{"product_id":"schneider-electric-modicon-a120-dap112-discrete-output-module","title":"Schneider Electric Modicon A120 DAP112 Discrete Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe DAP112 is a high-density digital output interface module designed for the legacy Schneider Electric Modicon A120 programmable logic controller system. This module provides 16 independent discrete output channels configured for 24 V DC operation, facilitating reliable signal transmission, actuator control, and relay coil switching in demanding industrial environments such as power generation and petroleum processing. The module incorporates advanced solid-state switching and galvanic isolation to protect the control logic from field-side electrical disturbances.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 independent discrete output channels.\u003c\/li\u003e\n\u003cli\u003eSource-type (positive logic) output configuration.\u003c\/li\u003e\n\u003cli\u003eIntegrated electronic current limiting for short-circuit protection.\u003c\/li\u003e\n\u003cli\u003eBuilt-in free-wheeling clamping diodes for inductive load suppression.\u003c\/li\u003e\n\u003cli\u003e1500 V AC galvanic isolation between field wiring and the logic bus.\u003c\/li\u003e\n\u003cli\u003eFront-panel LED diagnostic matrix for module status, error detection, and individual channel state monitoring.\u003c\/li\u003e\n\u003cli\u003eRemovable front-accessible terminal block for efficient maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe DAP112 is engineered for use in industrial automation systems requiring high-density output control, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePetroleum and chemical processing installations.\u003c\/li\u003e\n\u003cli\u003eElectrical power generation and distribution plants.\u003c\/li\u003e\n\u003cli\u003eMining and material extraction facilities.\u003c\/li\u003e\n\u003cli\u003eGeneral-purpose discrete control loops for actuators and solenoid valves.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDAP112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric (Modicon)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSource (Positive Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e19.2 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Channel\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Aggregate Current\u003c\/td\u003e\n\u003ctd\u003e8.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-On\/Off Delay\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC (1 minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system power is disconnected before installing or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eMount the module in an environment compliant with the specified operating temperature (0 to 60 deg C) and humidity (5% to 95% non-condensing).\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for field-side wiring to minimize electromagnetic interference (EMI) in high-noise environments.\u003c\/li\u003e\n\u003cli\u003eVerify that all field-side loads are within the 0.5 A per channel and 8.0 A total module current limits.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the Modicon A120 rack assembly to maintain the integrity of the galvanic isolation barrier.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe practices to prevent damage to internal solid-state components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the DAP112 module?\u003c\/h3\u003e\u003cp\u003eThe DAP112 is a 16-channel discrete output module for the Modicon A120 system, used to switch 24 V DC field loads such as relays, solenoids, and actuators.\u003c\/p\u003e\u003ch3\u003eDoes this module provide protection against short circuits?\u003c\/h3\u003e\u003cp\u003eYes, the module features integrated electronic current limiting with automatic restart functionality to protect against short circuits and overloads.\u003c\/p\u003e\u003ch3\u003eWhat is the isolation rating of the DAP112?\u003c\/h3\u003e\u003cp\u003eThe module provides 1500 V AC galvanic isolation between the field-side wiring and the internal Modicon A120 logic bus.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50980939170044,"sku":"DAP112","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_08af188d-8e42-4eb6-8b5c-134a430c3b0a.jpg?v=1786732857","url":"https:\/\/www.electronicplc.com\/es\/products\/schneider-electric-modicon-a120-dap112-discrete-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}