{"product_id":"ic694mdl645-ge-fanuc-pacsystems-rx3i-discrete-input-module","title":"GE Fanuc IC694MDL645 PACSystems RX3i Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC694MDL645 is a high-density discrete input module engineered for the GE Fanuc PACSystems RX3i control platform. This module provides 16 isolated input channels, supporting both positive and negative logic (sink\/source) configurations to accommodate diverse field device requirements. It is designed for high-speed signal processing in demanding industrial environments, including power generation, oil and gas, and water treatment, ensuring reliable data acquisition from field sensors to the CPU.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 isolated input channels organized in a single group.\u003c\/li\u003e\n\u003cli\u003eSupports 24 VDC nominal input voltage with a wide operating range of 0 to 30 VDC.\u003c\/li\u003e\n\u003cli\u003eCompatible with the PACSystems RX3i universal backplane.\u003c\/li\u003e\n\u003cli\u003eSupports hot-swap functionality for maintenance without system shutdown.\u003c\/li\u003e\n\u003cli\u003eIntegrated filtering for robust signal integrity in high-EMI environments.\u003c\/li\u003e\n\u003cli\u003eComprehensive diagnostics accessible via controller software.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is suitable for critical control loops and automation systems requiring high-density discrete input monitoring. Typical applications include status monitoring of switches, proximity sensors, and pushbuttons within PACSystems RX3i architectures.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694MDL645\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (1 group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e11.5 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e3.2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e1.1 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e7 mA (at nominal voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e7 ms (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA @ 5 VDC (bus); 125 mA @ 24 VDC (supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C (-40 to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the RX3i backplane is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify the module is fully seated in the rack slot and the locking mechanism is engaged.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded cabling for input signals to minimize noise interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the cabinet to keep the ambient temperature within the 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) handling procedures when touching the module circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the IC694MDL645 module hot-swappable?\u003c\/h3\u003e\u003cp\u003eYes, the module supports hot-swapping, allowing it to be removed or inserted into an RX3i backplane while the system is under power, provided the installation guidelines are followed.\u003c\/p\u003e\u003ch3\u003eDoes this module support both sink and source configurations?\u003c\/h3\u003e\u003cp\u003eYes, the IC694MDL645 is designed to support both positive and negative logic (sink\/source) configurations for its 16 input channels.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50644516176124,"sku":"IC694MDL645","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_0f5c976a-f830-4ef7-a758-5d774f830938.jpg?v=1784966081","url":"https:\/\/www.electronicplc.com\/es\/products\/ic694mdl645-ge-fanuc-pacsystems-rx3i-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}