{"product_id":"mvi56-hart-prosoft-controllogix-hart-master-module","title":"ProSoft MVI56-HART ControlLogix HART Master Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe ProSoft MVI56-HART is a 4-channel HART Master Multi-drop Network Interface Module designed for integration with the Rockwell Automation ControlLogix platform. This module facilitates bi-directional communication between ControlLogix processors and HART-compatible field instruments, providing essential access to secondary digital variables and device diagnostics. By enabling real-time asset management and predictive maintenance, the MVI56-HART helps reduce unplanned downtime and optimizes calibration cycles in demanding industrial process control applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour independent HART channels supporting both point-to-point and multi-drop network topologies.\u003c\/li\u003e\n\u003cli\u003eFSK digital signal processing allows for simultaneous analog 4-20 mA monitoring and digital data extraction.\u003c\/li\u003e\n\u003cli\u003eOffloads protocol framing, timing, and error checking from the ControlLogix CPU to ensure efficient system performance.\u003c\/li\u003e\n\u003cli\u003eIntegrated status LEDs for backplane activity, error status, and individual channel communication monitoring.\u003c\/li\u003e\n\u003cli\u003eDirect backplane compatibility with ControlLogix chassis for seamless integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MVI56-HART is widely utilized in process-intensive industries including oil and gas refineries, chemical processing plants, and large-scale water treatment facilities where smart instrumentation diagnostics are required for operational efficiency.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI56-HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHART Master Multi-drop Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4 Independent HART Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Support\u003c\/td\u003e\n\u003ctd\u003ePoint-to-point or Multi-drop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e800 mA at 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the ControlLogix chassis power is removed before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for standard ControlLogix rack mounting; ensure the module is fully seated and the locking tab is engaged.\u003c\/li\u003e\n\u003cli\u003eUse appropriate shielded cabling for HART communication to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation within the cabinet to ensure operating temperatures remain within the 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions when handling the module to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the MVI56-HART?\u003c\/h3\u003e\u003cp\u003eThe MVI56-HART acts as a gateway between HART-enabled field devices and the ControlLogix controller, allowing the PLC to read digital process variables and diagnostic data from the instruments without interrupting the analog 4-20 mA signal.\u003c\/p\u003e\u003ch3\u003eDoes this module require external power?\u003c\/h3\u003e\u003cp\u003eThe module draws its power directly from the ControlLogix backplane (800 mA at 5.1 VDC). No external power supply is required for the module itself, though field instruments will require their own loop power.\u003c\/p\u003e","brand":"Prosoft","offers":[{"title":"Default Title","offer_id":50554445955324,"sku":"MVI56-HART","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_5ec28848-f3a1-4d13-8b6d-6533a89bd4bb.jpg?v=1784796932","url":"https:\/\/www.electronicplc.com\/es\/products\/mvi56-hart-prosoft-controllogix-hart-master-module","provider":"Electronic PLC","version":"1.0","type":"link"}