\n\u003cp\u003eOptimized for high-density control cabinets, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM32 S3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides reliable signal acquisition for both new installations and legacy retrofits. Its rugged mechanical construction and wide operating temperature range ensure dependable operation in demanding industrial environments.\u003c\/p\u003e\n\u003cp\u003eThe module communicates using an industry-standard RS-485 Modbus RTU interface, enabling high-speed data transmission to supervisory controllers while minimizing latency in mission-critical logic execution. This makes it particularly suitable for distributed control and remote I\/O applications where durability and compactness are essential.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Designation\u003c\/td\u003e\n\u003ctd\u003eAMM32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Capacity\u003c\/td\u003e\n\u003ctd\u003e16 Digital Input Points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eDry contact or voltage-sensing discrete inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eRS-485 Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Protection\u003c\/td\u003e\n\u003ctd\u003eIP65 (front face, panel-mounted)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to +70°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e170 mm × 95 mm × 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM32 (AMM32 S3)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing and assembly lines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower and energy infrastructure\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTypical applications include monitoring pump run\/stop status, valve position feedback, alarm contacts, and emergency stop circuits—particularly in wash-down or environmentally exposed installations requiring IP-rated protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the AMM32 S3 compatible with third-party Modbus masters?\u003c\/strong\u003e\u003cbr\u003eYes. Because it uses the standard RS-485 Modbus RTU protocol, the module can integrate with most PLC, DCS, or SCADA systems that support Modbus RTU communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the IP65 rating apply to?\u003c\/strong\u003e\u003cbr\u003eThe IP65 protection rating applies specifically to the front panel when properly installed in a panel-mounted configuration. It protects against dust ingress and low-pressure water jets, making it suitable for food \u0026amp; beverage, outdoor, or wash-down environments.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746754474236,"sku":"AMM32","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM12.jpg?v=1772435090"},{"product_id":"yokogawa-amm42-centum-cs-3000-analog-input-multiplexer","title":"Yokogawa AMM42 CENTUM CS 3000 Analog Input Multiplexer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM42\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog input multiplexer module engineered for the CENTUM CS 3000 distributed control system platform by Yokogawa Electric Corporation. It functions as a signal aggregation interface, consolidating multiple field analog inputs into a streamlined controller channel to optimize I\/O nest utilization.\u003c\/p\u003e\n\u003cp\u003eBy multiplexing several process signals through a single interface, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM42\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces hardware footprint while maintaining the data integrity required for industrial process control. It incorporates robust signal conditioning and galvanic isolation to protect the system backplane from field-side electrical disturbances.\u003c\/p\u003e\n\u003cp\u003eDesigned for high-density installations, the module is particularly suitable for monitoring non-critical process variables where efficient integration is prioritized. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM42\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports hot-swapping, allowing maintenance or replacement without requiring a full DCS shutdown.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Model\u003c\/td\u003e\n\u003ctd\u003eAMM42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Series\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 3000 \/ CS 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eMulti-channel Analog Input (Multiplexed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Compatibility\u003c\/td\u003e\n\u003ctd\u003e1–5 V DC or 4–20 mA (via external shunt resistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system electrical isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eStandard Yokogawa I\/O nest compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 cm × 7.6 cm × 25.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM42\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production and refining facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical processing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal and combined-cycle power generation stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is particularly effective for clustered monitoring of auxiliary temperatures, tank levels, and pressure transmitters, helping reduce total rack count and cabinet space in large-scale control rooms.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the AMM42 handle current signals if it is voltage-based?\u003c\/strong\u003e\u003cbr\u003eThe module typically measures voltage inputs. For standard 4–20 mA process loops, a precision 250 Ω resistor is installed at the terminal board to convert the current signal into a 1–5 V DC voltage input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the AMM42 compatible with the newer CENTUM VP series?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM42\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewas primarily developed for the CENTUM CS 3000 platform. While certain legacy modules may be supported via migration or interface kits, compatibility with specific CENTUM VP revisions and I\/O nests should be verified prior to integration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746754703612,"sku":"AMM42","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM42.jpg?v=1772435089"},{"product_id":"yokogawa-amm12-centum-vp-voltage-input-multiplexer","title":"Yokogawa AMM12 CENTUM VP Voltage Input Multiplexer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density voltage input multiplexer engineered for the CENTUM distributed control system (DCS) platform by Yokogawa Electric Corporation. It functions as an interface module that consolidates multiple analog voltage signals into a streamlined data stream for the field control station.