{"product_id":"3bse008510r1-abb-do810-16-channel-digital-output-module","title":"ABB 3BSE008510R1 DO810 Digital Output Module","description":"\u003cp\u003eThe ABB DO810 (3BSE008510R1) is a high-performance 16-channel digital output module designed for the S800 I\/O system. This module provides reliable 24 V d.c. current sourcing outputs, making it an essential component for industrial automation environments requiring precise control over field devices such as relays, contactors, and signaling indicators.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-channel digital output capacity with 24 V d.c. current sourcing.\u003c\/li\u003e\n\u003cli\u003eTwo independently isolated groups of 8 channels, each featuring dedicated process voltage supervision.\u003c\/li\u003e\n\u003cli\u003eRobust protection circuitry including short-circuit, over-voltage, and over-temperature safeguards.\u003c\/li\u003e\n\u003cli\u003eOutput Status Indication LEDs for local diagnostics.\u003c\/li\u003e\n\u003cli\u003eOSP (Output Set to Predetermined state) functionality to ensure system safety during communication loss or watchdog timeouts.\u003c\/li\u003e\n\u003cli\u003eOptical isolation barrier for enhanced signal integrity and noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurner Management Systems (BMS):\u003c\/strong\u003e Sequencing of fuel valves and ignition hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump and Compressor Control:\u003c\/strong\u003e Managing start\/stop logic for motor starters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTurbine Auxiliaries:\u003c\/strong\u003e Controlling hydraulic pumps, cooling fans, and motorized valve actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSubstation Automation:\u003c\/strong\u003e Interfacing with circuit breakers and isolators.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDO810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrder Code\u003c\/td\u003e\n\u003ctd\u003e3BSE008510R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10 to 30 V d.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulebus Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA (+5 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 % (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the I\/O rack.\u003c\/li\u003e\n\u003cli\u003eMount the module in a clean, dry environment within an industrial enclosure to prevent ingress of dust or moisture.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the module to maintain operating temperatures within the specified 0 to +55 degC range.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for field wiring to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding of the S800 I\/O system backplane to ensure reliable operation of the optical isolation and protection circuits.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the DO810 module?\u003c\/h3\u003e\u003cp\u003eThe DO810 acts as a digital interface between the control system and field equipment, converting logical control commands into 24 V d.c. outputs to drive external actuators and indicators.\u003c\/p\u003e\u003ch3\u003eHow does the process voltage supervision work?\u003c\/h3\u003e\u003cp\u003eThe 16 channels are split into two groups of eight. Each group has a dedicated supervision input. If the external process voltage for a group is lost, the module triggers an error signal that is transmitted to the controller via the ModuleBus.\u003c\/p\u003e\u003ch3\u003eWhat happens to the outputs if communication fails?\u003c\/h3\u003e\u003cp\u003eThe module supports OSP (Output Set to Predetermined state). Upon detecting a communication error or a watchdog timeout, the outputs will transition to a predefined safe state, such as all off or holding their last known state, depending on the system configuration.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51213284475132,"sku":"3BSE008510R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a3b20a00-3980-4bff-9e53-51a330a74b4d.jpg?v=1788233306","url":"https:\/\/www.electronicplc.com\/es\/products\/3bse008510r1-abb-do810-16-channel-digital-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}