{"product_id":"emerson-deltav-s-series-kj3204x1-bk1-se4002s1t2b6-discrete-output-module","title":"Emerson DeltaV KJ3204X1-BK1 SE4002S1T2B6 32-Channel Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ3204X1-BK1 (also identified by model SE4002S1T2B6) is a high-density S-Series Discrete Output module designed for the DeltaV digital automation system. This 32-channel high-side switching module is engineered to drive field loads such as interposing relays, solenoid valves, and status indicators. By consolidating 32 points of control into a single card, it optimizes cabinet space and reduces the overall footprint of the control system. The module is built for demanding industrial environments, including petrochemical, power generation, and water treatment facilities, offering robust protection against corrosive contaminants and extreme temperatures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32-channel high-side discrete output configuration.\u003c\/li\u003e\n\u003cli\u003eOptimized for 24 VDC field load applications.\u003c\/li\u003e\n\u003cli\u003eHigh-density design to maximize cabinet space.\u003c\/li\u003e\n\u003cli\u003eRotary keying system (Position B4) for secure terminal block alignment.\u003c\/li\u003e\n\u003cli\u003eG3-level corrosion resistance for harsh environments.\u003c\/li\u003e\n\u003cli\u003eHazardous area rated for Class I Division 2 and Zone 2 applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in DeltaV S-Series control systems for managing discrete field devices. Typical applications include the operation of solenoid valves, status lamps, and interposing relays in automated process control loops within refineries, chemical plants, and power utility infrastructures.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3204X1-BK1 (SE4002S1T2B6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e32-Channel Discrete Output (High-Side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Bus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBussed Field Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 3.2 A per card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 100 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex ec IIC Gc \/ Cl. I Div. 2 GP. A,B,C,D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContaminant Rating\u003c\/td\u003e\n\u003ctd\u003eISA-S71.04-1985 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Keying\u003c\/td\u003e\n\u003ctd\u003ePosition B4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always de-energize both system power and field power before installing or removing the module from the carrier.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeying:\u003c\/strong\u003e Ensure the rotary keying on the carrier matches the B4 position of the module to prevent improper insertion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the installation location meets the specified temperature and humidity requirements. The module is designed for use in G3-rated environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Observe standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is fully seated into the S-Series carrier and that the locking mechanism is engaged.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\u003cp\u003eThe KJ3204X1-BK1 complies with international standards for hazardous locations, including FM19ATEX0173U, IECEx FMG 19.0019U, and FM21UKEX0017U.\u003c\/p\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module compatible with all DeltaV systems?\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for the DeltaV S-Series hardware ecosystem. It requires a compatible S-Series carrier and terminal block with B4 keying.\u003c\/p\u003e\u003ch3\u003eCan this module be used in hazardous areas?\u003c\/h3\u003e\u003cp\u003eYes, it is certified for use in Class I Division 2 and Zone 2 (Ex ec IIC Gc) hazardous locations, provided it is installed in accordance with local safety regulations and the DeltaV installation manual.\u003c\/p\u003e\u003ch3\u003eWhat is the maximum current capacity?\u003c\/h3\u003e\u003cp\u003eThe module supports a field circuit rating of 100 mA per channel, with a total card capacity of 3.2 A.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50646305145084,"sku":"KJ3204X1-BK1 SE4002S1T2B6","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_d3dc18cb-85f3-430a-8c97-f6e4cce1608f.jpg?v=1785025303","url":"https:\/\/www.electronicplc.com\/es\/products\/emerson-deltav-s-series-kj3204x1-bk1-se4002s1t2b6-discrete-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}