\u003c\/p\u003e\n\u003cp\u003eThrough advanced multiplexing circuitry, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignificantly reduces I\/O nest hardware footprint, making it well suited for complex plant architectures with extensive monitoring points. Designed for mission-critical environments, the module preserves signal integrity via strong common-mode rejection and precise analog-to-digital conversion.\u003c\/p\u003e\n\u003cp\u003eThe AMM12 is fully\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ehot-swappable\u003c\/strong\u003e, allowing maintenance or system expansion without interrupting the control loop, thereby supporting high plant availability and operational continuity.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Series\u003c\/td\u003e\n\u003ctd\u003eCENTUM VP \/ CENTUM CS 3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eMultiplexed Analog Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003eTypically 1–5 V DC (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e≥ 1 MΩ (power-on state)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full scale (reference dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC galvanic isolation (input-to-system bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Period\u003c\/td\u003e\n\u003ctd\u003eSynchronized with DCS controller scan cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 cm × 22.9 cm × 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely deployed in heavy industrial sectors, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical refining\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLNG processing facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge-scale thermal and combined-cycle power generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is particularly effective for monitoring non-critical secondary variables—such as auxiliary tank levels, voltage transmitters, and peripheral instrumentation—where high-density signal aggregation optimizes cabinet space and reduces overall I\/O cost per point.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the AMM12 be used in a redundant configuration?\u003c\/strong\u003e\u003cbr\u003eYes. The module supports dual-redundant I\/O nest configurations, ensuring continued signal acquisition in the event of a single module failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support current signals directly?\u003c\/strong\u003e\u003cbr\u003eNo. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM12\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a voltage-input module. For 4–20 mA current loops, a precision shunt resistor (typically 250 Ω) must be installed at the terminal board to convert the signal to a 1–5 V DC input range.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746754801916,"sku":"AMM12","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM12.jpg?v=1772435090"},{"product_id":"yokogawa-amm22-centum-cs-3000-multiplexer-input-module","title":"Yokogawa AMM22 CENTUM CS 3000 Multiplexer Input Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22 (S1–S4)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-density analog multiplexer module designed for integration within the CENTUM distributed control system platform by Yokogawa Electric Corporation. This module functions as a signal aggregation interface, consolidating multiple analog process variables into a single controller input, thereby reducing cabinet space requirements and field wiring complexity in large-scale industrial installations.\u003c\/p\u003e\n\u003cp\u003eEngineered for precision measurement and thermal stability, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprocesses low-level analog signals with high resolution and stable scan performance. It is commonly deployed in applications where numerous transmitters—such as pressure, flow, or level devices—must be monitored simultaneously without compromising signal accuracy. Its compact mechanical footprint and low power consumption make it well suited for high-density I\/O configurations.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eYokogawa Electric Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eMulti-channel Analog Multiplexer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eCENTUM CS 3000 \/ CS 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003eConfigurable for 1–5 V or 4–20 mA process loops\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-system galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e12.7 cm × 2.5 cm × 20.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in oil \u0026amp; gas refineries, chemical processing plants, and power generation facilities. It is particularly suited for centralized monitoring of non-critical process variables, where high-density multiplexing provides a cost-effective alternative to individual analog input modules while maintaining reliable data acquisition performance.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the AMM22 support redundant configurations?\u003c\/strong\u003e\u003cbr\u003eYes. When installed in a compatible Yokogawa Nest or I\/O rack, the module can be configured in a dual-redundant architecture to ensure continuous signal acquisition in the event of a single module failure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the primary benefit of using a multiplexer instead of a standard analog input module?\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincreases the number of input channels per rack slot, reducing cost per I\/O point and minimizing overall cabinet space requirements without significantly impacting measurement accuracy for non-critical loops.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746754932988,"sku":"AMM22","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM22C1.jpg?v=1772263127"},{"product_id":"amm22m-yokogawa-input-multiplexer-module","title":"AMM22M Yokogawa Input Multiplexer Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(part number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22M\u003c\/strong\u003e) is a high-precision analog signal acquisition module specifically engineered for Yokogawa’s\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM VP\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCENTUM CS 3000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDistributed Control Systems (DCS). This module serves as a specialized millivolt (mV) input multiplexer, designed to aggregate\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 low-level DC voltage signals\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003einto a single system node. Manufactured in France to rigorous European industrial standards, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a critical component for processes requiring the monitoring of high-density, low-voltage sensors such as specialized thermocouples or shunt-based transducers.