{"product_id":"2711-k5a16l3-panelview-550-standard-hmi-module","title":"Allen-Bradley 2711-K5A16L3 PanelView 550 Standard HMI Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe 2711-K5A16L3 functions as a highly specialized industrial visualization station within the Allen-Bradley PanelView Standard 550 operator interface series. This terminal delivers deterministic, real-time peripheral control and machine-level diagnostics when integrated with a programmable logic controller. Purpose-built for high-availability industrial configurations—such as waste management facilities, material handling distribution centers, and secondary chemical processing loops—the hardware replaces mechanical pilot lights and control switches. By executing graphic rendering matrices and local alarm banner generation on its dedicated processor, the terminal limits backplane bus load and significantly reduces network-induced system downtime.\u003c\/p\u003e\u003ch3\u003eData Links and Communications Layout\u003c\/h3\u003e\u003cp\u003eThe internal communication layer leverages a dual-channel RS-232 serial architecture to handle concurrent control link monitoring and printing processes. The primary RS-232 serial interface utilizes native Allen-Bradley DF1 point-to-point protocol layers, ensuring a low-latency, noise-immune pipeline for active register mapping and instruction updates. The secondary RS-232 configuration provides an isolated channel dedicated to hardcopy printing utilities or application firmware transfers via an external PC link. Memory storage limits are flexible through an onboard PCMCIA slot, accommodating standard memory flash cards from 2 MB to 32 MB to handle recipe storage, text font tables, and complex automation graphics.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRugged membrane keypad with 10 assignable function keys (F1-F10), numeric, and navigation panels.\u003c\/li\u003e\n\u003cli\u003eMonochrome transflective LCD blue mode display with solid-state LED backlight.\u003c\/li\u003e\n\u003cli\u003eField-serviceable backlight (Part 2711-NL1) with 100,000-hour rating.\u003c\/li\u003e\n\u003cli\u003eIntegrated battery-backed real-time clock (RTC) for sequence-of-events logging.\u003c\/li\u003e\n\u003cli\u003eDual RS-232 serial ports for DF1 communication and printing\/firmware updates.\u003c\/li\u003e\n\u003cli\u003ePCMCIA slot for expandable memory storage.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K5A16L3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.5 inch diagonal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e256 x 128 Pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication RAM\u003c\/td\u003e\n\u003ctd\u003e170 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNon-volatile Storage\u003c\/td\u003e\n\u003ctd\u003e240 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 12, 13, 4X, IP54, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the panel cutout is clean and free of debris before mounting the terminal.\u003c\/li\u003e\n\u003cli\u003eUse the provided mounting clips to secure the unit to the enclosure, ensuring an even seal to maintain NEMA\/IP ratings.\u003c\/li\u003e\n\u003cli\u003eVerify that the input power supply is within the 85-264 VAC range before applying power.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables away from high-voltage power lines to prevent EMI interference.\u003c\/li\u003e\n\u003cli\u003ePower down the unit before inserting or removing PCMCIA memory cards.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the rear of the unit to maintain operating temperature limits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary communication protocol for this HMI?\u003c\/h3\u003e\u003cp\u003eThe 2711-K5A16L3 primarily utilizes the Allen-Bradley DF1 point-to-point protocol via its RS-232 serial interface.\u003c\/p\u003e\u003ch3\u003eIs the backlight replaceable?\u003c\/h3\u003e\u003cp\u003eYes, the LED backlight is field-serviceable and can be replaced using the 2711-NL1 replacement part.\u003c\/p\u003e\u003ch3\u003eWhat is the purpose of the PCMCIA slot?\u003c\/h3\u003e\u003cp\u003eThe PCMCIA slot allows for the use of flash memory cards (2 MB to 32 MB) to store application recipes, custom text fonts, and complex graphic files.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":50909795549436,"sku":"2711-K5A16L3","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_009e6967-71b4-49a3-ba76-4f5aeabd5ff4.jpg?v=1785629862","url":"https:\/\/www.electronicplc.com\/es\/products\/2711-k5a16l3-panelview-550-standard-hmi-module","provider":"Electronic PLC","version":"1.0","type":"link"}