{"product_id":"emerson-ve4005s2b2-kj3221x1-ba1-12p2531x092-analog-output-module","title":"Emerson VE4005S2B2 KJ3221X1-BA1 12P2531X092 8-Channel Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson KJ3221X1-BA1 (also identified as VE4005S2B2 or 12P2531X092) is a high-performance 8-channel Analog Output module engineered for the DeltaV M-Series automation system. This module provides precise 4-20 mA current signals to control field actuators, valves, and positioners. It features integrated HART digital communication, enabling advanced device diagnostics, configuration, and proactive asset management. Designed for mission-critical reliability, it is suitable for demanding industrial environments including oil and gas refining, chemical processing, and power generation.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-channel analog output with 4-20 mA signal range.\u003c\/li\u003e\n\u003cli\u003eIntegrated HART pass-through for remote device health monitoring and configuration.\u003c\/li\u003e\n\u003cli\u003eMechanical rotary keying (Position A4) to ensure correct terminal block compatibility.\u003c\/li\u003e\n\u003cli\u003eRobust environmental protection, rated for ISA-S71.04-1985 Class G3 contaminants.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range from -40 to +70 deg C.\u003c\/li\u003e\n\u003cli\u003eSupports energy-limited \"nL\" installations for hazardous area applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for use within the Emerson DeltaV M-Series distributed control system (DCS). It is commonly utilized for controlling final control elements such as pneumatic control valves, I\/P transducers, and other 4-20 mA field instruments that require HART-based diagnostic capabilities.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3221X1-BA1 (VE4005S2B2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e8-Channel Analog Output Card (HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Bus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBussed Field Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 23 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (Non-Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Ratings\u003c\/td\u003e\n\u003ctd\u003eII 3G Ex nA IIC Gc \/ II 3G EEx nL IIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eFM12ATEX0090U, IECEx FMG 12.0035U, Nemko 02ATEX431U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\/Shock\u003c\/td\u003e\n\u003ctd\u003e10g Shock; 1mm Peak-to-Peak (2-13.2 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the area is confirmed non-hazardous and field circuits are de-energized before module insertion or removal to prevent sparking.\u003c\/li\u003e\n\u003cli\u003eVerify mechanical keying at Position A4 aligns with the corresponding terminal block before seating the module.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the control cabinet to accommodate the operating temperature range.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for analog signals to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is securely seated in the DeltaV I\/O carrier to maintain electrical connection and grounding.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes this module support HART communication?\u003c\/h3\u003e\u003cp\u003eYes, the KJ3221X1-BA1 supports full HART digital communication, allowing for pass-through of diagnostic data from field devices to the DeltaV control system.\u003c\/p\u003e\u003ch3\u003eCan I replace this module while the system is powered?\u003c\/h3\u003e\u003cp\u003eRemoval and insertion under power (RIUP) is strictly regulated. You must ensure the area is non-hazardous and that all field circuits are de-energized before attempting to remove or install the module.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50517545746684,"sku":"VE4005S2B2 KJ3221X1-BA1 12P2531X092","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c91a14b9-8ad7-478c-af53-e27b0995719e.jpg?v=1784771162","url":"https:\/\/www.electronicplc.com\/es\/products\/emerson-ve4005s2b2-kj3221x1-ba1-12p2531x092-analog-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}