{"product_id":"abb-advant-ocs-and-advant-800xa-fena-21-3aua0000089108-2-port-ethernet-adapter","title":"ABB FENA-21 3AUA0000089108 2-Port Ethernet Adapter","description":"\u003cp\u003eThe ABB FENA-21 (3AUA0000089108) is a high-performance, 2-port Ethernet adapter module designed for seamless integration of ABB drives into industrial Ethernet networks. Featuring an integrated switch, this module supports daisy-chain and ring topologies, facilitating efficient communication without the need for additional external hardware.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual-port RJ45 connectivity with integrated switch functionality.\u003c\/li\u003e\n\u003cli\u003eSupports multiple industrial protocols: PROFINET IO (RT), EtherNet\/IP, and Modbus\/TCP.\u003c\/li\u003e\n\u003cli\u003eEnables drive control commands including Start, Stop, and Run enable.\u003c\/li\u003e\n\u003cli\u003eSupports motor speed and torque reference feeding.\u003c\/li\u003e\n\u003cli\u003eAllows for reading drive status, actual values, and resetting drive faults.\u003c\/li\u003e\n\u003cli\u003eCompatible with a wide range of ABB drives, including the ACS380, ACS480, ACS580, and ACS880 series.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Control systems for auxiliary and main machinery in large power plants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFood and Beverage:\u003c\/strong\u003e Integration for packaging machinery, filling lines, and conveyor systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomotive:\u003c\/strong\u003e Management of conveyor systems in painting, body, and assembly workshops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Industry:\u003c\/strong\u003e Control of mixing equipment, ventilation fans, and circulating water pumps in chemical and petroleum facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eFENA-21 3AUA0000089108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e≤ 2.5 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003eMax 100 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the drive is powered down and the DC bus is discharged before installing or removing the adapter module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to sensitive electronic components.\u003c\/li\u003e\n\u003cli\u003eInsert the module into the designated option slot on the drive; ensure it is seated firmly and secured with the provided mounting screws.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair (STP) Ethernet cables to minimize electromagnetic interference (EMI) in industrial environments.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables separately from high-voltage power cables to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that the drive firmware supports the FENA-21 module before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary advantage of the FENA-21 over the FENA-11?\u003c\/h3\u003e\u003cp\u003eThe FENA-21 features two Ethernet ports and an integrated switch, allowing for linear (daisy-chain) and ring network topologies, whereas the FENA-11 is limited to a single port.\u003c\/p\u003e\u003ch3\u003eHow are the communication protocols configured?\u003c\/h3\u003e\u003cp\u003eProtocol selection (PROFINET IO, EtherNet\/IP, or Modbus\/TCP) is configured directly through the drive's parameter settings.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with safety functions?\u003c\/h3\u003e\u003cp\u003eYes, the FENA-21 is designed to work in conjunction with drive-based safety modules, such as the FSO-12 or FSO-21, to implement advanced safety protection in industrial applications.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51006473928956,"sku":"FENA-21 3AUA0000089108","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_7d582330-eaa0-42a5-ac86-286419f59110.jpg?v=1787511760","url":"https:\/\/www.electronicplc.com\/es\/products\/abb-advant-ocs-and-advant-800xa-fena-21-3aua0000089108-2-port-ethernet-adapter","provider":"Electronic PLC","version":"1.0","type":"link"}