{"product_id":"abb-drives-fs300r12ke3-agdr-62c-insulated-gate-bipolar-transistor","title":"ABB FS300R12KE3\/AGDR-62C Insulated Gate Bipolar Transistor Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe ABB FS300R12KE3\/AGDR-62C is an integrated power module and gate driver kit, featuring the Infineon EconoPACK+ IGBT module paired with a factory-calibrated ABB AGDR-62C gate driver board. This assembly is specifically engineered for high-performance industrial applications, serving as a critical component in ABB ACS800 series variable frequency drives, including the R7i and R8i frame sizes. It provides reliable power switching and integrated protection for medium-voltage power conversion systems.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntegrated 1200V \/ 300A IGBT power module and gate driver board.\u003c\/li\u003e\n\u003cli\u003eAdvanced protection functions including overcurrent detection, overheating monitoring, and undervoltage lockout.\u003c\/li\u003e\n\u003cli\u003eLow saturation voltage drop (typical 1.8V at 300A).\u003c\/li\u003e\n\u003cli\u003eDesigned for high-reliability industrial environments with support for switching frequencies up to 25 kHz.\u003c\/li\u003e\n\u003cli\u003ePress-fit packaging facilitates robust mounting to heat sinks or PCB assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMotor speed and torque control in production lines, conveyors, and material handling systems.\u003c\/li\u003e\n\u003cli\u003ePumping and ventilation systems for water supply and HVAC.\u003c\/li\u003e\n\u003cli\u003eRenewable energy grid-tie inverters for wind and solar power conversion.\u003c\/li\u003e\n\u003cli\u003eHigh-voltage switching for industrial robotics and manufacturing cells.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS300R12KE3\/AGDR-62C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e1200 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e300 A (RMS at 80 degC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Junction Temp\u003c\/td\u003e\n\u003ctd\u003e150 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +125 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Frequency\u003c\/td\u003e\n\u003ctd\u003eUp to 25 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSaturation Voltage\u003c\/td\u003e\n\u003ctd\u003e1.8 V (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Resistance\u003c\/td\u003e\n\u003ctd\u003e1-10 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e The module contains sensitive electronic components. Always use an anti-static wrist strap and handle by the edges to prevent electrostatic discharge damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBusbar Alignment:\u003c\/strong\u003e Ensure physical layout of AC busbars is perfectly symmetrical to maintain balanced current distribution and prevent localized thermal wear.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDriver Board Consistency:\u003c\/strong\u003e When replacing modules in parallel, ensure all gate driver boards share identical firmware revisions and component batches to prevent switching delays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement Practice:\u003c\/strong\u003e It is highly recommended to replace the ribbon cable during module installation to ensure reliable communication and prevent drive faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Removal:\u003c\/strong\u003e Power down the drive, remove fiber-optic links and auxiliary power cables, unfasten AC output busbars, and extract the assembly by unscrewing the housing mounting points.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the FS300R12KE3\/AGDR-62C?\u003c\/h3\u003e\u003cp\u003eThe ABB FS300R12KE3\/AGDR-62C is an integrated IGBT and drive board module widely used in ABB industrial drives, specifically the ACS800 multidrive systems.\u003c\/p\u003e\u003ch3\u003eShould I replace the ribbon cable when installing a new module?\u003c\/h3\u003e\u003cp\u003eYes, it is highly recommended to use a brand-new ribbon cable when replacing the IGBT module to ensure optimal communication and prevent drive faults.\u003c\/p\u003e\u003ch3\u003eWhat safety precautions are required when handling this board?\u003c\/h3\u003e\u003cp\u003eThe board contains sensitive electronic components prone to electrostatic discharge (ESD). Always use an anti-static wrist strap, handle the module by its edges, and store it in an anti-static bag when not actively in use.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50916005937404,"sku":"FS300R12KE3\/AGDR-62C","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8c51866c-e791-4dad-8299-f18e4ec1fd01.jpg?v=1785844876","url":"https:\/\/www.electronicplc.com\/es\/products\/abb-drives-fs300r12ke3-agdr-62c-insulated-gate-bipolar-transistor","provider":"Electronic PLC","version":"1.0","type":"link"}