{"product_id":"emerson-deltav-kj3102x1-ba1-12p1863x032-analog-input-module","title":"Emerson DeltaV KJ3102X1-BA1 12P1863X032 8-Channel Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson KJ3102X1-BA1 (12P1863X032) is a high-density 8-channel analog input module designed for the DeltaV S-series distributed control system. This module is specifically engineered to process 4-20 mA signals with superimposed HART digital communication, enabling advanced asset management and remote configuration of field devices. It is widely utilized in critical process industries, including oil and gas, chemical refining, and power generation, where precise monitoring of pressure, temperature, and flow is essential for operational safety and efficiency.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel high-density analog input.\u003c\/li\u003e\n\u003cli\u003eIntegrated HART modem for digital communication with smart field instruments.\u003c\/li\u003e\n\u003cli\u003e16-bit resolution for high-precision process monitoring.\u003c\/li\u003e\n\u003cli\u003eHot-swappable design allows for replacement without power-down or system disruption.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation between field-side and system-side to protect internal logic from electrical surges.\u003c\/li\u003e\n\u003cli\u003eSupports predictive maintenance through real-time diagnostic data and secondary process variables.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is designed for integration into DeltaV S-series I\/O subsystems. It is ideal for applications requiring the monitoring of smart transmitters, pressure sensors, flow meters, and temperature transducers that utilize the HART protocol for enhanced diagnostic feedback.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3102X1-BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P1863X032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV S-series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous (field-to-system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the DeltaV S-series carrier is properly grounded before module installation.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for hot-swapping; however, ensure the area is free of hazardous gases if operating in a classified zone.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analog input signals to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the field device HART communication is enabled and configured correctly within the DeltaV software environment.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the I\/O rack to ensure the module operates within the specified temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes this module support non-HART devices?\u003c\/h3\u003e\u003cp\u003eYes, the KJ3102X1-BA1 is backward compatible and can function as a standard 4-20 mA analog input module for devices that do not support HART communication.\u003c\/p\u003e\u003ch3\u003eCan this module be replaced while the system is running?\u003c\/h3\u003e\u003cp\u003eYes, the DeltaV S-series architecture supports hot-swapping, allowing you to remove and replace the module without interrupting the power to the carrier or affecting other active modules.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50558853972220,"sku":"KJ3102X1-BA1 12P1863X032","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_f55b690d-fdc1-4962-8511-1e8ff905d81f.jpg?v=1784799470","url":"https:\/\/www.electronicplc.com\/es\/products\/emerson-deltav-kj3102x1-ba1-12p1863x032-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}