{"product_id":"abb-ai880a-3bse039293r1-analog-input-hi-s-r-hart-8-ch","title":"ABB 3BSE039293R1 AI880A High Integrity Analog Input Module","description":"\u003cp\u003eThe ABB AI880A (3BSE039293R1) is a high-integrity analog input module designed for the S800 I\/O system. This module is specifically engineered for safety-critical applications, providing 8 channels for current inputs. It is designed to support both single and redundant configurations, ensuring high availability and reliability in demanding industrial environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 channels for 0...20 mA or 4...20 mA unipolar single-ended inputs\u003c\/li\u003e\n\u003cli\u003eCertified for SIL3 safety applications according to IEC 61508\u003c\/li\u003e\n\u003cli\u003eSupports HART pass-through communication\u003c\/li\u003e\n\u003cli\u003e12-bit resolution for precise signal measurement\u003c\/li\u003e\n\u003cli\u003eConfigurable over\/under range limits and alarm limits for field power\u003c\/li\u003e\n\u003cli\u003eCurrent-limited transmitter supply per channel\u003c\/li\u003e\n\u003cli\u003eAdvanced on-board diagnostics for improved system monitoring\u003c\/li\u003e\n\u003cli\u003eIsolated channel group from the ModuleBus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOil and Gas: Offshore drilling platforms and natural gas compression stations\u003c\/li\u003e\n\u003cli\u003eRefining and Petrochemicals: Ethylene cracking, ammonia synthesis, and hazardous chemical storage\u003c\/li\u003e\n\u003cli\u003ePower Generation: Furnace safety monitoring and steam turbine bypass valve control\u003c\/li\u003e\n\u003cli\u003eWater Treatment and Metallurgy: Industrial gas recovery systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eAI880A 3BSE039293R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e0..20 mA, 4..20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ohm (with shunt stick TY801)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Voltage (Non-destructive)\u003c\/td\u003e\n\u003ctd\u003e11 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNMRR (50Hz, 60Hz)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 40 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the module is installed on a compatible Module Termination Unit (TU834, TU844, TU845, or TU854).\u003c\/li\u003e\n\u003cli\u003eAlways power down the system before inserting or removing the module from the I\/O rack to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to protect sensitive internal components.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the I\/O rack and shielding of signal cables to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that field power supply wiring is correctly connected to the termination unit for transmitter excitation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary use of the AI880A?\u003c\/h3\u003e\u003cp\u003eThe AI880A is a high-integrity analog input module used in safety-critical S800 I\/O systems, specifically designed to meet SIL3 requirements for measuring current signals from field transmitters.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with HART communication?\u003c\/h3\u003e\u003cp\u003eYes, the AI880A supports HART pass-through communication, allowing for device configuration and diagnostics through the analog loop.\u003c\/p\u003e\u003ch3\u003eCan this module be used in redundant configurations?\u003c\/h3\u003e\u003cp\u003eYes, the AI880A is designed to support both single and redundant configurations to meet high-availability requirements.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50986499080444,"sku":"3BSE039293R1","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b67b87fe-e2e3-45b2-8d88-8f4399f47625.jpg?v=1786821953","url":"https:\/\/www.electronicplc.com\/es\/products\/abb-ai880a-3bse039293r1-analog-input-hi-s-r-hart-8-ch","provider":"Electronic PLC","version":"1.0","type":"link"}