{"product_id":"ge-fanuc-ic697mdl750-series-90-70-discrete-output-module","title":"General Electric IC697MDL750 90-70 Series 32-Point Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC697MDL750 is a 32-point discrete output module designed for the Series 90-70 Programmable Logic Controller (PLC) system. It operates within a voltage range of 24\/48 VDC and provides 0.5 Amperes of current capacity per output point. The module is organized into four isolated groups of eight points each, offering flexibility for various control applications. It is engineered to handle high inrush currents, making it suitable for driving inductive loads such as solenoids and motor starters.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32 discrete output points arranged in four isolated groups of 8 points each.\u003c\/li\u003e\n\u003cli\u003eHigh inrush current capacity (up to 20x rated current) for demanding load types.\u003c\/li\u003e\n\u003cli\u003eLED status indicators for each point located on the front of the module for easy diagnostics.\u003c\/li\u003e\n\u003cli\u003eMechanically keyed design to prevent incorrect module insertion in the rack.\u003c\/li\u003e\n\u003cli\u003eUser-configurable I\/O references via programming software; no physical jumpers or DIP switches required.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely used in industrial automation environments where reliable discrete control is required, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAutomotive manufacturing and assembly lines.\u003c\/li\u003e\n\u003cli\u003ePower generation and substation control systems.\u003c\/li\u003e\n\u003cli\u003ePulp and paper processing facilities.\u003c\/li\u003e\n\u003cli\u003eChemical and oil refinery process control.\u003c\/li\u003e\n\u003cli\u003eFood and beverage batch processing and packaging.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eIC697MDL750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20 to 60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e24 \/ 48 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e32 (4 isolated groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Group\u003c\/td\u003e\n\u003ctd\u003e2.0 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e10 Amps for 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-state Leakage\u003c\/td\u003e\n\u003ctd\u003e1 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Field to Logic)\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Group to Group)\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Always power down the PLC rack before inserting or removing the module to prevent electrical damage or system faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e The module is designed for the Series 90-70 backplane. Ensure the module is fully seated and the rack clips are engaged.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing:\u003c\/strong\u003e It is recommended to use external fast-acting fuses on all load lines to protect the module's internal circuitry from short circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Loads:\u003c\/strong\u003e When controlling motor contactors or solenoids, install external RC snubber networks across the load to suppress voltage spikes and protect the output transistors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure adequate ventilation within the cabinet to manage heat dissipation, particularly when operating at the maximum 2 Amp per group capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IC697MDL750?\u003c\/h3\u003e\u003cp\u003eThe IC697MDL750 is a discrete output module for the GE 90-70 PLC series, used to interface the controller with field devices such as indicators, solenoids, and motor starters.\u003c\/p\u003e\u003ch3\u003eCan this module be used for 24V and 48V applications?\u003c\/h3\u003e\u003cp\u003eYes, the module is designed for a nominal range of 24\/48 VDC, with an operating range of 20 to 60 VDC.\u003c\/p\u003e\u003ch3\u003eHow are the outputs organized?\u003c\/h3\u003e\u003cp\u003eThe 32 outputs are divided into four electrically isolated groups, each containing eight output points.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50910555930876,"sku":"IC697MDL750","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_16e751ea-8c31-400d-8f07-a68cb0d7fba6.jpg?v=1785671413","url":"https:\/\/www.electronicplc.com\/es\/products\/ge-fanuc-ic697mdl750-series-90-70-discrete-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}