{"product_id":"electronic-governor-woodward-8200-1300","title":"Electronic Governor WOODWARD 8200-1300","description":"\u003cp\u003eThe \u003cstrong\u003eWOODWARD 8200-1300\u003c\/strong\u003e serves as the primary \u003cstrong\u003e8200-1300\u003c\/strong\u003e Electronic Governor utilized to execute speed and load regulation across gas and steam turbine platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8200-1300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWOODWARD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg (5.51 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 x 120 x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 70 deg C (-4 to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e115\/230 VAC +\/-10% (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElectronic Governor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response and Thermal Dissipation Profiles\u003c\/h3\u003e\n\u003cp\u003eThe controller processes turbine speed sensor inputs to execute closed-loop valve position commands. Internal processing loops continuously calculate speed deviations and adjust output signals to optimize actuator loop feedback response during transient load changes. The physical housing relies on passive air conduction across thermal heat sink dissipation profiles to prevent thermal drift within the ambient operating range of -20 to 70 deg C.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is dual-voltage input selection configured on the power terminal block?\u003c\/p\u003e\n\u003cp\u003eA: The input power supply accepts 115 VAC or 230 VAC nominal inputs within a +\/-10% tolerance band. Terminal jumpers or internal selector wiring must be set according to the site AC supply voltage before applying line power.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanism prevents noise interference on the speed sensing inputs?\u003c\/p\u003e\n\u003cp\u003eA: Magnetic pickup sensor lines must use twisted-pair shielded cabling grounded at the governor chassis only, isolating the high-frequency pulse counting circuits from external common-mode noise.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the unit securely onto a standard 35 mm DIN rail inside an enclosure, ensuring mechanical latching is fully engaged.\u003c\/li\u003e\n\u003cli\u003eVerify that the AC supply voltage matches the configured 115 VAC or 230 VAC terminal setting before energizing the module.\u003c\/li\u003e\n\u003cli\u003eWire speed sensor inputs using low-capacitance shielded twisted-pair conductors, terminating the cable shield at the designated ground terminal.\u003c\/li\u003e\n\u003cli\u003eRoute low-voltage control lines and communications interface cables in separate wire ducts away from high-current AC power leads.\u003c\/li\u003e\n\u003cli\u003eProvide a minimum vertical clearance of 50 mm above and below the housing to maintain unimpeded natural convection airflow across the enclosure heatsink.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50734055522556,"sku":"8200-1300","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/8200-13001.jpg?v=1785289629","url":"https:\/\/www.electronicplc.com\/es\/products\/electronic-governor-woodward-8200-1300","provider":"Electronic PLC","version":"1.0","type":"link"}