{"product_id":"ge-fanuc-ic695alg808-rx3i-pacsystem-isolated-analog-output-module","title":"GE Fanuc IC695ALG808 RX3i PACSystem Isolated Analog Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC695ALG808 is a high-density, isolated analog output module designed for the GE Fanuc Emerson PACSystem RX3i platform. This module provides eight independent channels capable of delivering precise voltage or current signals to field devices, including actuators, variable frequency drives, and control valves. Engineered for demanding industrial applications, it features a high-speed backplane interface and robust 2550 VDC isolation between field circuitry and the backplane to prevent ground loops and protect the controller from electrical surges.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight independent, isolated analog output channels.\u003c\/li\u003e\n\u003cli\u003eSupports multiple output ranges: 0 to +10 V, -10 to +10 V, 0-20 mA, and 4-20 mA.\u003c\/li\u003e\n\u003cli\u003eHigh-fidelity resolution: 14-bit for bipolar voltage and 15-bit for unipolar voltage and current.\u003c\/li\u003e\n\u003cli\u003eFast 8 ms update rate across all channels with a 2 ms settling time.\u003c\/li\u003e\n\u003cli\u003eSupports both IEEE 32-bit floating point and 16-bit integer data formats.\u003c\/li\u003e\n\u003cli\u003eRequires external 24 VDC power supply for output circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for mission-critical control loops in industries such as oil and gas, power generation, and mining. It is ideal for driving proportional control valves, positioners, and remote instrumentation where signal isolation and high precision are required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG808\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 Independent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V, -10 to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14-bit (bipolar), 15-bit (unipolar\/current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e8 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSettling Time\u003c\/td\u003e\n\u003ctd\u003e2 ms (0 to 95%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2550 VDC (1 second)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Power\u003c\/td\u003e\n\u003ctd\u003e360 mA @ 3.3 VDC; 17 mA @ 5.0 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC (19.2 to 30 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Load\u003c\/td\u003e\n\u003ctd\u003e1350 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the RX3i backplane is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module must be installed in a standard RX3i rack slot; ensure the module is fully seated and the locking levers are engaged.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analog signals to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eGround the cable shields at the source or the module end according to your specific system grounding plan to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module for proper ventilation to manage the 7.25 W maximum power dissipation.\u003c\/li\u003e\n\u003cli\u003eVerify that the external 24 VDC power supply is within the 19.2 V to 30 V range before connecting to the terminal block.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes this module support HART communication?\u003c\/h3\u003e\u003cp\u003eNo, the IC695ALG808 is a standard isolated analog output module and does not support HART protocol communication.\u003c\/p\u003e\u003ch3\u003eIs an external power supply mandatory?\u003c\/h3\u003e\u003cp\u003eYes, an external 24 VDC power supply is required to energize the output circuitry of the module. The backplane power is used for internal logic and communication only.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50730377314556,"sku":"IC695ALG808","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_73d6da20-736b-4b90-9145-9e9af1801a9e.jpg?v=1785220520","url":"https:\/\/www.electronicplc.com\/es\/products\/ge-fanuc-ic695alg808-rx3i-pacsystem-isolated-analog-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}