{"product_id":"emerson-deltav-kj3001x1-bc1-discrete-input-module","title":"Emerson DeltaV KJ3001X1-BC1 8-Channel Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ3001X1-BC1 is an 8-channel isolated discrete input module designed for the DeltaV Scalable Process System. This module provides reliable sensing for 24 VDC field signals in demanding industrial environments, including oil and gas, chemical processing, and power generation. Its isolated architecture is engineered to provide superior noise immunity and signal integrity, protecting sensitive control logic from field-side electrical disturbances.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 isolated discrete input channels for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eDesigned for direct interface with 24 VDC field devices.\u003c\/li\u003e\n\u003cli\u003eIntegrated hardware keying (B2 position) to prevent incorrect module-to-terminal block insertion.\u003c\/li\u003e\n\u003cli\u003eSupports hot-swapping in non-hazardous locations or under specific conditions in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eRobust design compliant with ISA-S71.04-1985 Class G3 for protection against airborne contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically deployed in DeltaV I\/O subsystems for monitoring status signals from field devices such as limit switches, proximity sensors, and auxiliary contacts. It is suitable for use in both standard industrial environments and hazardous area applications where Zone 2 compliance is required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3001X1-BC1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input (DI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC @ 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC @ 5 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (Non-Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10g (1\/2 Sinewave, 11 msec)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1mm P-P (5-16Hz); 0.5g (16-150Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Rating\u003c\/td\u003e\n\u003ctd\u003eII 3 G, EEx nA IIC T4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Keying\u003c\/td\u003e\n\u003ctd\u003eB2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is de-energized before installation or removal, unless specifically authorized for hot-swapping in your system configuration.\u003c\/li\u003e\n\u003cli\u003eVerify the terminal block keying (B2) matches the module before attempting to seat the card.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices to ensure the effectiveness of the isolated input circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation in the cabinet to maintain operating temperatures between 0 and 60 deg C.\u003c\/li\u003e\n\u003cli\u003eFor hazardous area installations, ensure all field wiring complies with local electrical codes and the specific certification requirements (e.g., ATEX).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module hot-swappable?\u003c\/h3\u003e\u003cp\u003eYes, the module supports hot-swapping when used with a compatible system power supply and provided that inductance limits are maintained. However, always ensure that field power is de-energized before maintenance in hazardous atmospheres to prevent ignition risks.\u003c\/p\u003e\u003ch3\u003eDoes this module require field calibration?\u003c\/h3\u003e\u003cp\u003eNo, the KJ3001X1-BC1 is a solid-state digital input module and does not require periodic field calibration. There are no user-serviceable parts inside the unit.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50517710504188,"sku":"KJ3001X1-BC1","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_996cfee9-fcbd-4dc5-a47b-1479af6d4221.jpg?v=1784774499","url":"https:\/\/www.electronicplc.com\/es\/products\/emerson-deltav-kj3001x1-bc1-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}