{"product_id":"foxboro-i-a-series-p0914xb-baseplate-chassis","title":"Foxboro P0914XB I\/A Series 8-Slot Baseplate Chassis","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Foxboro P0914XB is a foundational hardware component within the I\/A Series distributed control system (DCS). This 8-slot baseplate chassis provides the necessary physical mounting and electrical backplane connectivity for high-performance Fieldbus Modules (FBMs). Engineered for mission-critical industrial applications, including oil refining, power generation, and chemical processing, the P0914XB ensures robust signal integrity and reliable power distribution. It supports hot-swappable module replacement and redundant communication paths, helping to minimize unscheduled downtime and maintain continuous process visibility in demanding environments.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8-slot configuration for high-density I\/O deployment.\u003c\/li\u003e\n\u003cli\u003eSupports redundant 2 Mbps HDLC Fieldbus communication.\u003c\/li\u003e\n\u003cli\u003eIntegrated power busing with transient protection for reliable DC distribution.\u003c\/li\u003e\n\u003cli\u003eDesigned for high-speed data exchange between FBMs and control workstations.\u003c\/li\u003e\n\u003cli\u003eSupports hot-swappable module installation and removal.\u003c\/li\u003e\n\u003cli\u003eRobust construction suitable for harsh industrial cabinet environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe P0914XB baseplate is utilized in Foxboro I\/A Series control systems for large-scale process automation, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOil and gas refinery process control.\u003c\/li\u003e\n\u003cli\u003ePower generation plant monitoring and management.\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical processing facilities.\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment automation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Invensys \/ Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0914XB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eI\/A Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e8-Slot Baseplate Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Count\u003c\/td\u003e\n\u003ctd\u003e8 FBM Positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRedundant Fieldbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Plate Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the mounting surface is clean, level, and capable of supporting the weight of the chassis and installed modules.\u003c\/li\u003e\n\u003cli\u003eThe chassis may be mounted vertically or horizontally within a standard industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate clearance around the unit for proper ventilation and heat dissipation.\u003c\/li\u003e\n\u003cli\u003eVerify that all power is disconnected before installing or removing the baseplate or any FBM modules.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for Fieldbus communication to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the chassis to the cabinet ground bus to maintain signal integrity and safety.\u003c\/li\u003e\n\u003cli\u003eHandle modules with care to prevent electrostatic discharge (ESD) damage to sensitive electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\u003cp\u003eThe P0914XB is designed to meet standard industrial requirements, including CE, UL, CSA, and ATEX Zone 2 certifications.\u003c\/p\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the P0914XB compatible with all Foxboro FBMs?\u003c\/h3\u003e\u003cp\u003eThe P0914XB is designed for use with standard Foxboro I\/A Series Fieldbus Modules. Please verify the specific compatibility of your FBM model with the I\/A Series documentation.\u003c\/p\u003e\u003ch3\u003eDoes this chassis support redundant power supplies?\u003c\/h3\u003e\u003cp\u003eYes, the baseplate is designed to support the redundant power distribution requirements of the I\/A Series architecture.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":50733890306300,"sku":"P0914XB","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_057aec59-9408-4522-880c-2decd9e5b0f3.jpg?v=1785286158","url":"https:\/\/www.electronicplc.com\/es\/products\/foxboro-i-a-series-p0914xb-baseplate-chassis","provider":"Electronic PLC","version":"1.0","type":"link"}