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 independent, high-isolation millivolt input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptimized for low-level DC voltage (mV spectrum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuperior channel-to-channel and channel-to-ground galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D Processing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution sampling for precise process variable mapping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully compatible with Yokogawa RIO and FIO bus architectures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard chassis or panel mount within I\/O module nests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 mm x 120 mm x 80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eOperational Application\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis frequently deployed in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emetallurgical\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003echemical\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003epower generation\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efacilities where high concentrations of low-voltage sensors are located. By utilizing advanced multiplexing logic, the module samples all\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 field inputs\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esequentially, ensuring that the control system receives updated data with minimal scan-time latency. Its robust French-manufactured housing provides excellent protection against\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eelectromagnetic interference (EMI)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ethermal drift\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ\u003c\/strong\u003e: How does the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ediffer from the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22C\u003c\/strong\u003e?\u003cbr\u003e\u003cstrong\u003eA\u003c\/strong\u003e: While both are\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16-channel mV multiplexers\u003c\/strong\u003e, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM22M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specific regional variant (manufactured in France) that may feature different terminal connection styles or internal components optimized for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEuropean industrial compliance standards\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompared to the standard C-series.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746755358972,"sku":"AMM22M","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM32C2.jpg?v=1772263127"},{"product_id":"thermocouple-mv-analog-input-module-amm25c-yokogawa","title":"Thermocouple\/mV Analog Input Module AMM25C Yokogawa","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe AMM25C (incorporating part number AMM25C) is a specialized high-performance analog input multiplexer engineered for the Yokogawa CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This module is specifically designed to interface with thermocouples and low-level millivolt (mV) DC signals. Featuring an integrated Reference Junction Compensation (RJC) input port, it provides laboratory-grade temperature measurement accuracy within rugged industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 isolated input points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC Voltage (-10 to 10 V), Millivolt DC (-100 to 100 mV), and Thermocouples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Precision\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-fidelity accuracy of ±40 µV for mV inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThermal Stability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSuperior drift control with ±80 µV per 10°C ambient change\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBurnout Detection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable sensor-break logic (UP, DOWN, or OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in RJC connector for thermocouple linearity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUtilizes the KS1 system cable for high-speed bus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFully isolated inputs to eliminate ground loops and electromagnetic interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTerminal block style S1 with secure M4 screw terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 cm (H) x 22.9 cm (W) x 7.6 cm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Performance\u003c\/h3\u003e\n\u003cp\u003eThe AMM25C serves as a critical data acquisition node for processes where precise thermal tracking is paramount—such as furnace control, chemical reactor monitoring, and glass manufacturing. By multiplexing 15 channels through a high-speed switching matrix, it reduces the physical hardware footprint while maintaining the signal integrity required for mission-critical automation loops. Its robust mechanical design ensures that connections remain secure even in high-vibration environments.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ\u003c\/strong\u003e: Does the AMM25C require an external RJC sensor for thermocouple measurements?\u003cbr\u003e\u003cstrong\u003eA\u003c\/strong\u003e: The module includes a dedicated RJC input port; however, for accurate compensation, it must be paired with the appropriate Yokogawa terminal board (such as the TEV or similar series) that houses the actual cold-junction sensing element.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746755522812,"sku":"AMM25C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM25C2.jpg?v=1772263127"},{"product_id":"amm32c-yokogawa-rtd-input-multiplexer-module","title":"AMM32C Yokogawa RTD Input Multiplexer Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe AMM32C (incorporating part number AMM32C) is a high-density temperature acquisition module engineered for Yokogawa’s CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This millivolt-level multiplexer is designed to consolidate up to 32 Resistance Temperature Detector (RTD) signals, providing a streamlined and cost-effective interface for large-scale thermal monitoring. It is primarily utilized in power plants, refineries, and chemical processing facilities to track bearing temperatures, motor windings, and reactor profiles.