{"product_id":"ge-fanuc-ic693mar590-series-90-30-mixed-i-o-module","title":"GE Fanuc IC693MAR590 Series 90-30 Mixed I\/O Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC693MAR590 is a combination input\/output module designed for the GE Fanuc Series 90-30 PLC platform. This module integrates 8 AC input channels and 8 relay output channels into a single compact assembly. It is engineered for demanding automated environments, including power generation, mining, and oil and gas processing, where it facilitates the control of field devices such as motor contactors, valves, and control switches. The module provides 1500 V RMS electrical isolation between field circuits and internal logic to minimize noise interference and enhance system reliability.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 AC input channels with optical isolation.\u003c\/li\u003e\n\u003cli\u003e8 mechanical relay output channels for versatile load switching.\u003c\/li\u003e\n\u003cli\u003e1500 V RMS isolation between field and logic circuits.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of AC input voltages (0 to 132 VAC).\u003c\/li\u003e\n\u003cli\u003eCompatible with both DC and AC field loads on the relay outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for discrete control applications in industrial automation systems, specifically where mixed signal types are required in a single rack slot. It is commonly used for interfacing with high-current field devices that require physical contact isolation.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 (Relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Input Voltage\u003c\/td\u003e\n\u003ctd\u003e74 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Input Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 20 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Input Current\u003c\/td\u003e\n\u003ctd\u003e6 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Voltage\u003c\/td\u003e\n\u003ctd\u003e5 to 30 VDC \/ 5 to 250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load Current\u003c\/td\u003e\n\u003ctd\u003e2 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Inrush Current\u003c\/td\u003e\n\u003ctd\u003e5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Field to Logic)\u003c\/td\u003e\n\u003ctd\u003e1500 V RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA @ 5 VDC, 70 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the backplane connector and secured with the integrated locking mechanism.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded cabling for field inputs to reduce EMI\/RFI noise in high-interference environments.\u003c\/li\u003e\n\u003cli\u003eEnsure that the relay output load does not exceed the maximum current rating (2A) or inrush current limits (5A) to prevent contact degradation.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate airflow within the cabinet to ensure the module operates within the 0 to 60 deg C temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IC693MAR590?\u003c\/strong\u003e\u003cbr\u003eIt is a mixed I\/O module that provides 8 AC inputs and 8 relay outputs for the Series 90-30 PLC system, allowing for both monitoring and control of field devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the relay outputs?\u003c\/strong\u003e\u003cbr\u003eYes, the module requires 24 VDC to drive the internal relay coils, in addition to the 5 VDC required for the backplane logic.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50995263930620,"sku":"IC693MAR590","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_9f5f3abb-679a-4f36-b606-41286f01afc3.jpg?v=1787079459","url":"https:\/\/www.electronicplc.com\/es\/products\/ge-fanuc-ic693mar590-series-90-30-mixed-i-o-module","provider":"Electronic PLC","version":"1.0","type":"link"}