{"product_id":"ge-ds200lrpag1agf-mark-v-ex2000-line-protection-card","title":"GE DS200LRPAG1AGF Mark V EX2000 Line Protection Card","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe DS200LRPAG1AGF is a specialized Line Protection Printed Circuit Card engineered for the General Electric Mark V Speedtronic turbine control system and EX2000 excitation interfaces. This LRPA-acronym board provides essential monitoring and circuit protection for gas and steam turbine management infrastructures. Designed to support both Triple Modular Redundant (TMR) and Simplex configurations, it plays a critical role in safeguarding electrical lines within power generation plants and heavy industrial facilities. By maintaining the integrity of the EX2000 interface, this module minimizes system faults and prevents extensive downtime in high-stakes utility operations.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for integration with GE Mark V and EX2000 excitation systems.\u003c\/li\u003e\n\u003cli\u003eSupports both Simplex and TMR (Triple Modular Redundant) system configurations.\u003c\/li\u003e\n\u003cli\u003eEquipped with one onboard reset switch for manual hardware initialization and diagnostic support.\u003c\/li\u003e\n\u003cli\u003eFeatures standard industrial PCB coating for enhanced environmental protection.\u003c\/li\u003e\n\u003cli\u003eOptimized for high-speed signal processing and reliable line protection logic.\u003c\/li\u003e\n\u003cli\u003eHardware revision level 3, providing refined signal isolation and improved response times.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is primarily utilized in power generation environments, specifically within gas and steam turbine control systems. It is a critical component for line protection in EX2000 excitation interfaces, ensuring the stability and safety of electrical distribution and management systems in heavy industrial plants.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDS200LRPAG1AGF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMark V \/ EX2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctional Acronym\u003c\/td\u003e\n\u003ctd\u003eLRPA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eLine Protection Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReset Configuration\u003c\/td\u003e\n\u003ctd\u003e1 Onboard Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eNormal Industrial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Range\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before installing or removing the circuit card to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eHandle the card using proper ESD (Electrostatic Discharge) mitigation techniques, such as wearing a grounded wrist strap.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in the designated Mark V rack slot to maintain proper backplane communication.\u003c\/li\u003e\n\u003cli\u003eVerify that the environment meets the specified temperature and humidity ranges to ensure long-term reliability.\u003c\/li\u003e\n\u003cli\u003eInspect the board for any physical damage or debris before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes this card require firmware updates?\u003c\/h3\u003e\u003cp\u003eNo, the DS200LRPAG1AGF is designed with fixed, stable logic and does not require field firmware updates for operation.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with TMR systems?\u003c\/h3\u003e\u003cp\u003eYes, this card is engineered to support both Simplex and Triple Modular Redundant (TMR) configurations within the Mark V and EX2000 architecture.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50767187443964,"sku":"DS200LRPAG1AGF","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3cb71b15-cbb6-45b0-85ce-a60151be5107.jpg?v=1785487012","url":"https:\/\/www.electronicplc.com\/es\/products\/ge-ds200lrpag1agf-mark-v-ex2000-line-protection-card","provider":"Electronic PLC","version":"1.0","type":"link"}