{"product_id":"easygen-3000-series-woodward-genset-controller","title":"Woodward easYgen-3000 Series Genset Controller","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Woodward easYgen-3000 Series is a robust, versatile control unit engineered for the management of gas and steam turbines, as well as compressors. It is designed to handle both simple and complex paralleling applications for up to 32 gensets, utilizing advanced automatic sequencing to ensure reliable power generation. Widely deployed in critical infrastructure such as power plants, refineries, and mining operations, this controller optimizes load sharing and synchronization to maintain grid stability and minimize operational downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports paralleling of up to 32 gensets with decentralized peer-to-peer control logic.\u003c\/li\u003e\n\u003cli\u003eIntegrated engine and generator protection, including comprehensive monitoring of voltage, frequency, and current.\u003c\/li\u003e\n\u003cli\u003eMultiple operating modes including AMF (Automatic Mains Failure), peak shaving, and import\/export control.\u003c\/li\u003e\n\u003cli\u003eFlexible I\/O configuration with digital and analog arrays for precise speed and voltage regulation.\u003c\/li\u003e\n\u003cli\u003eCommunication interfaces include CANbus for inter-module data exchange, plus RS-485 and Ethernet for system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe easYgen-3000 is suitable for industrial power networks requiring high availability and precise control. Common applications include standby power systems, base-load power plants, cogeneration facilities, and complex industrial microgrids where synchronization and load management are critical.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eeasYgen-3000 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Type\u003c\/td\u003e\n\u003ctd\u003eTurbomachinery Control and Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 32 gensets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 or 24 VDC (8 to 40 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox 15 to 20 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eCANbus, RS-485, Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the controller is mounted in a clean, dry environment protected from excessive vibration and extreme heat.\u003c\/li\u003e\n\u003cli\u003eVerify that the power supply voltage is within the specified 8 to 40 VDC range before connection.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for CANbus and RS-485 communication to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the controller chassis to the common system ground to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003ePower down the system before inserting or removing any wiring connectors to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eFollow standard industrial practices for routing signal cables away from high-voltage power lines.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the easYgen-3000 compatible with different engine types?\u003c\/h3\u003e\u003cp\u003eYes, the easYgen-3000 is designed for versatility and can be configured for a wide range of gas and steam turbine applications, as well as compressors, provided the system parameters are correctly mapped within the controller software.\u003c\/p\u003e\u003ch3\u003eCan this unit be used for standalone applications?\u003c\/h3\u003e\u003cp\u003eWhile the easYgen-3000 excels in paralleling and multi-unit sequencing, it is fully capable of managing standalone genset operations with comprehensive protection and monitoring features.\u003c\/p\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50632334246140,"sku":"ESAYGEN-3000","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b74c9ee8-b761-4f5c-80fe-eb766d7425b7.jpg?v=1784879516","url":"https:\/\/www.electronicplc.com\/es\/products\/easygen-3000-series-woodward-genset-controller","provider":"Electronic PLC","version":"1.0","type":"link"}