{"product_id":"schneider-modicon-premium-tsxdey16a2-digital-input-modules","title":"Schneider Electric TSXDEY16A2 Modicon Premium Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Schneider Electric TSXDEY16A2 is a 16-channel discrete input module designed for the Modicon Premium automation platform. This module is specifically engineered to interface with 24 V AC field signals, making it an essential component for monitoring auxiliary contacts, field switches, and various interlocks in industrial environments. By incorporating robust hardware-based signal filtering, the module effectively mitigates issues related to line noise, contact bounce, and electromagnetic interference, ensuring stable and reliable state detection for the PLC controller.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 isolated input channels for high-density signal monitoring.\u003c\/li\u003e\n\u003cli\u003eOptimized for 24 V AC nominal input voltage operation.\u003c\/li\u003e\n\u003cli\u003eIntegrated hardware filtering to suppress transient spikes and mechanical bounce.\u003c\/li\u003e\n\u003cli\u003e1500 V AC dielectric isolation between field wiring and the internal backplane.\u003c\/li\u003e\n\u003cli\u003eCompact module design for standard Modicon Premium rack integration.\u003c\/li\u003e\n\u003cli\u003eReliable operation across a wide industrial temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in process automation sectors where AC-based signaling is prevalent, including power generation, chemical processing, and heavy-duty mining infrastructure. It is ideal for applications requiring the monitoring of safety-critical field devices and general-purpose status indicators.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTSXDEY16A2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e19 to 30 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e1.8 kOhm (at 50 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Latency\u003c\/td\u003e\n\u003ctd\u003e15 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e50 mA (at 5 V DC from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eHE10 Connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the rack power is disconnected before installing or removing the module to prevent electrical damage or backplane errors.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for field wiring to minimize the impact of high-frequency noise and electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the field common return is properly configured according to the system documentation.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation in the control cabinet to keep ambient temperatures within the specified 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eHandle with care to avoid damage to the backplane connector pins; ensure the module is fully seated and locked into the chassis guide rails.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the TSXDEY16A2?\u003c\/strong\u003e\u003cbr\u003eThis is a digital input module used to detect the status (on\/off) of 24 V AC field devices and communicate that state to the Modicon Premium PLC.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module require external power for the inputs?\u003c\/strong\u003e\u003cbr\u003eThe module is powered via the backplane, but the input signals themselves must be provided by a 24 V AC field power source.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat type of connector is used for this module?\u003c\/strong\u003e\u003cbr\u003eThe TSXDEY16A2 utilizes a standard HE10 connector block for field wiring connections.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51217570955516,"sku":"TSXDEY16A2","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_dd7eb493-619c-41d4-9506-f53ab16a5912.jpg?v=1788374373","url":"https:\/\/www.electronicplc.com\/es\/products\/schneider-modicon-premium-tsxdey16a2-digital-input-modules","provider":"Electronic PLC","version":"1.0","type":"link"}