{"product_id":"k9192qj-thermal-conductivity-detector-yokogawa","title":"K9192QJ Thermal Conductivity Detector Yokogawa","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa K9192QJ\u003c\/strong\u003e Thermal Conductivity Detector (TCD) operates as a dedicated hardware component for precise gas composition analysis and concentration measurement within industrial process gas chromatography systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eK9192QJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Analyzer Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow voltage bridge excitation required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Principle\u003c\/td\u003e\n\u003ctd\u003eThermal conductivity (filament resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003eBridge imbalance voltage (mV scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe K9192QJ is engineered for high-sensitivity gas detection by utilizing a Wheatstone bridge circuit consisting of temperature-sensitive filaments. As carrier gas flows across the sensing and reference filaments, variations in thermal conductivity—induced by the presence of analytes—cause changes in filament temperature and electrical resistance. The resulting bridge imbalance voltage is proportional to the component concentration. To maintain signal integrity, the module features channel-to-channel isolation architecture, effectively decoupling the measurement bridge from common-mode noise and power supply fluctuations within the analyzer cabinet.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the K9192QJ require a specific carrier gas for optimal performance?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The sensitivity and baseline stability of the detector are highly dependent on the difference in thermal conductivity between the carrier gas and the sample analytes. Helium or hydrogen is typically utilized as the carrier gas to maximize the signal-to-noise ratio.\u003c\/p\u003e\n\u003cp\u003eQ: Can the filament assembly be replaced independently of the module?\u003c\/p\u003e\n\u003cp\u003eA: No. The K9192QJ is factory-calibrated as a complete sensing unit. Attempting to replace the filaments will invalidate the factory calibration and likely compromise the sensitivity and linearity of the detector.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Ensure the detector is installed in a vibration-free environment. Mechanical shock can alter the filament alignment, leading to baseline drift and noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGas Connections\u003c\/strong\u003e: Use high-purity stainless steel tubing for all gas inlet and outlet paths. Ensure all connections are leak-tested to prevent ingress of atmospheric contaminants, which will degrade filament performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Management\u003c\/strong\u003e: Maintain the detector oven temperature within the specified range to ensure consistent baseline stability. Avoid rapid thermal cycling, which can induce stress on the filament supports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: The detector housing must be bonded to the analyzer system ground reference to mitigate electromagnetic interference and ensure the stability of the low-voltage output signal.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49529334890748,"sku":"K9192QJ","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/k9142TN1.jpg?v=1783562204","url":"https:\/\/www.electronicplc.com\/es\/products\/k9192qj-thermal-conductivity-detector-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}