{"product_id":"allen-bradley-2711-k5a15-keypad-interface-terminal","title":"Allen-Bradley 2711-K5A15 PanelView Standard Operator Terminal","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Allen-Bradley 2711-K5A15 is a robust industrial Human-Machine Interface (HMI) from the PanelView Standard series, engineered for reliable process monitoring and control in demanding plant-floor environments. This terminal features a 5.5-inch monochrome blue-mode transflective LCD, providing high-contrast visibility for real-time diagnostics, alarm management, and system parameter adjustments. Designed for integration into heavy industrial sectors such as water treatment, chemical processing, and automated logistics, the 2711-K5A15 ensures consistent operational oversight and efficient workflow management.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Technology:\u003c\/strong\u003e 5.5-inch monochrome blue-mode transflective LCD with a 256 x 128 pixel resolution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Life Illumination:\u003c\/strong\u003e Integrated LED backlight rated for 100,000 hours of service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTactile Interface:\u003c\/strong\u003e Rugged mechanical keypad featuring dedicated function keys (F1-F10), a numeric keypad, and navigation arrows for precise operator input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Connectivity:\u003c\/strong\u003e Equipped with a ControlNet communication node for deterministic data exchange with Allen-Bradley PLCs, plus an RS-232 serial port for printer connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Capacity:\u003c\/strong\u003e Includes 170 KB of application runtime memory and 240 KB of nonvolatile memory for storing bitmaps, text, and application objects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Protection:\u003c\/strong\u003e Rated for NEMA 12\/13 and 4X (indoor) and IP54\/IP65, ensuring resistance to dust and moisture ingress.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe 2711-K5A15 is ideal for applications requiring direct, high-visibility interaction with automation control systems. Typical use cases include monitoring pump stations, managing conveyor routing, tracking machine-level diagnostic logs, and providing local operator control for PLC-based manufacturing cells.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K5A15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e5.5 inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC (120 VAC Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% Non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 12\/13, 4X, IP54, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the panel cutout is prepared according to the manufacturer's mounting template to maintain the integrity of the NEMA\/IP seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Wiring:\u003c\/strong\u003e Verify the supply voltage is within the 85-264 VAC range before connection. Ensure proper grounding of the chassis to prevent EMI-related logic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Handle the terminal with standard electrostatic discharge (ESD) precautions to protect internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Install in an area free from excessive vibration and direct exposure to corrosive chemicals. Ensure adequate ventilation to maintain operating temperatures below 55 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e Power down the unit before performing any maintenance or cable connections to the ControlNet or RS-232 ports.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary communication protocol for this terminal?\u003c\/strong\u003e The 2711-K5A15 utilizes a ControlNet communication node for deterministic messaging with supported Allen-Bradley controllers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this unit be used outdoors?\u003c\/strong\u003e No, while the unit carries NEMA 4X ratings, it is designed for indoor use only.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the purpose of the RS-232 port?\u003c\/strong\u003e The RS-232 port on this model is dedicated to printer connectivity for generating hardcopy alarm summaries and diagnostic reports.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":50912382288124,"sku":"2711-K5A15","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_d1b8e97f-b186-4e0e-a578-923c4cd575d6.jpg?v=1785744856","url":"https:\/\/www.electronicplc.com\/es\/products\/allen-bradley-2711-k5a15-keypad-interface-terminal","provider":"Electronic PLC","version":"1.0","type":"link"}