{"product_id":"honeywell-rm7823a1016-flame-detector-relay-module","title":"Honeywell RM7823A1016 Flame Detector Relay Module","description":"\u003cp\u003eThe Honeywell RM7823A1016 is a microprocessor-based flame safeguard relay module designed for industrial burner management systems. It provides critical flame signal processing and relay output control for boilers, furnaces, process heaters, and combustion control skids. By continuously evaluating flame sensor inputs, the module ensures safe burner operation and initiates immediate shutdown in the event of flame failure.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMicroprocessor-based flame verification engine for high-reliability signal processing.\u003c\/li\u003e\n\u003cli\u003eCompatible with UV and IR flame sensors for versatile burner monitoring.\u003c\/li\u003e\n\u003cli\u003eDeterministic relay output architecture for safe fuel valve and ignition interlock control.\u003c\/li\u003e\n\u003cli\u003eIntegrated timing-based discrimination logic to mitigate false flame detection from electrical noise or transient light.\u003c\/li\u003e\n\u003cli\u003eFail-safe design ensures transition to a lockout state upon detection of internal faults or loss of flame signal.\u003c\/li\u003e\n\u003cli\u003eStandard RM7800 series plug-in architecture for simplified installation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is intended for use in high-risk thermal environments, including power generation plants, oil refineries, and chemical processing facilities. It serves as a core component within the Honeywell RM7800 series burner management architecture to maintain safety standards in combustion control loops.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRM7823A1016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlame Detector Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-based signal verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePlug-in base module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Function\u003c\/td\u003e\n\u003ctd\u003eFlame failure detection, lockout control, automatic shutdown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the burner management system is fully powered down before inserting or removing the module from the base.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is securely seated in the RM7800 series base to ensure proper backplane contact.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding of the burner control cabinet to minimize electromagnetic interference (EMI) on flame sensor signal lines.\u003c\/li\u003e\n\u003cli\u003eRoute flame sensor signal cables separately from high-voltage power lines to prevent signal corruption.\u003c\/li\u003e\n\u003cli\u003eEnsure the installation environment remains within the specified temperature range of 0 to 60 deg C to prevent thermal degradation of internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the RM7823A1016?\u003c\/h3\u003e\u003cp\u003eThe RM7823A1016 acts as a flame safeguard relay that monitors flame presence via connected sensors and controls burner safety interlocks, such as fuel valves and ignition systems, to prevent hazardous operation.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with existing RM7800 series systems?\u003c\/h3\u003e\u003cp\u003eYes, the RM7823A1016 is designed for the Honeywell RM7800 series burner management platform and utilizes standard plug-in base mounting for easy integration or replacement.\u003c\/p\u003e\u003ch3\u003eWhat happens if the module detects a flame failure?\u003c\/h3\u003e\u003cp\u003eThe module executes internal safety logic to trigger an immediate shutdown and enters a lockout state, which requires a manual reset to restore operation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50969287327996,"sku":"RM7823A1016","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_76c1de5d-9d69-470b-b87a-ff6de555b890.jpg?v=1786500652","url":"https:\/\/www.electronicplc.com\/es\/products\/honeywell-rm7823a1016-flame-detector-relay-module","provider":"Electronic PLC","version":"1.0","type":"link"}