{"product_id":"emerson-deltav-kj3001x1-ba1-12p0549x112-discrete-input-module","title":"Emerson DeltaV KJ3001X1-BA1 12P0549X112 8-Channel Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ3001X1-BA1 (12P0549X112) is an 8-channel isolated discrete input module designed for the DeltaV M-Series automation system. This module provides reliable interface capabilities for 24 VDC field switches and sensors. By utilizing galvanic isolation, it ensures signal integrity and protects the system controller from electrical surges originating from the field side. It is engineered for demanding industrial environments, including oil refineries, chemical processing, and mining operations.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel isolated discrete input architecture.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for enhanced signal protection.\u003c\/li\u003e\n\u003cli\u003eSupports hot-swapping for reduced maintenance downtime.\u003c\/li\u003e\n\u003cli\u003eMechanical rotary keying (Position B2) to prevent incorrect module insertion.\u003c\/li\u003e\n\u003cli\u003eCertified for use in hazardous atmosphere locations.\u003c\/li\u003e\n\u003cli\u003eNo calibration required; maintenance-free design.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3001X1-BA1 (12P0549X112)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 5 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (Non-Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Rating\u003c\/td\u003e\n\u003ctd\u003eII 3 G \/ EEx nA IIC T4 (Nemko 02ATEX431U)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10g 1\/2 Sinewave for 11 msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm P-P (5-16 Hz); 0.5g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContaminant Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the I\/O carrier.\u003c\/li\u003e\n\u003cli\u003eVerify the mechanical rotary keying on the terminal block is set to Position B2 to match the module.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in the carrier to maintain proper electrical contact and environmental protection.\u003c\/li\u003e\n\u003cli\u003eRoute field wiring away from high-voltage or high-EMI sources to maintain signal accuracy.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation is provided to maintain ambient temperatures within the specified 0 to 60 deg C range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module hot-swappable?\u003c\/h3\u003e\u003cp\u003eYes, the KJ3001X1-BA1 supports hot-swapping within the DeltaV M-Series carrier, allowing for replacement without shutting down the entire system, provided standard safety procedures are followed.\u003c\/p\u003e\u003ch3\u003eWhat is the purpose of the keying system?\u003c\/h3\u003e\u003cp\u003eThe mechanical rotary keying at Position B2 is a safety feature designed to prevent the accidental insertion of an incompatible I\/O card into a slot configured for a specific type of signal.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50517437251836,"sku":"KJ3001X1-BA1 12P0549X112","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c20010aa-1f10-4487-80a9-5e909f1ed33b.jpg?v=1784769120","url":"https:\/\/www.electronicplc.com\/es\/products\/emerson-deltav-kj3001x1-ba1-12p0549x112-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}