{"product_id":"honeywell-rm7800l1079-7800-series-relay-module","title":"Honeywell RM7800L1079 7800 SERIES Burner Control Relay Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell RM7800L1079 is a microprocessor-based burner control relay module designed for industrial combustion safety and sequencing applications. As a core component of the 7800 SERIES architecture, this module provides reliable flame supervision, safe start-up\/shutdown logic, and automated burner management. It is engineered for use in boiler systems, process heaters, and power generation burner management systems, ensuring deterministic control of ignition, purge, and run cycles.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMicroprocessor-based logic for precise burner sequencing and safety interlock management.\u003c\/li\u003e\n\u003cli\u003eIntegrated flame supervision capabilities for enhanced operational safety.\u003c\/li\u003e\n\u003cli\u003eModular plug-in design for rapid replacement and reduced system downtime.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard 7800 SERIES keyboard display modules for real-time status monitoring and configuration.\u003c\/li\u003e\n\u003cli\u003eSupports automated programming sequences including pre-purge, ignition, and post-purge cycles.\u003c\/li\u003e\n\u003cli\u003eDesigned for 120 VAC control supply environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe RM7800L1079 is widely utilized in heavy industrial thermal systems, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIndustrial boiler control systems.\u003c\/li\u003e\n\u003cli\u003eProcess heater management.\u003c\/li\u003e\n\u003cli\u003ePower generation burner management systems.\u003c\/li\u003e\n\u003cli\u003eRefinery and petrochemical combustion safety applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRM7800L1079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e7800 SERIES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBurner Control Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e120 VAC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox 10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePlug-in rack configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is completely disconnected before inserting or removing the module from the chassis.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for plug-in installation within a standard 7800 SERIES burner control chassis.\u003c\/li\u003e\n\u003cli\u003eVerify that the chassis wiring matches the required configuration for the RM7800L1079 model.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the burner management cabinet to prevent electrical noise interference.\u003c\/li\u003e\n\u003cli\u003eHandle the module with care to avoid damage to the connector pins on the rear of the unit.\u003c\/li\u003e\n\u003cli\u003eAfter installation, perform a full system test to verify that all safety interlocks and sequencing logic are functioning as intended.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the RM7800L1079?\u003c\/h3\u003e\u003cp\u003eThe RM7800L1079 serves as a burner control relay module that manages the safe sequencing of burner start-up, operation, and shutdown, while providing integrated flame supervision.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with other 7800 SERIES components?\u003c\/h3\u003e\u003cp\u003eYes, the RM7800L1079 is designed to integrate with standard 7800 SERIES keyboard display modules and auxiliary interface units for configuration and monitoring.\u003c\/p\u003e\u003ch3\u003eWhat power supply is required for this module?\u003c\/h3\u003e\u003cp\u003eThis module is designed to operate on a 120 VAC, 60 Hz power supply.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50910170808572,"sku":"RM7800L1079","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_9a89a22c-791c-44d2-bcb9-e66c225283ff.jpg?v=1785645631","url":"https:\/\/www.electronicplc.com\/es\/products\/honeywell-rm7800l1079-7800-series-relay-module","provider":"Electronic PLC","version":"1.0","type":"link"}