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 isolated RTD input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports Pt100, JPt100, and other standard 2-wire or 3-wire RTD configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLead Wire Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eActive compensation for 3-wire setups to maintain measurement integrity over long distances\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInterconnect Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUtilizes the KS8 dedicated connecting cable for system bus integration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≥100 MΩ (measured at 500V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500V AC withstanding voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperational Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 50°C (32°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Reliability\u003c\/h3\u003e\n\u003cp\u003eThe AMM32C is built for mission-critical reliability, featuring high-grade galvanic isolation that protects the DCS backplane from field-side electrical surges. Its multiplexing architecture allows the system to scan 32 temperature points with high precision, reporting data directly to the controller with minimal signal degradation. The module is treated with industrial-grade protection to ensure consistent performance in high-humidity and electrically noisy environments.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ\u003c\/strong\u003e: Does the AMM32C require a specific terminal board?\u003cbr\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, the AMM32C typically interfaces with a field termination board (such as the AEDV series) via the KS8 cable. This allows for organized field wiring and provides the necessary cold-junction or lead-wire compensation points.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746755653884,"sku":"AMM32C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM32C2.jpg?v=1772263127"},{"product_id":"amm22c-yokogawa-input-multiplexer-module","title":"AMM22C Yokogawa Input Multiplexer Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe AMM22C (incorporating part number AMM22C) is a high-precision analog signal acquisition component engineered for the Yokogawa CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This module serves as a specialized millivolt (mV) input multiplexer, designed to aggregate low-level voltage signals from various field sensors—such as thermocouples (via external CJC) or specialized shunt-based transducers—into a single system processing node. It is a critical component for industrial environments requiring high-density, low-voltage data acquisition with superior signal stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 high-isolation millivolt input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptimized for low-level DC voltage (millivolt spectrum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog-to-Digital Conversion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution A\/D processing for fine signal granularity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard high-density system connector for secure field-to-bus coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRobust panel or chassis mount form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e 1.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSeamlessly integrates with Yokogawa RIO and FIO bus structures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Characteristics\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel galvanic isolation to prevent ground loop interference\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Resilience\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesigned for continuous 24\/7 operation in industrial control rooms and satellite rack rooms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDiagnostic Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated module status monitoring via the DCS operator station\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Implementation\u003c\/h3\u003e\n\u003cp\u003eThe AMM22C utilizes high-speed multiplexing logic to sample 16 independent field inputs sequentially, ensuring that the control system receives updated process data with minimal scan-time latency. This module is frequently deployed in metallurgical, chemical, and power generation facilities where multiple low-voltage sensors are concentrated in a single area, providing a cost-effective alternative to individual isolated transmitters.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ\u003c\/strong\u003e: Can the AMM22C be used directly with Thermocouples?\u003cbr\u003e\u003cstrong\u003eA\u003c\/strong\u003e: Yes, the AMM22C can process the millivolt signals generated by thermocouples; however, for accurate temperature readings, cold-junction compensation (CJC) must be managed either through a compatible terminal board or within the DCS software configuration.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746755719420,"sku":"AMM22C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM22C1.jpg?v=1772263127"},{"product_id":"amm12t-yokogawa-voltage-input-multiplexer","title":"AMM12T Yokogawa Voltage Input Multiplexer","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe AMM12T (incorporating part number AMM12T) is a high-density analog data acquisition component designed for the Yokogawa CENTUM VP and CENTUM CS 3000 Distributed Control Systems (DCS). This module serves as a specialized voltage input multiplexer, allowing for the efficient consolidation of multiple low-level voltage signals into a single system node. It is engineered for industrial environments where high-accuracy monitoring of secondary process variables or auxiliary sensor data is required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 isolated voltage input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Signal Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConfigurable for standard DC voltage ranges (typically -10V to +10V or 1-5V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSignal Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e250V AC channel-to-channel and channel-to-ground isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16-bit high-precision analog-to-digital conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigh-impedance design (\u0026gt;1 MΩ) to prevent signal loading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNative integration with Yokogawa RIO (Remote I\/O) bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.0 cm x 7.0 cm x 21.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.46 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Performance\u003c\/h3\u003e\n\u003cp\u003eThe AMM12T utilizes a high-speed multiplexing circuit to scan 16 field inputs sequentially, providing updated process variables to the controller with minimal latency. Its robust isolation barriers protect the DCS backplane from field-side electrical surges and ground loops, making it an ideal choice for power generation and chemical processing facilities where electrical noise is prevalent.