{"product_id":"digital-controller-power-supply-module-woodward-5466-1001","title":"Digital Controller Power Supply Module Woodward 5466-1001","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 5466-1001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e5466-1001\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for stable power distribution and voltage conversion within MicroNet digital controller platforms. The module converts 110 VAC or 125 VDC main input lines into a regulated 24 VDC output at up to 16 A, supplying continuous operating power across the backplane chassis while maintaining network galvanic isolation up to 1000 Vrms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5466-1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e461 mm (H) x 265 mm (W) x 59 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConverts to 24 VDC @ 16 A output (384 W max load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e110 VAC \/ 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Stub Length\u003c\/td\u003e\n\u003ctd\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Isolation\u003c\/td\u003e\n\u003ctd\u003e1000 Vrms (0-60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Sensing Range\u003c\/td\u003e\n\u003ctd\u003e1 to 30 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eThermal Heat Sink Dissipation Profiles\u003c\/h3\u003e\n\u003cp\u003eThe power supply chassis is engineered with optimized thermal heat sink dissipation profiles to withstand continuous operation in extreme environmental conditions. Utilizing heavy-duty aluminum conduction channels, the board dissipates heat generated by internal power electronics during 16 A load drops across an extended temperature window of -40 deg C to +105 deg C. This thermal management prevents voltage drift and thermal shutdown during peak demand cycles without requiring internal cooling fans.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input power sources can be wired to the primary input terminals?\u003c\/p\u003e\n\u003cp\u003eA: The module accommodates both AC and DC industrial power feeds, operating on either 110 VAC or 125 VDC utility inputs without requiring physical jumper selection.\u003c\/p\u003e\n\u003cp\u003eQ: How does the integrated network isolation protect backplane electronics?\u003c\/p\u003e\n\u003cp\u003eA: The onboard isolation circuitry provides 1000 Vrms isolation across 0-60 Hz line frequencies, preventing high-voltage line surges and ground loops from transferring to sensitive controller backplane logic.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum permitted length for the secondary power stub connections?\u003c\/p\u003e\n\u003cp\u003eA: Secondary power stub wiring must not exceed a maximum length of 300 mm to ensure low trace resistance and prevent voltage drops under high current loads.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module firmly into the designated chassis power slot, securing top and bottom mounting panel screws to establish earth ground contact with the rack enclosure.\u003c\/li\u003e\n\u003cli\u003eVerify that primary power feed lines (110 VAC or 125 VDC) are de-energized prior to landing wiring onto input terminal blocks.\u003c\/li\u003e\n\u003cli\u003eWire the main input lines using 14 AWG stranded copper conductors rated for high-temperature service, ensuring tight terminal screw torque.\u003c\/li\u003e\n\u003cli\u003eKeep secondary 24 VDC power distribution stub wiring below the 300 mm maximum length specification to minimize inductive line noise and voltage drops.\u003c\/li\u003e\n\u003cli\u003eApply input power and verify that the output voltage stabilizes at 24 VDC before bringing connected controller I\/O modules online.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50734295056636,"sku":"5466-1001","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5466-10012.jpg?v=1785289632","url":"https:\/\/www.electronicplc.com\/es\/products\/digital-controller-power-supply-module-woodward-5466-1001","provider":"Electronic PLC","version":"1.0","type":"link"}