{"product_id":"schneider-electric-modicon-premium-tsxstz10-bus-expansion-termination-block","title":"Schneider Electric TSXSTZ10 Modicon Premium Bus Expansion Termination Block","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe TSXSTZ10 is a dedicated line termination adapter designed for the Schneider Electric Modicon Premium automation network. This module is engineered to terminate high-speed TSXBusX backplane segments, matching the characteristic impedance of the distributed rack system data paths. It ensures precise electrical termination and signal stabilization for multi-rack setups in demanding industrial environments, including power generation, oil and gas, and mining operations. By absorbing residual transmission reflections and maintaining signal integrity, the TSXSTZ10 prevents data packet corruption, network synchronization dropouts, and system faults.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003ePassive, high-precision resistor-capacitor (RC) network design.\u003c\/li\u003e\n\u003cli\u003eMatches 100 Ohm nominal impedance of the TSXBusX communications line.\u003c\/li\u003e\n\u003cli\u003eIntegrated 9-pin male Sub-D connector with locking screws for vibration-resistant, gas-tight connectivity.\u003c\/li\u003e\n\u003cli\u003ePassive operation requiring no external power supply.\u003c\/li\u003e\n\u003cli\u003eHeavy internal shielding for EMI protection and continuous grounding path.\u003c\/li\u003e\n\u003cli\u003eCompact, rugged housing rated for IP20 protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe TSXSTZ10 is essential for any Modicon Premium system utilizing TSXBusX rack extensions. It is typically deployed at the end of a communication segment to ensure the stability of the high-speed expansion bus, particularly in systems spanning multiple racks or long distances where signal reflection could compromise data integrity.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXSTZ10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Type\u003c\/td\u003e\n\u003ctd\u003ePassive Line Termination Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e1 x 9-pin male Sub-D connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Impedance\u003c\/td\u003e\n\u003ctd\u003e100 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Compatibility\u003c\/td\u003e\n\u003ctd\u003eTSXBusX High-Speed Expansion Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Bus Speed\u003c\/td\u003e\n\u003ctd\u003e1 Mbits\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Grade\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is powered down before installing or removing any bus components.\u003c\/li\u003e\n\u003cli\u003eThe TSXSTZ10 plugs directly into the unused 9-pin female bus extension port on the final TSXRKY extension rack base.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the integrated locking screws to ensure a gas-tight connection and proper grounding through the rack chassis.\u003c\/li\u003e\n\u003cli\u003eAvoid routing communication cables near high-voltage lines or sources of significant electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eEnsure the environment remains within the specified temperature and humidity ranges to maintain long-term reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eDoes this module require an external power supply?\u003c\/h3\u003e\u003cp\u003eNo, the TSXSTZ10 is a completely passive device that requires 0.0 W of power. It derives its operational grounding path directly through the metallic shielding of the connected rack chassis.\u003c\/p\u003e\u003ch3\u003eWhere should the TSXSTZ10 be installed?\u003c\/h3\u003e\u003cp\u003eThis termination block must be installed on the final TSXRKY extension rack base of a TSXBusX communication segment to properly terminate the bus and prevent signal reflections.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50991258271996,"sku":"TSXSTZ10","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_3d351ab8-957c-4377-88b4-5c0d97f36454.jpg?v=1786990037","url":"https:\/\/www.electronicplc.com\/es\/products\/schneider-electric-modicon-premium-tsxstz10-bus-expansion-termination-block","provider":"Electronic PLC","version":"1.0","type":"link"}