{"product_id":"3101-triconex-tricon-main-processor-module","title":"Triconex 3101 Tricon Main Processor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Triconex 3101 is a high-performance Main Processor Module designed for the Tricon Triple Modular Redundancy (TMR) safety system. It acts as the primary intelligence unit, managing safety logic, system diagnostics, and I\/O coordination for mission-critical industrial processes. The module is engineered for high-availability applications, including oil and gas refining, chemical processing, and power generation, providing SIL 3 safety integrity by eliminating single points of failure through its redundant architecture.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-processor architecture separating application logic (SX) from I\/O management (IOX).\u003c\/li\u003e\n\u003cli\u003eMotorola MPC860 32-bit RISC processors operating at 50 MHz for both SX and IOX.\u003c\/li\u003e\n\u003cli\u003eTMR synchronization via a 2 Mbps HDLC diagnostic bus.\u003c\/li\u003e\n\u003cli\u003eRobust memory configuration including 16 MB DRAM and 6 MB Flash PROM for the application processor.\u003c\/li\u003e\n\u003cli\u003eDeterministic execution for time-critical safety functions.\u003c\/li\u003e\n\u003cli\u003eComprehensive self-diagnostics and inter-channel synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 3101 module is deployed in safety-instrumented systems (SIS) where continuous operation and high reliability are mandatory. Typical applications include emergency shutdown systems (ESD), burner management systems (BMS), and fire and gas monitoring in hazardous industrial environments.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eTriconex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Processors\u003c\/td\u003e\n\u003ctd\u003eDual Motorola MPC860 (32-bit, 50 MHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory (SX)\u003c\/td\u003e\n\u003ctd\u003e16 MB DRAM, 6 MB Flash PROM, 8 KB NVRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory (IOX)\u003c\/td\u003e\n\u003ctd\u003e16 MB DRAM, 128 KB Shared Memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Voltage\u003c\/td\u003e\n\u003ctd\u003e33 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Power\u003c\/td\u003e\n\u003ctd\u003e8 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Bus\u003c\/td\u003e\n\u003ctd\u003e2 Mbps HDLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the Tricon chassis is powered down before inserting or removing the 3101 module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be seated firmly in the designated processor slots of the Tricon chassis to ensure proper backplane connection.\u003c\/li\u003e\n\u003cli\u003eHandle with care using ESD-safe procedures; the module contains sensitive electronic components.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation within the cabinet to maintain the operating temperature range of 0 to 60 deg C.\u003c\/li\u003e\n\u003cli\u003eVerify that the input power supply is within the 19.2 to 30 VDC range before system startup.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the 3101 module?\u003c\/strong\u003e\u003cbr\u003eThe 3101 is the main processor module for the Tricon TMR system, responsible for executing safety control logic and managing communications between I\/O modules and the system backplane.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module support redundancy?\u003c\/strong\u003e\u003cbr\u003eYes, the 3101 is designed specifically for Triple Modular Redundancy (TMR) configurations, where three processors work in parallel to provide fault-tolerant, fail-safe operation.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":50738670567676,"sku":"3101","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_7d29b75c-1cf9-4f11-9a9c-2e54736a6144.jpg?v=1785380627","url":"https:\/\/www.electronicplc.com\/es\/products\/3101-triconex-tricon-main-processor-module","provider":"Electronic PLC","version":"1.0","type":"link"}