{"product_id":"netcon-5000-actuator-driver-module-woodward-5464-551","title":"NetCon 5000 Actuator Driver Module Woodward 5464-551","description":"\u003cp\u003eThe \u003cstrong\u003eWoodward 5464-551\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e5464-551\u003c\/strong\u003e Actuator Driver Module, operates as a dedicated hardware component for closed-loop actuator positioning and signal integration within NetCon 5000 platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5464-551\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWoodward\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.95kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard NetCon Module Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e18-36 VDC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e6 configurable channels (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e4 channels (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e12 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e8 relay outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e32-bit microcontroller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, Modbus TCP\/IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-485, RS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eActuator Loop Feedback Response and Real-Time Processing\u003c\/h3\u003e\n\u003cp\u003eDriven by an onboard 32-bit microcontroller, the 5464-551 card executes real-time data processing to optimize actuator loop feedback response in high-speed turbine regulation loops. The hardware combines 6 analog inputs (4-20 mA), 4 analog outputs (4-20 mA), 12 isolated digital inputs, and 8 relay outputs on a single rack-mounted board. Internal board layouts are engineered for efficient thermal heat sink dissipation profiles, maintaining stable current regulation and signal acquisition across the extended operating temperature envelope of -40 deg C to +85 deg C.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What communication protocols and physical interfaces are supported on the 5464-551?\u003c\/p\u003e\n\u003cp\u003eA: The card integrates Ethernet, RS-485, and RS-232 serial interfaces, providing native support for Modbus RTU and Modbus TCP\/IP protocols.\u003c\/p\u003e\n\u003cp\u003eQ: What is the operating voltage window for the primary power supply?\u003c\/p\u003e\n\u003cp\u003eA: The module operates across an input power supply range of 18-36 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How are the digital input signals isolated from system noise?\u003c\/p\u003e\n\u003cp\u003eA: All 12 digital input channels feature discrete galvanic isolation to prevent common-mode field noise from affecting controller processing logic.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that rack backplane power and external 18-36 VDC supply lines are fully de-energized before sliding the module into its chassis slot.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded twisted-pair cabling for all 4-20 mA analog I\/O loops and serial communication runs (RS-485\/RS-232).\u003c\/li\u003e\n\u003cli\u003eTerminate all cable shields to a designated chassis earth ground bar using low-impedance clamps to ensure EMC compliance.\u003c\/li\u003e\n\u003cli\u003eConfirm proper rack mounting retention screw torque to preserve physical frame alignment and earth ground continuity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Woodward","offers":[{"title":"Default Title","offer_id":50730080272636,"sku":"5464-552","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/5464-552.jpg?v=1785203758","url":"https:\/\/www.electronicplc.com\/es\/products\/netcon-5000-actuator-driver-module-woodward-5464-551","provider":"Electronic PLC","version":"1.0","type":"link"}