{"product_id":"bently-nevada-133819-02-3500-61-rtd-tc-non-isolated-i-o-module","title":"Bently Nevada 133819-02 3500\/61 RTD\/TC Non-Isolated I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 133819-02 is a 6-channel RTD\/TC Non-Isolated I\/O module designed for use with the 3500\/61 Temperature Monitor within the 3500 Machinery Protection System. This module features internal terminations and provides critical temperature monitoring capabilities by conditioning inputs from Resistance Temperature Detectors (RTDs) and Thermocouples (TCs). It compares these inputs against user-programmable alarm setpoints to ensure the integrity and safety of rotating machinery. Unlike the 3500\/60 variant, the 3500\/61 series (including this 133819-02 module) provides recorder outputs for each of its six channels.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e6-channel high-density temperature monitoring\u003c\/li\u003e\n\u003cli\u003eIntegrated recorder outputs for each channel\u003c\/li\u003e\n\u003cli\u003eSupports both RTD (2, 3, 4-wire) and Thermocouple (J, K, T, E) inputs\u003c\/li\u003e\n\u003cli\u003eConfigurable alarm setpoints via 3500 Rack Configuration Software\u003c\/li\u003e\n\u003cli\u003eHot-swappable functionality for maintenance without system shutdown\u003c\/li\u003e\n\u003cli\u003eReal-time hardware self-testing for diagnostic reliability\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTurbines: Monitoring bearing and casing temperatures for gas, steam, and hydro turbines.\u003c\/li\u003e\n\u003cli\u003eCompressors: Tracking critical temperatures in centrifugal, axial, and reciprocating compressors.\u003c\/li\u003e\n\u003cli\u003eGenerators: Stator and bearing heat monitoring for large-scale power generation.\u003c\/li\u003e\n\u003cli\u003eMotors and Pumps: Overheating protection for continuous-operation industrial motors and pumps.\u003c\/li\u003e\n\u003cli\u003eGearboxes: Oil and bearing temperature monitoring to detect early signs of wear or friction.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e133819-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated RTD\/TC I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eRTD (PT100, PT1000), Thermocouple (J, K, T, E)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRTD Excitation\u003c\/td\u003e\n\u003ctd\u003e1 mA per channel (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 degC to ±0.5 degC (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e≥1 MΩ (TC), ~100 Ω (RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the 3500 rack power is disconnected before installing or removing the I\/O module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using proper ESD (Electrostatic Discharge) precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eVerify that the I\/O module matches the configuration of the 3500\/61 monitor module installed in the rack.\u003c\/li\u003e\n\u003cli\u003eEnsure all internal wiring is securely terminated according to the site-specific loop diagrams.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the 3500 rack to prevent overheating of the I\/O components.\u003c\/li\u003e\n\u003cli\u003eRoute sensor signal cables away from high-voltage or high-EMI sources to minimize signal noise.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the Bently Nevada 133819-02?\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 133819-02 is a 6-channel RTD\/TC Non-Isolated I\/O Module with internal terminations, designed for the 3500\/61 temperature monitoring system to measure resistance temperature detectors and thermocouples.\u003c\/p\u003e\u003ch3\u003eWhat is the function of the 133819-02 module?\u003c\/h3\u003e\u003cp\u003eIt is used for temperature monitoring in 3500 series racks. It conditions sensor inputs and compares them to user-defined alarm setpoints to trigger alerts or shutdowns.\u003c\/p\u003e\u003ch3\u003eDoes this module include recorder outputs?\u003c\/h3\u003e\u003cp\u003eYes, the 133819-02 (3500\/61) includes recorder outputs for each of its six channels, which allows for external signal processing or data logging.\u003c\/p\u003e\u003ch3\u003eWhat is the difference between 133819-02 and 133819-01?\u003c\/h3\u003e\u003cp\u003eBoth are 6-channel I\/O modules, but they are not interchangeable. The 133819-02 is specific to the 3500\/61 monitor which supports recorder output functionality.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50923431952636,"sku":"133819-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8b81588d-4f76-49e7-9db4-9091b743894a.jpg?v=1785987377","url":"https:\/\/www.electronicplc.com\/es\/products\/bently-nevada-133819-02-3500-61-rtd-tc-non-isolated-i-o-module","provider":"Electronic PLC","version":"1.0","type":"link"}