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ\u003c\/strong\u003e: Can the AMM12T be used for 4-20mA signals?\u003cbr\u003e\u003cstrong\u003eA\u003c\/strong\u003e: While primarily a voltage input module, the AMM12T can monitor 4-20mA current loops if a high-precision shunt resistor (typically 250 Ohms) is installed at the terminal board to convert the current into a 1-5V DC signal.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746755817724,"sku":"AMM12T","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM12T2.jpg?v=1772263127"},{"product_id":"amm32t-yokogawa-rtd-input-multiplexer-module","title":"AMM32T Yokogawa RTD Input Multiplexer Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe AMM32T (incorporating part number AMM32T) is a high-density temperature acquisition component designed for the Yokogawa CENTUM VP and CENTUM CS distributed control systems (DCS). This multiplexer module provides 32 isolated measurement channels, allowing for the consolidation of a large volume of Resistance Temperature Detector (RTD) signals into a single I\/O footprint. It is engineered for industrial process monitoring, specifically where high-precision thermal tracking of reactor beds, bearing temperatures, or motor windings is required.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChannel Density\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32 fully isolated RTD input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2 MΩ per channel to ensure signal linearity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensor Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupports Pt100 (IEC\/DIN), Pt1000, and JPt100 (JIS) standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Configuration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompatible with 3-wire RTD setups for lead-wire resistance compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Integration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNative support for Yokogawa CENTUM VP and CENTUM CS 3000 controllers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExpansion Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesigned to operate alongside the AMT16R 16-channel expansion units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12.7 cm x 10.2 cm x 22.9 cm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.8 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOperational Advantages\u003c\/h3\u003e\n\u003cp\u003eThe AMM32T utilizes advanced multiplexing circuitry to scan 32 field sensors rapidly without compromising accuracy. By centralizing the temperature inputs, it significantly reduces the cost per point for large-scale installations. Its robust design is built for 24\/7 continuous operation in harsh industrial environments, featuring diagnostic capabilities that report sensor burnout or wiring faults directly to the DCS operator interface.\u003c\/p\u003e\n\u003ch3\u003eEngineering FAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ\u003c\/strong\u003e: Does the AMM32T support 4-wire RTD sensors for ultra-high precision?\u003cbr\u003e\u003cstrong\u003eA\u003c\/strong\u003e: The standard AMM32T configuration is optimized for 3-wire RTD inputs, which provides sufficient lead-wire compensation for most industrial distances. For 4-wire requirements, verify the terminal block configuration and DCS software scaling parameters.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746755916028,"sku":"AMM32T","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM32T1.jpg?v=1772263127"},{"product_id":"yokogawa-amm52-s4-analog-input-output-processor-module","title":"Yokogawa AMM52 S4 Analog Input\/Output Processor Module","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM52 S4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance analog processor module engineered by Yokogawa for the Centum distributed control system. This module processes multiple analog signal streams, converting field instrumentation data into actionable logic for the DCS. Recognized for high-speed throughput and thermal stability, the AMM52 S4 maintains critical process variables with minimal signal drift in demanding industrial environments.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDetailed Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Identification\u003c\/td\u003e\n\u003ctd\u003eAMM52 S4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eAnalog Signal Processing \/ I\/O Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eMulti-channel Analog Input\/Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Revision\u003c\/td\u003e\n\u003ctd\u003eS4 (Specific circuitry and firmware)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Support\u003c\/td\u003e\n\u003ctd\u003eStandard industrial current (4–20 mA) and voltage ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Integration\u003c\/td\u003e\n\u003ctd\u003eCompatible with Yokogawa Field Control Stations (FCS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Profile\u003c\/td\u003e\n\u003ctd\u003eVertical slot-in for Yokogawa nest assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Features\u003c\/td\u003e\n\u003ctd\u003eOn-board hardware integrity and signal fault monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Dimensions\u003c\/td\u003e\n\u003ctd\u003e6.3 × 6.3 × 14.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eIndustrial Application Scenarios\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAMM52 S4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHydrocarbon processing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced manufacturing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is optimized for analog loops associated with control valves, temperature transmitters, and pressure transducers. Its compact design and low power consumption make it ideal for high-density cabinet installations where heat management is critical.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the 'S4' suffix signify?\u003c\/strong\u003e\u003cbr\u003eThe 'S4' indicates the hardware revision. Matching this suffix is essential for replacement to ensure identical signal impedance and timing within the existing DCS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this module considered a standalone PLC?\u003c\/strong\u003e\u003cbr\u003eNo. The AMM52 S4 functions as a specialized analog processor module within the Yokogawa Centum DCS, not as a standalone PLC.\u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":48746758111484,"sku":"AMM52 S4","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AMM52-S42.jpg?v=1770948453"}],"url":"https:\/\/www.electronicplc.com\/collections\/yokogawa-i-o-modules.oembed?page=2","provider":"Electronic PLC","version":"1.0","type":"link"}