{"product_id":"ic698rmx016-pacsystem-rx7i-ge-fanuc-communication-module","title":"General Electric IC698RMX016 PACSystems RX7i Communication Module","description":"\u003cp\u003eThe General Electric IC698RMX016 is a high-performance Control Memory Xchange (CMX) module designed for the PACSystems RX7i platform. This module facilitates deterministic data sharing across PLCs and computing devices using high-speed reflective memory technology. It is engineered for demanding industrial environments, providing a reliable link for redundant systems and multi-node network architectures.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSingle-slot form factor for PACSystems RX7i racks.\u003c\/li\u003e\n\u003cli\u003e16 MB of reflective memory with parity support.\u003c\/li\u003e\n\u003cli\u003eHigh-speed 2.12 Gbaud fiber-optic network interface.\u003c\/li\u003e\n\u003cli\u003eCompatible with the VMIC 5565 family of reflective memory devices.\u003c\/li\u003e\n\u003cli\u003eSupports up to 256 nodes per network loop.\u003c\/li\u003e\n\u003cli\u003eDynamic packet sizing (4 to 64 bytes) for optimized data throughput.\u003c\/li\u003e\n\u003cli\u003eProgrammable VMEbus interrupt output with four general-purpose network interrupts.\u003c\/li\u003e\n\u003cli\u003eSoftware-configurable node parameters for flexible system integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePower Generation \u0026amp; Utilities: Turbine control and plant monitoring requiring bumpless CPU transfer.\u003c\/li\u003e\n\u003cli\u003eMetal \u0026amp; Steel Production: Reliable operation in rolling mills and blast furnaces.\u003c\/li\u003e\n\u003cli\u003eProcess Manufacturing: Synchronization of large data sets across cement, paper, and chemical processing nodes.\u003c\/li\u003e\n\u003cli\u003eMaritime \u0026amp; Shipbuilding: Propulsion and navigation control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC698RMX016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e16 MB SDRAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Requirement\u003c\/td\u003e\n\u003ctd\u003e1.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Speed\u003c\/td\u003e\n\u003ctd\u003e2.12 Gbaud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Compatibility\u003c\/td\u003e\n\u003ctd\u003eMultimode (up to 300m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsertion Loss\u003c\/td\u003e\n\u003ctd\u003e0.35 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReturn Loss\u003c\/td\u003e\n\u003ctd\u003e-30 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the rack power is completely switched off before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for installation in the main RX7i rack (Rack 0).\u003c\/li\u003e\n\u003cli\u003eSlots 3 and 4 are recommended to provide optimal VME interrupt request priority.\u003c\/li\u003e\n\u003cli\u003eSlide the module carefully into the designated slot; press firmly until seated.\u003c\/li\u003e\n\u003cli\u003eTighten the screws on the top and bottom of the faceplate to ensure a secure mechanical connection and proper grounding.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to protect sensitive internal components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the IC698RMX016?\u003c\/h3\u003e\u003cp\u003eIt is a 16MB Redundant Memory Xchange module for the GE Fanuc RX7i PACSystem. It functions as a node on a reflective memory network or as a dedicated link between CPUs in a redundant system.\u003c\/p\u003e\u003ch3\u003eWhat is the data transfer rate?\u003c\/h3\u003e\u003cp\u003eThe module utilizes a 2.12 Gbaud fiber-optic network, with effective transfer rates typically ranging between 3.2 MB\/s and 6.2 MB\/s depending on the redundancy density.\u003c\/p\u003e\u003ch3\u003eWhat type of connection does it use?\u003c\/h3\u003e\u003cp\u003eIt utilizes a fiber optic LC-type connector (IEC 61754-20) with a zirconium ceramic ferrule.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50995249676540,"sku":"IC698RMX016","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_bfef02e8-348c-4fba-858a-693c2d605ccd.jpg?v=1787078899","url":"https:\/\/www.electronicplc.com\/es\/products\/ic698rmx016-pacsystem-rx7i-ge-fanuc-communication-module","provider":"Electronic PLC","version":"1.0","type":"link"}