{"product_id":"146031-01-bently-nevada-transient-data-interface-i-o-module-1","title":"Bently Nevada 136188-02 Ethernet\/RS485 Modbus I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 136188-02 is an Ethernet\/RS485 Modbus I\/O module designed for integration with the 3500\/92 Communication Gateway within the Bently Nevada 3500 Series Machinery Health Monitoring System. This module acts as the critical interface between the 3500 rack and external automation systems, facilitating real-time data exchange for condition monitoring, predictive maintenance, and system optimization. It provides both Ethernet TCP\/IP connectivity and serial RS485 communication, ensuring compatibility with modern control systems and legacy serial Modbus networks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEthernet TCP\/IP communication via RJ45 connector for 10BASE-T networks.\u003c\/li\u003e\n\u003cli\u003eSerial RS485 communication interface for Modbus RTU protocols.\u003c\/li\u003e\n\u003cli\u003eConfigurable Modbus Register Utility for flexible data mapping.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED indicators for OK and TX\/RX status monitoring.\u003c\/li\u003e\n\u003cli\u003eField-upgradable firmware support via 126M4118-01 kit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eNuclear, thermal, and hydropower plant machinery monitoring.\u003c\/li\u003e\n\u003cli\u003eTurbine bearing and stator winding temperature and vibration monitoring.\u003c\/li\u003e\n\u003cli\u003ePump and motor condition assessment.\u003c\/li\u003e\n\u003cli\u003eGearbox lubrication and internal friction detection.\u003c\/li\u003e\n\u003cli\u003eContinuous protection for industrial fans, blowers, and extruders.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e136188-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet (TCP\/IP) \/ Serial (RS485)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 degC to +65 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.6 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC +\/- 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3500 rack is powered down before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eUse a standard 10BASE-T (or better) shielded Category 5 cable for Ethernet connections.\u003c\/li\u003e\n\u003cli\u003eFor RS485 serial communications, ensure proper grounding of the communication lines to minimize noise interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eThe 136188-02 is a rear-inserting I\/O module; it requires the 136180-01 front-inserting Communication Gateway module to operate as a complete 3500\/92 system.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to protect sensitive internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the 136188-02?\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 136188-02 is an Ethernet\/RS485 Modbus I\/O module designed for the 3500\/92 Communication Gateway.\u003c\/p\u003e\u003ch3\u003eWhat is the core function of the 136188-02 module?\u003c\/h3\u003e\u003cp\u003eIt transmits real-time monitoring statuses, direct vibration levels, and gap values from the 3500 rack to external platforms.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between the 136188-01 and 136188-02 variants?\u003c\/h3\u003e\u003cp\u003eThe 136188-01 variant utilizes RS232 serial communication, whereas the 136188-02 model uses RS485 physical layer communication alongside the standard Ethernet connection.\u003c\/p\u003e\u003ch3\u003eIs this module a full standalone gateway?\u003c\/h3\u003e\u003cp\u003eNo, the 136188-02 is a rear-inserting physical I\/O module. It must be paired with the front-inserting 136180-01 main Communication Gateway module to function.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50643881689340,"sku":"136188-02","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_52721eeb-17c1-4c3c-9080-80a8ee2d9ebf.jpg?v=1784951787","url":"https:\/\/www.electronicplc.com\/es\/products\/146031-01-bently-nevada-transient-data-interface-i-o-module-1","provider":"Electronic PLC","version":"1.0","type":"link"}