{"product_id":"ge-fanuc-versamax-ic200mdl650-discrete-input-module","title":"General Electric IC200MDL650 VersaMax 32-Point Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC200MDL650 is a high-density 32-point discrete input module designed for the GE VersaMax I\/O platform. This module provides reliable signal acquisition for industrial control systems, supporting both positive and negative logic wiring configurations. It is organized into four groups of eight input channels each, allowing for flexible integration with various field devices such as limit switches, proximity sensors, pushbuttons, and auxiliary contacts.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32 discrete input channels arranged in four groups of eight.\u003c\/li\u003e\n\u003cli\u003eSupports both positive and negative logic configurations.\u003c\/li\u003e\n\u003cli\u003eConfigurable input filtering (0 ms, 1.0 ms default, or 7.0 ms) to suppress noise and eliminate mechanical contact bounce.\u003c\/li\u003e\n\u003cli\u003eHigh-density design suitable for space-constrained control cabinets.\u003c\/li\u003e\n\u003cli\u003eGroup-to-group isolation rated at 250 VAC continuous and 1500 VAC for 1 minute.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePump station control and monitoring of start\/stop status.\u003c\/li\u003e\n\u003cli\u003eHydropower station signal acquisition for turbines and circuit breakers.\u003c\/li\u003e\n\u003cli\u003eIntelligent fire-fighting water supply systems using pressure and level switches.\u003c\/li\u003e\n\u003cli\u003eThermal control and conveyor logic for industrial furnace applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Voltage\u003c\/td\u003e\n\u003ctd\u003e15 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Current\u003c\/td\u003e\n\u003ctd\u003e2.0 to 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Current\u003c\/td\u003e\n\u003ctd\u003e0 to 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e50 mA at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10k Ohms (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Times\u003c\/td\u003e\n\u003ctd\u003e0 ms, 1.0 ms (default), 7.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system is powered down before installing or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eMount the module on a standard DIN rail or compatible VersaMax rack system, ensuring secure seating to maintain backplane connectivity.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for input signals to minimize electromagnetic interference (EMI) in high-noise environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper wire routing to separate signal lines from high-voltage power cables.\u003c\/li\u003e\n\u003cli\u003eObserve correct polarity when wiring for positive or negative logic configurations.\u003c\/li\u003e\n\u003cli\u003eHandle with care using ESD-safe practices to prevent damage to sensitive internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the IC200MDL650?\u003c\/h3\u003e\u003cp\u003eThe GE IC200MDL650 is a 32-point, 24VDC discrete input module from the VersaMax PLC series, used to interface field devices with the control system.\u003c\/p\u003e\u003ch3\u003eWhat is the input voltage range?\u003c\/h3\u003e\u003cp\u003eThe module operates with a 24 VDC nominal voltage, with an input range of 0 to 30 VDC.\u003c\/p\u003e\u003ch3\u003eHow are the inputs configured?\u003c\/h3\u003e\u003cp\u003eThe 32 inputs are organized into four groups of eight channels each, supporting both positive and negative logic wiring.\u003c\/p\u003e\u003ch3\u003eCan the input response time be adjusted?\u003c\/h3\u003e\u003cp\u003eYes, users can configure input filter times via the CPU software to 0 ms, 1.0 ms (default), or 7.0 ms to filter out noise or contact bounce.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50708732018940,"sku":"IC200MDL650","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ecd5e19e-bbad-4bef-b0f1-c62e8556e6cb.jpg?v=1785137254","url":"https:\/\/www.electronicplc.com\/es\/products\/ge-fanuc-versamax-ic200mdl650-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}