{"product_id":"ic610mdl101-ge-fanuc-input-module","title":"GE Fanuc IC610MDL101 8-Point DC Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC610MDL101 is an 8-point DC input module specifically engineered for the Series One programmable logic controller (PLC) platform. This module serves as a critical interface between field devices and the controller, providing reliable signal acquisition for automated assembly lines, material handling systems, and machine control applications. By utilizing a sink-type input architecture, the IC610MDL101 ensures stable detection of binary field signals while providing electrical isolation to protect sensitive control logic from external noise.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8-point discrete DC input capacity for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eSink-type input configuration for standard industrial field device compatibility.\u003c\/li\u003e\n\u003cli\u003eIntegrated LED status indicators for each channel to facilitate rapid visual diagnostics and troubleshooting.\u003c\/li\u003e\n\u003cli\u003eHigh-impedance signal processing (1.8 kOhm) to minimize loading on field sensors.\u003c\/li\u003e\n\u003cli\u003eRack-mount design for seamless integration into existing Series One PLC backplanes.\u003c\/li\u003e\n\u003cli\u003eDirect power draw from the system rack, simplifying installation and reducing external cabling requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe IC610MDL101 is widely utilized in legacy automation systems where the Series One platform remains in operation. Typical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated manufacturing and assembly lines.\u003c\/li\u003e\n\u003cli\u003eMaterial handling and conveyor control systems.\u003c\/li\u003e\n\u003cli\u003eLocal machine control cabinets requiring discrete sensor feedback.\u003c\/li\u003e\n\u003cli\u003eProcess monitoring where binary state detection is required for sequence control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC610MDL101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSeries One\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e8-Point Sink Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Input Voltage\u003c\/td\u003e\n\u003ctd\u003e36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e18 mA per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e1.8 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current Leakage\u003c\/td\u003e\n\u003ctd\u003e3 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Power Consumption\u003c\/td\u003e\n\u003ctd\u003e14 mA per ON circuit at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eRack-mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always disconnect power from the PLC rack before inserting or removing the module to prevent electrical arcing or damage to the backplane connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e Handle the module by its edges or housing. Use a grounded wrist strap when handling internal components to prevent electrostatic discharge damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the module is fully seated in the rack slot and the retention screws are tightened to maintain a secure electrical connection to the backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded cables for field inputs to minimize EMI\/RFI interference. Route signal cables away from high-voltage power lines and motor drive cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the control cabinet provides adequate ventilation to maintain operating temperatures within the specified range for the Series One system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch3\u003eIs this module compatible with Series One Plus systems?\u003c\/h3\u003e\n\u003cp\u003eYes, the IC610MDL101 is designed for the GE Fanuc Series One platform and is generally compatible with Series One and Series One Plus rack configurations.\u003c\/p\u003e\n\u003ch3\u003eWhat does the sink-type input mean?\u003c\/h3\u003e\n\u003cp\u003eA sink-type input means the module provides the return path for the current. The field device (such as a switch or sensor) connects the input terminal to the positive supply voltage to trigger the input.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50919534657788,"sku":"IC610MDL101","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b3634a08-38fa-409b-8c1c-a8893a511b79.jpg?v=1785904075","url":"https:\/\/www.electronicplc.com\/es\/products\/ic610mdl101-ge-fanuc-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}