{"product_id":"analog-input-module-yokogawa-aav141-s03-k4a00","title":"Analog Input Module YOKOGAWA AAV141-S03\/K4A00","description":"\u003cp\u003eConfigured for high-density signal acquisition in CENTUM VP distributed control systems, the \u003cstrong\u003eYOKOGAWA AAV141-S03\/K4A00\u003c\/strong\u003e (\u003cstrong\u003eAAV141-S03\/K4A00\u003c\/strong\u003e Analog Input Module) provides direct electrical execution of 16-channel analog inputs. The module facilitates the conversion of standardized 4-20 mA or 1-5 VDC field signals into digitized process data for integration within FIO (Fieldbus I\/O) architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAV141-S03\/K4A00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubject to backplane load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC \/ 1-5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eNon-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AAV141-S03\/K4A00 architecture supports high-speed signal sampling across its 16 input channels. While the module maintains a non-isolated design, it is engineered for direct compatibility with standard 4-20 mA HART loop protocol loops when utilizing appropriate termination components. In dual-redundant configurations, the module synchronizes data reporting with a secondary counterpart to ensure continuous signal availability to the Field Control Unit (FCU). The internal hardware logic is calibrated for stability across the specified temperature range, minimizing signal drift in process automation environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AAV141-S03\/K4A00 be configured for mixed signal types within the same module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 16 channels support individual configuration for either 4-20 mA or 1-5 VDC input ranges, provided the physical jumpers or software-defined parameters are set correctly for each specific loop.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of redundant operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, this module supports dual-redundant configuration when installed in a compatible FIO node, allowing for seamless failover in the event of primary module hardware failure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet is de-energized prior to mounting or removing the module from the DIN rail or panel.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is correctly aligned with the FIO backplane connector to prevent pin damage during insertion.\u003c\/li\u003e\n\u003cli\u003eTighten all terminal screws to the manufacturer-specified torque to maintain secure electrical connections and prevent high-resistance contact points.\u003c\/li\u003e\n\u003cli\u003eWhen wiring field inputs, ensure that cable shields are properly bonded to the cabinet's instrument ground bus at the entry point to reduce common-mode electromagnetic noise.\u003c\/li\u003e\n\u003cli\u003eIn non-isolated configurations, confirm that field transmitters do not share a common ground reference that could induce ground loop currents across multiple channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":50111841927420,"sku":"AAV141-S03\/K4A00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AAV141-S03K4A00.jpg?v=1784165734","url":"https:\/\/www.electronicplc.com\/es\/products\/analog-input-module-yokogawa-aav141-s03-k4a00","provider":"Electronic PLC","version":"1.0","type":"link"}