{"product_id":"general-electric-mark-vie-is200stcih2aed-simplex-contact-input-terminal-board","title":"General Electric IS200STCIH2AED Mark VIe Simplex Contact Input Terminal Board","description":"\u003cp\u003eThe GE IS200STCIH2AED is a Simplex Contact Input Terminal Board designed for the Mark VIe and Mark VIeS turbine control platforms. This interface module serves as a field connection point, accepting 24 discrete contact inputs from external devices such as relays, switches, and limit sensors. It is engineered to condition and filter these signals before they are processed by a compatible PAIC I\/O pack.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for simplex control architectures in Mark VIe\/VIeS systems.\u003c\/li\u003e\n\u003cli\u003eSupports 24 VDC, 48 VDC, and 125 VDC external excitation voltages.\u003c\/li\u003e\n\u003cli\u003eIntegrated surge suppression and high-frequency noise filtering for signal integrity.\u003c\/li\u003e\n\u003cli\u003eUtilizes resettable polymer (PTC) fuses for overcurrent protection.\u003c\/li\u003e\n\u003cli\u003eCompatible with PAIC I\/O packs via a D-type connector interface.\u003c\/li\u003e\n\u003cli\u003eCompact design suitable for DIN-rail or flat-panel mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eGas and steam turbine control systems.\u003c\/li\u003e\n\u003cli\u003eGenerator set monitoring and protection.\u003c\/li\u003e\n\u003cli\u003eBalance-of-plant (BOP) control logic.\u003c\/li\u003e\n\u003cli\u003eCritical production line status monitoring and alarm feedback.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200STCIH2AED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExcitation Voltage\u003c\/td\u003e\n\u003ctd\u003e24, 48, 125 VDC (Field-selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Limit\u003c\/td\u003e\n\u003ctd\u003e2.5 mA (circuits 1-21); 10 mA (circuits 22-24)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Filter\u003c\/td\u003e\n\u003ctd\u003e4 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system power is disconnected before installing or removing the terminal board.\u003c\/li\u003e\n\u003cli\u003eThe board is typically mounted on a sheet metal carrier, which is then secured to a standard DIN rail.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for field inputs to minimize EMI\/RFI interference in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the external excitation voltage matches the configured input range to prevent damage to the sensing circuits.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the module to ensure proper airflow and cooling.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the IS200STCIH2AED?\u003c\/h3\u003e\u003cp\u003eIt acts as a terminal board for the Mark VIe system, providing signal conditioning and surge protection for up to 24 contact inputs before they are digitized by the I\/O pack.\u003c\/p\u003e\u003ch3\u003eDoes this board include the I\/O pack?\u003c\/h3\u003e\u003cp\u003eNo, the IS200STCIH2AED is a terminal board only. It requires a separate PAIC I\/O pack, which connects to the board via a D-type connector.\u003c\/p\u003e\u003ch3\u003eHow do the resettable fuses function?\u003c\/h3\u003e\u003cp\u003eThe board uses PTC (positive temperature coefficient) fuses. If a fault causes current to exceed 0.5A, the fuse limits the current; once the fault is cleared, the device cools and automatically resets, requiring no manual replacement.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50988603900156,"sku":"IS200STCIH2AED","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_1f747ac3-eb93-44a8-9a77-67e733b686ba.jpg?v=1786907472","url":"https:\/\/www.electronicplc.com\/es\/products\/general-electric-mark-vie-is200stcih2aed-simplex-contact-input-terminal-board","provider":"Electronic PLC","version":"1.0","type":"link"}