{"product_id":"allen-bradley-flex-i-o-1794-ov32-output-module","title":"Allen-Bradley 1794-OV32 FLEX I\/O 32-Point 24V DC Sinking Output Module","description":"\u003cp\u003eThe Allen-Bradley 1794-OV32 is a high-density discrete output module belonging to the FLEX I\/O product family. It provides 32 sinking output channels designed for 24V DC operation, offering a compact and flexible solution for industrial control applications requiring high-density digital output control.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32-point discrete output configuration with current sinking capability.\u003c\/li\u003e\n\u003cli\u003eDesigned for integration within the Allen-Bradley FLEX I\/O system, supporting modular expansion.\u003c\/li\u003e\n\u003cli\u003eWide operating voltage range (10V to 31.2V DC) to accommodate various field device requirements.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for real-time monitoring of each individual output channel.\u003c\/li\u003e\n\u003cli\u003eGroup-isolated design to enhance system safety and fault isolation.\u003c\/li\u003e\n\u003cli\u003eDIN-rail mountable for efficient panel space utilization.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAutomotive assembly stations, including pneumatic valve control and clamping cylinders.\u003c\/li\u003e\n\u003cli\u003ePackaging and bottling lines for high-speed conveyor and sorting gate management.\u003c\/li\u003e\n\u003cli\u003eMaterial handling systems such as palletizers and automated storage and retrieval systems (AS\/RS).\u003c\/li\u003e\n\u003cli\u003eMachine tool control for coolant pumps, interlocks, and positioning indicators.\u003c\/li\u003e\n\u003cli\u003eIndustrial HVAC control skids for damper and fan actuation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1794-OV32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e32-point DC Sinking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10V - 31.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlexbus Current\u003c\/td\u003e\n\u003ctd\u003e110 mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4.4 W @ 31.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e8.53 BTU\/hr @ 31.2V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e50V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Leakage\u003c\/td\u003e\n\u003ctd\u003e0.5 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e2 A for 50 ms (repeatable every 2 seconds)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyswitch Setting:\u003c\/strong\u003e Ensure the keyswitch on the terminal base is set to position 2 to match the 1794-OV32 module type before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Hook the terminal base onto a 35mm DIN rail. Align the module's alignment bar with the groove on the terminal base and press down firmly until the latching mechanism locks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexbus Connection:\u003c\/strong\u003e Ensure the Flexbus connector is fully engaged to the left to establish communication with the adjacent adapter or terminal base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Always handle modules with care, ensuring pins on the bottom are straight and free from debris.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e While FLEX I\/O supports removal and insertion under power (RIUP), ensure the system environment is safe before performing maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 1794-OV32?\u003c\/h3\u003e\u003cp\u003eThe 1794-OV32 is a 32-point digital output module used to interface a controller with field devices such as solenoids, relays, or indicators in a 24V DC sinking configuration.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with standard FLEX I\/O terminal bases?\u003c\/h3\u003e\u003cp\u003eYes, it is designed to mount onto standard FLEX I\/O terminal bases, which provide the wiring termination points for the field devices.\u003c\/p\u003e\u003ch3\u003eWhat does the sinking output configuration mean?\u003c\/h3\u003e\u003cp\u003eA sinking output switches the negative side (common) of the load to ground, meaning the load is connected between the positive supply and the module output.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51179820384508,"sku":"1794-OV32","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_36f5f569-c0ed-40fb-b325-2e5d2c556ebd.jpg?v=1788110325","url":"https:\/\/www.electronicplc.com\/es\/products\/allen-bradley-flex-i-o-1794-ov32-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}