{"product_id":"master-synchronizer-and-load-control-module-woodward-9007-005","title":"Master Synchronizer and Load Control Module Woodward 9007-005","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 9007-005\u003c\/strong\u003e serves as the primary \u003cstrong\u003e9007-005\u003c\/strong\u003e Master Synchronizer and Load Control Module utilized to execute phase synchronization, import\/export real power control, and reactive power management across three-phase generator bus network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e9007-005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e7.00 lbs (3.18 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14 in x 11 in x 4 in (35.6 cm x 28 cm x 10.2 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Operating Load (18 to 32 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Input\u003c\/td\u003e\n\u003ctd\u003e18 to 32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Transformer Range\u003c\/td\u003e\n\u003ctd\u003e5 A nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Accuracy\u003c\/td\u003e\n\u003ctd\u003e1 percent at 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Isolation\u003c\/td\u003e\n\u003ctd\u003e1000 Vrms (0 to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Network Capacity\u003c\/td\u003e\n\u003ctd\u003e64 nodes per bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMSLC Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback \u0026amp; Harmonic Distortion Suppression\u003c\/h3\u003e\n\u003cp\u003eOperating alongside Woodward DSLC controls via a high-speed Local Area Network (LAN) supporting up to 64 nodes, the module processes voltage phase angles, frequency deltas, and current vectors. Dynamic speed and voltage adjust commands modulate prime mover fuel racks and excitation loops, maintaining rapid actuator loop feedback response during breaker closure sequences. Galvanic network isolation rated at 1000 Vrms (0 to 60 Hz) shields internal microprocessors from harmonic distortion and common-mode transients inherent in high-current utility grid interconnections.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: What cable type and grounding topology are required for the 5 A Current Transformer (CT) inputs?\u003c\/li\u003e\n\u003cli\u003eA: CT secondary wiring must utilize twisted-pair conductors routed through shorting-type terminal blocks. Shield drain wires must terminate exclusively at the central frame ground point to prevent ground loop noise.\u003c\/li\u003e\n\u003cli\u003eQ: How does network isolation protect communication between the MSLC and DSLC units?\u003c\/li\u003e\n\u003cli\u003eA: Galvanic isolation rated at 1000 Vrms (0 to 60 Hz) breaks ground potential differentials between interconnected control enclosures across the 64-node network bus.\u003c\/li\u003e\n\u003cli\u003eQ: What are the input voltage tolerances for the main DC power connection?\u003c\/li\u003e\n\u003cli\u003eA: The internal power regulation circuit accepts a continuous input range of 18 to 32 VDC, requiring an inline fuse for overcurrent protection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module vertically on a flat, grounded structural panel inside an enclosure using all four mounting holes to withstand operational vibration.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 50 mm around the outer housing vents to facilitate passive convection cooling across the operating range of -40 to +55 deg C.\u003c\/li\u003e\n\u003cli\u003eConnect a heavy-gauge copper ground jumper from the chassis grounding stud directly to the main switchgear earth bus.\u003c\/li\u003e\n\u003cli\u003eConfirm that CT input secondary circuits are properly phased and grounded at a single point prior to energizing primary generator loads.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50738747834620,"sku":"9907-005","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/9907-005.jpg?v=1785376956","url":"https:\/\/www.electronicplc.com\/es\/products\/master-synchronizer-and-load-control-module-woodward-9007-005","provider":"Electronic PLC","version":"1.0","type":"link"}